• Title/Summary/Keyword: Tc-99m DTPA

Search Result 100, Processing Time 0.029 seconds

Effectiveness of Radionuclide Cisternography to Detect the Leakage Site of CSF in Spontaneous Intracranial Hypotension; Preliminary Report (자발성 두개강내 저뇌압증 환자의 뇌척수액 누출부위 진단에 방사성동위원소 뇌조조영술의 유효성: 예비결과 보고)

  • Kim, Seong-Min;Kim, Jae-Moon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.148-154
    • /
    • 2006
  • Purpose: Although radionuclide cisternography (RNC) is an useful study to detect cerebrospinal fluid (CSF) leakage in the patient with spontaneous intracranial hypotension (SIH), it sometimes fails to demonstrate the site of CSF leakage. The aim of the study is to improve the detection of leakage site of CSF and to reduce time for the study in RNC using modified protocol (m-RNC). Materials & methods : The study consists of 8 studies of 7 patients ($38{\pm}8$ years, M:F=2:5) with SIH, who underwent m-RNC following administration of 185-222 MBq of $^{99m}Tc$-DTPA into the lumbar subarachnoid space. Sequential images were obtained the whole spine with the head including urinary bladder at 10 minute, 30 minute, 1 hour, 2 hour, 4 hour and 6 hour. Radioactivity of extradural space and urinary bladder was evaluated. Results: Leakage site of CSF was identified in all 8 cases by m-RNC. Leakage site was cervicothoracic junction (CTJ, n=3), CTJ with C1-2 (n=2), CTJ with thoracic spine, thoracolumbar spine and lumbar spine (each n=1). All cases presented leakage sites within 1 hour and multiple sites, where CTJ was included in 6 cases. Only one case presented additional site in 6 hour image. Early radioactivity within the urinary bladder was noted in 6 cases, but that was fellowing after identification of the leakage site. Conclusion: Radionuclide cisternography is sensitive to detect the leakage site of CSF and is expected to improve the detection of CSF leakage site and reduce time for the study using modified protocol.

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.

A Case of Spontaneous Intracranial Hypotension: Detection of Cerebrospinal Fluid Leakage by Early Dynamic Radionuclide Cisternography (방사성핵종 뇌조조영술의 조기 동적 영상으로 뇌척수액 누출을 증명한 자발성 두개 내 저압 1예)

  • Kim, Jae-Soo;Yang, Dae-Woong;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.184-188
    • /
    • 1999
  • Although cerebrospinal fluid leakage is suggested as one of the causes of spontaneous intracranial hypotension, only a few cases with direct evidence of cerebrospinal fluid leakage on radionuclide cisternography have been reported in the literature. Indirect evidences of cerebrospinal fluid leakage such as early visualization of the soft tissue and bladder or delayed migration of radiotracer have been observed in most patients with spontaneous intracranial hypotension. We report a case of spontaneous intracranial hypotension in which cerebrospinal fluid leakage was directly demonstrated by early dynamic imaging of spine on radionuclide cisternography. We suggest that early dynamic imaging of spine is an important adjunctive procedure in detecting cerebrospinal fluid leakage in patients with spontaneous intracranial hypotension.

  • PDF

Radioisotope Perfusion Lung Scanning in Takayasu's Arteritis (Takayasu 동맥염에서 폐관류스캔에 관한 연구)

  • Park, Seok-Gun;Bom, Hee-Seung;Oh, Yeon-Sang;Han, Jin-Suk;Chung, June-Key;Choi, Sung-Jae;Kim, Byung-Kook;Lee, Jung-Sang;Lee, Young-Woo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.73-78
    • /
    • 1986
  • Of 18 patients with Takayasu's arteritis who underwent $^{99m}Tc-MAA$ (macroaggregated albumin) perfusion luing scanning, 9 (50%) showed perfusion defects. Chest X-rays of them were nonspecific. One patient underwent $^{99m}Tc-DTPA$ radio aerosol inhalation lung scanning simultaneously, which revealed normal. So routine screening radioisotope perfusion lung scanning is helpful to evaluate pulmonary arterial involnmement in Takayasu's arteritis patients. And Takayasu's arteritis should be included in differential diagnosis of pulmonary embolism.

