Can Auto-ID make Trade Stable between Korea and China?

  • Choi, Jae-Seob
    • The Journal of Information Technology
    • /
    • v.7 no.4
    • /
    • pp.119-127
    • /
    • 2004
  • As increasing trade through the world, especially in food, asymmetry of information can make the trade shrink. With the industrial development, Korea's agriculture had shrunk dramatically. By the result of the nation's industrial restructuring, over than 3/4 of Korea food consumption comes from abroad. And China is an important source of agricultural product to Korea. Increasing family income and increasing importing food consumption, Korean consumers have been interested in food safety. Especially. after experiencing several cases like struggle for safety of GMO food, poultry influenza, lead contained Chinese fish import, mad cow disease, cheating origin, etc. Obviously, those unreliable cases will hinder the increase of world free trade as well as the trust of two countries. Furthermore, distrust will be a cause of adverse selection. So, it need to find a way to solve the distrust which caused by asymmetry of information. And automatic identification procedures can help mitigate asymmetry of information in trade. And it will make Korean consumers can avoid adverse selection. This paper suggests adoption of Auto ID to encourage agricultural trade between Korea and China.

  • PDF

Directional Asymmetry of Gonadal Development in Ayu (Plecoglossus altivelis)

  • Park In-Seok;Zhang Chang Ik;Kim Young Ja;Bang In Chul
    • Fisheries and Aquatic Sciences
    • /
    • v.8 no.4
    • /
    • pp.207-212
    • /
    • 2005
  • Directional (sinistral) asymmetry (DA) occurs when the traits of one side of a supposedly bilaterally symmetrical organism differ in a random way from those of the other side. We examined asymmetries in gonadal growth traits within both sexes of hatchery reared ayu, Plecoglossus altivelis. The pattern of the gonadal growth from hatching to 320 days after hatching was a type of DA except for the growth in gonad weight from 140 to 180 days after hatching, although the ovary of the right side tended to exhibit more pronounced DA phenomenon.

Tests for Asymmetry and Structure Changes in Retail Price Volatility of Fresh Common Squid in the Republic of Korea (신선 물오징어 소매가격 변동성의 구조변화와 비대칭성 검증)

  • Nam, Jongoh;Sim, Seonghyun
    • Ocean and Polar Research
    • /
    • v.37 no.4
    • /
    • pp.357-368
    • /
    • 2015
  • This study analyzed structural changes and asymmetry of price volatility during the period before and after a point of structural change in price volatility, using the Korean fresh common squid daily retail price data from January 1, 2004 to September 30, 2015. This study utilized the following analytical methods: the unit-root test was applied to ensure the stability of the data, the Quandt-Andrews breakpoint test was applied to find the point of structural change, and the Glosten-Jagannathan-Runkle GARCH and EGARCH models were applied to investigate the asymmetry of price volatility. The empirical results of this study are as follows. First, ADF, PP, KPSS and Zivot-Andrews tests showed that the daily retail price change rate of the Korean fresh common squid differentiated by logarithm was stable. Secondly, the ARIMA (2,1,2) model was selected by information criteria such as AIC, SC, and HQ. Thirdly, the Quandt-Andrews breakpoint test found that a single structural change in price volatility occurred on June 11, 2009. Fourthly, the Glosten-Jagannathan-Runkle GARCH and EGARCH models showed that estimates of coefficients within the models were statistically significant before and after structural change and also that asymmetry as a leverage effect existed before and after structural change.

The Relation Between the Fugl-Meyer Motor Assessment and Walking and Balance Ability in Stroke Patient (뇌졸중 환자에서 기능평가와 보행 및 균형과의 관련성)

  • Bae, Won-Sik;Lee, Geon-Choel;Nam, Hyoung-Chun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.1
    • /
    • pp.59-69
    • /
    • 2011
  • Purpose : The purposes of this study were to find correlations among Fugl-Meyer Assessment Scale, walking velocity, walking asymmetry and balance ability. Methods : The study sample consisted of 50 stroke patients referred to the Department of Rehabilitation Medicine in the Sanggye Paik, Ilsan Paik, Seoul Paik, and Dobong Hospital. All subjects were ambulatory with or without an assistive device. All participants were assessed on Fugl-Meyer Assessment scale and walking velocity, walking asymmetry. The data were analyzed using independent t-test, ANOVA, and multiple regression. Results : The results revealed that upper extremity coordination, balance and pain items of Fugl-Meyer Assessment scale were significantly correlated with walking velocity and upper extremity and upper extremity motor and balance items of Fugl-Meyer Assessment scale were significantly correlated with walking asymmetry. Fugl-Meyer Assessment scale was not significantly correlated with Static Balance Index, Dynamic Balance Index and Weight Distribution Asymmetry Index. Their power of explanation regarding comfortable walking velocity and comfortable walking asymmetry were 60.3%, 42.5% respectively. Conclusion : These results showed that Fugl-Meyer Assessment scale is significantly correlated with walking velocity, asymmetry and not significantly correlated with balance ability. Therefore Fugl-Meyer Assessment scale is an appropriate assessment tool to predict walking ability of patients with stroke. Futher study about walking velocity and asymmetry by change of Fugl-Meyer Assessment scale is needed using a longitudinal study design.

