• 제목/요약/키워드: Temperature Difference Control

검색결과 1,035건 처리시간 0.027초

테이핑 기법에 따른 가임기 여성의 월경통, 월경 증상 및 체온에 미치는 영향 비교 (Comparison of Effects of Taping Methods on Menstrual Pain, Menstrual Symptoms, and Body Temperature in Women of Reproductive Age)

  • 이은진;박재명;인태성;정경심
    • 대한정형도수물리치료학회지
    • /
    • 제29권2호
    • /
    • pp.31-38
    • /
    • 2023
  • Background: The aim of this study was to compare the effects of taping techniques on menstrual pain, body temperature, and menstrual symptoms in women of reproductive age. Methods: This study targeted 40 female students enrolled at G university with menstrual pain rated above 5 on the visual analog scale (VAS). The participants were randomly assigned to four groups: the Kinesio taping, spiral taping, non-steroidal anti-inflammatory drug, and control groups. The intervention was applied one day after the onset of menstruation, and menstrual pain, menstrual symptoms, and body temperature were measured before the intervention and 24 hours after the intervention application. We measured menstrual pain using the VAS. Additionally, we evaluated menstrual symptoms using the menstruation symptom scale and measured body temperature of the abdomen and feet using digital infrared thermal imaging. Results: After the intervention, all three experimental groups showed significant improvement in menstrual pain and menstrual symptoms compared to the control group, and there was no significant difference among the three groups. After applying Kinesio taping, there was a slight decrease in the temperature difference between the abdomen and feet, but no statistically significant difference was observed. Conclusion: The results of this study demonstrated that kisesio and spiral taping have similar effects as with anti-inflammatory medication in relieving menstrual pain and menstrual symptoms. Taping can be considered as an effective method to replace medications in order to alleviate menstrual pain.

  • PDF

경피신경전기자극이 지연성근육통의 교감신경활동에 미치는 영향 (The Effects of Transcutaneous Electrical Nerve Stimulation on Sympathetic Nerve Activity in Delayed Onset Muscle Soreness)

  • 박장성
    • The Journal of Korean Physical Therapy
    • /
    • 제14권1호
    • /
    • pp.109-115
    • /
    • 2002
  • This study conducts eccentric exercise ti non-dominant elbow flexor of 20 persons in order to examine the effects of transcutaneous electric nerve stimulation on sympathetic nerve activity in delayed onset muscle soreness, induces delayed onset muscle soreness, divides them into 10 persons respectively as experimental and control groups. And a stimulation for 2 min. with 100 pps is given to elbow flexor after repeated three times of 10 minutes rest, temperature, blood pressure and pulse are measured and as a result of two-way ANOVA, change of temperature didn't show a significant difference according to the elapse of times(p>0.05) and systolic pressure and pulses in showed a significant difference between experimental and control groups(p<0.05). These results suggest that transcutaneous electrical nerve stimulation has a direct or indirect influence on sympathetic nerve activity in delayed onset muscle soreness under a restricted condition of electrical stimulation.

  • PDF

A Billet Heat Transfer Modeling during Reheating Furnace Operation

  • Jang, Yu-Jin;Kim, Sang-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.863-868
    • /
    • 2004
  • Reheating furnace is an essential facility of a rod mill plant where a billet is heated to the required rolling temperature so that it can be milled to produce wire. Sometimes, it is also necessary to control a transient billet temperature pattern according to the material characteristics to prevent a wire from breaking. Though it is very important objective to obtain a correct information of a billet temperature during furnace operation. Consequently, a billet temperature profile must be estimated. In this paper, a billet heat transfer model based on FEM (Finite Element Method) with spatially distributed emission factors is proposed and a measurement is also carried out for two different furnace operation conditions. Finally, the difference between the model outputs and the measurements is minimized by using the new optimization algorithm named uDEAS(Univariate Dynamic Encoding Algorithm for Searches) with multi-step tuning strategy. Hence, the information of billet temperatures can be obtained by using proposed model on various furnace operation conditions.

