• 제목/요약/키워드: Temperature calculation

검색결과 1,452건 처리시간 0.028초

KSTAR 운전시나리오에 대해 초전도자석 구조물에 발생되는 줄열 및 온도분포 계산 (Calculation of Joule Heat and Temperature Distribution Generated on the Superconduction Magnet Structure for the KSTAR Operation Scenarios)

  • Seungyon Cho;Jeong Woo Sa;Chang Ho Choi;KSTAR Team
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.56-59
    • /
    • 2002
  • Since the KSTAR magnet structure should be maintained at cryogenic temperature of about 4.5 K, even a small amount of heat might be a major cause of the temperature rising of the superconducting magnet structure. The Joule heating by eddy current induced on the magnet structure during the KSTAR operation was found to be a critical parameter for designing the cooling scheme of the magnet structure as well as defining the requirements of the refrigerator for the cryogenic system. Based on the Joule heating calculation, it was revealed that the bulk temperature rising of the magnet coil structure was less than 1 K. The local maximum temperature especially at the inboard leg of the TF coil structure increase as high as about 21 K for the plasma vertical disruption scenario. For the CS coil structure maximum temperature of 8.4 K was obtained from PF fast discharging scenario.

  • PDF

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

실효온도차법에 의한 최대열부하 계산용 온습도에 관한 연구 (Design Temperature and Absolute Humidity for Peak Cooling and Heating Load Calculation with ETD Method)

  • 김두천;서진석
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.278-284
    • /
    • 1993
  • A simplified TAC method was developed for the selection of design temperature and absolute humidity for peak cooling and heating load calculation with ETD method. And the design data of the 11 major cities in Korea were obtained. Based on the simplified TAC method, the design data for summer and autumn cooling season were selected by the TAC 5.0% of July through August and TAC 5.0% of October, respectively. But the design data for winter heating season were selected by the conventional TAC 2.5% of the full winter season.

  • PDF

탄소강 담금질시의 상변태열과 이를 포함한 냉각곡선의 계산 (The Latent Heat of Phase Transformation of the Carbon Steel and the Calculation of Cooling Curves Including the Latent Heat in Quenching)

  • 윤석훈;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.10-16
    • /
    • 1994
  • This study aimed at measuring the latent heat of phase transformation of S45C carbon steel in quenching and at conducting the analytical researches into the calculation of cooling curves including the latent heat. The temperature of phase transformation of steel and its latent heat are dependant upon the cooling rates at the temperature of A1 phase transformation point. The effect of the latent heat of phase transformation is especially manifest at the cooling curve of center of specimens. The higher the cooling rates became, the lower fell the temperature region of phase transformation. In the figures of cooling rates, the phenomena of cooling rate dropping into zero was caused by the latent heat of phase transformation.

  • PDF

SiC의 화학증착에 대한 열역학적 평형농도계산 (A Thermodynamic Calculation of Equilibrium Concentration for the CVD of SiC)

  • 서명기
    • 산업기술연구
    • /
    • 제5권
    • /
    • pp.73-79
    • /
    • 1985
  • Thermodynamic calculation for the CVD of SiC from methyltrichlorosilane(MTS) was done in some range of deposition condition to identify optimum condition. The results show that the most considerable chemical species are chloride and chlorosilane for silicon source and methane and acetylene for carbon source. In order to yield single phase ${\beta}$-SiC it is believed that optimum temperature range is between 1500 and $1700^{\circ}k$. With increasing temperature, stable phase is changed from Si+SiC phase to C+SiC phase. It is believed because equilibrium concentration of silicon source decrease and equilibrium concentration of carbon source increases with increasing temperature.

  • PDF

현열 플럭스 추정에 의한 대류 혼합층 고도의 산출 (Calculation of the Convective Mixed Layer by Estimation of Sensible Heat Flux)

  • 김용국
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.639-645
    • /
    • 1998
  • A Jump model was evaluated for the calculation of hourly mixing height and mean potential temperature within the height. The Sump model was modified for estimation of downward heat fluxes by mechanical convections and surface heat fluxes. The surface heat fluxes were estimated from routine weather data such as solar radiation and air temperature. Total of 8 upper-air data observed at 0000UTC and 0600UTC in Osan station during April 23 to 26, 1996 were analyzed, and compared to the model results in detail. The calculated mixing heights and potential temperatures within the height were comparable to the observations, but some differences were showed. The calculated mixing heights were generally higher than observations. And, when variations of wind directions were large, the large difference of potential temperature was occurred. From the results, it was important to note that vortical motions and advections of air masses would affect to the growth of the mixing height.

  • PDF

Experiment and Electro-Thermo-Chemical Modeling on Rapid Resistive Discharge of Large-Capacity Lithium Ion Battery

  • Doh, Chil-Hoon;Ha, Yoon-Cheol;Eom, Seung-Wook;Yu, Jihyun;Choe, Seon-Hwa;Kim, Seog-Whan;Choi, Jae-Won
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권3호
    • /
    • pp.323-338
    • /
    • 2022
  • Heat generation and temperature of a battery is usually presented by an equation of current. This means that we need to adopt time domain calculation to obtain thermal characteristics of the battery. To avoid the complicated calculations using time domain, 'state of charge (SOC)' can be used as an independent variable. A SOC based calculation method is elucidated through the comparison between the calculated results and experimental results together. Experiments are carried for rapid resistive discharge of a large-capacitive lithium secondary battery to evaluate variations of cell potential, current and temperature. Calculations are performed based on open-circuit cell potential (SOC,T), internal resistance (SOC,T) and entropy (SOC) with specific heat capacity.

