• Title/Summary/Keyword: Tank Wall

Search Result 288, Processing Time 0.023 seconds

Motion and Sloshing Analysis for New Concept of Offshore Storage Unit

  • Ha, Mun-Keun;Kim, Mun-Sung;Paik, Bu-Keun;Park, Chung-Hum
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.5 no.1
    • /
    • pp.22-28
    • /
    • 2002
  • A New concept for the LNG-FPSO ship, with moonpool and bilge step in bottom, is proposed. This concept is investigated with regard to motion reduction and sloshing phenomena of the cargo and operation tanks. The principal dimensions of the ship are $L\timesb B\times D\times t(design)=270.0\times51.0\times32.32\times13.7(m)$, with a total cargo capacity of 161KT; a 98% loading condition is considered for this study. The moonpools and rectangular step at the bilge have been designed for the purpose of decreasing the motion within the tank. For the motion analysis, linearized three-dimensional diffraction theory, with the simplified boundary condition was used. The six-degree of freedom coupled motion responses were calculated for the LNG-FPSO ship. Viscous effects on the roll motion responses of a vessel were taken into account in this calculation program, using an empirical formula suggested by Himeno(1981). The case study for the moonpool size has been conducted using theoretical estimation and the experimental method. For the optimization of the moonpool size and effect of the bilge step, 9 cases of its size, both with and without bilge step, were involved in the study. no motion responses, especially roll motion, for the designed LNG-FPSO ships are much lower than those of other drill ships and shuttle tankers. The limit criterions are satisfied. To check the cargo tank and operation tank sizes, we performed a sloshing analysis in the irregular waves which focuses on the pressure distribution on the tank wall and the time history of pressure and free surface for No.2 and 5 tanks of LNG-FPSO with chamfers. Finally, optimum tank sire was estimated.

  • PDF

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

Seismic Fragility Analysis of Ground Supported Horizontal Cylindrical Tank (수평원통형 저장탱크의 지진취약도 해석)

  • Chaulagain, Nabin Raj;Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.145-151
    • /
    • 2019
  • The fragility analyses for the partially filled horizontal cylindrical tank having a flexible wall were conducted to evaluate seismic performance. An equivalent simplified model with two lumped masses representing to impulsive and convective masses was used to represent the liquid storage system. This simplified model was validated by comparing its time history analysis results with the 3D FSI model results. The horizontal tank was analyzed under bi-directional excitations. Seismic fragility curves for the stability were developed in transverse and longitudinal directions. Fragility curves show that seismic damage for the horizontal storage system is more susceptible in the transverse direction.

A Study on the Mixing Characteristics in Complex Turbulent Flow by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 복잡 난류유동장의 혼합특성에 관한 연구)

  • Kim, Kyung-Chun;Jeong, Eun-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.542-547
    • /
    • 2001
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera can be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration in each region after the dye infusion reflects the large scale mixing while the followed slow decay reveals the small scale mixing. The temporal change of concentration probability functions conjectures the two sequential processes in the batch type mixing. An inactive column of water existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

  • PDF

A Study on the Mixing Characteristics in a Rushton Turbine Reactor by a Laser Induced Fluorescence Method (레이저 형광여기법(LIF)를 이용한 러쉬톤 터빈 교반기의 혼합특성에 관한 연구)

  • Jeong, Eun-Ho;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1145-1152
    • /
    • 2002
  • A non-intrusive Planar Laser-Induced Fluorescence(PLIF) technique was applied to study the turbulent mixing process in a Rushton turbine reactor. Instantaneous and ensemble averaged concentration fields was obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by a thin Nd:Yag laser sheet illuminating the whole center plane of the stirred tank. The gray level images captured by a 14-bit cooled CCD camera could be transformed to the local concentration values using a calibration matrix. The dye injection point was selected at the tank wall with three quarter. height (3/4H) from the tank bottom to observe the mixing characteristics in upper bulk flow region. There exist distinct two time scales: the rapid decay of mean concentration after the dye infusion reflects the large scale turbulent mixing while the fellowed slow decay reveals the small scale molecular mixing. The temporal change of concentration variance field conjectures the two sequential processes for the batch type mixing. An inactive column of water is existed above the impeller disk, in which the fluid rotates with the shaft but is isolated from the mean bulk flow.

Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks (온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션)

  • Noh, Yoorae;Park, Joonhong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.

A Study on the Effect of Filling Ratio on Sloshing Impact Pressure (적재율이 슬로싱 충격압력에 미치는 영향에 관한 연구)

  • Choi, Hu-In;Kwon, Sun-Hong;Park, Jung-Ho;Choi, Young-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.30-33
    • /
    • 2010
  • This study presents the effect of filling ratio on sloshing impact pressure. The experiment was done with three filling ratios of 20%, 70%, and 95% of the tank height. The input of the motion was regular excitation. The total number of sensors in use were 53. They were installed on tank top and tank wall. The maximum pressures and the average of one third highest impact pressures for the whole pressure sensors were investigated. The result shows clearly the location of sensors which are exposed to the high impact pressures for different filling ratios. The characteristics of the impact patterns for three filling ratios were also examined.

On the New Design of Liquid Dome Chair in Membrane Type LNG Carrier (멤브레인형 LNG선박의 리퀴드 돔 체어 구조개발)

  • Kim, Jeong-Hwan;Kim, Yooil
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.5
    • /
    • pp.361-367
    • /
    • 2017
  • A membrane type LNG cargo tank is equipped with a pump tower and a liquid dome for loading and unloading of LNG. However, the membrane running continuously on the tank wall to prevent leakage of LNG is interrupted by the liquid dome, hence care should be taken in the design of liquid dome and its substructures. In case of GTT NO96 membrane type cargo containment system, chair structure is arranged along the periphery of the liquid dome targeting to support the membrane which is exposed to the both hull girder and thermal load. This paper proposes a new and simple chair structure, which outperforms traditional design from productivity point of view maintaining same level of structural safety. Strength assessment on the new design was performed to guarantee the structural safety of the new design, which includes strength, fatigue and crack propagation analysis.

A Numerical Analysis of Transonic Flows in an Axisymmetric Main Nozzle of Air-Jet Loom (에어제트직기 주 노즐내 천음속 유동의 수치 해석적 연구)

  • Oh T. H.;Kim S. D.;Song D. J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.168-173
    • /
    • 1998
  • A numerical analysis of axisymetric backward facing step main nozzle flow in air jet loom has been accomplished. To obtain basic design data for an optimum main nozzle for an air-jet loom and to predict the transonic/supersonic flow, a characteristic based upwind flux difference splitting compressible Navier-Stokes method has been used. The wall static pressure of the main nozzle and the flow velocity changes in the nozzle tube were analyzed by changing air tank pressures and acceleration tube lengths. The flow inside the nozzle experiences double choking one at the needle tip and the other at the acceleration tube exit at tank pressures over $4kg_f/cm^2$. The tank pressure $P_t$ leading to the critical condition depends on the acceleration tube length; i.e, $P_t$ is higher for longer acceleration tubes. The $P_t$ value required to bring the acceleration tube exit to the critical condition is nearly constant regardless of acceleration tube length. The round needle tip shape might lead to less total pressure loss when compared with step shape.

  • PDF

Seismic control of concrete rectangular tanks subjected to bi-directional excitation using base isolation, considering fluid-structure-soil interaction

  • Mohammad Hossein Aghashiri;Shamsedin Hashemi;Mohammad Reza Kianoush
    • Structural Engineering and Mechanics
    • /
    • v.92 no.1
    • /
    • pp.25-52
    • /
    • 2024
  • In the current paper, the various responses of concrete rectangular liquid storage containers under seismic load, each isolated by a lead-rubber bearing subjected to bi-directional earthquake forces are investigated. A parametric study is conducted to investigate the effects of isolation period, yield strength of the isolator and the effects of soil-foundation interaction for non-isolated and base-isolated tanks located on different soil types. In most cases, the value of base shear, base moment, wall displacement and hydrodynamic pressure is reduced by the effect of the isolators whose effective frequency is within the appropriate range. The sloshing displacement is amplified due to seismic isolation of the tanks for both tall and shallow tank configurations. Also, it is found that the seismic isolation technique is more efficient for the more flexible tank. Studying various soil types indicates that, unlike the responses of non-isolated tanks which change drastically for different soil types, the responses of base-isolated structures are less affected. Finally, it is observed that the variation in structural responses is not only related to the superstructure configuration and bearings properties but also depends on the earthquake specifications.