  • PDF

Captopril $^{99m}Tc-DTPA$ Renal Scintigraphy in Diagnosis of Renovascular Hypertension (신혈관성 고혈압의 진단에 있어서 캅토프릴 신스캔의 의의)

  • Yang, Hyung-In;Lee, Dong-Soo;Kim, Sung-Chul;Bae, Sang-Kyun;Choi, Chang-Woon;Chung, June-Key;Kim, Suhng-Gwon;Lee, Myung-Chul;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.312-317
    • /
    • 1992
  • To evaluate the sensitivity and specificity of captopril renal scan for renovascular hypertension, we employed the captopril renal scan in conjunction with renal angiography in 81 patients, 159 kidneys, who were referred to evaluate the cause of hypertension. We defined the renovascular hypertension by the criteria of demonstration of renal artery stenosis by angiography, and improvement or cure of hypertension by revascularization. Visual and quantitative evaluation of $^{99m}Tc-DTPA$ renal scan was peformed pre and post captopril administration. The prevalence rate of renovascular hypertension was 40% in comparing with renal angiography, and 70% in confirmed cases. The causes of renovascular hypertension in 81 patients were Takayasu's arteritis, fibromuscular dysplasia, atherosclerosis, essential hypertension, chronic pyetonephritis etc. The sensitivity and specificity of captopril renal scan in comparing with renal angiography were 80%, 86.5%, respectively and also 84.2%, 72.6% in confirmed cases of renovascular hypertension, respectively. The causes of false negative cases were nonfunctioning kidney due to complete obstruction or long duration of disease in basal scan, segmental branch artery stenosis, unknown causes, and suspicious true negative cases without confirmation. The false positive cases were abdominal aortic stenosis or aneurysm, dehydration, unknown causes, and suspicious true positive cases. We conclude that captopril renal scintigraphy is highly sensitive, reasonably specific diagnostic method and comparable to other techniques very favorably.

  • PDF

Development of Formulas for the Estimation of Renal Depth and Application in the Measurement of Glomerular Filtration Rate in Koreans (사구체 여과율 측정을 위한 한국인의 신장 깊이에 관한 방정식 도출과 이용)

  • Yoo, Ie-Ryung;Kim, Sung-Hoon;Chung, Yong-An;Jung, Hyun-Seok;Lee, Hae-Giu;Park, Young-Ha;Lee, Sung-Yong;Sohn, Hyung-Seon;Chung, Soo-Kyo;Kim, Hyun-Mi;Lee, Hyung-Goo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.418-425
    • /
    • 2000
  • Purpose: There is no established formula for estimating renal depths in Korean. As a result, we undertook this study to develop a new formula, and to apply this formula in the calculation of glomerular filtration rate (GFR). Materials and Methods: We measured the renal depth (RD) on the abdominal CT obtained in 300 adults (M:F: 167:133, mean age 50.9 years) without known renal diseases. The RDs measured by CT were compared with the estimated RDs based on the Tonnesen and Taylor equations. New formulas were derived from the measured RDs in 200 out of 300 patients based on several variables such as sex, age, weight, and height by multiple regression analysis. The RDs estimated from the new formulas were compared with the measured RDs in the remaining 100 patients as a control. In 48 patients who underwent Tc-99m DTPA renal scintigraphy, GFR was measured with three equations (new formula, Tonnesen and Taylor equations), respectively, and compared with each other. Results: The mean values of the RDs measured from CT were 6.9 cm for right kidney of the men (MRK), 6.7 cm for left kidney of the men (MLK), 6.7 cm for right kidney of the women (WRK), and 6.6 cm for left kidney of the women (WLK). The RDs estimated from Tonnesen equation were shorter than the ones measured from CT significantly. The newly derived formulas were 12.813 (weight/height)+0.002 (age)+ 2.264 for MRK, 15.344 (weight/height)+0.011 (age)+0.557 for MLK, 12.936 (weight/height)+ 0.014 (age)+1.462 for WRK and 13.488 (weight/height)+0.019 (age)+0.762 for WLK. The correlation coefficients of the RD measured from CT and estimated from the new formula were 0.529 in MRK, 0.729 in MLK, 0.601 in WRK, and 0.724 in WLK, respectively. The GFRs from the new formula were significantly higher than those from the Tonnesen equation significantly, which was the most similar to normal GFR values. Conclusion: We generated new formulas for estimating RD in Korean from the data by CT. By adopting these formulas, we expect that GFR can be measured by the Gates method accurately in Korean.