  • PDF

An Estimation of a Billet Temperature during Reheating Furnace Operation

  • Jang, Yu-Jin;Kim, Sang-Woo
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권1호
    • /
    • pp.43-50
    • /
    • 2007
  • Reheating furnace is an essential facility of a rod mill plant where a billet is heated to the required rolling temperature so that it can be milled to produce wire. Although it is very important to obtain information on billet temperatures, it is not feasible during furnace operation. Consequently, a billet temperature profile should be estimated. Moreover, this estimation should be done within an appropriate time interval for an on-line application. In this paper, a billet heat transfer model based on 2D FEM(Finite Element Method) with spatially distributed emission factors is proposed for an on-line billet temperature estimation and also a measurement is carried out for two extremely different furnace operation patterns. Finally, the difference between the model outputs and the measurements is minimized by using a new optimization algorithm named uDEAS(Univariate Dynamic Encoding Algorithm for Searches) with multi-step tuning strategy. The obtained emission factors are applied to a simulation for the data which are not used in the model tuning for validation.

다단계 온도 감지막을 가진 고영역 흐름측정용 마이크로 흐름센서 (A Micro-Flow Sensor With Multiple Temperature Sensing Elements for Wide Range Flow Velocity Measurement)

  • 정완영;김태용;서용수
    • 제어로봇시스템학회논문지
    • /
    • 제12궈1호
    • /
    • pp.85-92
    • /
    • 2006
  • A new silicon micro flow sensor with multiple temperature sensing elements was proposed and fabricated in considering wide range flow velocity measuring device. Thermal mass flow sensor measures the asymmetry of temperature profile around the heater which is modulated by the fluid flow. A micro mass flow sensor was normally composed of a central heater and a pair of temperature sensing elements around it. A new 2-D wide range micro flow sensor structure with three pairs of temperature sensing elements and a central heater was proposed and numerically simulated by Finite Difference Formulation to confirm the feasibility of the wide flow range sensor structure. To confirm the simulation result, the new flow sensor was fabricated on silicon substrate and the basic flow sensing properties of the sensor were measured.

고강도 알루미늄 튜브의 온간 하이드로포밍 특성 (Warm Hydroforming Characteristics of High Strength Aluminum Tubes)

  • 이문용;강창룡;이상용
    • 소성∙가공
    • /
    • 제13권5호
    • /
    • pp.403-408
    • /
    • 2004
  • Hydroformability of 6061 and 7075 aluminum tube materials was studied by warm hydroforming experiments. A special tooling and heating system was designed and manufactured in order to perform warm hydroforming between room temperature and $300^{\circ}C$. The control of tube temperature for warm hydroforming was made by the control of temperature of oil medium. Warm hydroformability was analyzed by tube appearances, tube elongation and hardness values. Hydroforming characteristics of 6061 and 7075 tubes showed different temperature dependence between room temperature and $300^{\circ}C$. The difference in hydroformabilities of 6061 and 7075 at elevated temperatures was interpreted by the different sensitivity to dynamic strain aging of both aluminum materials.

감 재배지 간 과실 품질 차이에 관계한 기온요인 분석 (Analysis of Air Temperature Factors Related to Difference of Fruit Characteristics According to Cultivating Areas of Persimmon (Diospyros kaki Thunb.))

  • 김호철;전경수;김태춘
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.124-131
    • /
    • 2008
  • 본 연구에서는 감 재배지 간 과실 특성 차이에 관계한 기온 요인을 분석하고자 8개 단감 '부유' 재배지의 16개 기온요인과 과실 특성을 조사하여 주성분 및 다중회귀 분석을 실시하였다. 16개 기온요인 중 제1주성분은 12개 요인으로 이중 연 평균최저기온, 10월 평균기온, 연 평균최저극온, 생육기 평균기온의 영향력이 아주 높았다. 그리고 제2주성분은 4개 요인으로 4월에서 7월까지의 월 평균기온이었고 5월과 6월 평균기온의 영향력이 높았다. 이에 제2주성분까지 누적기여율은 91.4%로 재배지 간 기온 차이에 관여하는 기온 요인을 분석하는 데에는 충분하였다. 8개 재배지 중 5 재배지은 주요 기온요인이나 그 영향력에서 뚜렷한 차이를 나타내었다. 기온요인과 과실 특성 간 다중회귀분석에서 과고는 생육기 평균기온($X_8$) 겨울철 적산온도($X_6$) 영향을 뚜렷이 받으며 회귀식 $Y=150.55-5.375X_8+0.014X_6$을 나타내었고, 이 회귀식에 대하여 생육기 평균최저기온($X_9$), 적산온도($X_5$), 8월 평균기온($X_{12}$) 등이 영향을 주었다. 과경은 생육기 평균기온($X_8$, 부의 상관), 과육갈반정도는 생육기 평균최저기온($X_9$, 정의 상관), 과피색 $a^*$값은 연 평균최저기온($X_2$, 정의 상관)의 영향을 받는 것으로 나타났다.

