• 제목/요약/키워드: Tape measurement

검색결과 160건 처리시간 0.025초

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정 (Scattering Measurement of Syringe Shield Used in PET/CT)

  • 장동근;박철우;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

고관절 전치환술(Total Hip Replacement Arthroplasty) 환자의 수술후 활동저하가 하지근 위축에 미치는 영향 (Effect of a decreased activity following THRA on circumference, volume and strength of normal and operated lower extremities)

  • 채영란;최명애
    • 대한간호학회지
    • /
    • 제24권1호
    • /
    • pp.115-128
    • /
    • 1994
  • The purpose of this study was to observe the change of circumference, volume and strength of normal and operated lower extremities on 3rd, 7th, 10th, and 14th days of postoperation following THRA compared with their condition on preoperation day. Subjects consisted of 13 male and 7 female Patients operated with THRA between the age of 20 and 69 years with a mean age of 38.55(SD=15.1). Circumference of upper and lower leg was measured by tape, leg volume was determined according to formula (Moor & Thornton, 1987) with measurement of 8 circumferences of leg. Leg strength was measured by pressing the center of digital health meter in supine position. The results can be summarized as follows : 1. Circumference of operated thigh decreased significantly at 14 following THRA compared with preoperative value, while that of normal thigh decreased significantly at day 3, 7, 10 and 14 after THRA compared with preoperative value. 2. Circumference of midcalf in both operated and normal limb decreased significantly at day 3, 7, 10 and 14 following THRA compared with preoperative value. 3. Leg volume of operated lower limb decreased significantly at 10, 14 following THRA compared with preoperative value, while that of normal limb decreased significantly at day 7 & 10 after THRA compared with preoperative value.4. Leg strength of operated limb decreased significantly at day 3, 7, 10, 14 following THRA compared with preoperative value. No significant difference of normal leg strength was shown following THRA. 5. Circumference of midcalf differed significantly at day 14 after THRA between normal and operated extremity. From these results, it can be suggested that a decreased activity after THRA caused muscle atrophies in normal and operated extremity.

  • PDF

척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구 (Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera)

  • 나창수;정효상;김지현
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

교류전류를 이용한 비접촉결함탐상법에 관한 연구 - 주파수 lift-off의 영향 - (A Study on the Non-Contact Detection Technique of Defects Using AC Current - The Influence of Frequency and lift-off -)

  • 김훈;나의균
    • 비파괴검사학회지
    • /
    • 제22권1호
    • /
    • pp.53-58
    • /
    • 2002
  • 계자코일에 흐르는 교류전류로 전자기장을 유도하고, 결함에 의하여 누설되는 자속을 간극을 갖는 헤드로 측정하여 결함을 검출하는 새로운 비파괴탐상장치를 구성하였다. 이 탑상장치는 비접촉으로 강자성체의 구조물 요소에 존재하는 표면결항을 검출하고, 그 크기를 평가하는데 적용할 수 있다. 본 논문은 강자성체에 도입한 2차원 표면결함에 적용하여 결함의 평가를 실시하였다. 또한 측정주파수와 lift-off가 이들 평가에 미치는 영향을 검토하였다. 결함은 전압 분포에서 최대치로 검출할 수 있고, 이 최대전압의 변화는 결함의 깊이가 증가함에 따라 증가한다. 결함의 최대전압은 주파수와 lift-off 의 영향을 받지만, 작은 깊이의 결함은 깊이와 전압이$(V_0/V_{ave})$의 관계로부터 선형적으로 예측할 수 있다.

Relationship between Kinesiotaping and compression wear for postural balance in healthy men: a cross-sectional study

  • Choi, Nak-Hoon;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권4호
    • /
    • pp.275-280
    • /
    • 2020
  • Objective: Compression wear is an external aid which promotes performance and recovery, diminishes muscular microtrauma, reduces muscle fiber recruitment, improves neuromechanics, enhances coordinative activities, and reduces the perceived exertion. The purpose of this study was to investigate the relationship between athletic taping and compression wear on dynamic postural balance in healthy young men. The hypothesis was that the athletic taping and compression wear would affect dynamic postural balance, with athletic taping having a different effect on dynamic postural balance in healthy young adults. Design: Cross-sectional study. Methods: Thirty-seven healthy young men participated in this study. To examine the association between athletic taping and compression wear, 3 clinical measurement tools, including 5 times sit-to-stand (5xSTS), one-leg standing (OLS) test, and Y-balance test (YBT) in 5 different conditions, namely (1) non-supporting, and support with (2) athletic taping, (3) regular compression wear, (4) silicon compression wear, and (5) double-fiber compression wear were used. Results: The distance of the Y-balance test (YBT) on both the dominant and non-dominant sides showed a statistically difference among the 5 supporting conditions (p<0.05). The distance measured via the YBT in the non-support condition was significantly different than that in the other four supporting conditions (p<0.05). However, 5xSTS and OLS were not significantly different in these supporting conditions. Conclusions: The results of this study suggest that athletic taping, silicon compression wear, and double-fiber compression wear were more effective for dynamic balance than non-supporting and regular compression wear.

