• Title/Summary/Keyword: Tc-99 m

Search Result 1,347, Processing Time 0.027 seconds

Recurrent Malignant Thymoma Detected by Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA Scan (Tc-99m MIBI, Tc-99m Tetrofosmin, 그리고 Tc-99m (V) DMSA 스캔에 의해 발견된 재발성 악성 흉선종)

  • Seok, Ju-Won;Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.268-273
    • /
    • 2001
  • Thymoma is the most common primary tumor of anterior mediastinum, accounting for 20% to 30% of all mediastinal tumors. The recurrence rate after total resection of the thymoma ranges 8% to 18%. We reported one patient of recurrent malignant thymoma imaged with Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA. Early and delayed Tc-99m MIBI and Tc-99m Tetrofosmin scintigraphies showed an increased uptake in the mediastinal area. Also, Tc-99m (V) DMSA scintigraphy revealed an increased uptake tn the corresponding area. Coronal SPECT images of Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA revealed increased uptake of each radiopharmaceutical in the tumor lesion corresponding to the mediastinal lesion on the chest CT. However, the normal blood pool activities of the heart and great vessels of Tc-99m (V) DMSA obscured the recurrent malignant thymoma. Although Tc-99m (V) DMSA is a useful tumor seeking agent, we recommend Tc-99m MIBI and Tc-99m Tetrofosmin SPECT rather than Tc-99m (V) DMSA to detect primary and recurrent malignant thymoma.

  • PDF

$^{99m}Tc$-Tetrofosmin Scintimammography in Suspected Breast Cancer Patients: Comparison with $^{99m}Tc$-MIBI (유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin을 이용한 유방스캔: $^{99m}Tc$-MIBI와 비교)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.119-128
    • /
    • 2000
  • Purpose: The aim of this study was to investigate the diagnostic role of $^{99m}Tc$-Tetrofosmin in detection of breast cancer and compared with that of $^{99m}Tc$-MIBI. Material and Methods: Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Results: Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}Tc$-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-Tetrofosmin were 31,10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of $^{99m}Tc$-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin acintimammographies and its size was 0.5 cm. Conclusion: $^{99m}Tc-Tetrofosmin\;and\;^{99m}Tc-MIBI$ were non-invasive and useful in detection of breast cancer and $^{99m}Tc$-Tetrofosmin was comparable to the $^{99m}Tc$-MIBI in detection of primary breast cancer.

  • PDF

A Convenient Method on the Methyl-Ethyl-Ketone Extraction of $^{99m}TcO^-{_4}$ ($^{99m}TcO^-{_4}$의 메틸-에틸-케톤-간편 추출법)

  • Lee, Jong-Du;Lee, Byung-Hyn
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.103-111
    • /
    • 1984
  • A convenient method of $^{99m}Tc$-methyl-ethyl-ketone (MEK) extraction technique was developed and a mobile $^{99m}Tc$-extraction generator was designed. The MEK extraction and the phase separation of $^{99m}TcO^-{_4}$ were carried out with a simple procedure in the same container. The shielding of $^{99}Mo$ radioactivity was made with one lead container. The system was simplified by shielding $^{99m}TcO_4{^-}({\gamma}_e=0.14\;MeV)$ separately. $^{99m}TcO^-{_4}\;in\;^{99m}Tc-MEK$ extract was recovered by adsorption and elution only, and therefore, the possibility of volatilization was reduced. The volume of $^{99m}TcO^{-}{_4}$-saline product was reduced to 1 ml by using a small alumina column and the column operation time was shortened. The separation time of $^{99m}Tc$ was reduced to 30 minutes, and the operation was carried out at the outside of the shielding. The system was designed to operate under the condition of bacteria-free.

  • PDF

Camparison of the Efficiency for Tc-99m Tin-colloid and Tc-99m Phytate in Sentinel Node Detection in Breast Cancer Patients (유방암 환자의 전초림프절 검사에서 Tc-99m Tin-colloid와 Tc-99m Phytate의 효용성에 대한 비교)

