• Title/Summary/Keyword: Teflon Resin

Search Result 53, Processing Time 0.027 seconds

Health Monitoring of Composite Plates (복합재료 평판의 헬스 모니터링)

  • Kim Dang-Won;Chun Heoung-Jae;Yi Choong-Hee;Byun Joon-Hyung;Um Moon-Kwang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.15-20
    • /
    • 2006
  • Real time health monitoring system was studied to detect the . generation of defects in the composite structures during service life. The PZT sensors were embedded into the woven-glass/phenol composite plate during the fabrication. VARTM (Vacuum Assisted Resin Transfer Molding) process were used to fabricate the composite plate. A Teflon tape was embedded between glass fiber layers to mimic delamination induced during service. Normalized maximum amplitude and energy analyses were used for the acquired signals. Both amplitude and energy of acquired signals were extremely sensitive to the delamination. Therefore, it was successful to detect and to locate the defects in composite plate by monitoring signals from sensors and using the proposed method.

  • PDF

Surface Discharge Characteristics in Different Media (이종절연재의 연면절연특성)

  • Shin, Sung-Ha
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.2
    • /
    • pp.49-54
    • /
    • 2012
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability and safety are being required. This paper reviews a basic data of the surface discharge characteristics for teflon resin in not only pure $N_2$, $N_2:O_2$ mixture gas and Dry-Air as being focused on environmentally friendly insulating Gas also $SF_6$. Used electrodes are Knife to Knife. With the changing distance of electrodes and pressure, we can find it, surface discharge voltages and surface dielectric strengths, respectively. Surface discharge Voltages of $N_2:O_2=80:20$ mixture gas are more higher than the $N_2:O_2$ Mixture gases.

Proposal of new dental color system through color research of restorative materials

  • Oh, Yun-Jeong;Choi, Yong-Jin;Noh, Eun-Young;Park, Geol;Oh, Won-Mann;Hwang, In-Nam
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.610-610
    • /
    • 2003
  • The purpose of this study was to propose a new dental color system through color evaluation of generally used dental composite and porcelain. In this study, Vita Omega 900 dental porcelain and 10 kinds of composite resins were used. A disk specimens(15mm diameter, 4mm thickness) of each material/shade combination were made. Resin compasite was condensed into Teflon mold and pressed between glass plates to flatten the surface. Pressed compasite was polymerized using an Optilux 501(Demetron, USA) for 200 seconds of each side.(중략)

  • PDF

Determination of Residual Monomers in Dental Pit and Fissure Sealants

  • Mun, Hyeon Jung;Im, Beom Sun;Lee, Yong Geun;Kim, Cheol Wi
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.11
    • /
    • pp.1115-1118
    • /
    • 2000
  • Specimens were cured by using a 1 mm (thickness) ${\times}$5 mm (diameter) teflon mold, and were immersed in artificial saliva and in 75% ethanol for 1, 7, 14, 21 and 28 days in order to quantify and to identify toxic components and to determine any degra dation byproducts of Bis-GMA that might be released from five commercially available resin-based dental sealants. In artificial saliva, the only released component was triethylene glycol dimethacylate (TEGDMA). In 75% ethanol, TEGDMA, 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropoxy) phenyl]propane (Bis-GMA) and urethane dimethacrylate (UDMA) were released highly at the initial stage, indicating that the amount of component released is not linearly correlated with the immersion time. The amount of released TEGDMA was found to be much higher in 75% ethanol than in artificial saliva. Importantly, bisphenol-A (BPA) was detected from all the uncured sealants tested, suggesting that all the sealants tested contain BPA as a contaminant.

Separation of Light Rare-Earth Elements Using Gas-Pressurized Extraction Chromatography

  • Kim, Namuk;Park, Jai Il;Um, Wooyong;Kim, Jihye
    • Mass Spectrometry Letters
    • /
    • v.12 no.4
    • /
    • pp.186-191
    • /
    • 2021
  • A new method for chemical separation of light rare-earth elements (LREEs) using gas-pressurized extraction chromatography (GPEC) is described. GPEC is a microscale column chromatography system that features a constant flow of solvents, which is created by pressurized nitrogen gas. The separation column with a Teflon tubing was packed with LN resin. The proposed GPEC method facilitates production of lesser chemical wastes and faster separation owing to the use of low solvent volume compared to traditional column chromatography. We evaluated the separation of Ba, La, Ce, and Nd using various elution solvents. The column reproducibility of the proposed GPEC system ranged from 2.4% to 4.9% with RSDs of recoveries, and the column-to-column reproducibility ranged from 3.1% to 6.3% with RSDs of recoveries. The proposed technique is robust, and it can be useful for the fast separation of LREEs.

