• 제목/요약/키워드: Technical complications

검색결과 219건 처리시간 0.027초

Safety of endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction and ascites

  • Tsukasa Yasuda;Kazuo Hara;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Yasuhiro Kuraishi;Takafumi Yanaidani;Sho Ishikawa;Masanori Yamada;Toshitaka Fukui
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.246-252
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) is useful for patients with biliary cannulation failure or inaccessible papillae. However, it can lead to serious complications such as bile peritonitis in patients with ascites; therefore, development of a safe method to perform EUS-HGS is important. Herein, we evaluated the safety of EUS-HGS with continuous ascitic fluid drainage in patients with ascites. Methods: Patients with moderate or severe ascites who underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after the procedure at our institution between April 2015 and December 2022, were included in the study. We evaluated the technical and clinical success rates, EUS-HGS-related complications, and feasibility of re-intervention. Results: Ten patients underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after completion of the procedure. Median duration of ascites drainage before and after EUS-HGS was 2 and 4 days, respectively. Technical success with EUS-HGS was achieved in all 10 patients (100%). Clinical success with EUS-HGS was achieved in 9 of the 10 patients (90%). No endoscopic complications such as bile peritonitis were observed. Conclusions: In patients with ascites, continuous ascites drainage, which is initiated before EUS-HGS and terminated after completion of the procedure, may prevent complications and allow safe performance of EUS-HGS.

Esophagojejunal Anastomosis after Laparoscopic Total Gastrectomy for Gastric Cancer: Circular versus Linear Stapling

  • Park, Ki Bum;Kim, Eun Young;Song, Kyo Young
    • Journal of Gastric Cancer
    • /
    • 제19권3호
    • /
    • pp.344-354
    • /
    • 2019
  • Purpose: No standard technique has been established for esophagojejunal anastomosis during laparoscopic total gastrectomy (LTG) for gastric cancer owing to the technical difficulty and high complication rate of this procedure. This study was performed to compare the short-term outcomes of circular and linear stapling methods after LTG. Materials and Methods: A total of 106 patients treated between July 2010 and July 2018 were divided into 2 groups according to the following anastomosis procedures: hemi-double-stapling technique (HDST; circular stapling method; group C, n=77) or overlap method (linear stapling method; group L, n= 29). The clinicopathological features and postoperative outcomes, including complications, were analyzed. Multivariate analysis was performed using a logistic regression model to identify the independent risk factors for anastomotic complications. Results: The incidence of anastomotic complications was significantly higher in group C than in group L (28.0% vs. 6.9%, P=0.031). The incidence of anastomosis leakage did not differ between the groups (6.5% vs. 6.9%, P=1.000). However, anastomosis stricture occurred only in group C (13% vs. 0%, P=0.018). Multivariate analysis showed that the anastomosis type was significantly related to the risk of anastomotic complications (P=0.045). Conclusions: The overlap method was superior to the HDST with respect to anastomotic complications, especially anastomosis stricture.

Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Kang, Hyo Jae;Hwangbo, Bin
    • Tuberculosis and Respiratory Diseases
    • /
    • 제75권4호
    • /
    • pp.135-139
    • /
    • 2013
  • Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is becoming a standard method for invasive mediastinal staging and for the diagnosis of paratracheal and peribronchial lesions. It is essential to understand the technical aspects of EBUS-TBNA to ensure safe and efficient procedures. In this review, we discuss the practical aspects to be considered during EBUS-TBNA, including anesthesia, manipulation of equipment, understanding mediastinal ultrasound images, target selection, number of aspirations needed per target, sample handling, and complications.

The Avoidance of Microsurgical Complications in the Extradural Anterior Clinoidectomy to Paraclinoid Aneurysms

