• 제목/요약/키워드: Temperature control unit

검색결과 406건 처리시간 0.026초

Solar Energy Powered Bicycle for Wireless Supervisory Control and Remote Power Management Applications

  • Chao, Chung-Hsing
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.111-115
    • /
    • 2012
  • In this paper, a solar energy powered bicycle linked to a wireless sensor network (WSN) which monitors the transfer of solar energy to an electrical energy storage unit and an analysis of its effectiveness is proposed. In order to achieve this goal, a solar-powered bicycle with an attached ZigBee and a far-end wireless network supervisory system is setup. Experimental results prove that our prototype, solar energy powered bicycle, can achieve enough solar energy for charging a two lead-acid battery pack. As a result, the user, through use of a wireless network in the parking period can be kept aware of the data on the amount of immediate solar radiation, the degree of illumination, the ambient temperature, and electrical energy storage capacity information of the bicycle through an internet interface.

Malus의 편광법칙을 이용한 EPAS용 비접촉 torque sensor 개발 (Development of the Non-Contact Torque Sensor for EPAS Using Maluss Polarization Law)

  • 노병옥;박호;강판식
    • 대한기계학회논문집A
    • /
    • 제25권7호
    • /
    • pp.1039-1046
    • /
    • 2001
  • Among the automotive steering systems, an Electric Power Assisted steering (EPAS) system utilizes an electronically controlled electric motor to provide steering assistance to the driver. The key components of the EPAS system are torque sensor, ECU (Electronic Control Unit), and DC Motor. The most important component of the EPAS is the torque sensor. The conventional torque sensor has complicated mechanical mechanism of torque detection. However, we suggest a non-contact torque sensor for EPAS using Maluss polarization law. It was found that the sensor exhibited not only excellent linearity but also superior characteristics of hysteresis, temperature and vibration.

공기 중 휘발성 유기화합물의 측정을 위한 열탈착-분석시스템의 구성 및 평가 (Composition and Evaluation of the Thermal Desorption-Gas Chromatographic System for the Measurement of Volatile Organic Compounds in Air)

  • 이수형;송희남;김희갑
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권1호
    • /
    • pp.63-71
    • /
    • 2002
  • The thermal desorption-gas chromatographic (TD-GC) system has been constructed for the measurement of volatile organic compounds. The thermal desortion unit is composed of four major parts: 1) the control part; 2) the thermal desorption part; 3) the focusing part; and 4) the injection part. The peltier element was introduced to the focusing part for the temperature of the focusing tube to reach-35$^{\circ}C$. The system was tested for the linearity of the calibration curves and reproducibility of instrumental analyses using some disinfection by-products (DBPs) and BTXs (benzene, toluene and p-xylene). The coefficients of determination (r$^2$) for all the calibration curves made were higher than 0.998, and the coefficients of variation (CV) for triplicate measurements were all within 10%. The system also has been tested for field applicability. The analysis of field samples showed that there was no breakthrough problem in the sampling system and that the system could be applied to field measurements.

평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발 (Development of a noncontact optical sensor for measuring the shape of transparent plates)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF

전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구 (A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors)

  • 강환국;김재진;김철주
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF

An Array-Based Sensor for Seafood Freshness Assessment

  • Gonzalez-Martin, Anuncia;Lewis, Brian;Raducanu, Marius;Kim, Jin-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3084-3092
    • /
    • 2010
  • This paper describes the development of an automated, hand-held sensor for the fast assessment of seafood freshness. The sensor developed here combined: an array-based chemical sensor, composed of incrementally different conducting polymer elements deposited on a small chip; a highly sensitive, custom-made electronics for the detection of very small signal changes; precise temperature control of the sensor chamber; and an on-board microcontroller for data collection, storage, automation, and analysis. The instrument was used to successfully test seafood samples with different degree of freshness and spoilage. A linear relationship between microbiological count and e-Nose signal for three different fish fillet was developed. Once the linear relationship is included into the hand-held unit software, the e-Nose signal can be used for assessment of seafood freshness without performing the microbiological count technique.

Development of Auxiliary Heater to Improve Korean Medical Evacuation Helicopter Winter Operational Capability

  • Kim, Se Un;Koo, Jeong Mo;Seo, Jeong Mi;Jeong, Won Chae
    • 항공우주시스템공학회지
    • /
    • 제14권6호
    • /
    • pp.10-17
    • /
    • 2020
  • The Korean medical evacuation helicopter was developed based on the Korean Utility Helicopter (hereafter referred to as 'Surion'). It uses an auxiliary power unit and engine for heating during winter operation. The helicopter maintains the internal temperature of the aircraft using its bleed air to satisfy its operational capability. However, due to the air inflow through the gap between the aircraft skin and door, additional heating for operating the portable medical equipment and preventing hypothermia in evacuated patients is required. Accordingly, an electric auxiliary heater was developed for additional heating during winter operation, and environmental, durability, and performance tests were conducted per MIL-STD-810G and MIL-STD-461F. The auxiliary heater was verified per the tailored airworthiness certification criteria.

