• Title/Summary/Keyword: Tc-99m MIBI SPECT

Search Result 90, Processing Time 0.024 seconds

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

Synthesis Characterization and Biodistribution of $^{99m}Tc$-Ethyl-3-Isocyanobutyrate as a New Myocardial Perfusion Agent (새로운 심관관류 영상 화합물로서 $^{99m}Tc$-Ethyl-3-Isocyano-butyrate의 합성, 표지 및 체내동태에 대한 연구)

  • Lee, Myung-Chul;Cho, Jung-Hyuck;Lee, Dong-Soo;Lim, Sang-Moo;Oh, Seung-Joon;Chung, Soo-Wook;Lee, Kyung-Han;Jeong, Jae-Min;Chung, June-Key;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.223-232
    • /
    • 1993
  • Technetium labeled isonitrile analogues are widely used as myocardial perfusion imaging agents. We synthesized and characterized a new isonitrile compound, ethyl 3-isocyanobutyrate(EIB). Proton and $^{13}C$ NMR spectroscopy and thin layer chromatography with a $C_{18}$ coat was performed. EIB was easily labeled with $^{99m}TcO_4^-$- with sodium dithionite. The labeling efficiency measured by RP-HPLC was over 95%. The labeled product was stable with dilution in normal saline and with prolonged incubation at room temperature. There was no formation of secondary products or free $^{99m}TcO_4^-$. In vivo kinetics study of $^{99m}Tc$ (I) labeled EIB in rabbits showed adequate myocardial uptake, good contrast against lung background, and relatively rapid liver clearance. The heart to lung ratio was over 2.5 and the heart to liver ratio was approximately from 0.4 to 5 at 60 minutes post injection. Hepatic clearance of $^{99m}Tc-MIBI$ was faster ($t_{1/2}$=6 minutes) than that of $^{99m}Tc-MIBI$. In vivo kinetics observed in dog was similar to that in rabbit but there was faster gallbladder filling, and thus lower liver background. SPECT imaging of the canine myocardium showed favorable imaging characteristics. However, biodistribution in mice demonstrated a myocardial % injected dose/organ of less than 0.1%. This was thought to be due to interspecies difference in plasma esterase activity. In human plasma, $^{99m}Tc$ ( I ) labeled EIB was stable for at least 2 hours, without production of secondary products by HPLC. We conclude that ethyl 3-isocyanobutyrate may be a potential new myocardial perfusion imaging agent and deserves further investigation as to its usefulness for clinical use.

  • PDF

Comparison between Myocardial Perfusion and Function in Rest State in Coronary Artery Disease - Dipyridamole $^{99m}Tc-MIBI$ SPECT and Rest Gated Blood Pool Scan - (관상동맥질환에서 휴식기의 심근관류 정도와 휴식기 심기능 변화의 비교 - Dipyridamole 부하 $^{99m}Tc-MIBI$ SPECT와 휴식기 Gated Blood Pool Scan -)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Bae, Sang-Kyun;Yang, Hyung-In;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 1992
  • Rest gated blood pool scan (Rest GBP scan) and dipyridamole $^{99m}Tc-MIBI$ SPECT were Performed in 34 patients with or suspected coronary artery disease. Both studies were performed within $2\sim32$ days (mean 8.1 days). A significant correlation was present between left ventricular ejection fraction (r= -0.7356, p<0.001) and peak ejection rate and peak filling rate in rest GBP scan and perfusion defect in MIBI SPECT. And there were acceptable correlations (0.05$26.2{\pm}10.8%$, severe hypokinesia, akinesia or dyskinesia in 16 regions: $78.2{\pm}23.7$, p<0.001). These data indicate there is a significant coupling between the degree of myocardial perfusion and the myocardial functional change in coronary artery disease.

  • PDF

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF

Detection of Multidrug Resistance Using Molecular Nuclear Technique (분자핵의학 기법을 이용한 다약제내성 진단)

  • Lee, Jae-Tae;Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.2
    • /
    • pp.180-189
    • /
    • 2004
  • Although the outcome of cancer patients after cytotoxic chemotherapy is related diverse mechanisms, multidrug resistance (MDR) for chemotherapeutic drugs due to cellular P-glycoprotein (Pgp) or multidrug-resistance associated protein (MRP) is most important factor in the chemotherapy failure to cancer. A large number of pharmacologic compounds, including verapamil, quinidine, tamoxifen, cyclosporin A and quinolone derivatives have been reported to overcome MDR. Single photon emission computed tomography (SPECT) and positron emission tomography (PET) are available for the detection of Pgp and MRP-mediated transporter. $^{99m}Tc$-MIBI and other $^{99m}Tc$-radiopharmaceuticals are substrates for Pgp and MRP, and have been used in clinical studies for tumor imaging, and to visualize blockade of PgP-mediated transport after modulation of Pgp pump. Colchicine, verapamil and daunorubicin labeled with $^{11}C$ have been evaluated for the quantification of Pgp-mediated transport with PET in vivo and reported to be feasible substrates with which to image Pgp function in tumors. Leukotrienes are specific substrates for MRP and $N-[^{11}C]acetyl-leukotriene$ E4 provides an opportunity to study MRP function non-invasively in vivo. SPECT and PET pharmaceuticals have successfully used to evaluate pharmacologic effects of MDR modulators. Imaging of MDR and reversal of MDR with bioluminescence in a living animal is also evaluated for future clinical trial. We have described recent advances in molecular imaging of MDR and reviewed recent publications regarding feasibility of SPECT and PET imaging to study the functionality of MDR transporters in vivo.

