• 제목/요약/키워드: Taper shape

검색결과 111건 처리시간 0.023초

방전 가공을 이용한 미세 구멍 가공 시 발생하는 테이퍼 형상의 제어 (Control of Taper Shape in Micro-Hole Machining by Micro-EDM)

  • 김동준;이상민;이영수;주종남
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.52-59
    • /
    • 2005
  • When a micro hole is machined by EDM with a cylindrical electrode, the hole diameter is different at the inlet and the outlet of the micro hole. The taper shape of the micro hole is caused by not only wear of the electrode but the eroded particles. The eroded particles cause secondary discharge during machining the micro hole. As a result, the diameter of the inlet becomes larger than that of the outlet. In this paper, a new method is proposed to reduce the difference in diameter between the inlet and the outlet of the hole. Observed was that the feed depth and machining time affect the formation of taper shape On this experimental basis, ultrasonic vibration was applied to reduce machining time, and capacitance was changed during machining to use the difference in discharging energy of different capacitances. Using the proposed method, a straight micro-hole was fabricated.

일부 전류분류 영역을 갖는 테이퍼 형상 전류도입선의 최적 형상에 대한 연구 (The Optimum Shape of Taper HTS Current Lead Having Partial Current Sharing Region)

  • 허광수;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.185-189
    • /
    • 2003
  • The purpose of this study is to obtain the optimal operating condition of conduction cooled taper shape high-temperature superconductor (HTS) current lead operated in current sharing mode. In our previous study, we discovered that the optimal operating condition of constant cross-section area HTS current lead is in the current sharing state, and in optimal condition, the temperature gradient at warm end is not zero. The analysis result of taper HTS current lead is quiet similar to the constant area HTS current lead. The minimum dissipation of taper HTS current lead is not influenced by taper angle, however the optimal operation condition is varied with taper angle.

  • PDF

레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구 (A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS)

  • 양인석;강인철;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권5호
    • /
    • pp.393-401
    • /
    • 2005
  • 본 연구는 형태 및 재질이 동일한 엔진구동형 ProTaper파일과 수동형 ProTaper파일을 이용하여 레진모형근관을 성형한 후 근관형태 변화를 비교 분석하고자 시행되었다. 본 연구에서는 레진모형근관으로 총 40개의 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다. 근관 성형 기구로는 엔진구동형 Ni-Ti 파일로 $ProTaper^{TM}$, 수동형 Ni-Ti 파일로 $ProTaper^{(R)}$ For Hand Use를 사용하였다. 사용된 레진모형근관과 파일의 종류에 따라 10개씩 4개의 그룹으로 나누어 근관성형을 시행하였다. 근관 성형 전$\cdot$후 이미지를 스캐너 (Color scanner, UMAX Technologies, Inc., USA)를 이용하여 얻은 후. Photoshop 7.0 프로그램 (Adobe System Inc., USA)을 이용하여 이미지를 중첩하였다. 이미지 분석 프로그램 (Image-$Pro^{(R)}$ Plus, Media Cybernetic, USA)을 이용하여 치근단 쪽에서부터 0, 1, 2, 3, 4, 5, 6 및 7 mm 수준에서 근관 성형에 따른 근관의 내측 및 외측 폭경의 변화량, 근관 총폭경의 변화량, 근관 중심축의 변위량을 측정하였다. 또한 근관 성형 시간을 기록하였다. 두 기구 사이의 유의성 검정을 위해 독립 표본 t-검정을 시행하여, 근관 성형 시 수동형 ProTaper 파일이 엔진구동형 ProTaper 파일에 비해 근관 중심축의 변위가 유의하게 덜 일어나며 근관의 원래 형태를 더욱 잘 유지할 수 있지만, 근관 성형시간은 길어질 수 있다는 결론을 얻었다.

ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구 (A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE)

  • 이보금;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권4호
    • /
    • pp.294-302
    • /
    • 2005
  • 본 연구는 ProFile, ProTaper 및 K-Flexofile로 근관 성형시 근관의 만곡도에 따라 근관의 형태가 어떻게 변화하는지를 비교 분석하고자 시행되었다. ISO #15 finger spreader를 15도, 30도 및 45도로 만곡시키고 에폭시 레진으로 각각도의 근관을 갖는 30개의 근관 모형을 제작하였다. 근관의 길이는 18mm로 하였고 근관의 만곡은 근관의 입구로부터 10mm 부위에서 시작하도록 제작하였다. 근관 성형에는 엔진 구동형 니켈-타이타늄 파일인 ProFile과 ProTaper, 수동형 stainless steel 파일인 K-Flexofile을 사용하였다. ProFile과 ProTaper는 제조자의 지시에 따라 크라운다운법으로 근관 성형하였고, K-Flexofile은 스텝백법으로 근관 성형하였다. 근첨부 성형은 #25파일 크기까지 시행하였다. 근관 성형 전 후 이미지를 스캐너를 이용하여 얻고 Photoshop 7.0프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 치근단 쪽에서부터 1, 2, 3, 4, 5, 6, 7, 8, 9및 10mm부위의 내 외측 폭경 변화와 총폭경 및 근관의 중심축에 대한 근관 변위을 측정하였다. 각 부위에서 내 외측 폭경과 총폭경 및 근관 변위의 유의성 검정을 위해 one-way ANOVA분석을 시행하였으며 각 기구간의 유의성 검정은 Scheffe's test로 사후 분석하였다. 또한 기구의 변형과 파절 여부를 평가한 결과 엔진 구동형 니켈-타이타늄 파일인 ProFile과 ProTaper를 사용하여 근관성형시 수동형 스테인레스 스틸 파일인 K-Flexofile에 비해 근관의 변위를 적게 유발하고 특히 ProFile이 근관 성형시 바람직한 기구임을 시사하였다.

Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study

  • Emmanuel Joao Nogueira Leal da Silva;Sara Gomes de Moura;Carolina Oliveira de Lima;Ana Flavia Almeida Barbosa;Waleska Florentino Misael;Mariane Floriano Lopes Santos Lacerda;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.16.1-16.11
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison. Materials and Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups (n = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level. Results: No significant differences in the percentage of unprepared area were observed among the systems (p > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems (p < 0.05). The systems produced similar volumes of apically extruded debris (p > 0.05). Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.

Shape Effects on Aerodynamic and Pedestrian-level Wind Characteristics and Optimization for Tall and Super-Tall Building Design

  • Kim, Yong Chul;Xu, Xiaoda;Yang, Qingshan;Tamura, Yukio
    • 국제초고층학회논문집
    • /
    • 제8권4호
    • /
    • pp.235-253
    • /
    • 2019
  • This paper reviews shape optimization studies for tall and super-tall building design. Firstly, shape effects on aerodynamic and response characteristics are introduced and discussed. Effects of various configurations such as corner modifications, taper, setback, openings, and twists are examined. Comprehensive comparative studies on various configurations including polygon building models, and composite type building models such as corner-cut and taper, corner-cut and taper and helical, and so on, are also discussed under the conditions of the same height and volume. Aerodynamic characteristics are improved by increasing the twist angle of helical buildings and increasing the number of sides of polygon buildings, but a twist angle of $180^{\circ}$ and a number of sides of 5 (pentagon) seem to be enough. The majority of examined configurations show better aerodynamic characteristics than straight-square. In particular, composite type buildings and helical polygon buildings show significant improvement. Next, shape effects on pedestrian-level wind characteristics around tall and super-tall buildings are introduced and discussed. Corner modification buildings show significant reductions in speed-up areas. On the other hand, setback and tapered models with wider projected widths near the ground show adverse effects on pedestrian-level wind characteristics.

