• Title/Summary/Keyword: Tapping test

Search Result 77, Processing Time 0.038 seconds

ACF/IACF and Zwicker Parameters Analysis on Floor Impact Noise (표준바닥충격원의 ACF/IACF 및 Zwicker 파라메타 분석)

  • ;;Yoichi Ando
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.945-950
    • /
    • 2001
  • Floor impact noise has been evaluated by investigating the temporal and spectral characteristics of the noise. The noises generated by different impactors were analyzed to find out whether there is any correlation with the factors of ACF /IACF (Autocorrelation Function/Inter-aural Cross-correlation Function) [1] and Zwicker parameters [2]. Experiments were undertaken to compare the objective and subjective parameters of the floor impact noises generated by a bang/tapping machine, a rubber ball [3], and a walker. As a result, it was found that $\phi$ (0) and IACC extracted from ACF/IACF, and Loudness, Unbiased Annoyance from Zwicker parameters showed high correlation with subjective evaluations of loudness concerning floor impact noises. In addition, it was revealed that jumping is similar to the ball.

  • PDF

Development of a Separable Glued-Laminated Timber (GLT)-Steel Beam for Eco-Friendly Construction and Dismantling of Buildings (건축물의 친환경 시공·해체를 위한 재료 분리형 GLT-Steel 보 개발)

  • Pang, Sung-Jun;Oh, Jung-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.23-24
    • /
    • 2023
  • In this study, an easily recyclable separable glued-laminated timber (GLT)-steel beam was developed, and a structural design method was presented. The GLT and steel were mechanically composited using self-tapping screws. The GLT-steel beam was designed to fail in the compression of GLT. The bending moment and load-carrying capacity of the GLT-steel beam were predicted based on composite beam theory and compared with experimental test data. As a result, the GLT-steel beam exhibited ductile behavior, and compression failure of GLT was observed. The screw connection showed no damage while the steel plate was extended. The load-carrying capacity of GLT after failure was similar to the load resistance predicted by the compressive strength of GLT and the tensile strength of steel. This indicates that the ductile behavior of the GLT-steel beam can be safely designed by the tensile strength (yield) of steel.

  • PDF

Neurocognitive Deficits in Patients with Schizophrenia and Unaffected First-Degree Relatives (조현병 환자와 발병하지 않은 일차친족에서 신경인지의 결함)

  • Kim, DoHoon;Kim, Jiwoo;Hwang, Sunyoung;Kim, Byungsoo;Won, Seunghee
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.2
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives This study aimed to identify the differences and the profiles of cognitive deficits in remitted patients with schizophrenia and first-degree relatives of schizophrenic probands. Methods A total of 26 remitted states of schizophrenia patients were included in the study and the same number of unaffected first-degree relatives of schizophrenic probands and healthy controls were matched for age, sex, years of education. Cognitive function of all participants was measured by using the Digit span test, the Continuous performance test, the Rey auditory & visual learning test, the Complex figure test, the Verbal fluency test, the Wisconsin card sorting test and the Finger tapping test. The effects of subsyndromal symptomatology and general intelligence score were controlled. Results Schizophrenia patients' group showed more significant impairment than other groups in verbal memory (learning, immediate recall, delayed recall), visual memory (copy, immediate recall, delayed recall) and cognitive flexibility domains. The family group and the patient group commonly performed significantly worse than healthy controls in working memory and verbal fluency (category) tests. There were no differences in sustained attention, psychomotor performance. Conclusions Our research shows that the deficit in working memory and verbal fluency could be strong candidates of endophenotypic marker in schizophrenia.

Inter-Rater Reliability of Quantitative Knee Tendon Reflex Test for Healthy Subjects (정상 성인에 대한 정량적 무릎힘줄반사 검사의 측정자간 신뢰도)

  • Kim, Yong-Wook;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.57-63
    • /
    • 2007
  • The purpose of this study was to evaluate inter-rater reliability of the amplitude and first knee extension angles in deep tendon reflex test by using an electrical hammer. Twenty-five healthy adults participated in the study. Compound muscle action potential is elicited by tapping the knee tendon with an electrical hammer in deep tendon reflex tests. The amplitude and knee extension angle were simultaneously measured. The mean value of the amplitude and the knee extension angles through three time trials for each tester, are used for determining the inter-rater and Intra-class Correlation Coefficients (ICCs) reliabilities. According to the results, the ICCs of the amplitude is .280 and that of the knee extension angle is .789. Pearson correlation coefficients of the amplitude of the action potential and the knee extension angles are .685, showing significant statistically moderate correlation. Inter-rater reliability in the amplitude was not significant. More objective and quantitative deep tendon reflex tests should be done to obtain higher reliability in further studies.