Performance of Gated Myocardial Perfusion SPECT to Diagnose Coronary Artery Disease (게이트 심근 관류 SPECT의 관상 동맥 질환 진단 성능)

  • Kang, Won-Jun;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.50-56
    • /
    • 1997
  • Gated SPECT can evaluate the regional wall motion of the heart. We evaluated the regional wall motion of the perfusion abnormality in conventional perfusion SPECT with gated SPECT. In case of suspicious perfusion abnormalities, we tried to differentiate the artifact from true abnormality in coronary vascular disease using gated SPECT. We thought that artifacts would have normal wall motion, whereas fixed defects with decreased wall motion would probably represent coronary artery disease. A total of 275 patients who were performed coronary angiography and T1-201 rest/Tc-99m MIBI dipyridamole stress gated SPECT within 2 months were enrolled. In coronary angiography, stenosis more than 50% was considered as coronary artery disease. After injection of 111MBq T1-201 rest image was obtained on triple head SPECT system. 370MBg Tc-99m MIBI was used for the stress image. Eight-frame per-cardiac-cycle gated Tc-99m SPECT studies were done. All the images were analyzed visually. Using perfusion SPECT, the overall sensitivity and specificity were 87% and 55% respectively. Regarding artery territory, sensitivity and specificity were 68% and 73% for left anterior descending artery(LAD), 62% and 78% for right coronary artery(RCA), 42% and 90% for left ciramflex artery(LCX). Using gated SPECT, the overall sensitivity and specificity were 87% and 66% respectively. Sensitivity and specificity were 68% and 78% for LAD, 62% and 79% for RCA, 42% and 90% for LCX. Among 21 false positive cases in perfusion SPECT, 5 cases were interpreted as true negative with gated SPECT. We conclude that gated SPECT provides a valuable adjunct to perfusion SPECT in characterizing perfusion abnormalities and to improve specificity.

  • PDF

The Correlation Analysis of Stress/Rest Ejection Fraction of $^{201}Tl$ Gated Myocardial Perfusion SPECT ($^{201}Tl$ 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Shim, Dong-Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.3-9
    • /
    • 2009
  • Purpose: It is well-known that stress-induced stunning and reversible perfusion defect have impact on ejection fraction (EF) when performing myocardial perfusion SPECT. Due to these reasons, gated SPECT is recommended at stress and rest studies. And there was many experiments to analyze between Stress and Rest EF by using $^{99m}Tc$-MIBI. The aim of this study is to analyze between stress EF and rest EF at myocardial perfusion SPECT by using $^{201}Tl$ and define possible predictors of EF variability. Materials and Methods: From 2008 June to 2009 February, we analyzed 144 patients undergoing $^{201}Tl$ gated myocardial perfusion SPECT in ASAN medical center. To analyze the data, we use QGS (Quantitative gated SPECT) software, and derived End-systolic volume (ESV), End-diastolic volume (EDV), EF from the result. In this study, we comparatively analyzed stress/rest EF correlation based on stress/rest EF, EDV, ESV and reversibility of myocardial perfusion defect by using paired t-test, Bland-Altman analysis. Results: Mached pairs of stress EF and rest EF demonstrated excellent correlation (r=0.92) with no statistically significant difference (p=0.11). Bland-Altman analysis demonstrated a mean ${\Delta}EF$ was 0.52% (95% confidential interval[CI], -1.17~0.12%). No statistically significant difference between a mean ${\Delta}EF$ and hypothetic mean of 0 (${\Delta}EF$=0) (p=0.10). In the correlation of ${\Delta}EF$ according to stress/rest EDV and ESV, except rest ESV of <28mL (p<0.05), there was no statistically significant difference. In the correlation of ${\Delta}EF$ according to reversibility of perfusion defect, patients with reversible perfusion defect has statistically significant difference of ${\Delta}EF$ (p<0.05). ${\Delta}EF$ of stress/rest EF showed no statistically significant difference except 55% of rest EF (p<0.05). Conclusion: Like studies with $^{99m}Tc$-MIBI, there was generally no statistically significant difference between stress and rest EF in this study results. However a stress EF of <55%, a rest ESV of <28mL and patients with reversible perfusion defect showed statistically significant difference in ${\Delta}EF$. If performing $^{201}T$ myocardial perfusion SPECT to patients with abnormal cardiac function or reversible perfusion defect, consider this study results and apply it. We expect this study results could be useful predictors of ${\Delta}EF$ variability.

  • PDF