• 제목/요약/키워드: Temperature control unit

Search Result 405, Processing Time 0.159 seconds

반도체 공정용 저온 열처리로의 고효율 냉각시스템 설계에 관한 연구 (Study on Design of high Efficient Cooling System for Low Temperature Furnace in Semiconductor Processing)

  • 정두원;서민석;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제9권4호
    • /
    • pp.71-76
    • /
    • 2010
  • According to recent changes in industry for semiconductor devices, a low-temperature treatment has become a necessity. These changes relate to size refinement and the development of new materials. While variation in cooling efficiency does not affect the yield when using a high-temperature treatment, uniform cooling efficiency is necessary avoid "inconsistencies/bends" in low temperature treatments. However it is difficult to increase temperature stabilization in low temperature treatments. In this paper, using CFD (Computer Fluid Dynamics), we analyze and manipulate the design and input of the low-temperature system to attempt to control for temperature variations within the quartz tube, of which airflow appears to be a predominant factor. This simulation includes variable inputs such as airflow rate, head pressure, and design manipulations in the S.C.U. (Super Cooling Unit).

질적 간호제공을 위한 간호단위 시범 운영 효과에 관한 임상적 연구 (A Clinical Study for Promoting Quality Nusing Care in a University Hospital)

  • 이애주;김선한;성영희;유순애;권인각;정연이;남혜경;권은정
    • 대한간호
    • /
    • 제32권5호
    • /
    • pp.66-77
    • /
    • 1994
  • The purpose of this study was to develop a new nursing unit which can meet changing health care needs, enhance patients' satisfaction and nurses' job satisfaction, and finally guarantee quality nursing care with present manpower. For this, one medical unit was selected as a unit for quality care. And one medical unit which is similar in staffing and patients' characteristics was selected as a control unit. To assess present problems and identify the remedies to the problems a hospital-wide survey and a workshop were performed. According to the survey results, educational programs and improvement of the facilities and equipment supply system, managereal support for interdepartmental cooperation and intensification of bed-side nursing care were adopted as main principles for operating model unit, This model unit was operated for 3 months from Sep. 1, 1992 to Nov. 30, 1992. To evaluate the effectiveness of the model unit, derect/indirect nursing care hours, patients' satisfaction to nursing care, nurses' job satisfaction, and quality care index were measured. Direct/indirect nursing care hours were compared with that of the control unit, and patients' and nurses' satisfaction and quality care index were measured before and after operating model unit and compared with each other. The results of the study were as follows; 1. In the model unit mean direct nursing care hours per cach shift was 146.88 minutes and indirect nursing care hours was 354.72 minutes. The ratio of the direct nursing care hour to indirect nursing hour was 29.6 ; 70.4 and that of the control unit was 26.9 : 73.1. Direct nursing care hour in model unit was longer than that of the control unit. But, the difference was not significant. In subcategories of direct nursing care, the time spent in mobility and exercise, conservation of body temperature, hygiene, and communication and health education were longer than that of the con" trol unit. 2. Indirect nursing care hour in model unit was shorter than that of the control unit. But, the difference was not significant. In subcategories of indirect nursing care, the time spent in drug management and ward arrangement was shorter than that of the control unit. 3. Patients' satisfaction to nursing care was increased significantly after operating the model unit (T=-3.48, P=-0.002) and satisfaction to subcategories of physical comfort measure, psychological cate, and unit management components were significantly higher than before. 4. In the model unit, nurses' total job satisfaction was increased significantly after operating the model unit(Z=2.1004, P=.0357) and satisfaction to subcategory of satisfaction to administration was significantly higher than before (Z=-2.0732, P=.0382). 5. After operating the model unit, quality care index was increased from 89 to 93. With this results, it can be summarized that all the measures tried for quality care, such as educational programs, managereal support for interdepartmental cooperation, and improvement of the equipment and facility provision resulted in partial increase in direct nursing care hours, nurses satisfaction to their job and patients' satisfaction to nursing care. In can be postulated that managereal support and motivation without proper staff supplementation is not enough for increasing direct nursing care hours. And for the enhancement of the level in clinical nursing, and staff supplement must be considered sincerely and the measures for reducing indirect nursing care hours, such as computerization of nursing care activities, improvement of facilities and equipment and facilities supply system, must be instituted in addition.

