• Title/Summary/Keyword: Teeth abrasion

Search Result 57, Processing Time 0.026 seconds

COMPARISON OF THE PHYSICAL PROPERTIES OF FOUR KINDS OF ACRYLIC RESIN DENTURE TEETH (4종 아크릴릭 레진 인공치의 물리적 성질에 관한 비교)

  • Hwang, Jong-Woo;Chung, Chae-Heon;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.210-230
    • /
    • 1995
  • To compare the wear resistance of four kinds of commercial acrylic resin teeth [SR-Orthosit PosterioresR(Ivoclar Co., Liechtenstein), Endura PosteriorR(Shofu Inc. Japan), trubyte IPN teethR(Dentsply International Inc., York,), Trubyte BiotoneR(dentsply Inermational Inc. Brazil) by means of the toothbrush abrasion method, the artificial resin teeth were embedded in epoxy resin with the occlusal surfaces aligned in one plane for a total of 40 blocks. There after, each lock was mounted in the arm of the toothbrush abrasion machine(K 236, Japan). Wear measurements were made on the three preconditioned states. Those were as follows : no treatment specimens, thermocycled specimens, and thermocycled specimens which were immeresed applied load of 400g during the buring the brushing cycle. At the end of the 30,000-stroke cycle, each specimen was removed, and weighed. The microhardness of four kinds of commercial resin teeth were determined by means of microhardness tester. Microhardness tests were performed on te no treatment specimens, thermocycled specimens, and thermocycled specimens with immersion in the denture cleansing solution. Finally, the comparison of thermal properties were perfomed using differential scanning calorimeter(DSC-1500). The following results were obtained : 1. In the case of no treatment teeth, the wear amount of endura Posterior(EN) was the greatest among the others(p<0.01), and the wear amount of three kinds of artificial resin teeth was increased in the order of Trubyte IPN teeth(IN), Trubyte Biotone(BN), SR-Orthosit Posteriores(SN) but there was no statistic significance(p>0.01). 2. The wear amount of Trubyte IPN teeth(IT) and Trubyte Biotone(BT), was increased due to thermocycling effect, but that of Endura Posteriores(ET) was decreased conversely(p<0.01). 3. Except for the SR-Orthosit Posteriores(STC), the wear amount of three kinds of artificial resing teeth(that is, ETC, ITC, BTC) was increased due to denture cleansing solution$(Cledent^R)$, but there was no statistic significance(p>0.01). But the wear amount of the SR-Orthosit Posteriores(STC) was the greatest among the others(p<0.01). 4. The wear amount of toothbrush was the greatest in case of contact with occlusal surface of SROrthosit Posteriores resin teeth(p<0.01). 5. the microhardness values(KHN) of the SR-Orthosit Posteriores was the highest among the experimental artificial resin teeth(p<0.01). 6. There was no relationship between microhardness valuse(KHN) and wear amount of four kinds of experimental artificial resin teeth(p<0.01). 7. The differential canning calorimetric property of four kinds of artificial resin teeth did not show endothermal or exothermal peak in the range of $100^{\circ}C$

  • PDF

A study on the cervical abrasion in some industrial workers (일부 산업장 근로자의 치경부마모증에 관한 연구)

  • Lee, Myeong-Seon;Ku, In-Young;Ka, Kyung-Hwan;Moon, Seon-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.3
    • /
    • pp.387-393
    • /
    • 2013
  • Objectives : This study was carried out to investigate stepwise regression analysis on cervical abrasion & general characteristics, subjective oral health perception, habit related to oral health, and oral symptom. Methods : The study subjects were 2,158 workers in 23 industrial work places located in Gumi-si, Gyeongsangbuk-do Province from June 1 to July 1, 2012. As a result, the following conclusions were obtained. Results : 1. The cervical abrasion rate was high in men and older age group. 2. The cervical abrasion rate was high in a case of having not received scaling for the past one year. 3. The cervical abrasion rate was high in frequent tooth brushing. 4. The cervical abrasion rate was high in group having no bleeding in tooth and the gum. 5. The cervical abrasion rate was high in group having the cold symptom in teeth. 6. Excluding gum pain and bleeding, factors affecting tooth abrasion were gender, age, scaling over the past year, frequency of brushing a day and tooth sensitivity when cold food was ingested. 7. Gender and tooth sensitivity turned out to have negative(-) effect. age, scaling over the past year and frequency of brushing a day turned out to have positive(+) effect. Conclusions : Through this study, the best prevention method of cervical abrason is effective tooth brushing education and regular dental check up.

