• Title/Summary/Keyword: Temperature Check

Search Result 578, Processing Time 0.03 seconds

EVA Sheet and Butyl Rubber based Waterproofing·Anti-Corrosion Sheet for Corrosion Maintenance and Repairing in the Interior Side of the Large Steel Pipes in Water Treatment Facilities (상수도용 대구경 녹 발생 강관 내부의 보수 및 성능 유지를 위한 EVA 시트와 부틸고무를 합지한 자착식 방수방식 시트의 부착성능 평가)

  • An, Ki-Won;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • This study discusses the applicability of environmental friendly EVA based butyl rubber self-adhesive waterproof sheet designed to prevent corrosion of large scale pipes used in the water treatment facilities during th water treatment process. The experiments conducted tested the waterproofing sheet's adhesion strength on the steel surface of the pipes and checked for whether the material has the proper response properties against the various environmental conditions. In addition, it the sheet adhered to the steel pipe was to see if the adhesion hold against the water pressure due to the ingress of inflow water. Finally, the waterproofing sheet's adhesion strength was tested on a rusted steel surface to confirm whether the material has the necessary properties to secure stable adhesion strength and prevent corrosion of steel pipes at the same time during the process of installation or maintenance. As a result, the self-adhesive waterproof sheets showed that all attachments in the untreated, long term pressuring, immersion in chemical substance (hydrochloric acid, hypochlorous acid, sodium hydroxide), low temperature ($-20^{\circ}C$) conditions showed a adhesion performance of higher than 1.5N/mm, which is the performance standard of KS F 4934. Also, in the testing to check for the adhesion property against inverse water pressure, it was observed that the adhesion failure did not occur even up to $3.0N/mm^2$ pressure. Also, in the process of assessing the adhesion performance on rusted steel surface, specimens after 12 hours of corrosion treatment was shown to have 2.1N/mm, and specimens after 168 hours of corrosion treatment was shown to have 2.0N/mm adhesion strength performance.

Antimycotic Susceptibility Testing of Trichophyton Rubrum by Microculture Method (96-well microplate를 이용한 Trichophyton Rubrum의 항진균제 감수성검사)

  • Lee, Moo-Woong;Kim, Jong-Chul;Choi, Jong-Soo;Kim, Ki-Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.396-406
    • /
    • 1992
  • Various susceptibility tests have been used to determine minimal inhibition concentration(MIC) of dermatophytes. They have limitations to apply practically because they need long time to determine MIC. Authors examined MIC of T. rubrum to ketoconazole and itraconazole using 96-well microplate and 24-well macroplate by method of Granade and Artis and tried to check the possibility of this method on clinical application. Nine strains of T. rubrum from patients with dermatophytosis were used. Evaluations of the factors affecting MIC were also tried. The results were as follows. 1. Effect of inoculation density on determination time and MIC : Determination of MIC were possible in 4th days after inoculation at higher inoculation density Caborbance 2.0, 1.0) compared to 6th days at lower inoculation density(absorbance 0.5, 0.25). 2. Effect of incubation temperature on MIC : When incubating at $37^{\circ}C$, MIC were below 0.006-$0.04{\mu}g/ml$ to ketokckonazole and below 0.006-$0.04{\mu}g/ml$ to itraconazole while at $25^{\circ}C$ 0.08-$5.68{\mu}g/ml$ to ketoconazole and 0.006-$0.71{\mu}g/ml$ to itraconazole. Significant reduction of MIC was observed at $37^{\circ}C$ compared to $25^{\circ}C$. 3. Effect of container size on determination time and MIC : When incubating in 96-well microplate and 24-well macroplate, determination of MIC was possible in 4th to 6th days after inoculation in broth-containig 96-well microplate compared to 8th to 12th days in broth-containing 24-well macroplate. But no difference in MIC was observed between different container size. 4. Effect of media on MIC : When using broth as media, MIC were below 0.006-$5.68{\mu}g/ml$ to ketoconazole, below 0.006-$0.36{\mu}g/ml$ to itraconazole in broth-containg 24-well macroplate. When using agar as media, MIC were below 0.006-$5.68{\mu}g/ml$ to ketoconzole, below 0.006-$5.68{\mu}g/ml$ to intraconzole in agar-containing 24-well macroplate. There was slight increase of MIC with agar media compared to broth media. 5. These findings confirm that determination of MIC of dermatophtes by method of Granade and Artis is fast and simple technique for antifungal susceptibility test.