  • PDF

Reducing the Scan Time in Gastric Emptying Scintigraphy by Using Mathematical Models (위배출 신티그래피에서 수학적 모델을 이용한 지연영상 시간의 단축)

  • Yoon, Min-Ki;Hwang, Kyung-Hoon;Choe, Won-Sick;Lee, Byeong-Il;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.257-262
    • /
    • 2005
  • Purpose: Gastric emptying scan (GES) is usually acquired up to 2 hours. Our study investigated whether a fraction of meal-retention in the stomach at 120 minutes (FR120) was predicted from the data measured for 90 minutes by using non-linear curve fitting. We aimed at saving the delayed imaging by utilizing mathematical models. Materials and Methods: Ninety-six patients underwent GES immediately after taking a boiled egg with 74 MBq (2 mCi) Tc-99m DTPA. The patients were divided into Group I ($T_{1/2}\;{\leq}90\;min$) and Group II ($90\;min). Group I (n=51) had 21 men and 30 women, and Group II (n=45) 15 men and 30 women. There was no significant difference in age and sex between the two groups. Simple exponential, power exponential, and modified power exponential curves were acquired from the measured fraction of meal-retention at each time (0, 15, 30, 45, 60, 75, and 90 min) by non-linear curve fitting ($MATLAB^{\circledR}$ 5.3) and another simple exponential fitting was performed on the fractions at late times (60, 75, and 90 min). A predicted FR120 was calculated from the acquired functional formulas. A correlation coefficient between the measured FR120 and the predicted FR120 was computed ($MedCalc^{\circledR}$ 6.0). Results: Correlation coefficients(r) between the measured FR120 and the predicted FR120 of each mathematical functions were as follows: simple exponential function (Group I: 0.8558, Group II: 0.5982, p<0.0001), power exponential function (Group I: 0.8755, Group II: 0.6008, p<0.0001), modified power exponential function (Group I: 0.8892, Group II: 0.5882, p<0.0001), and simple exponential function at the late times(Group I: 0.9085, Group II: 0.6832, p<0.0001). In all the fitting models, the predicted FR120 were significantly correlated with the measured FR120 in Group I but not in Group II. There was no statistically significant difference in correlation among the 4 mathematical models. Conclusion: In the cases with $T_{1/2}\;{\leq}90\;min$, the predicted FR120 is significantly correlated with the measured FR120. Therefore, FR120 can be predicted from the data measured for 90 minutes by using non-linear curve fitting, saving the delayed imaging after 90 minutes when $T_{1/2}\;{\leq}90\;min$ is ascertained.

GFRs Measured by Gates' Method According to 5 Background Sites: Comparison with GFR Measured by I-125-Iothalamate Method (다양한 배후 방사능 설정에 따른 Cates 법 사구체 여과율의 차이: I-125-Iothalamate 측정법과의 비교)

  • Jung, Hyun-Seok;Chung, Yong-An;Kim, Sung-Hoon;Kim, Chung-Ho;Lee, Sung-Young;Sohn, Hyung-Seon;Baik, Jun-Hyun;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.306-310
    • /
    • 2004
  • Purpose: The aim was to assess how the background site affects the Gates' glomerular filtration rate(GFR) measurement using Tc-99m-DTPA in correlation with GFR by I-125-lothalamate method. Material and methods: The study populations were 63 adults with 39 men and 24 women aged from 20 to 59 yrs (mean=37.9 yrs). The fellowing five background regions of interest were used in measurement of GFR using Gates' method: 1) lower side of each kidney(subrenal), 2) around each kidney(circumferential), 3) upper side of each kidney(suprarenal), 4) lateral side of each kidney(lateral), 5) between the two kidneys(inter-renal). We also measured GFR using I-125-iothalamate in each subject. The two studies were separated by 1 to 3 weeks. The subjects were divided into two groups by renal depth. Group 1 with renal $depth{\geq}7cm$ and group 2 with renal depth<7cm. We calculated the means and standard deviations of the GFRs measured by two studies. And we statistically analyzed the correlation and differences among GFRs by Gates' method and the GFR by iothalamate method with correlation analysis. Results: The GFRs by Gates' method using suprarenal and inter-renal background correction showed better correlation with the GFR measured by I-125-iothalamate. And GFRs measured by Gates' method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm. But GFRs measured by Gates' method did not show statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal $depth{\geq}7cm$. Conclusion: GFRs measured with Gates' method showed higher correlation with the GFR measured by I-125-iothalamate when the regions of interest were plated over the suprarenal and inter-renal backgrounds. And GFRs measured with Gates method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm.

