• Title/Summary/Keyword: Temperature Difference Control

Search Result 1,035, Processing Time 0.028 seconds

Community Structure of Benthic Macroinvertebrates in an Urban Stream with a Reservoir (저수지를 포함한 도시하천의 저서성 대형무척추동물 군집구조)

  • Kim, PilJae;Kim, JinYoung;Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.825-831
    • /
    • 2013
  • The Suwon stream which consists of a mountainous reach, an artificial reservoir and an urban reach provides benthic macroinvertebrates with various habitats. This study was conducted to find out the influence of reservoir sluice control and water quality on benthic macroinvertebrates community in the Suwon stream from June to August, 2011. As a result, substrate composition showed little difference between the upper site (S2) and the lower site of the reservoir (S3). At site S3, water velocity was fastest, and water temperature was lowest due to the intermediate depth discharge of the reservoir. Cheumatopsyche brevilineata which prefer fast water velocity was dominant at site S3. Some biotic indices (H', J, and R) of site S3 decreased significantly whereas Benthic Macroinvertebrate Index (BMI) showed little difference between site S2 and site S3. EPT showed a negative correlation with water temperature. The sluice control of the reservoir leaded variations of water velocity and temperature, and seemed to make the state of aquatic ecosystem worse.

A Study on the Skin Improvement Effect of Castanea crenata Inner Shell with Microneedle Therapy System (미세다륜침을 이용한 율피의 피부개선 효과연구)

  • Koo, Jin Suk
    • The Korea Journal of Herbology
    • /
    • v.37 no.2
    • /
    • pp.23-31
    • /
    • 2022
  • Objectives : The purpose of this research was to find out the efficacy of Castanea crenata Inner Shell (CCIS) on the skin by comparing the difference effect between only MTS (microneedle therapy system) and the CCIS essence application after MTS treatment. Methods : The present author performed once a week and total 3 times of MTS treatment. The treatment time took about 5 ~ 10 minutes and the depth of the needle was adjusted according to the participant's skin condition. In the control group, essence base was applied after MTS and in the experimental group, CCIS powder dissolved essence was applied. One week after each treatment, the change of skin condition was measured. Two weeks after the end of the clinical trial, the skin condition was checked again. Results : In the case of the test group and the control group, there was a significant decrease in thermography temperature and there was a significant increase in skin tone. In the case of pores and pigmentation, there was no significant difference on both group. In the case of moisture, there was a significant increase only in the test group. Conclusion : The MTS treatment itself showed good effects on thermography temperature and skin tone. But in the case of the moisture effect, it was much better when the CCIS essence was applied to the skin after MTS treatment. This study suggests that CCIS essence increases the efficacy of MTS on the point of moisture.

An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province (전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구)

  • Lee, Tai-Kang;Choi, Eun-Seok;Kim, Hang;Kim, Hyung-Ryul;Gi, No-Gab;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

Design of Temperature based Gain Scheduled Controller for Wide Temperature Variation (게인 스케줄링을 이용한 광대역 온도제어기의 설계)

  • Jeong, Jae Hyeon;Kim, Jung Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.8
    • /
    • pp.831-838
    • /
    • 2013
  • This paper focused on the design of an efficient temperature controller for a plant with a wide range of operating temperatures. The greater the temperature difference a plant has, the larger the nonlinearity it is exposed to in terms of heat transfer. For this reason, we divided the temperature range into five sections, and each was modeled using ARMAX(auto regressive moving average exogenous). The movement of the dominant poles of the sliced system was analyzed and, based on the variation in the system parameters with temperature, optimal control parameters were obtained through simulation and experiments. From the configurations for each section of the temperature range, a temperature-based gain-scheduled controller (TBGSC) was designed for parameter variation of the plant. Experiments showed that the TBGSC resulted in improved performance compared with an existing proportional integral derivative (PID) controller.

Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler (산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.429-435
    • /
    • 2011
  • In this study the operational characteristics of the temperature control system between an on-offemployed cooler and a bypass type cooler is analyzed. Currently an on-off controller employed coolerwhich is the industry's leading type on the market for industrial coolers is used. The new type cooler isused a bypass controller at discharge gas. The COP of the bypass controlled cooler with discharge gas is at least 8% higher than the on-off controlled cooler. The maximum COP difference is about 20%. Based on the results, the bypass control with discharge gas shows the possible temperature control with high precision.

SIMULATION OF A HYDRAULIC CONTROL SYSTEM FOR POWERSHIFT TRANSMISSION OF TRACTORS

  • Kim, D. C.;Lee, H. S.;Kim, K. U.;Y S. Nam
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.498-505
    • /
    • 2000
  • Performance of a hydraulic system is influenced by its working temperature. Therefore, it is very important to make the system perform uniformly in an entire range of the working temperature. In this study a simulation of a hydraulic control system for the powershift transmission of tractors was conducted and the effect of the temperature was investigated in terms of design conditions of the system. Results of the simulation are as follows. The hydraulic control system with a spring accumulator was found to be more convenient to control the shifting time than that with a gas accumulator. By returning the oil from the clutches to the system through a path between the filter and pump, the time delay due to the pressure difference between the low and high temperatures could be reduced. Therefore, it was recommended that the hydraulic control system for the powershift transmission of tractors must be equipped with a spring accumulator and a circuit to return oil from the clutches to the system through a path between the filter and pump.