  • PDF

인테이크 도어 제어를 이용한 고성능 냉난방 시스템 (Air Intake Door Control for the High Air Conditioning Performance)

  • 박동규;김용철
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.17-22
    • /
    • 2014
  • Recently, the quick heating performance is an important issue in the car because engine power becomes so high. So car makers have been adapted the additional heating devices as like PTC(Positive Temperature Coefficient) heater. And the quick cooling performance is also important issue because its result is used in the IQS(Initial Quality Study). In this paper, control of the HVAC(Heating, Ventilation and Air Conditioning) intake door has been studied for the quick heating and cooling performance. Heating performance is improved $4.0^{\circ}C$ at $-20^{\circ}C$ ambient temperature after 20 minutes. And cooling performance is improved $1.5^{\circ}C$ at $35^{\circ}C$ ambient temperature after 10 minutes. In addition, intake door control system brings on the cost reduction because the flab door can be eliminated. This intake door control system has been adapted to the new developing cars.

일교차가 당뇨병성 창상의 치유에 미치는 영향: 동물 실험 연구 (Relationship between the Diurnal Temperature Range and Wound Healing of Diabetic Foot: Animal Study)

  • 원성훈;천동일;조재호;박인근;이영
    • 대한족부족관절학회지
    • /
    • 제24권4호
    • /
    • pp.142-147
    • /
    • 2020
  • Purpose: Diabetic foot ulcers are closely related to body surface heat, which can be affected easily by temperature differences. This study examined the correlation between the healing process of diabetic wounds and abnormal diurnal temperature through an animal study. Materials and Methods: Rats in the abnormal diurnal temperature group and control group were given a 10 mm sized full-thickness skin ulcer. Wound size progression was observed in both groups. H&E and Masson's trichrome staining was performed at 14 days after wound formation, and the number of vessels per unit area and histology analysis were performed. The changes in the ulcer were measured through three dimensional cross-section area using INSIGHT® devices. Results: The wound recovery period (granulation ingrowing) was 24 days in the abnormal diurnal temperature model and 20 days in the control group. The thickness of scar tissue was 402±23.19 ㎛ in the control group and 424.5±36.94 ㎛ in the diurnal temperature model. Neovascular formation was counted as 5.1±0.97 for the control group and 4.16±0.94 for the diurnal temperature model group. Conclusion: Delayed and inferior diabetic wound healing was observed in the abnormal diurnal temperature group, which was characterized by greater diurnal variations than the typical growth environment.

상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용 (Development of Smart Remote Terminal Unit for Water Treatment SCADA System)

  • 장상복;이호현;홍성택;전명근
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

Effect of Temperature and Relative Humidity on Growth of Aspergillus and Penicillium spp. and Biocontrol Activity of Pseudomonas protegens AS15 against Aflatoxigenic Aspergillus flavus in Stored Rice Grains

  • Mannaa, Mohamed;Kim, Ki Deok
    • Mycobiology
    • /
    • 제46권3호
    • /
    • pp.287-295
    • /
    • 2018
  • In this study, we evaluated the effect of different temperatures (10, 20, 30, and $40^{\circ}C$) and relative humidities (RHs; 12, 44, 76, and 98%) on populations of predominant grain fungi (Aspergillus candidus, Aspergillus flavus, Aspergillus fumigatus, Penicillium fellutanum, and Penicillium islandicum) and the biocontrol activity of Pseudomonas protegens AS15 against aflatoxigenic A. flavus KCCM 60330 in stored rice. Populations of all the tested fungi in inoculated rice grains were significantly enhanced by both increased temperature and RH. Multiple linear regression analysis revealed that one unit increase of temperature resulted in greater effects than that of RH on fungal populations. When rice grains were treated with P. protegens AS15 prior to inoculation with A. flavus KCCM 60330, fungal populations and aflatoxin production in the inoculated grains were significantly reduced compared with the grains untreated with strain AS15 regardless of temperature and RH (except 12% RH for fungal population). In addition, bacterial populations in grains were significantly enhanced with increasing temperature and RH, regardless of bacterial treatment. Higher bacterial populations were detected in biocontrol strain-treated grains than in untreated control grains. To our knowledge, this is the first report showing consistent biocontrol activity of P. protegens against A. flavus population and aflatoxin production in stored rice grains under various environmental conditions of temperature and RH.