ProFile®, ProTaperTM 및 K3TM Ni-Ti 파일의 과기구 조작이 치근단공 변위에 미치는 영향 (A STUDY ON TRANSPORTATION OF APICAL FORAMEN AFTER OVERINSTRUMENTATION BY PROFILE® ;PROTAPERTM AND K3TM IN SIMULATED CANALS WITH DIFFERENT CURVATURES)

  • 양현;양인석;황윤찬;황인남;윤숙자;김원재;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.87-94
    • /
    • 2007
  • 본 연구는 ProFile, ProTaper 및 $K^3$를 이용하여 과잉 기구 조작에 의해 근관 성형 시 근관의 만곡형태와 Ni-Ti 파일의 종류에 따라 치근단공이 어떻게 변위 되는지를 비교 분석하고자 시행되었다. 본 실험에서는 레진모형근관으로 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다 근관성형 기구로는 $ProFile^{(R)},\;ProTaper^{TM},\;K^{3TM}$를 사용하였다. 총 60개의 레진모형근관을 사용하였으며, 사용된 레진모형근관 및 Ni-Ti 파일의 종류에 따라 10개씩 6개의 군으로 나누어 근관성형을 시행하였다. 근관 성형 전 후 이미지를 Image-analyzing microscope 100X를 이용하여 얻고 Photoshop 7.0 프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 근관 성형 전 후 치근단공의 중심으로부터의 직경 변화량과 면적을 측정한 결과 만곡된 근관의 성형시 치근단공이 주로 만곡의 외측으로 변위됨을 나타내며 ProFile이 ProTaper나 $K^3$보다 통계적으로 유의성이 있게 작은 변화량을 나타내어 근관성형시 바람직한 기구임을 시사한다.

젠지미어 압연기에서 Quarter Wave 방지 (Prevension of Quarter Wave in Sendzimir Mill)

  • 김종택;이영호;한석영;이준전;김종근
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.257-266
    • /
    • 1993
  • 본 연구에서는 보강롤의 굽힘변형을 고려한 젠지미어 압연기의 롤변형 해석을 통해, 궈터웨이브의 발생을 시뮬레이션하고, 형상제어 수단들의 궈터웨이브 억제에 미 치는 영향을 분석하여 궈터웨이브 감소 방안을 수립하였고, 실제 현장 압연실험을 통 해 그 제어효과를 확인하였다.

압축공기에너지 저장 공동의 콘크리트 플러그 최적 형상에 대한 수치해석적 연구 (Numerical Study on the Optimal Shape of Concrete Plug for Compressed Air Energy Storage Caverns)

  • 박도현;김형목;류동우;신중호;송원경
    • 터널과지하공간
    • /
    • 제21권3호
    • /
    • pp.164-173
    • /
    • 2011
  • 본 연구에서는 압축공기에너지 저장 공동의 콘크리트 플러그 최적 형상을 조사하기 위해 플러그 형상에 따른 저장 공동의 안정성을 수치해석적으로 평가하였다. 고려한 플러그 형상은 원통형, 암반에 근입된 원통형, 테이퍼형, 쐐기형이었고, 강도감소법에 의한 안전율과 압축 공기의 압력으로 인해 콘크리트에 발생하는 항복 영역의 부피비를 토대로 안정성을 분석하였다. 안정성 분석 결과, 암반에 근입된 원통형과 테이퍼형 플러그가 원통형과 쐐기형 플러그보다 역학적으로 더 안정한 것으로 분석되었다. 그러나 암반에 근입된 플러그의 경우 플러그와 암반이 접촉하는 부분에서 응력 집중이 발생하여 암반에 근입된 원통형 플러그보다는 테이퍼형 플러그 가 최적의 형상인 것을 확인하였다.

고압을 받는 MIL-S-46119 원형 밀폐링의 형상 최적화 (The Shape Optimization of MIL-S-46119 Ring Obturator Under the High Pressure)

  • 채제욱;이영신;박태규
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.1-7
    • /
    • 2003
  • The optimal design for the shape of MIL-S-46119 ring obturator under the high pressure using parameter stud:』 on the stress analysis considering effects of design variable is presented, and it is compared to experimental results. The trends of parametric study are in good agreement with the experimental results. The more thickness the higher stress. The more taper the higher stress. And maximum stress of circumferential surface is larger than maximum stress of forward surface. The design variable!; are such as thickness, taper, radius of shape of the obturator. In order to optimize the shape of obturation ring, the weight is maximized subject to maximum stress of the obturator within allowable stress. The design constraints are geometric elements of design variables.