Wear Characteristics of Plastic Pinion Against Steel Gear (플라스틱기어의 마멸특성에 관한 고찰)

  • 김충현;김영민;안효석;정태형
    • Tribology and Lubricants
    • /
    • v.16 no.5
    • /
    • pp.324-331
    • /
    • 2000
  • Wear characteristics of Plastic and Nylon pinions against steel gear were studied to gain a better understanding of their tribological behaviors. Wear tests were conducted with power circulating gear test rig under dry contact conditions. Specific wear rates were measured as a function of applied load and the number of revolution. The worn teeth surfaces were examined with a profile projector and a camera. Nylon pinion showed lower specific wear rates than acetal pinion, but suffered teeth breakage under high load per unit tooth width. The dominant wear mechanisms found were adhesion and abrasion.

COMPARISON OF MICROLEAKAGE IN SEALANT REPAIRED WITH DIFFERENT SURFACE TREATMENT (파손된 치면열구전색제의 수리 방법에 따른 미세누출 비교)

  • Kang, Myung-Bong;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.204-214
    • /
    • 2007
  • The aim of this study was to investigate whether differences in surface treatment prior to repair influenced the seal of a resin fissure sealant placed on the occlusal surfaces of permanent molar teeth. One hundred and twenty extracted human molars were selected and a light curing sealant was placed on their occlusal surface following cleaning by prophylaxis and acid etching. The teeth were deliberately damaged, and then stored in artificial saliva for four weeks. Sixty teeth with the desired morphology of sealant failure were randomly divided into four groups where one group was treated with only etching agent, another by only air-abrasion, another by applying an etching agent followed by a bonding agent, and the last by air-abrasion followed by a bonding agent each. After sealant application, the samples were thermocycled and the degree of microleakage was determined. The results were as follows : 1. In the sealant/sealant interface group 2(0.22), 4(0.23) using air-abrasion showed a significantly lower microleakage score than group 1(0.38), 3(0.35) using an etching agent(p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 2 and groups 3, 4. 2. In the sealant/tooth interface, group 3(0.20), 4(0.20) which used a bonding agent showed a significantly lower microleakage score than group 1(0.35), 2(0.40) (p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 3 and groups 2, 4. 3. In SEM examination, while sealant surfaces treated with etching did not result in highly rough surfaces, those treated with air-abrasion did show rough surfaces.

  • PDF

COMPARISON OF WEAR RESISTANCE AMONG RESIN DENTURE TEETH OPPOSING VAR10US RESTORATIVE MATERIALS (수복재료에 대합되는 의치용 레진치의 마모저항성 비교)

  • Lee, Chul-Young;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.313-327
    • /
    • 1999
  • The aim of this study was to compare wear resistance of resin denture teeth opposing various restorative materials. The wear resistance of conventional acrylic resin teeth(Trubyte Biotone) and three high-strength resin teeth(Bioform IPN, Endura, SR-Orthosit-PE) opposing different restorative materials(gold alloys, dental porcelain, composite resin) was compared. Wear tests were conducted with a sliding-induced wear testing apparatus which applied 100,000 strokes to the specimen in a mesio-distal direction under conditions of 100 stroke/min and constant loading of 1Kgf/tooth. Wear resistance of the resin denture teeth was evaluated by the following criteria : 1) wear depth, 2) weight loss, and 3) SEM observation. Results were as follows. 1. When opposed to gold alloys and composite resin, high-strength resin teeth showed superior wear resistance compared to acrylic resin teeth. But, in cases opposing dental porcelain, differences between the wear of the high-strength and acrylic resin teeth were not statistically significant (p<0.05). 2. When comparing wear resistance among high-strength resin teeth, opposing gold alloys, Endura was slightly more resistant and while in cases opposing dental porcelain, SR-Orthosit-PE was showed to be slightly resistant(p<0.05). 3. The wear of high-strength resin teeth was greater by 5 to 7 times when opposing porcelain and 2 to 3 times when opposing composite resin compared to gold alloys(p<0.05). 4. SEM observations of the wear surface showed that wear of resin teeth opposing gold alloys is a fatigue type of wear and wear of resin teeth opposing dental porcelain is fatigue and abrasion type of wear. Trubyte Biotone showed more severe fatigue type of wear than high-strength resin teeth. In conclusion, the use of dental porcelain should seriously be considered as restorative material in cases opposing resin denture teeth and improvement seems to be needed on resin teeth in the areas of wear resistance.

  • PDF

A Study on the Toothbrush-Dentifrice Abrasion of Class V Restroations (치경부 5급 와동 수복의 잇솔질 마모에 관한 연구)