  • PDF

INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS (Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과)

  • Song, Gwang-Chul;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study is to investigate the sterilization effect of Er:YAG laser against the intraoral acid producing bacterium, S. mutans, by irradiating the culture solution containing S. mutans KCTC 3065 with Er:YAG laser having a $650{\mu}m$ diameter beam through the non-contact method. We obtained the following results after examining the temperature changes of the culture solution, numbers of bacterial colonies, and acid-producing ability and attaching ability on teeth by measuring the amount of extracellular polysaccharide produced by S. mutans. The number of bacterial colony was decreased in $10{\mu}l$ culture solution irradiated with laser in overall compared to the control solution. The number decreased as the irradiation intensity and pulse repetition rate were larger and as the exposure time was increased. However, it did not change significantly in $100{\mu}l$ culture solution compared to the control solution. Although the acid-producing ability of S. mutans was inhibited for a certain duration after laser irradiation in 10r1 bacterial culture solution, it did not change in $100{\mu}m$ solution compared with the control solution. The amount of extracellular polysaccharide synthesized by S. mutans was partially decreased through laser irradiation in $10{\mu}m$ culture solution but did not change in $100{\mu}m$ culture solution. Based on these findings, we concluded that Er:YAG laser has an sterilization effect on S. mutans in which we presume that the mechanism is through the heat effect rather than the mechanical effect from development of ultrasound.

  • PDF

Quality Improvement of High Volume Fly Ash Concrete due to Early Strength Gain Admixture (조강형 혼화제에 의한 플라이애시 다량 치환 콘크리트의 품질 향상)

  • Han, Cheon-Goo;Park, Jong-Ho;Lee, Joung-Ah
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.117-124
    • /
    • 2009
  • The purpose of the study was to improve quality of high volume fly ash concrete. The study evaluated on the possibility of early quality improvement of high volume fly ash concrete with early strength gain admixture ('GA' below) developed by the preceding research. The study regarded applying naphthalene admixture ('NA' below) to mix proportion substituting FA 15 % to be plain. In the event of substituting FA 20, 25 and 30 %, the study compared engineering properties of concrete with plain by applying GA. Because of features of fresh concrete, fluidity falls down when GA is applied. Therefore, its use amount shall be increased. Only, in W/B 60 %, it was beneficial since slump loss was reduced about 35~70 mm than plain. The study could see that AE use should be increased proportionally since air content was reduced by coming from AE absorption operation of unburned coal content included in FA according to an increase in the amount of FA use. Reduction effect of bleeding could be anticipated since the amount of bleeding appeared at least in FA 20 %. Because of hardened concrete, time of setting appeared in the same level as plain when GA was applied. Therefore, it is judged that delay of setting can be reduced. In compressive strength, the study could check the same strength development as plain when GA was applied, having nothing to do with W/B and curing temperature. However, it is thought that we shall pay attention to GA use in the event of FA 30 % substitution. Freezing and melting resistance had less early value than plain. However, it is judged that there will be no problem of frost resistance since there is no a large difference between freezing and melting resistance and plain in overall. In accelerated neutralization, it was analyzed that a problem of weakening in neutralization appointed as a demerit when FA was applied in mass in proportion with GA use could be settled to some extent.

  • PDF

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

A Study on the Sanitary Status at Various Types of Restaurants in Changwon City (창원시 식품접객업소의 위생실태에 관한 조사연구)