Validation of Computational Fluid Dynamics Calculation Using Rossendorf Coolant Mixing Model Flow Measurements in Primary Loop of Coolant in a Pressurized Water Reactor Model

  • Farkas, Istvan;Hutli, Ezddin;Farkas, Tatiana;Takacs, Antal;Guba, Attila;Toth, Ivan
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.941-951
    • /
    • 2016
  • The aim of this work is to simulate the thermohydraulic consequences of a main steam line break and to compare the obtained results with Rossendorf Coolant Mixing Model (ROCOM) 1.1 experimental results. The objective is to utilize data from steady-state mixing experiments and computational fluid dynamics (CFD) calculations to determine the flow distribution and the effect of thermal mixing phenomena in the primary loops for the improvement of normal operation conditions and structural integrity assessment of pressurized water reactors. The numerical model of ROCOM was developed using the FLUENT code. The positions of the inlet and outlet boundary conditions and the distribution of detailed velocity/turbulence parameters were determined by preliminary calculations. The temperature fields of transient calculation were averaged in time and compared with time-averaged experimental data. The perforated barrel under the core inlet homogenizes the flow, and therefore, a uniform temperature distribution is formed in the pressure vessel bottom. The calculated and measured values of lowest temperature were equal. The inlet temperature is an essential parameter for safety assessment. The calculation predicts precisely the experimental results at the core inlet central region. CFD results showed a good agreement (both qualitatively and quantitatively) with experimental results.

케이블 열회로의 전기적 등가회로 변환을 이용한 케이블 허용전류 검토 방법 (A Review Method of Calculation Results on Cable Ampacity using the Transformation to Electric Equivalent Circuit from Cable Thermal Circuit)

  • 강연욱;김민주;장태인;박진우;박흥석;강지원
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.738-744
    • /
    • 2016
  • Current rating of a power cable can be calculated by the maximum allowable temperature in an insulating material considering the heat transfer from cable conductor. Therefore, it is very important to calculate the current rating using electrical equivalent circuit by calculated cable thermal circuit parameters but, it has not been fully investigated yet. In this paper, in order to determine the current rating of power cable, conventional calculation method has been reviewed considering the conductor resistance, loss factor of sheath, dielectric losses and thermal resistances based on the maximum allowable temperature of 345 kV $2500mm^2$ XLPE cable. To confirm the calculation result of the current rating, the conductor temperature should be examined whether it reaches the maximum allowable temperature by the thermal equivalent circuit of the cable. Then, utilizing EMTP (Electro-Magnetic Transient Program) which is a conventional program for electrical circuit, the thermal equivalent circuit was transformed to an electric equivalent circuit using an analogous relationship between thermal circuit and electrical circuit, and temperature condition including cable conductor, sheath, cable jacket could be calculated by the current rating of 345 kV $2500mm^2$ XLPE cable.

Structural Analysis of Species in NbCI5-EMIC Room-Temperature Molten Salt with Raman Spectroscopic Measurement and Ab Initio Molecular Orbital Calculation

  • Koura, Nobuyuki;Matsuzawa, Hidenori;Kato, Tomoki;Idemoto, Yasushi;Matsumoto, Futoshi
    • 전기화학회지
    • /
    • 제5권4호
    • /
    • pp.183-188
    • /
    • 2002
  • The structure of species formed in $NbCI_5-I-ethyl-3-methylimidazolium$ chloride (EMIC) room-temperature molten salt (RTMS) was examined with the Raman spectroscopic measurement and ab initio molecular orbital calculation. The equilibrium structures of $NbCl_5,\;NbCl_6^-,\;Nb_2CI_{10},\;Nb_2CI_{11}^-,\;Nb_3CI_6^-,\;NbCI_6^--EMI^+\;(in\;which\;NbCI_6^-$ anion approaches $EMI^+$ cation with strong interaction) and $Nb_2CI_{11}^--EMI^+$ were obtained with the HF/LANL2DZ level of calculation. The harmonic frequencies at each equilibrium structure were compared with Raman spectra. The harmonic frequencies of $NbCI_6^--EMI^+,\; Nb_2CI_{11}^--EMI^+,\;and\;Nb_2CI_{10}$ were in good agreement with the Raman spectra of RTMS melts. In the $NbCI_5-EMIC RTMS$, the main species were $NbCI_6^-\;and\;EMI^+$. In the $NbCl_5-EMIC$ RTMS added $NbCl_5\;over\;50mol\%$, small amount of $Nb_2CI_{11}^-\;and\; Nb_2CI_{10}$ were also formed. The structures of anions and cation in the RTMS distorted from free ions with Coulomb force.