Diagnostic Criteria of $^{99m}Tc$-diethylenetriaminepentaacetic acid Captopril Renal Scan for the Diagnosis of Renovascular Hypertension by Unilateral Renal Artery Stenosis ($^{99m}Tc$-diethylenetriaminepentaacetic acid 캅토프릴 신장스캔의 단측 신동맥 협착에 의한 신혈관성고혈압 진단 기준)

  • Choi, Seung-Jin;Hong, Il-Ki;Chang, Jae-Won;Park, Su-Kil;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.498-505
    • /
    • 2004
  • Purpose: We compared captopril renal scintigraphic criteria for the diagnosis of renovascular hypertension by unilateral renal artery stenosis. Materials and Methods: The study group consisted of 24 patients (m/f : 16/8, age: $39{\pm}18$ years) with unilateral renal artery stenosis who underwent renal artery revascularization and captopril renal scintigraphy with $^{99m}Tc$-diethylenetriaminepentaacetic acid between May 1995 and April 2004. The blood pressure response was classified as cure/improvement or failure. We evaluated captopril-induced changes in relative function (BCfun) and renogram grade (0 to 5: 0=normal, and 5=renal failure pattern without measurable uptake) (CBren) and the difference of renograms between the normal and stenotic kidney on captopril scan (CNren). Results: light of 24 patients were cured and 11 improved and 5 patients were classified as failed revascularization. Significant predictors of a cure or improvement of blood pressure were younger age, stenosis by fibromuscular dysplasia or arteritis, BCfun, CBren and CNren. Areas under the receiver operating characteristic curve of age, BCfun, CBren and CNren were not significantly different. Positive and negative predictive values of predictors were 100% and 42% (age ${\leq}38$): 92% and 50% (BCfun ${\geq}1%$): 92% and 75% (CBren ${\geq}1$), and 90% and 60% (CNren ${\geq}1$), respectively. Conclusion: Captopril induced changes in renal function and renogram can reliably predict hypertension response to revascularization. Renogram pattern on captopril scan can diagnose renovascular hypertension without baseline data in patients with unilateral renal artery stenosis.

The Effect on The Result, in Case of the In-vitro Test Performance after an Imaging Test (핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향)

  • Moon, Ki Choon;Kwon, Won Hyun;Kim, Jung In;Lee, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.149-152
    • /
    • 2014
  • Purpose: At our hospital blood is collected from a patient before an imaging test, with the concern of any effect possible when a nuclear medicine imaging test and an in-vitro test are carried out at the same time. However, occasionally, the blood collection is performed after an imaging test, with the reasons that the patient is not properly guided or the patient doesn't follow the guide correctly. In that case, we prefer to gather blood again after a few days. The purpose of this study is not only to see whether there is any effect of an imaging test on the result of the in-vitro test performed with the blood collected after the imaging test, but also to study how many days waiting after each test is appropriate to take a blood sample, if the effect exists. Materials and Methods: From September to October 2013, blood were collected from 13 patients in our hospital regardless of age and sex each time before and after the injection of the radioactive isotope from the tests : PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan. Considering a half-life, AFP, CA19-9, CEA, TSH, and T3 were carried out right after the blood collection. In case of an iodine therapy, blood were taken each time before and after taking radioactive iodine, and, after AFP, CA19-9, and CEA, the difference between them in consistency and in cpm were compared. Results: With 10 patients after the imaging tests and 3 patients after the iodine therapy, their serum cpm was over 10,000. Over time, the cpm decreased in accordance with the half-life ($^{18}F$ 110minutes, $^{99}mTc$ 6hours, $^{201}Tl$ 72hours, $^{131}I$ 7days). Between the two cases, one before and the other after the injection of the radioactive isotope, the cpm and the results of AFP, CA19-9, CEA, TSH, and T3 from three patients each test, PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan, were very similar. In addition, in case of an iodine therapy, there was also not a meaningful difference in the cpm and the results of AFP, CA19-9, and CEA, from three patients in an iodine therapy, between the two cases, one before and the other after taking the radioactive iodine. Conclusion: In case a blood collection was performed after the imaging test which required a radioactive isotope injection, the cpm increased, differently according to the kind of the radioactive isotope. However, the results of the in-vitro tests like AFP, CA19-9, CEA, TSH, T3, etc were nearly not affected. As the result, it's considered that there will not be any significant effect also from other tests, as the result from the performed seven tests.

  • PDF