  • PDF

Design and Implementation of a Mobile-based Sarcopenia Prediction and Monitoring System (모바일 기반의 '근감소증' 예측 및 모니터링 시스템 설계 및 구현)

  • Kang, Hyeonmin;Park, Chaieun;Ju, Minina;Seo, Seokkyo;Jeon, Justin Y.;Kim, Jinwoo
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.3
    • /
    • pp.510-518
    • /
    • 2022
  • This paper confirmed the technical reliability of mobile-based sarcopenia prediction and monitoring system. In implementing the developed system, we designed using only sensors built into a smartphone without a separate external device. The prediction system predicts the possibility of sarcopenia without visiting a hospital by performing the SARC-F survey, the 5-time chair stand test, and the rapid tapping test. The Monitoring system tracks and analyzes the average walking speed in daily life to quickly detect the risk of sarcopenia. Through this, it is possible to rapid detection of undiagnosed risk of undiagnosed sarcopenia and initiate appropriate medical treatment. Through prediction and monitoring system, the user may predict and manage sarcopenia, and the developed system can have a positive effect on reducing medical demand and reducing medical costs. In addition, collected data is useful for the patient-doctor communication. Furthermore, the collected data can be used for learning data of artificial intelligence, contributing to medical artificial intelligence and e-health industry.

Effects of Teratainment Taping and Footpad Exercise on the Improvement of Flat Foot in a University Student (테라테인먼트 테이핑과 발바닥 운동이 대학생의 평발 개선에 미치는 영향)

  • Lee, Jeong-Uk;Yoon, Young-Jeoi;Ko, Sun-Kun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.4
    • /
    • pp.369-375
    • /
    • 2019
  • This study looked at the effects of teratainment taping and footpad exercise on the improvement of flat foot in a university student. We divided it into flexible flat foot taping group(n=13), flexible flat foot exercise group(n=14), rigid flat foot taping group(n=12), rigid flat foot exercise group(n=13) through a navicular drop test. After one hour's application of teratainment taping and footpad exercise, the height change of navicular, balancing ability and postural stability were evaluated. Change in the height of the navicular was measured before and after intervention, and the balancing ability was measured timed up & go test, and the postural stability ability was evaluated for stability limits in shoulder-width double leg stance, narrow base double leg stance, tandem stance. According to result, there was a statistically significant difference in the left and right foot of the flexible tapping group, right foot of the flexible tapping group, right foot of the rigid tapping group in the change in the height of the navicular in comparison pre- and post- intervention(p<0.5). There were no statistically significant differences in pre- and post- intervention comparisons intragroup and intergroup in balancing ability. There was a statistically significant difference in flexible flat foot exercise group and rigid flat foot taping group in tandem stance in comparison pre- and postintervention in the postural stability(p<0.5). And there was a statistically significant difference in tendem stance of the flexible flat foot exercise group compared to the rigid flat foot exercise group(p<0.5). The results of this study show that teratainment taping and footpad exercise have a significant effect on the improvement of flat foot in adults. Therefore, it is recommended to apply teratainment taping and footpad exercise to improve flat foot.

A Case Report of a Patient with Motor Disturbance of the Hand After Cerebral Infarction Treated with Electroacupuncture on Pal-sa (EX-UE9) (뇌경색 후 수부 미세운동 장애에 팔사혈(八邪穴)(EX-UE9) 전침을 적용한 호전 증례보고)

  • Kim, Jae-hak;Jung, Min-ho;Kim, Se-won;Cho, Ki-ho;Jung, Woo-sang;Kwon, Seung-won;Mun, Sang-kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.2
    • /
    • pp.147-153
    • /
    • 2018
  • Objective: The purpose of this case report is to evaluate the effect of electroacupuncture on Pal-sa (EX-UE9) for unilateral motor disturbance of the hand after cerebral infarction. Methods: One patient with unilateral motor disturbance of the hand following cerebral infarction (right basal ganglion and corona radiata) was treated with acupuncture, herbal medication, and electroacupuncture on Pal-sa (EX-UE9) once daily from June 30, 2016 to July 4, 2016. We evaluated improvement using the Box and Block Test (BTT) and 10-seconds Test, including the Finger Individual Movement Test (FIMT), the Hand Pronation and Supination Test (HPST), and the Finger Tapping Test (FTT). Results: After five days of treatment, increase of FIMT and FTT scores was observed after electroacupuncture on Pal-sa (EX-UE9). However, no increase was observed in BBT or HPST scores. Conclusions: This study suggests that electroacupuncture on Pal-sa (EX-UE9) can help treat motor disturbance of the hand after cerebral infarction.

Effect of Treadmill Training and Proprioceptive Neuromuscular Facilitation Lower Leg Taping on Balance and Gait Ability in Stroke Patients (고유수용성신경근촉진법 아래다리 테이핑적용과 트레드밀 훈련이 뇌졸중 환자의 보행능력과 균형능력에 미치는 영향)

  • Jeong, Wang-Mo;Kim, Beom-Ryong;Kang, Mi-Gyeong
    • PNF and Movement
    • /
    • v.14 no.2
    • /
    • pp.83-91
    • /
    • 2016
  • Purpose: The purpose of this study was both to examine the effects of proprioceptive neuromuscular facilitation (PNF) lower leg taping and treadmill training on the gait and balance abilities of patients with hemiplegia resulting from a stroke and to provide a taping method based on the PNF concept. Methods: Twenty patients with hemiplegia resulting from a stroke were randomly and equally assigned to a control group (n=10), which received treadmill training, and to an experimental group (n=10), which received PNF lower leg taping and treadmill training. The intervention was conducted five times per week for six weeks. In order to measure changes in the gait ability of the subjects, a 10-meter walking test (10MWT) and a 6-minute walking test (6MWT) were conducted, and in order to measure changes in the subjects' balance ability, a timed up and go test (TUG) was performed. In order to compare differences within each group before and after the intervention, a paired-t test was carried out, and in order to compare differences between the two groups, the analysis of covariance was utilized. All statistical significance levels were set at ${\alpha}=0.05$. Results: There were significant differences before and after the intervention within both groups in changes of 10MWT, 6MWT, and TUG (p<0.01). Regarding differences between the two groups, the experimental group underwent more effective changes than the control group in 6MWT and TUG (p<0.05). Conclusion: This study applied PNF lower leg taping and treadmill training to patients with hemiplegia resulting from a stroke, and this resulted in improvement in the subjects' gait and balance abilities. Taping and treadmill training based on the PNF concept is considered to be usefully applied as one of the programs to improve hemiplegic patients' gait and balance abilities.

Folate nutrition is related to neuropsychological functions in the elderly

  • Chang, Nam-Soo;Kim, Eun-Jung;Kim, Ki-Nam;Kim, Hye-Sook;Kim, Seong-Yoon;Jeong, Bum-Seok
    • Nutrition Research and Practice
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • We investigated the nutritional state of B vitamins and the neuropsychological functions in 25 subjects, aged $63.1{\pm}6.3$ years, residing in rural areas of Korea. Nutritional states of thiamin, riboflavin, and pyridoxine were assessed enzymatically in the erythrocytes, and folate concentrations were measured microbiologically in the plasma and erythrocytes. A battery of composite neuropsychological test was administered to the subjects. Plasma folate was correlated with the total intelligence score (p=0.049). Folate levels in the erythrocytes were correlated with the performance intelligence scores such as block design (p=0.017) and picture arrangement (p=0.016). The red cell folate was correlated with memory scores such as general memory (p=0.009) and delayed recall (p=0.000). Although it did not reach statistical significance, verbal memory (p=0.053) was highly correlated with the red cell folate. The red cell folate was also correlated positively with the percent of conceptual level response number score (p=0.029), and negatively with the grooved pegboard test score for the non-dominant hand (p=0.010). Fine motor coordination was also influenced by folate nutrition, as finger tapping scores in both hands were significantly correlated with red cell folate (dominant hand; p=0.026, non-dominant hand; p=0.004). Other B vitamins such as thiamin, riboflavin, and vitamin $B_6$ were not as strongly correlated with neuropsychological function test scores as folate was. These results suggest that folate nutrition influences neuropsychological function test scores significantly in humans. Further studies are needed to explore the relationship between folate or other vitamin B nutrition and neuropsychological functions and the implications thereof.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).