• Title/Summary/Keyword: Tc-99m Sestamibi Scan

Search Result 8, Processing Time 0.028 seconds

The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism (원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성)

  • Baik, S.H.;Kim, S.M.;Choi, K.M.;Choi, Y.S.;Kim, S.J.;Yu, J.M.;Choi, D.S.;Choe, J.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.465-472
    • /
    • 1995
  • An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  • PDF

Comparison Study of Lesion Localization in Patients with Primary and Secondary Hyperparathyroidism using Double-Phase Tc-99m Sestamibi Scintigraphy (일차성 및 이차성 부갑상선기능항진증 환자에서 Double-Phase Tc-99m Sestamibi 스캔에 의한 병변의 국소화에 관한 비교)

  • Jeon, Tae-Joo;Lee, Jong-Doo;Rhyu, Young-Hoon;Park, Jung-Soo;Jang, Hang-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.368-380
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate and compare the scintigraphic findings and diagnostic accuracy of double-phase Tc-99m sestamibi scan in primary and secondary hyperparathyroidism (HPT). Materials and Methods: We retrospectively reviewed 16 cases of primary (18 lesions) and 11 cases of secondary HPT (44 lesions) who underwent Tc-99m-sestamibi scan before the surgical intervention. Scan was performed using LEM camera (Siemens, Germany) after the injection of 740MBq of Tc-99m sestamibi. Routine image consisted of baseline and 3-hour delayed images and each image was obtained using both parallel and pine hole collimator. The study population was 27 patients (male/female=5/22, age: $49.1{\pm}10.8$). Results: Eighteen lesions of primary HPT consisted of 13 adenomas and S hyperplasias, while all lesions of secondary HPT were hyperplasias. Among the case of primary HPT, we could detect all the lesions of 13 adenomas but only 2 lesions of 5 hyperplasias (40%) could be detected by double phase scintigraphy. Three cases of primary lesion showed decreased uptake in delayed images compared with baseline. The sensitivity, specificity, positive predictive value and accuracy of primary and secondary HPT were 58.8% (10/17), 83.3% (10/12), 83.3% (10/12), 75.9% (22/29), and 37.5% (15/40), 50% (2/4), 88.2% (15/17), 38.6% (17/44), respectively. Overall sensitivity, specificity, positive predictive value and accuracy were 43.9% (25/57), 75% (12/16), 86.2% (25/29), and 53.4% (39/73). There were no statistical difference between the weight of primary and secondary HPT lesion (p>0.05). Conclusion: Tc-99m sestamibi scan is fairly good modality to detect parathyroid lesion in patient with primary HPT before the surgical intervention. However, since some of cases may reveal decreased uptake in delayed image, a careful attention to the findings of baseline images may be helpful. Still the low accuracy of sestamibi scan in diagnosis of secondary HPT prohibits routine use of it for this disease.

  • PDF

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

The Role of Rest Image in Patients Showing Normal Stress Image on Tc-99m Myocardial Perfusion Scan (심근 관류스캔 중 정상 부하영상 소견을 보인 환자에서 휴식기 영상의 필요성에 대한 평가)

  • Bom, Hee-Seung;Song, Ho-Chun;Min, Jung-Jun;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.502-506
    • /
    • 1996
  • Tc-99m myocardial perfusion agents such as Tc-99m sestamibi or Tc-99m tetrofosmin has advantages over T1-201 for myocardial perfusion scan fuck as low attenuation and easy availability. However, Tc-99m agents do not redistribute so they need to be given T times, namely after stress and at rest. To evaluate whether rest image is needed in patients showing normal stress image, 43 patients who underwent both myocardial perfusion scan and coronary angiography and showed normal stress images were evaluated. Findings of rest images of them were evaluated whether they change the diagnosis or treatment plans. Among 43 patients who showed normal stress myocardial perfusion imaging, 31 (72.1%) showed no additional informations. However, among 5 patients with vasospastic angina 4 (80%) showed abnormal rest images in spite of normal stress images. So, when vasospastic angina is suspected clinically, rest image could be helpful in identifying patients with coronary vasospasm. In conclusion, rest myocardial perfusion images were not helpful in 72.1 % of patients with angina when stress images were normal. In only exception was those with vasospastic angina.

  • PDF

Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect (일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교)