호흡운동이 만성요통환자의 굽힘이완현상과 호흡변수에 미치는 영향 (Effects of Breathing Exercise on Flexion Relaxation Phenomenon and Thoracic Excursion in Patients with Chronic Low Back Pain)

  • 조병윤;윤정규
    • 대한통합의학회지
    • /
    • 제7권1호
    • /
    • pp.125-134
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the effects of stabilization exercise and breathing exercise on the flexion relaxation phenomenon (FRP) and respiratory parameters in patients with chronic low back pain. Methods : We randomly allocated 30 chronic low back pain patients (CLBP) to a stabilization exercise (SE) group (n=15) and a breathing exercise (BE) group (n=15). FRP was measured using surface electromyography (SEMG). Thoracic excursion was measured with a cloth tape measurement technique. The SE group participated in a stabilization exercise program and the BE group participated in a breathing exercise program three times a week for 12 weeks. The data was analyzed using paired t-tests for comparisons of flexion relaxation ratio (FRR) and respiratory variables. Independent t-tests were used for comparison of inter-group FRR and respiratory variables. The significance level was set at .05. Results : FRP variables-ES FRR (Flex/MVF), ES FRR (Ext/MVF), MF FRR (Flex/MVF), and MF FRR (Ext/MVF) values-increased significantly after exercise in both the SE and BE groups (p<.05). The thoracic excursion measurements after exercise increased significantly in both groups (p<.001). VAS values decreased significantly in both groups (p<.001). There were no significant differences between the two groups in FRP variables-ES FRR (Flex/MVF), ES FRR (Ext/MVF), MF FRR (Flex/MVF), and MF FRR (Ext/MVF)-or VAS values after exercise (p>.05). For thoracic excursion after exercise, the BE group was significantly higher than the SE group (p<.001). Conclusion : We found that FRP and respiratory variables increased significantly after SE and BE for 12 weeks in CLBP. Thoracic excursion-a respiratory variable-suggests that treatment was more effective in the BE group than the SE group.

The fabrication of bulk magnet stacked with HTS tapes for the magnetic levitation

  • Park, Insung;Kim, Gwantae;Kim, Kyeongdeok;Sim, Kideok;Ha, Hongsoo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.47-51
    • /
    • 2022
  • With the innovative development of bio, pharmaceutical, and semiconductor technologies, it is essential to demand a next-generation transfer system that minimizes dust and vibrations generated during the manufacturing process. In order to develop dust-free and non-contact transfer systems, the high temperature superconductor (HTS) bulks have been applied as a magnet for levitation. However, sintered HTS bulk magnets are limited in their applications due to their relatively low critical current density (Jc) of several kA/cm2 and low mechanical properties as a ceramic material. In addition, during cooling to cryogenic temperatures repeatedly, cracks and damage may occur by thermal shock. On the other hand, the bulk magnets made by stacked HTS tapes have various advantages, such as relatively high mechanical properties by alternate stacking of the metal and ceramic layer, high magnetic levitation performance by using coated conductors with high Jc of several MA/cm2, consistent superconducting properties, miniaturization, light-weight, etc. In this study, we tried to fabricate HTS tapes stacked bulk magnets with 60 mm × 60 mm area and various numbers of HTS tape stacked layers for magnetic levitation. In order to examine the levitation forces of bulk magnets stacked with HTS tapes from 1 to 16 layers, specialized force measurement apparatus was made and adapted to measure the levitation force. By increasing the number of HTS tapes stacked layers, the levitation force of bulk magnet become larger. 16 HTS tapes stacked bulk magnets show promising levitation force of about 23.5 N, 6.538 kPa at 10 mm of levitated distance from NdFeB permanent magnet.

짐볼을 이용한 목과 어깨의 안정화 운동이 건강한 20대 여성의 둥근어깨와 머리내밈자세에 미치는 영향 (The Effect of Shoulder and Neck Stabilization Exercise Using Gym Ball on the Posture of Healthy Women in Their 20s with Round Shoulder and Forward Head Posture)

