• 제목/요약/키워드: Tank Wall

검색결과 286건 처리시간 0.03초

대형 캐비테이션터널에서 몰수체 저항시험 및 위벽효과 수정 기법 연구 (Study of the Resistance Test and Wall Blockage Correction Method for the Submerged Body in LCT)

  • 안종우;설한신;박영하;김기섭
    • 대한조선학회논문집
    • /
    • 제57권3호
    • /
    • pp.133-139
    • /
    • 2020
  • In order to study the resistance test technique for the submerged body in Large Cavitation Tunnel (LCT), DARPA Suboff, submarine model publicly available was manufactured. DTRC released the resistance test data of DARPA Suboff conducted at ship speeds up to 18.0 knots in high-speed towing tank in 1990. As LCT is considered restricted waterways with walls, the resistance test results must be corrected with three wall blockage effects called buoyancy effect, solid blockage effect and wake blockage effect. Before correction, the resistance of LCT was 16~20 % higher than that of DTRC. After correction, the resistance and the resistance coefficients were compared with those of DTRC. The corrected resistance of LCT shows good agreement with that of DTRC. The residual resistance coefficient shows the difference according to the calculation method of buoyancy and frictional resistance coefficient. This paper suggests the best way for the calculation of residual resistance coefficient, On the basis of the present study, it is thought that the operating conditions for the propeller cavitation and noise tests can be drawn through LCT tests.

구벽안정성을 위한 SMW 최적배합비 및 현장적용 사례에 관한 연구 (An Experimental Study on the Optimum Mix Design and Site Application Case of Soil Mixing Wall for Trench Stability)

  • 권영호
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.419-426
    • /
    • 2015
  • 본 연구는 지하식 LNG 저장탱크의 시공에 앞서 연약지반의 개량을 위하여 현장 원위치의 흙과 시멘트, 벤토나이트 등을 사용하는 소일-시멘트 연속벽체를 효과적으로 시공하는 SMW 공법에 대한 배합설계 및 현장적용 사례를 실험적으로 규명하기 위한 것이다. 현장조건을 고려하여, 보통 포틀랜드 시멘트와 벤토나이트를 주재료로 선정하였고, 흙의 단위용적중량은 $1,833kg/m^3$을 적용하였으며, 이에 따른 물-시멘트비 4종류와 배합속도 3수준을 대상으로 블리딩 및 압축강도 실험을 실시하였다. 실험은 실내실험 및 현장적용 사례로 나누어 수행되었으며, 실험을 통하여 얻은 결론은 다음과 같다. (1) 물-시멘트비가 감소할수록, 배합속도(rpm)이 증가할수록, 블리딩량 및 블리딩율이 감소하는 것으로 나타났다. (2) 물-시멘트비 150% 이하에서 현장적용강도(1.5 MPa)를 만족하였으며, 현장 코아강도는 공시체 강도에 비해 8~23% 증가하였다. 따라서 적용현장 조건을 고려하여 단위시멘트량 $280kg/m^3$, 벤토나이트 $10kg/m^3$, 물-시멘트비 150%, 그리고 배합속도 90 rpm을 현장시공의 최적배합으로 제안하였으며, 현장적용 사례의 실험결과로부터 요구되는 성능을 만족하였다.

발전소 Deaerator floor의 복사효과 저감을 위한 열유동 해석 (A thermal-flow analysis of deaerator floor of power plant for reducing the radiative heat transfer effect)