  • Jeong, Shin-Young;Lee, Jae-Tae;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.83-93
    • /
    • 2003
  • Background: Lung-to-heart uptake ratio (LHR) in $^{201}Tl-chloride$ myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for $^{99m}Tc-MIBI$ imaging. Furthermore, most of results suggesting lung uptake of $^{99m}Tc-MIBI$ as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated $^{99m}Tc-MIBI$ imaging can reflect the degree of perfusion defect or left ventricular performance. Subjects and Methods: 241 patients underwent exercise $^{99m}Tc-MIBI$ myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two legions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: >50%, Gr-II: 36-50%, Gr-III: <36% and by summed stress score (SSS), as Gr-A: <4, Gr-B: 4-8, Gr-C: 9-13, Gr-D: >13, LHR was compared among these groups. Results: In NP group(n=135), LHR, were higher in men than women ($men:\;0.311{\pm}0.03,\;women:\;0.296{\pm}0.03,\;p<0.05$). Significant difference, in LHR were found between NP and AP groups both for men and women ($men:\;0.311{\pm}0.03\;vs\;.\;0.331{\pm}0.06,\;women:\;0.296{\pm}0.03\;vs.\;0.321{\pm}0.07.\;p<0.05$). There were weak negative correlation between LHR and LVEF (r=-0.342, p<0.05) and weak positive correlation between LHR and SSS (r=0.478, p<0.05) in men, but not in women (LVEF: r=-0.279, p=0.100, SSS: r=0.276, p=0.103). Increased LHR was defined when for more than mean + 2SD value ($men{\geq}0.38,\;women{\geq}0.37$) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 35.4%, p<0.05) and higher SSS(Gr-A: 14.0%, Gr-B: 5.7%, Gr-C: 18.2%, Gr-D: 40.7%, p<0.05). Conclusions: LHRs obtained from routine $^{99m}Tc-MIBI$ gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.

Primary Hyperparathyroidism due to Parathyroid Adenoma (부갑상선 선종에 의한 원발성 부갑상선 기능 항진증)

  • Park, Woo-Hyun;Bae, Byung-Jin;Choi, Soon-Ok
    • Advances in pediatric surgery
    • /
    • v.6 no.1
    • /
    • pp.68-69
    • /
    • 2000
  • A case of primary hyperparathyroidism due to parathyroid adenoma is presented. A 14 year-old male was admitted to the hospital comptaining of voiding difficulty. The intravenous pyelogram demonstrated a stone in the proximal one third of the left ureter and marked hydronephrosis of the left kidney. The Tc-99m sestamibi nuclear scan demonstrated a hot spot below the lower pole of the left lobe of the thyroid. Laboratory study demonstrated hypercalcemia (12.4 mg/dL) and elevated parathyroid hormone (143.67 pg/mL). A parathyroid gland located below the lower pole of the left lobe of the thyroid was excised. A parathyroid adenoma, consisting of mainly chief cells was found on pathologic examination. Postoperatively the patient had transient hypocalcemic symptoms, which resolved with administration of calcium preparation and vitamin D.

  • PDF

The Parathyroid Gland: An Overall Review of the Hidden Organ for Radiologists (부갑상선: 부갑상선 영상에 익숙하지 않은 영상의학과 의사들을 위한 전반적인 검토)

  • Suho Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim;Myoung Kyoung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.327-344
    • /
    • 2024
  • Parathyroid glands are small endocrine glands that regulate calcium metabolism by producing parathyroid hormone (PTH). These are located at the back of the thyroid gland. Typically, four glands comprise the parathyroid glands, although their numbers may vary among individuals. Parathyroid diseases are related to parathyroid gland dysfunction and can be caused by problems with the parathyroid gland itself or abnormal serum calcium levels arising from renal disease. In recent years, as comprehensive health checkups have become more common, abnormal serum calcium levels are often found incidentally in blood tests, after which several additional tests, including a PTH test, ultrasonography (US), technetium-99m sestamibi parathyroid scan, single-photon-emission CT (SPECT)/CT, four-dimensional CT (4D-CT), and PET/CT, are performed for further evaluation. However, the parathyroid gland remains an organ less familiar to radiologists. Therefore, the normal anatomy, pathophysiology, imaging, and clinical findings of the parathyroid gland and its associated diseases are discussed here.

Management of Recurrent Thyroid Carcinoma with Negative Diagnostic Radioiodine Whole-Body Scan (진단적 방사성옥소 전신스캔이 음성인 갑상선 재발암의 진료)

  • Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.117-124
    • /
    • 2001
  • Serum thyroglobulin measurement and I-131 whole-body scintigraphy (WBS) are well-established methods for the detection of recurrence in the follow-up of patients with thyroid carcinoma. However, inconsistent results are observed frequently, and these two methods are not always able to detect recurrence. In some patients, serum thyroglobulin level is elevated but the WBS is negative, because the recurrent tumor is too small and below the sensitivity of the diagnostic scan, or there is a dissociation between thyroglobulin synthesis and the iodine frapping mechanism. In such cases, various nuclear imaging methods including Tl-201 Tc-99m-sestamibi, and F-18-FDG PET can be used besides anatomical imaging methods. Among them, FDG PET localizes recurrent lesions in WBS-negative thyroid carcinoma with high accuracy. Several studies have suggested that empirical high-dose I-131 therapy resulted in a high rate of visualization in post-therapy scans with evidence of subsequent improvement. An important question is when to operate on patients with recurrent tumor. We believe that surgical removal is the best means of treatment for patients with localized persistent tumor, despite the high-dose I-131 therapy. with tumor in thyroid remnant, and with isolated recurrence in the lymph node, lung or bone. In addition, we recommend palliative resection of locally unresectable mass with subsequent treatment with high-dose I-131 therapy. Before I-131 therapy, the evaluation of sodium-iodide symporter expression in thyroid carcinoma can predict iodine uptake. Retinoic acid is known to induce redifferentiation, and to enhance I-131 uptake in thyroid carcinoma. Retinoic acid therapy may represent an alternative approach before high-dose I-131 therapy.

  • PDF