온도 및 전류의 과도응답 제어가 가능한 SOA Driver에 관한 연구 (A Study on SOA Driver with Capability to Control Current and Temperature Transient Response)

  • 엄진섭
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2014
  • In this paper, SOA Current and Temperature Driver which consisted of LabVIEW programming part capable of current and temperature transient response pattern design, DAQ module for analog voltage in&out, and voltage to current converting chips has realized. The output current(possible to 3A) from the Driver to SOA was clearly constant without ripple and also showed no variance until 1mA unit for a long time operation. The temperature of TEC took several seconds to reach a set temperature, and were maintained stably within ${\pm}^0.1{\circ}C$ for several hours. The proposed Driver can replace the previous high cost SOA Drivers for wavelength swept lasers fully and provides the convenience of transient response design capability for current and temperature.

효모 세포 표면 발현된 Endoxylanase를 이용한 Xylooligosaccharides의 생산 (Production of Xylooligosaccharides by Yeast Cell Surface-Displayed Endoxylanase)

  • 김현진;이재형;김연희;남수완
    • 한국미생물·생명공학회지
    • /
    • 제36권4호
    • /
    • pp.307-313
    • /
    • 2008
  • Bacillus sp. endoxylanase 유전자(xynB, 642 bp)의 효모 표면발현계 pCTXYN(6.8 kb)를 구축하고 Saccharomyces cerevisiae EBY100에 형질전환시켜 형질전환체 EBY100/pCTXYN를 얻었다. 형질전환체들을 xylan이 포함된 YPDG 배지에서 배양 후 활성염색을 통하여 고찰성의 형질전환체를 최종 선별하였다. 갈락토스 배지에서 자란 효모 형질전환체로부터 xynB는 성공적으로 표면발현되었고, xylan으로 부터 xylooligosaccharides를 효율적으로 생성함도 화인하였다. Endoxylanase 활성은 세포분획에서만 검출되었고 배양 48시간에 최종 1.9 unit/mL의 활성을 보였다. Xylooligosaccharides 생산을 위한 치적 반응 조건으로, 기질과 농도는 oat spelt xylan 6%, 효모 생촉매 농도는 5 unit/mL, 반응온도는 $50^{\circ}C$, 반응시간은 $2{\sim}4$시간이었다 효모 생촉매를 oat spelt xylan과 corncob xylan에 처리한 결과, xylotriose가 주성분이었다.

가스 유량 계측 및 제어 시스템 연구 (Development of a Gas Flow Measurement and Control System)

  • 전학진;양종화
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 1996
  • This paper describes a system for measurement and control of a gas flow. In order to measure the flux of gas and control a vavle according to flux, this system was developed. This system is implemented on the personal computer and its environment is developed tool called TMS. This system includes a main program and Tele-Metering Unit for transmitting correcting flow value based on temperature and pressure in flow computer and AD converter for transmitting instantaneous flow rate, temperature and pressure as interface part of personal computer. This system was made by Visual C++ program. Using this system, inspected data for the recognition of transmitting flow value are generated on the screen, file and printer. The activity, reliability of this system was verified on Daegu-Citygas that aids the system for the acquisition of inspected data by realtime application.

  • PDF

바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석 (Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies)

  • 이준우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF