• Title/Summary/Keyword: Tap change

Search Result 109, Processing Time 0.033 seconds

Development Pole Transformer with Automatic Tap Changer (자동 탭 절환 내장형 주상변압기 개발에 관한 연구)

  • Nam-Koong, Won;Lee, Sung-Woo;Jang, Moon-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.108-113
    • /
    • 2013
  • Change of supply voltage, customer load, output of distributed generation, etc cause voltage change in distribution system. OLTC and SVR are usually used to supply normal voltage at customer. But usage of these devices is inefficient and uneconomical in certain circumstances. To solve this problem, new pole transformer which has automatic tap changer is developed. The transformer changes tap when voltage changes. And it has latch switch and reactor for supplying power without outage. To verify normal operation of tap changer, test is conducted. SVR and 50kVA load is used for test.

Starting Characterization of Induction Motor using Reactor Tap Change (리액터 탭 절환에 의한 유도전동기의 기동 특성)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • An induction motor is most widely used to obtain driving force in the industrial field. The induction motor is generated a high current at starting. A starting current is often more than five times of rated current. A high starting current can cause problems such as voltage drop in the power system. In order to solve these problems, a reactor starting method has been widely applied in a large motor capacity. There are differences in the operating characteristics of induction motor corresponding the switching time of reactor tap. In this study, I analyzed that current, torque, power of induction motor are different from changing time and tap setting values of reactor tap.

Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

Analysis of Argumentation Structure in Students' Writing on Socio-scientific issues (SSI): Focusing on the Unit of Climate Change in High School Earth Science I

  • Yoo, Bhyung-ho;Kwak, Youngsun;Park, Won-Mi
    • Journal of the Korean earth science society
    • /
    • v.41 no.4
    • /
    • pp.405-414
    • /
    • 2020
  • In this study, we analyzed the development of high school students' argumentation through their writings on socio-scientific Issues (SSI) related to the Climate Change Unit in the Earth Science I curriculum. Pre- and post-writing assignments on the two main causes of global warming were analyzed and compared. In addition, an in-depth interview of the focus group was conducted with 7 students who showed a distinct change in the level of argumentation. According to the results, 16 of 52 students remained at the same argumentation level in pre- and post-writing assignments, and students remaining at Level 2 among five levels had difficulty in understanding the Toulmin's argument pattern (TAP) structure. Using the TAP structure, 29 of 52 students demonstrated increased argumentation levels in the post-writing assignments. The conclusions include that writing lessons on SSI using the TAP in Earth science classes can improve the level of high school students' argumentative writing, and that the level of students' argumentation can develop with the elaboration of their level of falsification. Also, it is suggested that the science curriculum should increase students' science writing competencies by specifying science writing as one of the goals.

Performance improvement of PV_system's inverter that use transformer tap (변압기 탭을 이용한 태양광인버터의 성능개선)

  • Park Noh-Sik;Park Sung-Jun;Kim Kwang-Heon;Lim Young-Cheol;Kwon Soon-Jae;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.511-514
    • /
    • 2004
  • Proposed about new inverter that can use in PV system in this paper. Multi_level inverter that used inverter makes use of 4 transformers is basis, primary winding of each transformer voltage as can do step_up or step_down to appropriate voltage space tap lake. Put circuit that tap that turn in transformer connects properly according to inhibit signal that sense change of input voltage (output voltage of solar cell place) and transformer secondary voltage controls point of contact of relay so that get into fixed output voltage. As a result, can minimise relative harmonic content despite change width of input voltage are wide because number of output voltage level of multi_level inverter does not decrease. Because proposed circuit manufactures is easy and control is easy and is no burden of cost price rise economically, commercialization expected to do easily and this study examined propriety of action as that compose and experiments proposed circuit.

  • PDF

Shunt-Responsive Idiopathic Normal Pressure Hydrocephalus Patient with Delayed Improvement after Tap Test

  • Kang, Kyunghun;Hwang, Sung Kyoo;Lee, Ho-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.437-440
    • /
    • 2013
  • The cerebrospinal fluid tap test (CSFTT) is recommended as a key step in the diagnosis of idiopathic normal pressure hydrocephalus (iNPH). While there is no generally accepted evaluation period for ascertaining a CSFTT responder, a substantial number of patients are evaluated only once within 24 hours of the test for improvement in gait. We report an iNPH patient with a favorable response to shunt surgery, who was first judged a non-responder by this standard, though subsequently was judged a responder in virtue of repetitively testing gait over 7 days. A 68-year-old man presented with progressive impairment of gait, balance, and memory. He was diagnosed as iNPH with an Evans' ratio of 0.35. At first hospitalization, change in gait was evaluated 24 hours after the CSFTT. He didn't show any significant improvement and was judged as a non-responder. However, at the second CSFTT, we repetitively tested his change in gait over seven days. Forty-eight hours after the tap, he showed significant improvement in his gait. He was then confirmed as a responder. After the operation, the gait difficulties were almost fully resolved. Further studies developing the standard procedure of the CSFTT should be considered.

