• Title/Summary/Keyword: Tapping test

Search Result 77, Processing Time 0.027 seconds

A Tapping the usefulness of Whole Blood Interferon-${\gamma}$ Assay for Diagnosing Tuberculosis Infection in Children (소아 결핵 감염 진단에 있어서 결핵 특이항원 자극 Interferon-${\gamma}$ 분비능 측정의 진단적 유용성)

  • Soon, Eu-Gene;Lim, Baek-Keun;Kim, Hwang-Min;NamGoong, Mee-Kyung;Cha, Byung-Ho;Uh, Young;Chun, Jin-Kyong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.5
    • /
    • pp.280-285
    • /
    • 2010
  • Background: $QuantiFERON^{(R)}$-TB Gold In Tube (QFT-G IT) has been used for diagnosing latent tuberculosis infection and active tuberculosis (TB) since 2007. However, there has not been enough data on QFT-G IT for universal use in children. In this study, we evaluated the clinical usefulness of the QFT-G IT in pediatric practice. Methods: We retrospectively reviewed the clinical records of 70 patients younger than 18 years of age who had taken QFT-G IT and had a tuberculin skin test (TST) between July 2007 and July 2009 at Wonju Christian Hospital. The subjects were divided into two groups, asymptomatic TB exposure group and disease group. Four patients who were taking immunosuppressants during the study period were excluded. Results: A total of 66 immunocompetent children were included in this study. Among 27 asymptomatic children who had contact histories of TB, 6 (22.2%) were found to be positive by QFT-G IT. Eleven (40.7%) and 5 (18.5%) children were found to be positive by TST with cutoff values of ${\geq}5mm$ and ${\geq}10mm$, respectively. Agreement was fair to good between QFT-G IT and TST (${\kappa}=0.59$: cutoff value ${\geq}5mm$, ${\kappa}=0.7$: cutoff value ${\geq}10mm$). In disease group, 14 patients (35.9%) were diagnosed with active tuberculosis, 8/14 (57.1%) were positive on TST and 9/14 (64.3%) on QFT-G IT. The positive rate of acid-fast bacilli smear, TB-polymerase chain reaction, and culture for tuberculosis was 11% (1/9), 27.3% (3/11) and 33.3% (3/9), respectively. Conclusion: Our data support that the QFT-G IT can be used as an additional diagnostic tool for latent and active tuberculosis infection in children.

A Study on the Development of the Repair Standards for Underground Pipelines Carrying Natural Gas (도시가스 매설배관 보수기준 개발에 관한 연구)

  • Ryou, Young-Don;Lee, Jin-Han;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.33-43
    • /
    • 2016
  • Grinding, weld deposition, type A sleeve, type B sleeve, composite sleeve, hot tapping and clamp are used as the method to repair the buried pipelines in the United States, UK and Europe. In the event of defect to the pipeline, they have repaired the pipeline through the fitness-for-service assessments. In addition, they have guidelines for the possible repair methods to apply to each type of damage, which is occurred due to the 3rd party construction or corrosion. According to the KGS FS551, Safety Validation in Detail including ECDA(External Corrosion Direct Assessment) as one method of integrity management should be carried out for the old pipeline which supply natural gas as the middle pressure in Korea. Where a defect on the pipelines is found, on the result of Safety Validation in Detail, the pipelines should be repaired or replaced by new piping. However, there are no guidelines or regulations regarding the repair and reinforcement of pipeline, so that, cutting the damaged pipeline and replacing it as a segment of new pipe is the only way in Korea until now. We have suggested pipeline repair methods including type A, B sleeve, composite sleeve, after the survey of foreign repair method and standards including the method of United States and the United Kingdom, and after analysis of the results on pipeline repair test including type A, type B sleeve and composite sleeve.

A Study on the Improvement of Tool's Life by Applying DLC Sacrificial Layer on Nitride Hard Coated Drill Tools (드릴공구의 이종질화막상 DLC 희생층 적용을 통한 공구 수명 개선 연구)