  • Seok, Ju-Won;Kim, In-Ju
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.451-455
    • /
    • 2008
  • Purpose: Lymphoscintigraphy and sentinel node biopsy has become a standard method for detection of axillary lymph node metastasis in breast cancer patients, but the standard radiopharmaceutical was not prepared. About detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy in breast cancer patient, we compared the results of Tc-99m Tin-colloid and Tc-99m Phytate by subareolar injection. Materials and Methods: This study included 382 breast cancer patients who were performed operation during 2001-2008. Three hundred forty nine patients was injected 0.8ml of Tc-99m Tin-colloid (37-185 MBq) by subareolar injection. Thirty three patients was injected 0.8ml of Tc-99m Phytate (37-185 MBq). Lymphoscintigraphy was performed in supine position and sentinel node localization was performed by hand-held gamma probe in operation. Result: Among 349 patients by Tc-99m Tin-colloid, 312 cases (89.4%) localized the sentinel node by lymphoscintigraphy, 304 cases (87.1%) localized by gamma probe. Among 33 patients by Tc-99m Phytate, 32 cases (97.0%) localized by lymphoscintigraphy, 33 cases (100%) localized by gamma probe. Detection rate by lymphoscintigraphy and gamma probe was superior for Tc-99m Phytate compared to that with Tc-99m Tin-colloid, with a statistically significant difference. (p<0.05, p<0.05) Conclusion: Tc-99m Phytate is a better choice for localization of sentinel node than Tc-99m Tin-colloid in breast cancer patients.

Fibrous Dysplasia Associated with Primary Hyperparathyroidism Absent of McCune-Albright Syndrome: Tc-99m MIBI and Tc-99m MDP Findings

  • Kim, Seong-Jang;Seok, Ju-Won;Kim, In-Ju;Kim, Yong-Ki;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.128-134
    • /
    • 2003
  • 섬유성 골이형성증은 비정상적인 섬유성 골조직으로 대체되며 느리게 진행하는 골병변이다. 섬유성 골이형성증과 부갑상선기능항진증은 흔하게 관찰되는 질환이나 McCune-Albright 증후군 없이 일차성 부갑상선기능항진증에 동반된 섬유성 골 이형성증은 거의 보고된바가 없다. Tc-99m MDP 골스캔이 섬유성 골이형성증의 진단에 유용하다고 알려져 있으나, Tc-99m MIBI 영상은 아직 보고된 바가 없다. 저자들은 McCune-Albright 증후군이 없이 부갑상선기능항진증에 동반된 섬유성 골 이형성증의 Tc-99m MIBI 스캔과 Tc-99m MDP 골스캔의 영상을 비교하였다. Tc-99m MDP 골스캔상 병변 부위에서 증가된 섭취 소견을 보였으며, Tc-99m MIBI 조기영상에서도 동일한 위치에서 섭취증가가 관찰되었다. 2시간 지연 Tc-99m MIBI 영상에서는 Tc-99m MIBI의 섭취가 배출되는 소견을 보였다. 섬유성 골이형성증 병변에서 Tc-99m MIBI 스캔이 유용할 것이라고 생각하며, 섬유성 골이형성증 병변에서 Tc-99m MIBI의 섭취를 증가시키는 인자에 대한 더 많은 연구가 필요할 것으로 생각한다.

Studies on the Stability of $Methylenediphosphonate-^{99m}Tc$ (Methylenediphosphonate $(MDP)-^{99m}Tc$의 안정도(安定度)에 관(關)한 연구(硏究))

  • Kim, Jae-Rok;Awh, Ok-Doo;Park, Kwung-Bae;Koo, Hyeon-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.81-84
    • /
    • 1982
  • To evaluate the in-vivo and in-vitro stability of methylene diphosphonate $(MDP)-^{99m}Tc$, relative ligand exchange rates in phosphate buffer between $MDP-^{99m}Tc$ and human serum albumin (HSA), and between pyrophosphate$(PYP)-^{99m}Tc$ and HSA have been measured. Gel permeation chromatography has also been carried out to estimate relative rates of ligand exchange between polysaccharide and the $^{99m}Tc-bone$ agents. The in-vitro stability was further correlated with its specific radioactivity. The results indicated that the $MDP-^{99m}Tc$ is more stable than the $PYP-^{99m}Tc$ but less stable than $MIDA-^{99m}Tc$, $HIDA-^{99m}Tc$, and $DTPA-^{99m}Tc$ etc. in refering to other data. In stability point of view, $MDP-^{99m}Tc$ is considered to be a better bone agent than $PYP-^{99m}Tc$ since $MDP-^{99m}Tc$ can be accumulated at bone by a smooth transfer of $^{99m}Tc$ to hydroxyapatite, whereas in case of $PYP-^{99m}Tc$, most of the $^{99m}Tc$ is transferred to HSA before arriving to the hydroxyapatite.