  • Hwang, Su-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.69-81
    • /
    • 2005
  • The objective of this study was to evaluate the toothbrush abrasion characteristics of class V restorations. Thirty extracted human premolars, which were collected from oral surgery clinics were used. We mounted five teeth in a metal ring mold of 50 mm in diameter and 15 mm in height using chemically cured acrylic resin. Class V cavities were prepared in lingual cervical root surfaces and restored using one of following restorative materials : Dentin Conditioner/Fuji II LC (Group FL), All Bond II/Z-250 (Group ZT), One-up Bond F/Palfigue Estelite (Group PE), F2000 Primer/Adhesive (Group FT), and Prime & Bond 2.1/Dyract AP (Group DR). They were stored under distilled water at $37^{\circ}C$ for seven days. The toothbrush abrasion test was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles. We have examined the bonded interfaces, the changes of surface roughness and color of abraded surfaces. From this experiment, the following results were obtained. 1. The change of surface roughness showed high degree: RMGIC>compomer>composite resin (p<0.05). 2. Because of the protrusion and missing of filler particles, SEM observation of abraded surfaces of RMGIC and compomers revealed the increase of surface roughness due to the selective removal of matrix resin. 3. The color change by toothbrush abrasion was affected in large part by the change of $L^*$ and $b^*$ of resin composites (p<0.05). 4. The color change by toothbrush abrasion was so small to detect by human eyes. 5. SEM observation of abraded surfaces revealed the interface bonding was the best in the FT group.

A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES (제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가)

  • Kim, Hyung-Su;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

Full mouth rehabilitation with vertical dimension elevation in the patient with severely worn dentition: case report (과도한 치아 마모 환자에서 수직고경 증가를 동반한 전악 수복 증례)

  • Lee, Eun-Jee;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • Excessive teeth abrasion causes pathologic changes of oral environment and masticatory system due to decrease in occlusal vertical dimension. When establishing new occlusal plane and recovering vertical dimension, accurate diagnosis and analysis are essential. In this case, after appropriate centric relation in elevated vertical dimension was taken using Gothic arch tracer, full mouth rehabilitation was performed. A 70-year-old male patient had the chief complaint that he could not eat due to teeth wear. He showed generalized teeth wear and decreased vertical dimension. Elevation of vertical dimension was planned by model analysis. According to increased vertical dimension, centric relation was recorded using Gothic arch tracer and temporary prostheses were applied. Appropriate occlusion was established by temporary prostheses for 4 months. Final prostheses were fabricated using vertical dimension adapted by temporary prostheses. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

THE EFFECTS OF SURFACE TREATMENT AND THERMOCYCLING ON THE MICROLEAKAGE OF COMPOSITE RESIN CORES (치아표면 처리방법과 thernocycling이 콤포짓트 레진 코어의 미세누출에 미치는 영향)

  • Lim, Yong-Chul;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.255-263
    • /
    • 2000
  • The purpose of this study was to compare the microleakage of the composite resin cores according to surface treatment, dentin bonding agents, and thermocycling. For this study, 120 extracted premolar teeth were used. Flat occlusal surfaces were prepared with diamond disk, and treated with air-abrasion, acid-etching, combination. The composite resin core was built with Z-100 after application of Scotchbond Multi-Purpose and All-Bond 2. Prepared specimens were thermocycled for 2,000 cycles. Specimens were immersed in 1% methylene blue solution for 24hours at $37^{\circ}C$. The microleakage was measured with a inverted metallurgical microscope(BHS313, Olympus, Japan). The following conclusions were drawn from this study: 1. The microleakages in the groups treated with air-abrasion and with acid etching were greater than that of the groups treated with combination method before thermocycling(p<0.05), the microleakages of the groups treated with air-abrasion were greater than that of the groups treated with acid-etching and combination method after thermocycling(p<0.05) 2. There were no significant difference between groups using Scotchbond Multi-Purpose and the groups using All-Bond 2. 3. Thermocycling didn't affect the change of microleakage in all cases.

  • PDF

THE EFFECTIVENESS OF POTASSIUM OXALATE AND SODIUM FLUOIRIDE ON THE REDUCTION OF DENTINAL HYPERSENSITIVITY (Potassium oxalate와 Sodium fluoride의 상아질 지각과민 억제효과)

  • Seo, Min-Soo;Park, Dong-Soo;Jeong, Chang-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.216-225
    • /
    • 1991
  • The purpose of this study was to evaluate the desensitizing effect of potassium oxalate(Group I), sodium fluoride (Group II), and control group (Group III). The 120 teeth of 26 patients who had been complained dentinal hypersensitivity were divided into three groups by applicating agent. The observation was done before and immediately after treatment. The data were statistically analyzed and the results were as followed. 1. Potassium oxalate showed the best desensitizing effect to the stimuli, followed by sodium fluoride, control group, and there was a significant difference (p<0.05) in desensitizing effect among the groups. 2. Potassium oxalate showed the best desensitizing effect to the stimuli, followed by sodium fluride, control group on both cervical abrasion and gingival recession, and there was a significant difference (p<0.05) in desensitizing effect among the groups on both cervical abrasion and gingival recession. 3. There was no significant difference (p<0.05) in effect of the desensitization between cervical abrasion and gingival recession. 4. The scratch and air blast I were more effective in desensitiziation than other stimuli with significant difference (p<0.05). In view of the results mentioned above, it can be conceived that potassium oxalate is more effective than sodium fluoride on the reduction of dentinal hypersensitivity.

  • PDF