  • Kang, Yong-Jin;Kim, Do Hyun;Jang, Young-Jun;Kim, Jongkuk
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.6
    • /
    • pp.271-279
    • /
    • 2020
  • Non-ferrous metals, widely used in the mechanical industry, are difficult to machine, particularly by drilling and tapping. Since non-ferrous metals have a strong tendency to adhere to the cutting tool, the tool life is greatly deteriorated. Diamond-like carbon (DLC) is one of the promising candidates to improve the performance and life of cutting tool due to their low frictional property. In this study, a sacrificial DLC layer is applied on the hard nitride coated drill tool to improve the durability. The DLC coatings are fabricated by controlling the acceleration voltage of the linear ion source in the range of 0.6~1.8 kV. As a result, the optimized hardness(20 GPa) and wear resistance(1.4 x 10-8 ㎣/N·m) were obtained at the 1.4 kV. Then, the optimized DLC coating is applied as an sacrificial layer on the hard nitride coating to evaluate the performance and life of cutting tool. The Vickers hardness of the composite coatings were similar to those of the nitride coatings (AlCrN, AlTiSiN), but the friction coefficients were significantly reduced to 0.13 compared to 0.63 of nitride coatings. The drilling test were performed on S55C plate using a drilling machine at rotation speed of 2,500 rpm and penetration rate of 0.25 m/rev. The result showed that the wear width of the composite coated drills were 200 % lower than those of the AlCrN, AlTiSiN coated drills. In addition, the cutting forces of the composite coated drills were 13 and 15 % lower than that of AlCrN, AlTiSiN coated drills, respectively, as it reduced the aluminum clogging. Finally, the application of the DLC sacrificial layer prevents initial chipping through its low friction property and improves drilling quality with efficient chip removal.

Development of Physical Fitness Standard Indicators According to the Bone Age in Youth (유소년의 골연령에 따른 체력 표준지표 개발)

  • Kim, Dae-Hoon;Yoon, Hyoung-ki;Oh, Sei-Yi;Lee, Young-Jun;Cho, Seok-Yeon;Song, Dae-Sik;Seo, Dong-Nyeuck;Kim, Ju-Won;Na, Gyu-Min;Kim, Min-Jun;Oh, Kyung-A
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1627-1642
    • /
    • 2021
  • This study aims to evaluate physical fitness according to the bone age of youth, and ultimately provide basic data for balanced development of youth through physical fitness standard indicators according to the bone age. A total of 730 youth aged 11 to 13 years in bone age and 11 to 13 years in chronological age were selected as subjects; and after taking X-ray films to calculate the bone age, they were evaluated by using the TW3 method. A total of 2 components in physique, which were stature and weight, were measured using a stadiometer(Hanebio, Korea, 2021) and Inbody 270(Biospace, Korea, 2019). A total of 7 components in physical fitness were measured as well, which included muscular strength (Hand Grip Strength), balance (Bass Stick Test), agility (Plate Tapping), power (Standing Long Jump), flexibility (Sit&Reach), muscular endurance (Sit-Up), and cardiovascular endurance (Shuttle Run). Descriptive statistics and independent t-test were conducted for data processing using the SPSS PC/Program(Version 26.0), and it was considered significant at the level of p< .05. The results of this study may be summarized as follow. First, the result of comparing the bone age and the chronological age of 11 to 13 years old in physical fitness, males showed significant difference in muscular strength, power, muscular endurance, and cardiovasular endurance. In females, muscular strength, balance, agility, power, flexibility, muscular endurance, and cardiovascular endurance showed significant difference. Second, physical fitness standard indicators were presented for each gender and age (11-13 years old) of youth according to the bone age; and based on this, physical fitness standard indicators, which are basic data for physical fitness evaluation according to the bone age of youth, were presented.

A Two-Stage Learning Method of CNN and K-means RGB Cluster for Sentiment Classification of Images (이미지 감성분류를 위한 CNN과 K-means RGB Cluster 이-단계 학습 방안)