  • 이경혜;류은순;이경연
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.4
    • /
    • pp.747-759
    • /
    • 2001
  • The sanitary status of 264 restaurants was investigated to develop a program of sanitary education at restaurants for improving sanitary levels of restaurant and consumers’ food safety. This investigation was performed through direct interviews on general items and sanitations for employees, facilities, equipments and food treatment. The restaurants are grouped into four different types according to the food served: Korean style food, Japanese style raw fish, roasted ribs, and western style food. It is found that sanitary education for employees are conducted at 66.5% of the total restaurants. The highest percentages are obtained by Korean style food restaurants (83.1%) and the lowest by western style food restaurants (55.6%).Washing facilities for employees are equipped at only 66.8% of the total restaurants. In the personal sanitation, 96.6% of the employees wash their hand after touching a dirty stuff, 77.5% after touching money and 57.1% after using telephone. It is also revealed that during food preparation shoes, overgarments, and caps are worn by 58.5%, 55.5%, and 20.6% of the employees, respectively. 73.5% of the restaurants are equipped with dish storages facilities while only 59.2% of restaurants have sterilizers for dishes. Also, chopping boards are sterilized more than once a week by 74.8% of them and knives everyday by 71.6%, 15.4% of restaurants sterilize their knives only once a week. 56.8% of restaurants check temperatures of the refrigerators and 26.2% of restaurants do not even sterilize the refrigerators. 31.8% of restaurants sterilize the kitchens with sodium hopochlorite after cooking. 93.3% of the restaurants store the raw food and the cooked foods separately. 49.8% of the restaurants refroze thawed food and 19.4% of the restaurants reuse leftovers. The frozen foods are thawed at room temperature by 49.4% of the total restaurants and 66.7% of the roasted rib restaurants.

  • PDF

Performance Status of Sanitary Management of School Food Service in the Jeonnam Area (전남지역 학교급식의 위생관리 실태)

  • 고무석;정난희;이전옥
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.51-67
    • /
    • 2004
  • This study analyzed the effects of nutrition technicians' hygiene education on cooking workers' performance of hygiene management in order to ensure the security of school meals. The situation of cooking workers' disposition in subject schools was elementary school(51.1%) and middle school(48.9%) and the type of meals was rural area type(54.2%), urban type(36.5%). and island and isolated area type(9.3%). The methods of meals management were single cooking(88.2%) and joint cooking and management(11.8%). The type of distributing meals was distributing in a dining room(93.5%), in a classroom(3.7%), and in both dining room and classroom(2.8%). Nutrition technicians' employment form included regular(53.5%) and daily(88.2%). Their education was junior college graduate(50.2%), university graduate(44.8%). and graduate school students(5.0%). Cooking workers' employment form included daily(88.2%) and regular (11.1%). suggesting that most were regular. Most cooking workers(77.4%) had at least high school certificate. Regarding the situation of cooking workers' disposition in subject schools, the number of student per one cooking worker was found as 91-120(37.2%), 61-90(22.6%). 60 and under(21.l %). 121-15006.7%). and 151 and over(2.5%). Cooking workers' level of performance of hygiene management was post-working stage(66.37/75 marks), pre-working stage(64.22/75 marks). and working stage(20.34/25 marks), The counting of meals articles in a pre-working stage(20.34/25 marks). temperature and required time in a working stage(18.78/25 marks), and machinery equipment and hygiene in a pre-working stage(21.40/25 marks) showed lowest of performance, which suggest poor service of hygiene. Cooking workers' performance of hygiene management by working stage showed the significant difference with school class(p<.001), type of schools with meals(p<.05). state of cooking workers' employment(p<.001), and cooking worker's disposition(p<.05). A working stage showed the significant difference with type of schools with meals(p<.05). A post-working stage showed the significant difference according to type of schools with meals(p<.05), and the methods of meals management(p<.05), and cooking workers' disposition(p<.05). In the execution of hygiene education, individual hygiene was highest(94.8%), followed by the management of machinery equipment and tools(89.7%), food poisoning and microorganism(94.7%), and the method of food treatment(76.4%). A yearly plan of hygiene education included established(83.9%) and not established(l6.1%). Regular education included not executed(25.1%), 2-3 times a month(l6.1%), and more than 4 a month(4.0%) and occasional education was not executed(57.0%), 1-3 times a month(26.3%), and more than 4 a month(l5.7%). In the methods for hygiene education, oral education(95.7%) was used most, followed by demonstration(10.5%), poster/photo(10.5%), video/slide(3.7%), and computer(3.7%). Frequency of improvement and complement of hygiene education included once a month(56.3%), once a year(20.7%), by quarter(l1.5%), and every six months(1l.5%). Newspaper was used most in materials of hygiene education, followed by internet, TV, nutrition technician's reeducation, information exchange between members, educational office's training, and reference book, and educational office's material. and symposium. Cooking workers' assessment of the effect of hygiene education was conducted through observation(56.8%), check table(l5.2%), question(l4.0%), and examination(14.0%). The reason of cooking workers' low level of performance included habitual custom(53.9%), lack of understanding(20.4%), overwork(l4.6%), and lack of knowledge(l1.l%) and the reason of difficulty in hygiene education included lack of time(55.3%), lack of understanding(27.6%), lack of knowledge and information(8.7%), and lack of budget(48.0%).