  • 임경은;정연우
    • 대한정형도수물리치료학회지
    • /
    • 제29권2호
    • /
    • pp.59-67
    • /
    • 2023
  • Background: The purpose of this study is to analyze the effect of shoulder and neck stabilization exercise using a gym ball for healthy women in their 20s with round shoulder and forward head posture, it is intended to try and find improvement for posture. Methods: The subjects of the study were 25 women who understood the purpose of the research and voluntarily agreed to participate in the experiment. They carried out the shoulder and neck stabilization exercise program using a gym ball, which was conducted for 35 minutes, 3 times a week for 4 weeks. The position of the round shoulder and shoulder bones was measured using an tape measurement and were recorded in both at pre, 2 weeks, and post intervention. The craniovertebral angle (CVA) and craniorotational angle (CRA) was measured using an image J. Results: The round shoulder posture left was statistically significantly different within group (p<.05); however, the round shoulder posture right wasn't statistically significantly different (p>.05). As a result of this contrast, test were significant different in both at pre, 2 weeks and post. The scapular position on the left and right were statistically significantly different within the group (p<.05). As a result of the contrast, test were significant different in both at pre, 2 weeks and post (p<.05). The CVA and CRA on the left and right were statistically significantly different within the group (p<.05). As a result of the contrast, test were significant different in both at pre, 2 weeks and post (p<.05). Conclusion: The gym ball exercises improved the posture of women in their 20s. Therefore, gym ball exercises can help improve the quality of life of those with shoulder and neck pain.

  • PDF

The physical properties of several HTS coated conductors

  • Lee, Nam-Jin;Oh, Sang-Soo;Song, Kyu-Jeong;Ha, Dong-Woo;Kim, Ho-Sup;Ha, Hong-Soo;Ko, Rock-Kil;Kim, Tae-Hyung;Kim, Sang-Cheol;Yu, Kwon-Kuk;Moon, Seung-Hyun;Youm, Do-Jun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권4호
    • /
    • pp.19-23
    • /
    • 2007
  • The superconducting properties of several HTS coated conductors (CC), which had different tape structures, fabricated by KERI, X and Y institutes were compared. We have fabricated the $high-J_c$ SmBCO CC, which has 273.5 A/cm, $1.2MA/cm^2$ and 93.5 K for $I_C,\;J_C\;and\;T_{c-zero}$, respectively, using the EDDC (Evaporation using Drum in Dual Chambers) process. Both X and Y institutes CCs, however, were purchased. The n-values of KERI, X and Y institutes CCs are 58.5, 40.7 and 31.5 in $V=1{\sim}10{\mu}V$ criterion, respectively. The in-field properties of $I_C$ at 77K were investigated and the $J_C(B)/J_C(0G)$ at 0.5 T with $B{\perp}$ ab-plane are 0.31, 0.19 and 0.24 for KERI, X and Y institutes CCs, respectively. From the $I_C-{\theta}-B$ measurement, we observed that the ab-plane of ReBCO phase was tilted for the ab-plane of substrate in the KERI and X institutes CCs. The tilted angle is about 5 degree. We confirmed that the peak shift (as an inclined texture) was observed by X-ray (102) pole figures of the SmBCO for the KERI CC.

가슴 가동성 제한을 가지고 있는 대상자에게 가슴 가동성 운동이 가슴가동성, 호흡패턴 및 호흡량에 미치는 효과: 사례 시리즈 (Effects of Thorax Mobility Exercise on the Thorax Mobility, Breathing Pattern and Respiratory Capacity in Subject With Restricted Thorax Mobility: A Case Series)

  • 하성민
    • 재활치료과학
    • /
    • 제12권2호
    • /
    • pp.99-107
    • /
    • 2023
  • 목적 : 본 연구는 가슴 가동성 제한을 가지고 있는 대상자에게 가슴 가동성 운동이 가슴 가동성, 호흡 패턴 및 호흡 용량에 미치는 영향을 알아보고자 하였다. 연구방법 : 13명의 가슴 가동성 제한을 가진 남/녀 대상자를 대상으로 가슴 가동성 운동(갈비뼈 가동성 운동)을 시행하여 가슴 가동성, 호흡 패턴 및 호흡량에 어떠한 변화가 있는지를 알아보았다. 가슴 가동성 운동 전/후에 연구 참여 대상자의 가슴 가동성(들숨-날숨 간 가슴 확장 길이 측정), 호흡 패턴 형태(가슴 움직임 수직 이동거리 측정) 및 호흡량(forced vital capacity, forced expiratory volume in 1 second)을 측정하였다. 가슴 가동성, 호흡 패턴 및 호흡 용량을 비교하기 위하여 짝-검정을 사용하였다. 통계적 유의성 검정을 위한 유의수준은 .05였다. 결과 : 가슴 가동성과 호흡 패턴은 통계적으로 유의한 차이가 있지만, 호흡 용량은 유의한 차이가 없었다(p < .05). 결론 : 본 연구의 결과를 토대로 갈비뼈 가동화 기법을 이용한 가슴 가동성 운동은 가슴 가동성 개선과 가슴 올림이 유발되는 비정상적인 호흡 패턴을 정상화시킬 수 있는 방법이라고 여겨진다.