  • 김태권;하지수;최용석
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.476-481
    • /
    • 2016
  • 화력발전은 화석연료인 석탄을 연소시켜 얻은 열에너지로 물을 끓여 증기를 만들고 그 증기로 터빈을 운전시켜 터빈축에 연결된 발전기로 전기를 얻는 방식이다. 따라서 하절기에는 화력발전소 Deaerator의 표면온도는 $70^{\circ}C$, Storage Tank의 표면온도는 $67^{\circ}C$, 공기온도는 $50^{\circ}C$를 상회한다. 이런 현상은 기기와 작업자에게 부적합한 영향을 끼친다. 특히, Deaerator와 Storage Tank에 인접해 있는 작업자는 복사열전달의 영향을 받아 더 높은 체감온도를 느끼게 된다. 따라서 본 논문에서는 전산해석을 통해 Deaerator 부근의 열유동 특성을 파악하고 단열재를 사용하였을 때와 복사차폐막을 사용하였을 때의 효과를 비교하여 최적의 냉각조건을 제시하였다. Case 1은 현재 발전소의 형상이고 Case 2는 Case 1에서 단열재를 추가로 사용한 형상이고 Case 3은 Case 1에서 복사차폐막을 사용한 형상이다. 유동은 벽면과 열원의 온도 차이에 의해 발생되었고 오른쪽 상단부에 고온의 공기가 포집된다. 온도 분포에서 작업자표면의 최대 온도를 비교해보면 단열재를 사용한 Case 2가 복사효과 저감에 가장 효율적인 것으로 나타났다.

탄산염해에 대한 LNG 저장탱크 PC 외부벽체의 수명평가 및 억제방안 (Service Life Assessment and Restrain Methods of Carbonation Attack on PC Outer Wall of LNG Storage Tanks)

  • 이승림;송일현;김한상
    • 한국가스학회지
    • /
    • 제18권2호
    • /
    • pp.73-80
    • /
    • 2014
  • 본 연구는 현재 신설 중에 있는 삼척 LNG 저장탱크 콘크리트 배합표의 공시체로부터 획득된 촉진 탄산화 시험 결과를 가지고 탄산염해에 대한 내구수명과 그 억제 방안에 대해 평가한 것이다. 그 결과 재령 7일, 28일, 56일에 대한 촉진 탄산화 침투 깊이는 4.45 mm, 9.19 mm, 13.37 mm로 나타났으며, 실제 운영 중 LNG 저장탱크의 철근피복 두께(최소 70 mm부터 최대 100 mm)를 고려하더라도 큰 여유를 보였다 그리고 탄.산화 침투 깊이로부터 획득된 탄산화 속도계수를 가지고 대기 중 환산 $CO_2$ 농도 즉, 0.03%와 0.05%를 각각 고려한 LNG 저장탱크 외조 콘크리트의 설계 피복 두께(70 mm, 80 mm, 90 mm, 100 mm)의 내구수명은 779년, 1,017년, 1,287년, 1,589년과 466년, 609년, 771년, 951년으로 나타났다. 또한, 콘크리트 경화체내 조직구조의 물질이동성 변화와 세공용액의 이온조성 및 수산화칼슘 등 수화생성물의 변화 등에 영향을 미치는 인자들의 조절을 통하여 탄산염해의 억제가 가능할 것으로 보였다.

충전층을 이용한 암반공동 열에너지저장시스템의 열에너지 수지 분석 (Thermal Energy Balance Analysis of a Packed Bed for Rock Cavern Thermal Energy Storage)

  • 박정욱;류동우;박도현;최병희;신중호;선우춘
    • 터널과지하공간
    • /
    • 제23권3호
    • /
    • pp.241-259
    • /
    • 2013
  • 충전층을 이용한 열에너지저장 시스템은 자갈이나 콘크리트와 같은 열저장매질과 공기나 오일과 같은 열전달유체를 이용하여 현열에너지를 저장하는 방식으로서, 저장매질의 경제성과 화학적 안정성, 시스템 구축의 용이성 등 많은 장점이 갖는다. 본 연구에서는 충전층을 이용한 열에너지저장 기술에 대하여 개략적으로 소개하고, 이러한 열에너지저장소의 에너지 수지와 성능 효율을 분석하기 위한 수치 모델을 제시하였다. 유한차분법을 이용하여 저장소 내 1차원 비정상 열전달 해석을 수행하였으며, 반복적인 주입과 토출에 따른 충전층의 온도분포와 외부로의 손실 에너지를 계산하였다. 해석모델은 AA-CAES(advanced adiabatic compressed air energy storage)와 연계된 고온의 열에너지저장시스템으로 저장소가 지하암반 내에 위치하는 경우와 지상에 위치하는 경우를 모사하고, 성능효율 및 열손실률을 비교 분석하였다.