Reproduction of Walking Asymmetry in Knee Osteoarthritis with Split-Belt Conditions (분할 벨트 조건을 이용한 무릎 관절 이상군의 보행 비대칭성 모사)

  • Lee, Myunghyun;Park, Heewon;Park, Sukyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.885-890
    • /
    • 2015
  • Walking on split-belt treadmill has been applied to study walking disabilities, such as osteoarthritis (OA), to show asymmetric walking characteristics. In this study, we compared asymmetric walking in OA patients with healthy subjects under split-belt conditions and examined the reproduction of walking asymmetry in OA. Seven OA patients were instructed to walk at four frequencies, while four healthy subjects walked on a treadmill with tied-belt and split-belt conditions. To compare walking asymmetries, kinetic and kinematic measurements were made using force-plates and motion capture cameras, and subsequently center of mass (CoM) velocity, mechanical work and potential energy were calculated. Horizontal velocity change during split-belt walking of healthy subjects was similar to OA patients. Difference of mechanical work during single support phase occurred due to fall of CoM in fast belt. OA walking asymmetry could be reproduced by reducing differences of belt speeds to prevent rapid fall of CoM.

Improvement of Nottingham Grading System for Facial Asymmetry Evaluation (안면비대칭 평가를 위한 Nottingham Grading System의 문제점 개선)

  • Lee, Min-Woo;Jang, Min;Kim, Jina;Shin, Sang-Hoon
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Because facial asymmetry is caused by various causes, the cause analysis is important and quantitative index is needed to the evaluation. In this study, we applied the Nottingham Grading System that was used as a quantitative index to evaluate the facial paralysis by tracking the markers through the image processing and calculating the distance between the markers with images obtained by using the webcam, to evaluate facial asymmetry. The existing Nottingham Grading System has a problem of causing a measurement error in the specific case because the left and right are compared by summing the distance change between the feature points of the face part according to the change of the facial expression. We compared the case of the facial asymmetry and case of normal subject by using the existing Nottingham Grading System and the improved Nottingham grading system. In the existing Nottingham Grading System, case of facial asymmetry and case of facial symmetry were 99.0% and 95.0% respectively in the normal range, but the improved Nottingham Grading System showed facial asymmetry case was 74.0% and facial symmetrical case was 93.2%. The results of experiment show that the improved Nottingham Grading System allows detailed evaluation of each site and improved the problem of the Nottingham Grading System for specific cases.

Prediction of Asymmetric Turbulent Fluid Flow and Heat Transfer in the Parallel Plates (평행평판내 비대칭 난류유동과 열전달의 예측)

  • 오세경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.303-310
    • /
    • 1998
  • We report on the analytical results of examination of fully developed asymmetric flow and heat transfer between parallel plane plates. The asymmetry was introduced by roughening one of the plane while the other was left smooth. The integral method together with a turbulence model based on modified Prandtl's mixing length theory for the rough was used to determine the velocity distribution and friction. The temperature distrtibution is then predicted and heat transfer coefficients are calculated. The present paper shows that the heat transfer increases more than the friction factor for a given roughness structure. Generally the results show the strong effect of asymmetry on engineering parameters. Furthermore it is the roughness structure which influences the nature of asymmetry and heat transfer.

  • PDF

The Method of medical Infrared Thermographic imaging using an Infrared LED Lamps (적외선 LED 램프를 이용한 적외선 체열 영상 진단)

  • Song, M.J.;Ryu, S.M.;Soo, B.M.;Kim, J.S.;Choi, W.S.;Park, C.B.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.282-282
    • /
    • 2010
  • LED Device was designed of electronic circuits of electrical power part for used Pspice student version and used Infrared LED lamps of load part. LED was used Computerized Electronic Medical Infrared Thermographic Imaging System for body surface Investigation of variable Body thermal asymmetry. It was knowledge body thermal Asymmetry of body surface and quantity body surface of electromagnetic wave to inflow electrical power part.

  • PDF

A Study on the Information Asymmetry among Cryptocurrency Traders (암호화폐 거래자 사이에 형성되는 정보 비대칭 현상에 관한 연구)

  • Park, Minjung;Cha, Sangmi
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.3
    • /
    • pp.29-41
    • /
    • 2019
  • As users' interests of cryptocurrency has been increased, investment volume of it also increases. In the cryptocurrency market, it cannot always be distributed homogenous information to all investors, similar to the stock market because it reflects the characteristics of a market microstructure. Cryptocurrency traders, thus, like stock investors, can experience the information asymmetry in the market and cannot but help to depend on private information. The purpose of this study is to estimate the trading intensity of informed traders and uninformed traders among cryptocurrency investors around the world based on PIN (Probability of Informed Trading). We have an aim to compare the difference of information asymmetry according to the ten types of cryptocurrency. The results of this study are expected to prevent the continuous increase of suspicious transactions related to cryptocurrency and contribute to the development of a sound cryptocurrency market.

Study of Rotor Asymmetry Effects of an Induction Machine by Finite Element Method

  • Abdesselam, Lebaroud;Guy, Clerc
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.342-349
    • /
    • 2011
  • This paper presents a study on rotor asymmetry caused by broken bars and its effects on the stator current of an induction machine under an unbalanced supply voltage. The simulation of the induction machine is based on the finite element method. In the early stage of diagnosis, we show new sidebands specific to the partial rupture of the rotor bar. Experimental tests corroborate with the simulation results.