  • PDF

A Sutdy on Improvement of Geomeric Accuracy by using Fuzzy Algorithm in Surface Grinding (퍼지 알고리즘을 이용한 평면연삭의 형상정도 향상에 관한 연구)

  • 천우진;김남경;하만경;송지복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.149-154
    • /
    • 1993
  • In heavy grinding that is on of the high efficient grinding method, meaningful deformation is generated by high temperature. So, after machining, geomeric error generated od the workpiece. The most important factor on the geometric error is temperature difference between upper layer and lower layer (T $_{d}$) . Relations between Td and grinding condition and maximum geometric error and grinding condition are obtained by experiment. This relations are used in fuzzy algorithm for improvement geometric accuracy. The main results are follows : (1) The linear relation between maximum geometric error and grinding condition is ovtained by experiment. (2) The linear relation between maximum temperature difference between upper layer and lower layer and grinding condition is ovtained by experiment. (3) Control peth of wheel for improvement geometric accuracy is obtained by using the fuzzy algorithm.m.

  • PDF

Development of Environmental Control System for High-Quality Shiitake Mushroom (Lentinus edodes (Berk.) Sing.) Production

  • Kwon, Jin-Kyung;Kim, Seung-Hee;Jeon, Jong-Gil;Kang, Youn-Ku;Jang, Kab-Yeol
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.342-351
    • /
    • 2018
  • Purpose: Recently, an increasing number of farms have been cultivating shiitake mushrooms using a sawdust substrate and a cooler/heater. In this study, an attempt was made to develop an environmental control system using a heat pump for cultivating high-quality shiitake mushrooms. Methods: An environmental control system, consisting of an air-to-water type heat pump, a thermal storage tank, and a radiator in a variable opening chamber, was designed and fabricated. The system was also installed in the cultivation facility of a farm cultivating shiitake mushrooms so as to compare the proposed control system with a conventional environmental control system using a cooler-condensing unit and an electric hot water boiler. Results: The uniformity of the environment was analyzed through environment measurements taken at several positions inside the cultivation facility. It was determined that the developed environmental control system is able to control the variations in temperature and relative humidity to within 1% and 3%, respectively. In addition, a maximum temperature difference of $30^{\circ}C$ (maximum of $35^{\circ}C$, minimum of $5^{\circ}C$) and a maximum relative humidity difference of 30% (maximum of 90%, minimum of 60%) can be attained within 30 min inside the cultivation facility through the cooling of the heat pump and heating of the radiator in a variable opening chamber. Thus, the developed control system can be used to cultivate high-quality shiitake mushrooms more effectively than a conventional cooler and heater. Conclusions: In comparison with a conventional environmental control system, the developed system decreased the yield of ordinary mushrooms by 65%, and increased that of high-quality mushrooms by 217%. This corresponds to a 16% increase in gross farm income. Consequently, the developed system is expected to improve the income of shiitake mushroom cultivating farms.

DESIGN OF A PWR POWER CONTROLLER USING MODEL PREDICTIVE CONTROL OPTIMIZED BY A GENETIC ALGORITHM

  • Na, Man-Gyun;Hwang, In-Joon
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.81-92
    • /
    • 2006
  • In this study, the core dynamics of a PWR reactor is identified online by a recursive least-squares method. Based on the identified reactor model consisting of the control rod position and the core average coolant temperature, the future average coolant temperature is predicted. A model predictive control method is applied to designing an automatic controller for the thermal power control of PWR reactors. The basic concept of the model predictive control is to solve an optimization problem for a finite future at current time and to implement as the current control input only the first optimal control input among the solutions of the finite time steps. At the next time step, this procedure for solving the optimization problem is repeated. The objectives of the proposed model predictive controller are to minimize both the difference between the predicted core coolant temperature and the desired temperature, as well as minimizing the variation of the control rod positions. In addition, the objectives are subject to the maximum and minimum control rod positions as well as the maximum control rod speed. Therefore, a genetic algorithm that is appropriate for the accomplishment of multiple objectives is utilized in order to optimize the model predictive controller. A three-dimensional nuclear reactor analysis code, MASTER that was developed by the Korea Atomic Energy Research Institute (KAERI) , is used to verify the proposed controller for a nuclear reactor. From the results of a numerical simulation that was carried out in order to verify the performance of the proposed controller with a $5\%/min$ ramp increase or decrease of a desired load and a $10\%$ step increase or decrease (which were design requirements), it was found that the nuclear power level controlled by the proposed controller could track the desired power level very well.

A Study on Cervical Curvature and Thermography in Some Neck Pain Patients (경항통 환자의 경추 만곡도와 체표열에 대한 연구)

  • Yang, Jae-Sun;Lee, Sang-Gyu;Lee, Chong-woo;Yeom, Seung-Ryong;Kwon, Young-Dal;Lee, Soo-Kyung;Song, Yong-Sun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.15 no.2
    • /
    • pp.105-105
    • /
    • 2005
  • Objectives : The purpose of this study was to investigate the correlation between cervical spine curvature and thermography on neck pain patients. Methods : The cervical spine curvature was assessed on lateral view of plain radiograph by three measurements(Depth of cervical curve, Method of Jochumsen, Angle of cervical curve), then the neck pain patients were divided into straight curvature group(Straight group), normal curvature group(Control I), and no neck pain group(Control II) was selected by random sampling. I measured temperature of the both side Pungji(風池, G20), Kyonjong(肩井, G21), Chonjong(天宗, SI11) by thermography examination on Experimental group(Straight group) and control group(Control I, II), then analyzed the temperature statically with student's t-test, ANOVA. Results : The temperature of six point on Straigt group was lower than that of Control I, but had no significant difference(p>0.05). The temperature of six point on Straigt group was lower than that of Control II. The descent of temperature on Lt. Pungji(風池, G20), Lt. Kyonjong(肩井, G21), Rt. Chonjong(天宗, SI11) had significance(p<0.05). There is no corelation between onset period and mean temperature of six points. Conclusions : Thermography represnets the presence of neck pain, but has no correlation with straight of cervical curvature.