충격장치의 반 능동 제어시스템 설계 (Semi-Actively Controlled Impact System Design)

  • 김동환;최문철;이교일
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.46-56
    • /
    • 1999
  • A semi-actively controlled impact system which adjusts an impulse exerted by the external impact is studies. The main control variables are internal pressure difference inside the cylinder and the shock absorber displacement while it travels. Compared to a conventional one so called a passive system with a variable orifice inside the cylinder, a semi-actively controlled system utilizes an external orifice controlled by a highly fast responding electrical proportional valve. This device overcomes the temperature and viscosity change due to continuous operating and keeps the desired pressure difference and displacement in every operation. In this article a new prototype impact system is designed and manufactured based on a semi-actively control system. Through computer simulations and experiments, we verify the possibility of controlling the shock absorber pressure and displacement. After investigating the control performance a modified semi-actively controlled system with better control performance is also proposed.

  • PDF

Burst형과 고빈도형 경피신경전기자극치료가 실험적 동통역치와 체온에 미치는 영향 비교 (A Study Comparing the Effects of Burst Mode and High Rate Mode Transcutaneous Electrical Nerve Stimulation on Experimental Pain Threshold and Skin Temperature)

  • 김선엽;최흥식;권오윤
    • 대한물리치료과학회지
    • /
    • 제2권2호
    • /
    • pp.465-479
    • /
    • 1995
  • We randomly assigned 61 healthy subjects(male 14, female 47) to compare the experimental pain threshold and skin temperature between high mode TENS and burst mode TENS. In this study, 61 subjects were divided into three groups ; high mode TENS(n=20), burst mode TENS (n=20), and control group(n=21). Experimental pain thresholds and skin temperatures were measured before, immediately after cessation of stimulation, and at 30 minutes post stimulation. Stimulation was applied to the dorsal surface of the forearm(L14, LI10). Pain thresholds were measured by chronaxie meter. Skin temperature were measured by electrical digital thermometer. The results are as follows ; 1. There were no statistical difference in the pain threshold and skin temperature at before TENS stimulation among the three groups(p>0.05). 2. The pain threshold and skin temperature in burst mode TENS group was significantly higher and longer effect than that in high mode TENS group and control group(p<0.01). 3. The pain threshold in burst mode TENS group decreased to prestimulation levels by 30 minutes poststimulation. 4. The skin temperature in burst mode TENS group decreased to prestimulation levels by 20 minutes poststimulation. 5. The skin temperature was significantly difference among three group at immediately after, and at 30 minutes poststimulation and the skin temperature in burst mode TENS group was significantely higher than that in two groups(p<0.001). 6. The increasing rate of pain threshold in high mode TENS group after immediately cassation of stimulation was 24.3%(p<0.001). 7. The increasing rate of pain threshold in burst mode TENS group after immediately cessation of stimulation was 93.5% (p<0.001).

  • PDF

PLC를 이용한 온실의 환경제어 (Control of Environments in Greenhouse Using Programmable Logic Controller)

  • 김동억;조한근;김형준
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.599-606
    • /
    • 1998
  • This study was carried out to develop the control system with PLC and its operating software and to investigate its control ability of greenhouse environments. Two experimental greenhouses were controlled by PLC and ON/OFF controller, respectively. In greenhouse controlled by PLC, target values of air temperature, relative humidity and $CO_2$ concentration were automatically changed. In warm-water heating, the variation of air temperature was reduced to $\pm$ $0.6^{\circ}C$ by the method of proportional-integration(PI) control with an inverter. In ventilation, the variation of air temperature was reduced, since windows open and close with multistage by mutual relation formula among the target, indoor, and outdoor temperature. Relative humidity at daytime was maintained with range of 35% to 55% by PLC controlled fogger. $CO_2$ concentration was automatically controlled from 300 to 800 $\mu$molㆍ$mol^{-1}$ according to amount of solar radiation. The suppling amount and frequency of nutrient solution were controlled by total integrated solar radiation. Difference in the yield of cucumber in the greenhouse controlled by PLC and by ON/OFF controller was not significant at the 5% level.

  • PDF