  • PDF

Comparison of Radiation Adaptive Responses in Peripheral Lymphocytes of Patients Undergoing Tc-99m MDP and Tc-99m DTPA Scintigraphies (Tc-99m MDP와 Tc-99m DTPA 신티그라피를 시행한 환자의 말초혈액 림프구에서 유도되는 방사선 적응반응의 비교)

  • Bom, Hee-Seung;Li, Ming-Hao;Min, Jung-Jun;Kwon, An-Sung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.252-259
    • /
    • 2000
  • Purpose: The purpose of this study was to compare the radiation adaptive response (RAR) in peripheral lymphocytes (PL) of patients induced by Tc-99m MDP and Tc-99m DTPA scintigraphies. Materials and Methods: Lymphocytes from 45 patients (25 males, 20 females, mean age $44{\pm}18$ years) were collected before and after scintigraphies using 740 MBq Tc-99m MDP (n=22) or Tc-99m DTPA (n=23). Lymphocytes from 20 controls (12 males, 8 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy ${\gamma}-rays$ using a Cs-137 cell irradiator Number of ring-form (R) and dicentric (D) chromosomes was counted under the light microscope. From them a representative score, Ydr, was calculated as Ydr=(D+R)/cells. Adaptation index (AI) was defined as difference of Ydr between unconditioned and conditioned lymphocytes. Ydr was also measured after an administration of cycloheximide (CHM), a protein synthesis inhibitor, before challenge dose. Results: RAR was induced in both groups of patients. CHM abolished the adaptive response in both groups. AI of Tc-99m MDP group was significantly higher than that of Tc-99m BTPA group. Conclusion: Tc-99m MDP induced RAR was more prominent than those induced by Tc-99m DTPA.

  • PDF

Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP ($Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Young-Ju;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.361-366
    • /
    • 1996
  • This study was to determine the effect of $Al^{3+}$ in $^{99m}Tc$ eluate from $^{99}Mo-^{99m}Tc$ generator on labeling efficiency and biodistribution of $^{99m}Tc$-MDP. The chromatographic analysis of $^{99m}Tc$-MDP preparations containing $Al^{3+}(0-62.5{\mu}g/ml)$ showed decreased labeling efficiency $^{99m}Tc$ pertechnetate and hydrolyzed reduced $^{99m}Tc$ fraction increased with increasing concentrations of aluminum. However, the chromatography system could not discern between hydrolyzed reduced $^{99m}Tc$ and $^{99m}Tc$ labeled colloid. $^{99m}Tc$-MDP preparations containing aluminum were relatively stable. Chromatographic analysis also confirmed that no significant differences were observed in the radiochemical purity of the filtered and the unfiltered $^{99m}Tc$-MDP preparations containing aluminum by $0.22{\mu}m$ syringe filter. In biodistribution data of ICR-mice, blood and heart uptake were increasing with increasing concentrations of aluminum, because of decreasing labeling efficiency of $^{99m}Tc$-MDP and increasing of $^{99m}Tc$ pertechnetate. However, liver and bone uptake were not significantly increased. In rat images no difference were observed at $5{\mu}g/ml\;Al^{3+}$ compare with at $0{\mu}g/ml\;Al^{3+}$, but at $10{\mu}g/ml\;Al^{3+}$ lumbar uptake was increased. As a practical conclusion, a concentration below $10{\mu}g/ml\;Al^{3+}$($10{\mu}g/ml\;Al^{3+}$ is the maximum allowed in pertechnetate eluate from $^{99}Mo-^{99m}Tc$ generator by USP.) in $^{99m}Tc$-MDP radiopharmaceutical result in low labeling efficiency. Radiochemical purity 90% of $^{99m}Tc$-MDP is the minimum allowed by USP. Therefore, when soft tissue uptake is observed in $^{99m}Tc$-MDP bone scan and labeling efficiency is above 90%, we can expect that $Al^{3+}$ in pertechnetated eluate is not the cause of soft tissue uptake.

  • PDF

The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism (원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성)

  • Baik, S.H.;Kim, S.M.;Choi, K.M.;Choi, Y.S.;Kim, S.J.;Yu, J.M.;Choi, D.S.;Choe, J.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.465-472
    • /
    • 1995
  • An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  • PDF

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF