• Title/Summary/Keyword: Tapered ratio

Search Result 133, Processing Time 0.027 seconds

Deflection and bending characteristics of embedded functionally graded porous plate with bi-directional thickness variation subjected to bi-sinusoidal loading

  • Rajat Jain;Mohammad Sikandar Azam
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.601-617
    • /
    • 2024
  • This work aims to explore the static behaviour of a tapered functionally graded porous plate (FGPP) with even and uneven porosity distributions resting on two parametric elastic foundations. The plate under investigation is subjected to bi-sinusoidal loading and the edges of the plate are exposed to different combinations of edge restrictions. In order to examin the static behaviour, bending factors (BF) related to bending and normal stresses have been evaluated using classical plate theory. To achieve this, the governing equations have been derived employing the energy concept. And to solve it, the Rayleigh-Ritz method with an algebraic function has been utilised; it is simple, precise, and computationally intensive. After convergence and validation analyses, new findings are made available. The BF of the plate have been exhaustively examined to explain the influence of aspect ratios, material property index, porosity factor, taper factor, and Winkler and Pasternak stiffness. It is observed that the BF of an elastically supported FGPP are influenced by the index of material propery and the aspect ratio. Findings also indicate that the impact of porosity is more when it is spread evenly, as opposed to when it is unevenly distributed. Further, the deformed plate's structure is significantly influenced by the different thickness variations. Examination of bending characteristics of FGPP having different new cases of thickness variations with different types of porosity distribution under fifteen different mixed edge constraints is the prime novality of this work. Results presented are reliable enough to be taken into account for future studies.

A Study on Taper Etching of Polysilicon-Part I : The Experimental Study (다결정실리콘의 경사식각에 관한 연구 - 제 1 부 : 실험적 고찰)

  • Lee, Jung-Kyu;Suh, Dong-Ryang;Byun, Jae-Dong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.50-57
    • /
    • 1989
  • Tapered etching of polysilicon films has been achieved by implanting phosphorus ions into the polysilicon film and using plasma etch in either $CF_4-O_2\;or\;SF_6$. A two-step plasma etching method is also proposed to control the taper angle of the etched edge without changing the implantion conditions. The taper angle is determined by the ratio of the etch rate of the undamaged region to that of the damaged top region of the polysilicon layer. The ratio is found to be dependent on the implantion dose, the implantion energy and the anisotropy of etching. The minimum angle in our experiments is about $10^{\circ}$. When the two-step etching method is employed, the taper angles can be controlled from the minimum angle up to about $55^{\circ}$.

  • PDF

Numerical Study on the Optimal Shape of Concrete Plug for Compressed Air Energy Storage Caverns (압축공기에너지 저장 공동의 콘크리트 플러그 최적 형상에 대한 수치해석적 연구)

  • Park, Doh-Hun;Kim, Hyung-Mok;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.3
    • /
    • pp.164-173
    • /
    • 2011
  • In the present study, the stability of a compressed air energy storage cavern was numerically assessed by concrete plug shapes in order to investigate the optimal shape of concrete plug. The concrete plugs were cylindrical, embedded cylindrical, tapered, and wedged in shape. The stability assessment was carried out based on factor of safety through a strength reduction method and a volume ratio which refers to the ratio of the volume of yield regions in concrete induced by internal pressure to all concrete volume. The results from the present study indicated that the embedded cylindrical and taper shaped plugs were mechanically more stable than the cylindrical and wedge shaped plugs. However, from a comparison of stress distributions in rock mass between the embedded cylindrical and taper shaped plugs, the taper shaped plug was found to be more optimal than the embedded cylindrical plug, since the embedded cylindrical plug caused more stress concentration in the interface between the plug and rock mass than the taper shaped plug.

The Effect of Paroxetine on Symptom Improvement and Change of Heart Rate Variability of the Patients with Panic Disorder (Paroxetine이 공황장애 환자의 증상 개선과 HRV 양상 변화에 미치는 영향)

  • Ahn, Joo-Yeun;Yu, Bum-Hee
    • Anxiety and mood
    • /
    • v.2 no.2
    • /
    • pp.101-107
    • /
    • 2006
  • Object : Since autonomic nerve system dysfunction was known as the mechanism of panic disorder, many researchers used heart rate variability (HRV) as means of measuring autonomic nerve function of patients with panic disorder. We aimed to examine the effect of paroxetine medication for 3 months on symptom improvement and change of heart rate variability of the patients with panic disorder. Methods : The subjects were patients with panic disorder who visited the psychiatric outpatient clinic of Samsung Medical Center in Seoul. We included panic disorder patients who were aged from 20 to 50 and in normal BMI range (from 18 to 30) to minimize the effect of age and weight on HRV data. We excluded the patients with EKG abnormalities, hypertension or other major psychiatric disorders. They took 20-40 mg paroxetine medication a day for 3 months. Alprazolam was used only during the first month to control the acute panic symptoms and was tapered off after that. We measured the acute panic inventory (API), Hamilton rating scale for anxiety and depression (HAM-A & HAM-D), Spielberger state-trait anxiety inventory (STAIS, STAIT), and Beck depression inventory (BDI) in order to assess clinical improvement of the patients. And we measured time and frequency domain HRV in the resting, standing and cognitive stress states to assess the change of HRV. All measurements were done before and after paroxetine treatment. Result : After paroxetine medication, patients showed significant improvement in all psychiatric scales. In time domain of HRV, standard deviations of all R-R intervals (SDNN) were significantly increased in all states. In frequency domain of HRV, the ratio of high frequency to total power (HF/TP) in the standing state was significantly increased. Conclusion : After 3 months paroxetine medication, panic disorder patients showed significant clinical improvement and change in HRV data such as SDNN in all states and HF/TP ratio in the standing state. This result suggests that paroxetine medication is effective for the improvement of autonomic nerve system dysfunction in panic disorder patients.

  • PDF

The Eigenvalues and Their Relationships for the Rectangular Frame (4각형 골조의 고유치와 고유치 간의 관계)

  • Lee, Soo-Gon;Kim, Soon-Cheol;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.139-150
    • /
    • 2005
  • Finite element method is applied to the determinations of the two eigenvalues(the elastic critical load and the natural frequence of lateral vibrations) of single story-3 equal bay rectangular frame. The analysis parameters are taper parameter ${\alpha}$ for column, and beam span to column height ratio, ${\beta}$ and second moment area ratio of beam to column, ${\Upsilon}$. Support condition at the column base and sway condition at the column top are also considered in the stability analysis of frame. The changes in the coefficient of eigenvalue are represented by algebraic function of analysis parameter. The coefficients estimated by the proposed algebraic function show good agreement with those determined by finite element method, which suggest the design aid role of the proposed function. By increasing the column axial forces step by step, the corresponding frequencies are also determined, which makes one examine or confirm the relationship suggested by other studies.

Characteristics Variation Analysis by Shape of Piezoelectric Ultrasonic Transducer with Non-Uniform Thickness (두께 불균일 압전 초음파 트랜스듀서의 형태에 따른 특성변화 해석)

  • Kim, Dong-Hyun;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.271-278
    • /
    • 2008
  • The electro-mechanical characteristics were theoretically analyzed for the wideband ultrasonic transducer made of non-uniform thickness piezoelectric vibrator. This paper proposes a combination of exponential functions which describes the thickness variation along the length of the vibrator to derive the input admittance and power transfer function of the transducer. The bandwidth and the power transfer function of the transducer were investigated while the lateral shape of the vibrator changes. The results showed there is an optimum shape for the wideband characteristics of the transducer, and the bandwidth has increased up to over 100% as the ratio of minimum value of thickness to maximum value decreases. However, the power transfer function had a downward trend as the ratio of thickness decreases. Also we confirmed that even though the value of transfer function increases as the length of the piezoelectric vibrator increases, the shape providing wideband characteristics is very limited. It means that precision processing is required to manufacturing a wideband ultrasonic transducer with high efficiency.

An Structural Design for Cyclone Tower's Connections Using Diagrid System (다이아그리드 구조시스템의 접합부개발과 성능평가)

  • Lee, Se-Jung;Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • Recently, High-rise building are irregular-shaped to be city landmarks and function as vertical cities to enable the efficient use of land. 3T (Twisted, Tilted & Tapered) designs are being suggested for irregular buildings and studies to develop new structural system have been actively made to satisfy slender shape ratio. In diagrid system, not only gravity load but also lateral load is delivered based on the triangular shape of diagrid, so most of columns are eliminated. Because shearing force is delivered by the axial behavior (tensile/compressive) of diagrid to minimize shearing deformation, the system is more applicable to irregular buildings than existing system where shearing force is delivered by the columns. In this study, the process of selecting connection details and the structural safety of the selected details are verified using the finite element analysis with focus given to the construction overview of the Cyclone Tower. However, the relersed methods of stress concentration are suggested and the performance of stress concentration relieves that it's suggested for the appropriate cap plate thickness and extended length.

  • PDF

Cu dry etching by the reaction of Cu oxide with H(hfac) (Cu oxide의 형성과 H(hfac) 반응을 이용한 Cu 박막의 건식식각)

  • Yang, Hui-Jeong;Hong, Seong-Jin;Jo, Beom-Seok;Lee, Won-Hui;Lee, Jae-Gap
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.527-532
    • /
    • 2001
  • Dry etching of copper film using $O_2$ plasma and H(hfac) has been investigated. A one-step process consisting of copper film oxidation with an $O_2$ plasma and the removal of surface copper oxide by the reaction with H(hfac) to form volatile Cu(hfac)$_2$ and $H_2O$ was carried but. The etching rate of Cu in the range from 50 to 700 /min was obtained depending on the substrate temperature, the H(hfac)/O$_2$ flow rate ratio, and the plasma power. The copper film etch rate increased with increasing RF power at the temperatures higher than 215$^{\circ}C$. The optimum H(hfac)/O$_2$ flow rate ratio was 1:1, suggesting that the oxidation process and the reaction with H(hfac) should be in balance. Cu patterning using a Ti mask was performed at a flow rate ratio of 1:1 on 25$0^{\circ}C$\ulcorner and an isotropic etching profile with a taper slope of 30$^{\circ}$was obtained. Cu dry patterning with a tapered angle which is necessary for the advanced high resolution large area thin film transistor liquid-crystal displays was thus successfully obtained from one step process by manipulating the substrate temperature, RF power, and flow rate ratio.

  • PDF

THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS (수종의 근관형성 방법이 근관 형태에 미치는 영향)

  • Lee, Ji-Hyeon;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

Fabrication of Microwire Arrays for Enhanced Light Trapping Efficiency Using Deep Reactive Ion Etching

  • Hwang, In-Chan;Seo, Gwan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.454-454
    • /
    • 2014
  • Silicon microwire array is one of the promising platforms as a means for developing highly efficient solar cells thanks to the enhanced light trapping efficiency. Among the various fabrication methods of microstructures, deep reactive ion etching (DRIE) process has been extensively used in fabrication of high aspect ratio microwire arrays. In this presentation, we show precisely controlled Si microwire arrays by tuning the DRIE process conditions. A periodic microdisk arrays were patterned on 4-inch Si wafer (p-type, $1{\sim}10{\Omega}cm$) using photolithography. After developing the pattern, 150-nm-thick Al was deposited and lifted-off to leave Al microdisk arrays on the starting Si wafer. Periodic Al microdisk arrays (diameter of $2{\mu}m$ and periodic distance of $2{\mu}m$) were used as an etch mask. A DRIE process (Tegal 200) is used for anisotropic deep silicon etching at room temperature. During the process, $SF_6$ and $C_4F_8$ gases were used for the etching and surface passivation, respectively. The length and shape of microwire arrays were controlled by etching time and $SF_6/C_4F_8$ ratio. By adjusting $SF_6/C_4F_8$ gas ratio, the shape of Si microwire can be controlled, resulting in the formation of tapered or vertical microwires. After DRIE process, the residual polymer and etching damage on the surface of the microwires were removed using piranha solution ($H_2SO_4:H_2O_2=4:1$) followed by thermal oxidation ($900^{\circ}C$, 40 min). The oxide layer formed through the thermal oxidation was etched by diluted hydrofluoric acid (1 wt% HF). The surface morphology of a Si microwire arrays was characterized by field-emission scanning electron microscopy (FE-SEM, Hitachi S-4800). Optical reflection measurements were performed over 300~1100 nm wavelengths using a UV-Vis/NIR spectrophotometer (Cary 5000, Agilent) in which a 60 mm integrating sphere (Labsphere) is equipped to account for total light (diffuse and specular) reflected from the samples. The total reflection by the microwire arrays sample was reduced from 20 % to 10 % of the incident light over the visible region when the length of the microwire was increased from $10{\mu}m$ to $30{\mu}m$.

  • PDF