  • PDF

Characteristics of Tillering as Affected by Light intensity in Dasanbyeo, an Indica/Japonica High Yielding Rice Cultivar (광도 변화에 따른 다산벼의 분얼경 발생 특성)

  • 김덕수;양원하;신진철;김제규;류점호
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.3
    • /
    • pp.151-158
    • /
    • 2002
  • In Korean high yielding varieties developed by crosses between indica and japonica rice, the most limiting factor for yield increase may be attributed to the less number of tillers per unit area. The goal of this study is to find out the effect of the environmental factors as well as cultivation practice on the development and increase of tillers of Dasanbyeo, the high yielding indica / japonica hybrid cultivar. The effect of temperature was examined with 3 different light intensity, 220,600, and 1220 $\mu$㏖/s/$m^2$, respectively. For all the experiments, the leading japonica variety in Korea, Hwaseongbyeo, was used fur the check cultivar for the comparison with Dasanbyeo. The increase of the tillers was more prominent in Dasanbyeo than in Hwaseongbyeo at 220 $\mu$㏖/s/$m^2$ of light intensity, while the similar increase of tiller no. was found at 600 $\mu$㏖/s/$m^2$ of light intensity treatment. However, Hwaseongbyeo showed more rapid increase of tiller at 1220 $\mu$㏖/s/$m^2$ of light intensity. The mean number of the primary tiller ranged 5 to 7 in Dasanbyeo, and 2 to 7 in Hwaseongbyeo, showing greater variation in the latter case. However, the secondary tiller number ranged from 2 to 13 for the former, and 2 to 12 for the latter. The earliest initiation of tiller node of Dasanbyeo and Hwaseongbyeo was observed on 6 and 4 days after transplanting(DAT), respectively, at 600 $\mu$㏖/s/$m^2$ of light intensity, while 10, and 7 DAT, respectively, at 1,220 $\mu$㏖/s/$m^2$. No cultivar difference was observed at 600 $\mu$㏖/s/$m^2$ with the 18 DAT. The ratio of effective tiller was lower in Dasanbyeo, ranging from 47 to 55% than in Hwaseongbyeo, ranging from 72 to 100%.

A Study on the Correlation Analysis of EEG and Vibraimage due to Auditory and Olfactory Stimulation (청각 및 후각자극에 의한 뇌파(EEG)와 진동이미지기술의 상관성 분석에 관한 연구)

  • Kim, Jung-Min;Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4291-4297
    • /
    • 2015
  • EEG has been used to measure the emotion of amenity and discomfort in the interior space. EEG is limited to the experiment, because it is a equipment of contact type. However, Vibraimage can measure the emotion with a web camera. Because Vibraimage is a equipment of non-contact type, it is more suitable for the interior space than EEG. Therefor, it tries to find a correlation variable between EEG and Vibraimage to measure the human emotions. In this study, it were analyzed correlation of EEG and vibraimage due to variation of loudness 60[dB], 90[dB] and rosemary, jasmine scents. Check the health status of subjects who were selected 3 male students, and the period of this experiment was about months. The condition of the environmental test room was in temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux]. It were analyzed correlation of twenty-three index of EEG(absolute ${\theta}$, relative ${\theta}$, absolute $S{\alpha}$, relative $S{\alpha}$, absolute ${\alpha}$, relative ${\alpha}$, absolute ${\beta}$, relative ${\beta}$, absolute $\gamma$, relative $\gamma$, absolute $F{\alpha}$, relative $F{\alpha}$, absolute SMR, relative SMR, $SMR/{\theta}$, $SMR+M{\beta}/{\theta}$, absolute $H{\beta}$, relative $H{\beta}$, $H{\beta}/{\alpha}$, absolute $M{\beta}$, relative $M{\beta}$, SEF50, ASEF50) and ten index of Vibraimage(Aggression, Stress, Tension/Anxiety, Suspect, Balance, Charm, Energy, Self regulation, Inhibition, Neuroticism). As a result, I was found that relative ${\gamma}$ index of EEG and neuroticism index of Vibraimage have a high correlation as (${\pm}$).414 and (${\pm}$).424.