EFFECTS OF AGING AND THERMAL CYCLING ON THE BIAXIAL FLEXURE STRENGTH OF VENEERING RESIN COMPOSITES FOR CROWN (시효처리와 thermal cycling이 치관전장용 복합레진의 2축굽힘강도에 미치는 영향)

  • Jeong, Gwan-Ho;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.597-606
    • /
    • 1999
  • This study was performed to evaluate the effect of aging and thermal cycling on the biaxial flexure strength of low commercially available veneering resin composites for crown(Dentacolor : DC, Artglass : AG, Esternia : ET and Targis : TG). Disc specimens were fabricated in a teflon mold giving 12mm in diameter and 1mm in thickness. All samples were divided into 4 groups. Group 1 was dried in a dessicator at $25^{\circ}C$ for 30 days. Group 2 was immersed in distilled water at $37^{\circ}C$ for 30 days. Group 3 was immersed in distilled water at $65^{\circ}C$ for 30 days. Group 4 was subjected to 10,000 thermal cycles between $5^{\circ}C\;and\;55^{\circ}C$, and the immersion time in each bath was 15 seconds per cycle. Biaxial flexure test was conducted using the ball-on-three-ball method at the cross head speed of 0.5mm/min and fracture surfaces were observed with scanning electoron microscope. The results obtained were summarized as follows; 1. Weibull modulus values, except for the AG group, decreased after thermal cycling treatment. 2. Biaxial flexure strength values of aging group at $37^{\circ}C$ were the lowest in all sample groups. Except for the DC group, strength values were significantly decreased for the drying group. 3. After thermal cycling test, the highest value of biaxial flexure strength of 188.8 MPa was observed in the ET group and the lowest value of 73.2 MPa was observed in the DC group. The strength values showed the significant differences in each group (p<0.05). 4. Observation of surfaces after thermal cycling test revealed the ditching in the part of surrounding large fillers.

  • PDF

Flexural strength of composite resin fabricated by various polymerization method (다양한 중합 방법으로 제작한 간접 수복물용 복합레진의 굴곡 강도)

  • Kim, Dong-Yeon;Park, Jin-Young;Kang, Hoo-Won;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • Purpose: The aim of this study is to evaluate composite resins of indirect restorations for testing of flexural strength according to various polymerization methods. Methods: Specimen was produced a total of 40 to 10 per each group with a length 25 mm, width 2 mm, thickness 2 mm using a Teflon zig. The polymerization groups were classified into four groups. The first group proceeded with light curing only(LC group). The second group proceeded with light and heat curing(LHC group). The third group proceeded with air press and light curing(ALC group). The fourth group proceeded with air press, light and heat curing(ALHC group). Each prepared group was evaluated by flexural strength test. Statistical analysis was performed by one-way ANOVA. Post-test was performed with Tukey test. Results: The lowest in the ALC group was 119.18 MPa and the highest in the ALHC group was 168.15 MPa. There were statistically significant differences. Conclusion : The composite resin of the indirect restoration is recommended to heat curing along with the air press.

Ln-resin and HIBA Method for La-Ce and Sm-Nd Isotope Measurement (La-Ce 및 Sm-Nd 동위원소계 측정을 위한 란탄-레진법과 HIBA(Hydroxy Isobutyric Acid)분리법의 상호비교)

  • Lee, Seung-Gu;Lee, Hyomin;Asahara, Yoshihiro;Lee, Mi-Jeong;Choo, MiKyeong;Lee, SeungRyeol
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.431-439
    • /
    • 2012
  • A column chemistry is the most useful tools for isolating the elements of interest in isotope geochemistry. Here we introduce the chemical experimental procedure for Sm, Nd, La and Ce separation such as Teflon powder or Ln-resin method using HDEHP of KIGAM, KBSI, KOPRI and ${\alpha}$-HIBA(${\alpha}$-Hydroxy Isobutyric acid) method of Nagoya University, Japan. This technical report will provide an useful information in selecting the experiment method for rare earth element isotope system study such as Sm-Nd and La-Ce isotope system.

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

PROPERTIES OF FLUORIDE-RELEASING RESIN COMPOSITE RESTORATIVE MATERIALS (불소방출성 콤포짓트 레진계 수복재의 특성)

  • Kim, Sang-Hoon;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.418-426
    • /
    • 2008
  • The objectives of this study were to examine the properties of fluoride-releasing resin composite restorative materials. Four commercially available compomer materials (Compoglass F: CF, $Dyract^{(R)}$ AP: DA, $Dyract^{(R)}$ flow: DF, F2000: FT) and one fluoride-releasing composite resin ($Tetric^{(R)}$ Ceram: TC) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Disk-shaped specimens were fabricated in the split teflon mold with diameter of 15mm and thickness of 1mm. After curing for an hour, specimens were immersed in deionized water at $37^{\circ}C{\pm}1^{\circ}C$ for 30 days. All specimens were thermocycled for 10,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Toothbrush abrasion test was conducted under a load of 1.5 N and the abraded surfaces were examined with surface roughness tester (SV-3000, Mitutoyo Co, Japan) and SEM (JSM-5800, JEOL, Japan). Fluoride recharging was done by toothbrushing for 3 min. using a fluoride toothpaste (Perio Alpine Herb, LG Household & Health Care, Korea). The results obtained were summarized as follows; 1. The highest tensile strength value of 32.3 MPa was observed in TC group and the lowest value of 16.8 MPa was observed in CF group. The tensile strength of TC group was significantly higher than those of CF and DF groups (P<0.05). 2. The lowest Ra value of 0.287 was observed in TC group and the highest value of 1.516 was observed in FT group. The Ra value of FT group was significantly higher than other groups (P<0.05). 3. The abraded surfaces revealed the increase of surface roughness due to the protrusion and missing of filler particles. 4. The release of fluoride of compomers after tooth brushing by Perio Alpine Herb was initially large and then followed by small and continuously. But it remains small and constant in fluoride-releasing composite resin of TC. 5. The highest value of fluoride release after toothbrushing by Perio Alpine Herb was $2.064{\mu}g/cm^2$ in CF group and the lowest value was $0.1119{\mu}g/cm^2$ in TC group. The amount of fluoride release of CF group was significantly higher than other groups (P<0.05).

  • PDF