  • Son, Hee-Eon;Park, Moon-Sun;Kim, Seong-Min;Jung, Sung-Sam;Park, Ki-Seok;Chung, Seung-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권3호
    • /
    • pp.199-206
    • /
    • 2010
  • Objective : Paraclinoid segment internal carotid artery (ICA) aneurysms have historically been a technical challenge for neurovascular surgeons. The development of microsurgical approach, advances in surgical techniques, and endovascular procedures have improved the outcome for paraclinoid aneurysms. However, many authors have reported high complication rates from microsurgical treatments. Therefore, the present study reviews the microsurgical complications of the extradural anterior clinoidectomy for treating paraclinoid aneurysms and investigates the prevention and management of observed complications. Methods : Between January 2004 and April 2008, 22 patients with 24 paraclinoid aneurysms underwent microsurgical direct clipping by a cerebrovascular team at a regional neurosurgical center. Microsurgery was performed via an ipsilateral pterional approach with extradural anterior clinoidectomy. We retrospectively reviewed patients' medical charts, office records, radiographic studies, and operative records. Results : In our series, the clinical outcomes after an ipsilateral pterional approach with extradural anterior clinoidectomy for paraclinoid aneurysms were excellent or good (Glasgows Outcome Scale : GOS 5 or 4) in 87.5% of cases. The microsurgical complications related directly to the extradural anterior clinoidectomy included transient cranial nerve palsy (6), cerebrospinal fluid leak (1), worsened change in vision (1), unplanned ICA occlusion (1), and epidural hematoma (1). Only one of the complications resulted in permanent morbidity (4.2%), and none resulted in death. Conclusion : Although surgical complications are still reported to occur more frequently for the treatment of paraclinoid aneurysms, the permanent morbidity and mortality resulting from a extradural anterior clinoidectomy in our series were lower than previously reported. Precise anatomical knowledge combined with several microsurgical tactics can help to achieve good outcomes with minimal complications.

Accessory Hepatic Lobe: A Rare Cause of Prehepatic Portal Hypertension in a Child

  • Sag, Elif;Cansu, Aysegul;Imamoglu, Mustafa;Cakir, Murat
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제21권4호
    • /
    • pp.361-364
    • /
    • 2018
  • Accessory hepatic lobe is noted as and considered a rare disease in children. It can manifest with various symptoms and complications depending on the location, volume, type and position of the disease as presented on a child. The patient presented as a 14-month-old girl who was seen with a notable hepatosplenomegaly and portal hypertension. A diagnosis was made after taking an extensive medical history, observation and radiological examinations. The formal diagnosis was a prehepatic portal hypertension associated with accessory hepatic lobe.

Analysis of 120 Pectoralis Major Flaps for Head and Neck Reconstruction

  • You, Young Sun;Chung, Chul Hoon;Chang, Yong Joon;Kim, Kuyl Hee;Jung, Sung Won;Rho, Young Soo
    • Archives of Plastic Surgery
    • /
    • 제39권5호
    • /
    • pp.522-527
    • /
    • 2012
  • Background A pectoralis major flap is one of the standard tools for the reconstruction of defects of the head and neck. Despite the technical advancement in free tissue transfer in head and neck reconstruction, the benefits of a pectoralis major flap should not be overlooked. The purpose of this study is to evaluate our 17 years of experience in reconstructing defects of the head and neck region using the pectoralis major flap. Methods We retrospectively reviewed the medical records of 112 patients (120 cases) who underwent pectoralis major flap operations for head and neck reconstruction during a period ranging from 1994 to 2010. Results In our series, no total necrosis of the flap occurred. Of the total cases, 30.8% presented with flap-related complications. Major complications occurred in 20% of all of the cases but were then all successfully treated. The male sex was correlated with the occurrence of overall complications (P=0.020) and major complications (P=0.007). Preoperative albumin levels of <3.8 g/dL were correlated with the formation of fistula (P=0.030). Defects of the hypopharynx were correlated with the occurrence of major complications (P=0.019) and the formation of fistula (P=0.012). Secondary reconstructions were correlated with the occurrence of overall complications (P=0.013) and the formation of fistula (P=0.030). Conclusions A pectoralis major flap is still considered to be a safe, versatile one-stage reconstruction procedure in the management of the defects of head and neck and the protection of the carotid artery.

Outcomes of Stent-Assisted Coiling Using the Neuroform Atlas Stent in Unruptured Wide-Necked Intracranial Aneurysms

  • Kwon, Ohyuk;Chung, Joonho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.23-29
    • /
    • 2021
  • Objective : Although stent-assisted coiling (SAC) has been reported to be safe and effective in treating wide-necked aneurysms, the technique has procedure-related complications. Thus, we reported our experiences of SAC using the Neuroform Atlas stent in treating wide-necked aneurysms and evaluated the incidence of and risk factors for procedure-related complications. Methods : From March 2018 to August 2019, we treated 130 unruptured wide-necked aneurysms in 123 patients with Neuroform Atlas stents. Angiographic results and clinical outcomes were reviewed retrospectively. Clinical and angiographic follow-up were performed in all cases (mean, 12.4 months) after the procedure. Results : There were eight cases (6.2%) of procedure-related complications (two dissections, five thromboembolisms, and one hemorrhage) and two (1.5%) of delayed complications (one ischemia and one hemorrhage). There was one case (0.8%) of failure of stent deployment and one (0.8%) of suboptimal positioning of the stent. Follow-up angiography showed complete obliteration in 103 (79.2%), residual neck in 16 (12.3%), and residual aneurysm in 11 cases (8.5%). Aneurysm locations in the middle cerebral artery (odds ratio [OR], 2.211; p=0.046) and the anterior communicating artery (OR, 2.850; p=0.039) were associated with procedure-related complications on univariate analysis. However, no independent risk factor for procedure-related complications was noted in multivariate analysis. Conclusion : The Neuroform Atlas showed a high rate of technical success. Good clinical and radiographic outcomes in early follow-up suggests that the device is feasible and safe. SAC of aneurysms on the middle cerebral artery or anterior communicating artery may require more attention to prevent possible procedure-related complications.