광센서를 이용한 제상제어 방법에 대한 타당성 검토 (Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors)

  • 전창덕;김동선;이승준
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3389-3395
    • /
    • 2014
  • 제상제어 수단으로 사용하고 있는 일정 시간 제어방식, 온도차 제어방식 등은 종종 제상 오작동과 에너지 낭비를 가져오므로 좀 더 정확하게 제상을 제어할 수 있는 방법이 요구되고 있다. 수광부와 발광부로 구성된 광센서를 실외 열교환기 전방에 설치하여 서리의 유무에 따른 출력전압의 변화를 관찰함으로서 정확하게 제상제어를 할 수 있다. 본 연구에서는 기존의 일정시간 제상 방법을 사용하는 경우 나타나는 시스템 성능 및 특성 곡선을 광센서를 사용하여 재현가능한지 판단하기 위해 KS C 9306에 따른 난방 제상능력 시험조건(건구온도 $2^{\circ}C$/습구온도 $1^{\circ}C$)에서 실험을 수행하였다. 실험을 통해 측정한 난방능력, 소비전력, 열교환기 표면온도와 광센서 수광부 출력전압을 비교, 분석한 결과 제상 제어수단으로 광센서의 사용가능성을 확인하였다. 일정시간 제상방법을 통해 구한 제상 제어 단속 주기는 광센서를 통해 측정한 출력 전압의 단속 주기와 잘 일치하였다.

정부의 신종인플루엔자 A(H1N1) 대응 (National Level Response to Pandemic (H1N1) 2009)

  • 이동한;신상숙;전병율;이종구
    • Journal of Preventive Medicine and Public Health
    • /
    • 제43권2호
    • /
    • pp.99-104
    • /
    • 2010
  • The World Health Organization (WHO) announced the emergence of a novel influenza on April 24, 2009, and they declared pandemic on June 11. In Korea, the proportion of influenza-like illness and the consumption of antiviral agents peaked in early November. The government established the Central Headquarters for Influenza Control and operated the emergency response system. In the quarantine stations, we checked the body temperature and collected quarantine questionnaires from all the arrivals from infected countries. We also isolated the confirmed cases in the national isolation hospitals. However, as the community outbreaks were reported, we changed strategy from containment to mitigation. We changed the antiviral agent prescription guideline so that doctors could prescribe antiviral agents to all patients with acute febrile respiratory illness, without a laboratory diagnosis. Also the 470 designated hospitals were activated to enhance the efficacy of treatment. We vaccinated about 12 million people and manage the adverse event following the immunization management system. In 2010, we will establish additional national isolation wards and support hospitals to establish fever clinics and isolation intensive care unit (ICU) beds. We will also make a computer program for managing the national isolation hospitals and designated hospitals. We will establish isolation rooms and expand the laboratory in quarantine stations and we will construct a bio-safety level 3 laboratory in each province. In addition, we plan to construct a bio-safety level 4 laboratory at a new Korea Centers for Disease Control and Prevention (KCDC) facilities in Ossong.

Effects of Chilled Drinking Water on Performance of Laying Hens during Constant High Ambient Temperature

  • Gutierrez, W.M.;Min, W.;Chang, H.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제22권5호
    • /
    • pp.694-699
    • /
    • 2009
  • The present study was conducted to evaluate the effect of chilled drinking water on the productivity of laying hens under constant high ambient temperature. A total of seventy-two, 123-day-old Hy-line brown layers was divided into two equal groups. The first group (UDWG) was given unchilled water ($23.0{\pm}2.5^{\circ}C$) as a control, and the second group (CDWG) was given chilled water ($16.0{\pm}0.5^{\circ}C$). The laying hens were kept at $30^{\circ}C$ constant temperature with 50% relative humidity and were exposed to 17 h of light per day. Feed intake, egg production, egg quality (egg weight, shell weight, shell thickness, egg color, yolk color, and Haugh unit), and blood samples were collected and analyzed. The results showed that the feed intake of CDWG laying hens was significantly higher (11.64%) than the UDWG counterparts (p<0.01). Egg production of CDWG was also significantly higher (11.27%) than the UDWG counterparts (p<0.001). Furthermore, we observed that the CDWG laying hens had significantly higher (11.72%) levels (p<0.10) of blood calcium, with a corresponding value of 21.92 mg/dl compared to the UDWG hens (19.62 mg/dl). The higher calcium concentration in the CDWG animals may contribute to increased egg production. The CDWG laying hens also contained higher (12.53%) phosphorus concentrations in blood compared to the UDWG (4.22 mg/dl vs. 3.75 mg/dl), although not statistically different (p>0.10). Egg weight and egg quality were not affected by chilled drinking water. In conclusion, providing chilled drinking for laying hens under high ambient temperature improved feed intake and egg production.