  • Kim, Jeongtae;Park, Eunbi;Han, Kiwoong;Lee, Junghyun;Lee, Hong Joo
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.3
    • /
    • pp.139-156
    • /
    • 2021
  • The biggest reason for using a deep learning model in image classification is that it is possible to consider the relationship between each region by extracting each region's features from the overall information of the image. However, the CNN model may not be suitable for emotional image data without the image's regional features. To solve the difficulty of classifying emotion images, many researchers each year propose a CNN-based architecture suitable for emotion images. Studies on the relationship between color and human emotion were also conducted, and results were derived that different emotions are induced according to color. In studies using deep learning, there have been studies that apply color information to image subtraction classification. The case where the image's color information is additionally used than the case where the classification model is trained with only the image improves the accuracy of classifying image emotions. This study proposes two ways to increase the accuracy by incorporating the result value after the model classifies an image's emotion. Both methods improve accuracy by modifying the result value based on statistics using the color of the picture. When performing the test by finding the two-color combinations most distributed for all training data, the two-color combinations most distributed for each test data image were found. The result values were corrected according to the color combination distribution. This method weights the result value obtained after the model classifies an image's emotion by creating an expression based on the log function and the exponential function. Emotion6, classified into six emotions, and Artphoto classified into eight categories were used for the image data. Densenet169, Mnasnet, Resnet101, Resnet152, and Vgg19 architectures were used for the CNN model, and the performance evaluation was compared before and after applying the two-stage learning to the CNN model. Inspired by color psychology, which deals with the relationship between colors and emotions, when creating a model that classifies an image's sentiment, we studied how to improve accuracy by modifying the result values based on color. Sixteen colors were used: red, orange, yellow, green, blue, indigo, purple, turquoise, pink, magenta, brown, gray, silver, gold, white, and black. It has meaning. Using Scikit-learn's Clustering, the seven colors that are primarily distributed in the image are checked. Then, the RGB coordinate values of the colors from the image are compared with the RGB coordinate values of the 16 colors presented in the above data. That is, it was converted to the closest color. Suppose three or more color combinations are selected. In that case, too many color combinations occur, resulting in a problem in which the distribution is scattered, so a situation fewer influences the result value. Therefore, to solve this problem, two-color combinations were found and weighted to the model. Before training, the most distributed color combinations were found for all training data images. The distribution of color combinations for each class was stored in a Python dictionary format to be used during testing. During the test, the two-color combinations that are most distributed for each test data image are found. After that, we checked how the color combinations were distributed in the training data and corrected the result. We devised several equations to weight the result value from the model based on the extracted color as described above. The data set was randomly divided by 80:20, and the model was verified using 20% of the data as a test set. After splitting the remaining 80% of the data into five divisions to perform 5-fold cross-validation, the model was trained five times using different verification datasets. Finally, the performance was checked using the test dataset that was previously separated. Adam was used as the activation function, and the learning rate was set to 0.01. The training was performed as much as 20 epochs, and if the validation loss value did not decrease during five epochs of learning, the experiment was stopped. Early tapping was set to load the model with the best validation loss value. The classification accuracy was better when the extracted information using color properties was used together than the case using only the CNN architecture.

A Clustering of Physical Fitness according to the Skeletal Maturation of Elementary School Students : Focused on Cluster Analysis (초등학생의 골성숙도에 따른 체력 군집화 : 군집분석 중심으로)

  • Kim, Dae-Hoon;Yoon, Hyoung-ki;Oh, Sei-Yi;Lee, Young-Jun;Cho, Seok-Yeon;Song, Dae-Sik;Seo, Dong-Nyeuck;Kim, Ju-Won;Na, Gyu-Min;Kim, Min-Jun;Oh, ․Kyung-A
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.63-73
    • /
    • 2022
  • The aim of this study was to cluster according to the bone age of elementary school students in order to analyze the physique, physical fitness, and skeletal maturation of each cluter group and to provide basic data for the balanced development of elementary school students through data analysis. The subjects of this study were 2243 students aged 8 to 13 years, and the skeletal maturation were calculated by applying them to the TW3 method score conversion table after the X-ray films were taken. A total of 2 components in physique were measured using a stadiometer(Hanebio, Korea, 2021) and the Inbody 270(Biospace, Korea, 2019), and a total of 7 components in physical fitness, which included muscular strength(Hand Grip Strength), balance(Bass Stick Test), agility(Plate Tapping), power(Standing Long Jump), flexibility(Sit&Reach), muscular endurance(Sit-Up), and cardiovascular endurance(Shuttle Run) were measured as well. K-Means clustering method, cross-tabulation analysis, and one-way variable analysis(ANOVA) were conducted for data processing using the SPSS PC/Program(Version 26.0) and Bristics Studio Tool, and it was considered significant at the level of p< .05. The results of this study may be summarized as follow. First, as a result of clustering using three components of skeletal maturation: retarded, normal, and advanced, cluster 1(Retarded) showed excellence in muscular strength, balance, and agility. cluster 2(Normal) showed poor flexibility, whereas cluster 3(Advanced) showed excellence in muscular strength. Second, as a result of analyzing the differences in physique according to the clustering of elementary school students by their individual characteristics, cluster 3(Advanced) showed excellence in height, weight, and body fat percentage. Third, as a result of analyzing the differences in physical fitness according to the clustering of elementary school students by their individual characteristics, cluster 3(Advanced) showed excellence in Hand Grip Strength(Left, Right), whereas cluster 1(Retarded) showed excellence in Bass Stick Test, and cluster 3(Advanced) showed excellence in Standing Long Jump.

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.