Digestive Enzymatic and Nucleic Acidic Responses of Olive Flounder Paralichthys oilivaceus Larvae Fed Cyclopoid Copepod Paracyclopina nana (기수산 Cyclopoid 요각류 Paracyclopina nana를 섭취한 넙치 Paralichthys olivaceus 자어의 핵산 함량과 소화효소적 반응)

  • Kwon, O-Nam;Lee, Kyun-Woo;Kim, Gun-Up;Park, Heum-Gi
    • Journal of Aquaculture
    • /
    • v.21 no.3
    • /
    • pp.190-195
    • /
    • 2008
  • We investigated the changes in growth, digestive enzymes activities, nucleic acids contents and RNA/DNA ratio of flounder Paralichthys olivaceus larvae (C for Paracyclopina nana, A for Artemia, and M for Mix of C and A) for 14 to 28 DAH. Body length of flounder larvae showed the best in the C trial at 28 DAH. The change of nucleic acids contents showed faster in C and M trials than A trial. And RNA/DNA ratio showed the significantly faster changes in C trial than A trial. High metamorphosis rates were also observed in C and M trial. $\alpha$-amylase activities increased gradually up to 28 DAH in all trials. Total alkaline protease (TAP) activities of A trial showed the highest value to 9 mU/larvae at 26 DAH. But others trials showed lower to $5{\sim}6$ mU/larva than A trial. TAP:$\alpha$-amylase activity ratio did not significantly changed to $0.025{\sim}0.053$ in A trial during the experiments. But, C and M trials tended to gradually decrease from $0.078{\sim}0.083$ (initial) to $0.013{\sim}0.018$ (final). Therefore, it shown the ratio gradually decreased of TAP:$\alpha$-amylase activity, stability of TAP activity, and rapid change of nucleic acids in trials grown positively. Thus, because P. nana could continuously supply the optimal nutrients for flounder larvae, we suggested the supplement of the copepod to an efficient feed of the flounder larvae.

An Equalization Technique for OFDM and MC-CDMA in a Slowly Time-Varying Multipath Fading Channel (시변 다중 경로 페이딩 채널에서 OFDM, MC-CDMA의 등화 기법)

  • 최종호;조용수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.3-7
    • /
    • 1996
  • In this paper, the performances of OFDM and MC-CDMA systems in a slowly-varying multipath fading environment is investigated. Time variation of the multipath channel leads to both a change of an optimal coefficient in one-tap equalizer and a loss of subchannel orthogornality, resulting in significant performance loss. A new simple one-tap equalizer which can reduce the effect of slowly time-varying multipath channel is proposed by taking into account time-variation of multipath profile and modifying the previous equalization techniques. It is demonstrated by computer simulation that the performances of OFDM and MC-CDMA systems can be improved by using the proposed one-tap equalizers when the multipath channel is slowly varying.

  • PDF

A study on Availability of Magnetic treatment water as a cooking water (조리용수로써 자화수의 기능성에 관한 연구 -건조물의 수화능력을 중심으로-)

  • Jang, Jeong-Ock;Lee, Young-Mee
    • Journal of the Korean Society of Food Culture
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 1996
  • We have studied specific properties of magnetic treated water as processing water will make different cookery form the case of piped tap water. The result is as follows; The magnetic treated water both from tap water and pure water became more alkaline than not-magnetic treated water in pH change. As time goes on, magnetic treated or not, pH reduced considerably in piped tap water and increased in pure water. The magnetic treated water showed higher hydration rate than piped tap water in hydration of dried food. According to time, difference of hydration between tap water group and magnetic-treatment water group became significantly. Surface tension of magnetic treated water was slightly lower than that of piped tap water. And it reduced considerably with time. The magnetic treated water showed significantly effective outflow of salt especially in initial phase of soaking in salt-in food.

  • PDF

Influence of C/N ratio on biofim growth in tap water (수돗물의 C/N 비율이 생물막 생장에 미치는 영향)

  • Cho, Ji-Min;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.527-533
    • /
    • 2018
  • Microorganisms detected in the biofilm not only cause secondary pollution of drinking water such as taste, odor and pathogenic disease but also increase the amount of disinfectant due to microbial regrowth during the transportation of tap water. In this work, the influence of C/N ratio in tap water on the characteristics of biofilm growth was examined. The C/N ratio of the tap water sample was controlled at 100:5, 100:10, 100:20, 100:30, and 100:40 by adding appropriate amounts of dextrose and $(NH_4)_2SO_4$. Of the five C/N ratios, heterotrophic plate counts (HPC) was highest at the ratio of 100:10. Following the initial formation in all the five experimental conditions, natural detachment of the biofilm was observed. Extracellular enzyme activity (EEA) analyses showed that the change of the EEA during the experimental period was similar to that of the HPC, demonstrating a positive correlation between HPC and EEA. For TOC concentration in the tap water sample, approximately 75% of the TOC was consumed in 7 days of the experiment and 96% in 28 days. The TOC appeared to be relatively rapidly consumed at the initial phase of the biofilm growth. Consumption pattern of the ammonia nitrogen was different from the TOC consumption pattern showing the different role of ammonia nitrogen on the growth of biofilm.