3D CACT-assisted Radiofrequency Ablation Following Transarterial Chemoembolization for Hepatocellular Carcinoma: Early Experience

  • Jiao, De-Chao;Han, Xin-Wei;Wu, Gang;Ren, Jian-Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7897-7903
    • /
    • 2015
  • Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas. Materials and Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated. The puncture performance level was evaluated on a five-point scale (5-1: excellent-poor). Complete ablation rate was evaluated after two months follow-up using enhanced CT scans. Results: The technical success rate of RFA procedure under CACT navigation system was 100 %. Mean total procedure time was $24.24{\pm}6.53min$, resulting in a mean effective exposure dose of $15.4{\pm}5.1mSv$. The mean puncture performance level rated for CACT guided RFA procedure was $4.87{\pm}0.35$. Complete ablation (CA) was achieved in 20 (95.2%) of the treated 21 tumors after the first RFA session. None of patients developed intra-procedural complications. Conclusions: 3D CACT guidance system enables reliable and efficient needle positioning by providing real-time intraoperative guidance for performing RFA on HCCs.

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

  • Li, Xue-dong;Qin, Jun;Xiao, Zhen-yong;Feng, Yi;Chen, Jia-kang
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.341-345
    • /
    • 2016
  • Objective : Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. Methods : Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center in China. Technical and clinical complications were recorded. Modified Rankin Scale was used to evaluate the patients' conditions via clinic and telephone follow-up. Results : The mean width of aneurysm sac was $2.30{\pm}0.42mm$, and the mean diameter of aneurysm neck was $2.83{\pm}.48mm$. Complete occlusion was achieved in 28 aneurysms (90.32%); neck remnant was seen in 3 aneurysms (9.68%). Technical and clinical complications related to the procedure were encountered in four patients (12.5%). Two patients died (6.25%). No patient had a permanent deficit. Conclusion : Solitaire AB stent was a safe and efficiency tool in assisting coiling of micro aneurysms with wide neck, but may be not suitable for a blaster-like one. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

Incidents and Complications of Permanent Venous Central Access Systems: A Series of 1,460 Cases

  • El Hammoumi, Massine;El Ouazni, Mohammed;Arsalane, Adil;El Oueriachi, Faycal;Mansouri, Hamid;Kabiri, El Hassane
    • Journal of Chest Surgery
    • /
    • 제47권2호
    • /
    • pp.117-123
    • /
    • 2014
  • Background: Implanted venous access devices or permanent central venous access systems (PCVASs) are routinely used in oncologic patients. Complications can occur during the implantation or use of such devices. We describe such complications of the PCVAS and their management. Methods: Our retrospective study included 1,460 cases in which PCVAS was implanted in the 11 years between January 2002 and January 2013, including 810 women and 650 men with an average age of 45.2 years. We used polyurethane or silicone catheters. The site of insertion and the surgical or percutaneous procedure were selected on the basis of clinical data and disease information. The subclavian and cephalic veins were our most common sites of insertion. Results: About 1,100 cases (75%) underwent surgery by training surgeons and 360 patients by expert surgeons. Perioperative incidents occurred in 33% and 12% of these patients, respectively. Incidents (28%) included technical difficulties (n=64), a subcutaneous hematoma (n=37), pneumothoraces (n=15), and an intrapleural catheter (n=1). Complications in the short and medium term were present in 14.2% of the cases. Distortion and rupture of the catheter (n=5) were noted in the costoclavicular area (pinch-off syndrome). There were 5 cases of catheter migration into the jugular vein (n=1), superior vena cava (n=1), and heart cavities (n=3). No patient died of PCVAS insertion or complication. Conclusion: PCVAS complications should be diagnosed early and treated with probable removal of this material for preventing any life-threatening outcome associated with complicated PVCAS.