A study for diagnosis and pattern identification of Hwa-Byung (화병의 진단 및 변증유형에 관한 연구)

  • Lee, Hui-Young;Park, Jong-Hoon;Whang, Wei-Wan;Kim, Jong-Woo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.1
    • /
    • pp.1-17
    • /
    • 2005
  • Objective : This empirical research is performed to recognize diagnostic concept, pattern identification, and clinical features of Hwa-byung. In other words, the aims of this research are to examine the differences of the diagnosis between Hwa-Byung and the other psychiatric disorders, and to find out pattern identification, and clinical characteristics of Hwa-Byung for prescriptions of this syndrome. Method : In the experiment, there were participated 30 patients who were met for our criterions according to HBDIS (Hwa-Byung Diagnostic interview Schedule). These patients were diagnosed as Axis1 according to criterions of DSM-IV with administering SCID-I. OMS-prime was utilized for finding out pattern identification of oriental medicine. Symptom Check List-90-Revision(SCL-90-R), Hemilton rating Scale for Depression(HRSD), Heart Rate Variability(HRV), and Digital Infrared Thermographic imaging(D.I.T.I.) were also utilized to discover clinical characteristics of Hwa-Byung Patients. Results : 1. Regarding Sex-ratio, male subjects were 3(10%), and female subjects are 27(90%). The age of subjects ranged from 22 year old to 75 $(51.87{\pm}11.04;\:Mean{\pm}SD)$ 2. In the results of diagnosis on the basis of DSM-IV, the 17(56.67%) patients were MOD (Major Depressive Disorder), the 5(16.67%) patients were USD (Undifferentiated Somatoform Disorder), the 4(13.33%) patients were Dysthymic Disorder, the 3(10%) patients were GAD (Generalized Anxiety Disorder), and the 1(3.33%) was Panic Disorder. Two of the patients who diagnosed as MOD were diagnosed as Panic Disorder too, and one of them was diagnosed as Pain Disorder too. 3. Regarding pattern identification, Hwa-Byung is positively correlated to deficiency of Heart(心). and then to stagnancy of Liver-Gall bladder. Hwa-Byung is correlated deficiency symptom-complex rather than excessiveness symptom-complex. That is also correlated positively to Pathological heat and fire. 4. In SCL90-R, the mean of PSDI was $(75.3{\pm}10.7;\:Mean{\pm}SD)$. The each mean of the other 11 factors was distributed between50-70. 5. The mean of HRSD was $(17.9{\pm}5.6;\:Mean{\pm}SD)$ in the entire subject's group. Then the group of MDD was $20.9{\pm}4.4$ and the group of USD was $12.0{\pm}4.8$ 6. In the results of HRV. the mean of TP is $972.4{\pm}1174(Mean{\pm}SD)$, this is lower than normal range 1000-200. The other factors were within normal range. Then, there were no significant differences between them (p<0.05). 7. The temperatures of each acupoint have significant differences between HNl(印堂) and PC6(內關), between CV17(顫中) and PC6(內關), between HN1(印堂) and CV8(神闕), between CV17(顫中) and CV8(神闕) in comparison with the average of body temperature in the use of D.I.T.I. (p<0.01) 8. In the analysis of correlation between SCL-90-R, HRSD, HRV. and D.I.T.I. there were no significant results. According to results that the correlation was analyzed with only the MDD group as subjects, there was negative correlation between RMSSD of HRV and HRSD, between LF of HRV and PDSIof SCL-90-R, and between LF/HF of HRV and ANX, PSY, and PDSI of SCL-90-R. Conclusion : In the observation of clinical features of 30 cases of Hwa-Byung patients by using diverse structured tests, there could make diverse diagnosis as depressive disorder, anxiety disorder, and Somatoform Disorder. Particularly. MDD was highly distributed. Considering oriental medicine's pattern identification of Hwa-Byung, this syndrome is related strongly to Heart, and there were demonstrated deficiency symptom-complex, and Pathological heat and fire. One of the limits of this study is lack of control subject's group, therefore, in the future study, it requires reexamination through a comparative research with these data to complete this study.

  • PDF