지표면 재하시 사질토 지반의 상대밀도에 따른 지중 연직응력분포 특성 (Characteristics of Vertical Stress Distribution in Soil according to the Relative Density of Sandy Soil in case of Surface Loading)

  • 임종석;이인형;정원중
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.422-426
    • /
    • 2003
  • Model soil tank tests were conducted in sandy soil to investigate the effect of surcharge strip loads on vertical stress distribution in soil. A total number of 6 tests were performed using one loading plate and two relative density(55%, 65%). The soil was considered as an elastic material, while no friction was allowed between the wall and the soil. Measured stress values were compared to predictions defined by Frohlich, Boussinesq and Westergaard. The comparison of measured values and predictions used the ratio between the soil pressure and load value. Results of this study demonstrated that experimental values were generally larger than predictions. The Frohlich analysis provided the best prediction, while the Boussinesq analysis and Westergaard theory not presented a satisfactional result.

  • PDF

왕겨 연소기(燃燒機)를 이용(利用)한 온수(温水)보일러 시스템 개발(開發)(II) -시뮬레이션 모형(模型) 개발(開發)- (Development of A Hot Water Boiler System with A Rice Hull Furnace -Development of A Mathematical Model of Simulation-)

  • 박승제;노상하;이용국
    • Journal of Biosystems Engineering
    • /
    • 제13권4호
    • /
    • pp.30-37
    • /
    • 1988
  • A mathematical model was developed and programmed for computer simulation of a prototype hot water boiler system with rice hull furnace to predict the temperature distributions in the rice hull furnace and water tank, mass flow rate of hot water and thermal efficiency of the system under various operation and design conditions. The effects of feed rate of rice hull, thickness of the furnace wall, the type of heat exchanger, diameter of the water circulation pipe, etc, on the performance of the system can be evaluated with this model. The validity and simulation results of this model will be published in the next paper.

  • PDF

유체장 변화에 따른 사각형 탱크의 진동에 관한 연구 (Case study on hydroelastic vibration of plate for various bounded fluid field)

  • 김극수;최수현;조현동
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.855-860
    • /
    • 2006
  • In this paper, a numerical case study is carried out on the hydroelastic vibration of rectangular plate with various fluid field. It is assumed that the tank wall is clamped along the plate edges. The VMM(Virtual Mass Method) of Nastran is used for the simulation of fluid domain and calculating natural frequency of fluid-coupled structure. In this paper, natural frequencies are calculated and compared for rectangular plates with various fluid field such as infinite fluid and finite fluid, length change of finite fluid field and various fluid contacting conditions.

  • PDF

저열 포틀랜드 시멘트를 사용한 고유동콘크리트의 사용재료 및 배합 변동에 따른 특성 평가 (The Effect on the Properties of High Flowing Concrete Using Low Heat Portland Cement by Material and Mixing Variations)

  • 하재담;김태홍;유재상;이종열;권영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.303-308
    • /
    • 2001
  • Recently, concrete structures have become larger and higher and are demanding high performance concrete with lower heat to prevent thermal cracking, far greater workability, high strength and durability, Application of low heat portland(Type IV) cement for the high performance concrete is the best solution to satisfied those requirements. Here are explained the effect on the properties of high flowing concrete using low heat portland cement by material and mixing variations. Variables for sensitivity test were selected items like finess modulus of aggregates, particle size of limestone powder, unit water, superplasticizer, viscosity agent and concrete temperature. The results of this study were be applied to slurry wall of #215 and #216 of underground LNG tank in Inchon.

  • PDF

직립 슬릿판에 의한 반사율과 투과율 해석 (On an Analysis of Reflection and Transmission Coefficients by a Vertical Slit Plate)

  • 조일형;김남형
    • 한국해양공학회지
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2002
  • In this paper, a numerical model to analyze the performance of a vertical slit-type wave absorber is developed under the assumption of inviscid water waves. The formulation combines the linear potential theory with a semi-empirical description of the eddy-shedding at a slit-type wave absorber. We investigated the reflection coefficients over a wide frequency range for a vertical slit-type wave absorber both with and without a solid rear wall. Model test was conducted at KRISO' s two dimensional wave tank to validate the theoretical results. It is found that the agreement between theoretical results and experimental data is surprisingly good. We found that the wave absorbing system using a vertical slit plate has sufficient potentials for breakwaters for ocean development.