• Title/Summary/Keyword: Telemetry data

Search Result 253, Processing Time 0.027 seconds

Development of Home-care Medical Information System integrating Telemetry (Telemetry를 통합한 재택 진료시스템의 개발)

  • Ham, J.H.;Chee, Y.J.;Yim, S.H.;Park, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.295-298
    • /
    • 1997
  • We developed the system that enables patients to be treated at home during their daily life through digital telemetry and public communication line. This system records and transfers ECG signals through wireless digital telemetry unhindering the patient's normal activities in long-term recording, and transmits the processed data, which enables real-time remote examination via ISDN phone line. Patient's image, voice, and transmitted signals are transferred to medical experts in remote medical center interactively.

  • PDF

The Development of Network-based Telemetry System for Railway Catenary Inspection (전차선로 검측을 위한 네트워크 기반 델레메트리 시스템 개발)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Park, Hyun-Jun;Choi, Won-Seok;Kim, Eung-Kwon;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.478-479
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed. In this paper, we proposed network-based telemetry system for condition monitoring in railway and acquired data from any kind of sensor in catenary line and structure at high voltage. This development gives the solution for online condition monitoring in railway. To check the validity of our approach in terms of application, we realized network-based telemetry System.

  • PDF

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF

Modeling of Reaction Wheel Using KOMPSAT-1 Telemetry (KOMPSAT-1 Telemetry를 활용한 반작용휠 모델링)

  • Lee, Seon-Ho;Choi, Hong-Taek;Yong, Gi-Ryeok;Oh, Si-Hwan;Rhee, Seung-U
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.45-50
    • /
    • 2004
  • The design of reaction wheel control logic is critical to achieve the spacecraft attitude stabilization and performance requirements for the successful mission. Due to various uncertainties on orbit there exist limitation to obtain the model parameters through the ground tests and to design the associated control logic. Thus, the model parameter correction using on-orbit data is essential to the control performance on orbit. This paper performs the system identification using KOMPSAT-1 telemetry data and extracts the model parameters of the reaction wheel. Moreover, the reaction wheel is remodeled and compared with the ground test results.

Development of the second Telemetry and the External Management System for Total Artificial Heart (인공심장용 2차 무선정보전달장치와 외부 관리 시스템의 개발)

  • Yi, S.W.;Choi, J.H.;Lee, J.H.;Lee, J.J.;Om, K.S.;Ahn, J.M.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.243-244
    • /
    • 1998
  • The second telemetry is designed for supplying additional function which the first telemetry system doesn't have and as a part system of the External Management System (EMS). It makes a patient and an animal move more freely with wireless communication at a distance of free activity from the PC and can get most data from the first telemetry to send to the PC. Recently, our laboratory is developing a RF system for the second telemetry.

  • PDF

The Development of a Telemetry System for ALQ-X (ALQ-X 전자방해체계용 원격전송 장치 개발)

  • Nam Yun Kwon;Lee Byeong Nam;Lee Seung Geun;Lyu Jeong Ho;Lee Dong Keun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.1 s.20
    • /
    • pp.56-61
    • /
    • 2005
  • A novel method for telemetering flight operational data of airborne jammer to ground station is presented. The design and construction of an onboard telemetry transmitting set and a ground receiving set which are necessary for realizing this novel method is described. Using this novel method, ALQ-X, airborne jammer, can immediately transmit the gathered data during flight without additional exclusive telemetry set.

Implementation of A 30-Channel PCM Telemetry Encoder with A TMS320F2812 DSP Chip (TMS320F2812 DSP 칩을 이용한 30채널 텔레메트리 엔코더 구현)

  • Kim Jung-Sup;Jang Myung-Jin;Shi Kwang-Gyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9A
    • /
    • pp.920-927
    • /
    • 2006
  • There are three critical considerations in developing a PCM telemetry encoder to be installed in an artillery projectile. The first is the performance consideration, such as sampling rate and data transmission rate. The second is the size consideration due to the severely limited installation space in an artillery projectile and the last is the power consumption consideration due to limitations of the munition's power supply. To meet these three considerations, the best alternative is a one-chip solution. Using a commercially available TMS320F2812 DSP, we have implemented a 30-channel PCM telemetry encoder to process randomized data frames, composed of 16-channel analog data, 14-channel digital data and 2-frame synchronization channels per data frame at 10Mbps transmitting baud rate.

Telemetry Data Downlink Management of Low Earth Orbit Satellite (저궤도위성 원격측정 데이터 다운링크 관리)

  • Chae, Dongseok;Yang, Seung-Eun;Cheon, Yee-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.111-116
    • /
    • 2013
  • Because LEO (Low Earth Orbit) satellite has very limited contact time between satellite and ground station, all telemetry data generated on satellite are stored in a mass memory and transmitted to the ground during the contact time. There are two downlink modes, real-time mode and playback mode. Only real-time data frames are transmitted to the ground in real-time mode, real-time and playback data frames stored into mass memory are transmitted to the ground in playback mode. In accordance with the data transmission rate, there are two downlink rates, low downlink rate and high downlink rate. This paper briefly introduces downlink interfaces and flight software of a LEO satellite developed in KARI. And it presents the telemetry storage method, real-time and playback downlink management method, and downlink channel and rate control method.

The Telemetry Transmitter with Variable Data rate Transmission (가변 데이터 전송 가능한 텔레메트리(Telemetry) 송신기)

  • Kim, Jang-Hee;Hong, Seung-Hyun;Park, Byong-Kwan;Kim, Bok-ki;Kim, Hyo-Jong
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • In this paper, We have studied the structure of a Telemetry Transmitter capable of transmitting variable data rates. This paper proposed a structure combining variable pre-modulation filter with cutoff characteristic with variable input sample rate converter. Variable pre-modulation filter has the same characteristics as pre-modulation filter and is converted to a constant sampling rate without structural changes according to the variable input data rate. We propose a software program that actively controls variable pre-modulation filter and variable input sample rate converter to respond to real-time changing data.

Telemetry capsule for pressure monitoring in the gastrointestinal tract (소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현)

  • Yoon, Ki-Won;Woo, Sang-Hyo;Lee, Jyung-Hyun;Moon, Yeon-Kwan;Park, Hee-Joon;Won, Chul-Ho;Kim, Byung-Kyu;Choi, Hyun-Chul;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.