극지용 쇄빙 유조선 개발 (Development of an Arctic Tanker Design)

  • 김현수;하문근;안당;전호환
    • 대한조선학회논문집
    • /
    • 제40권6호
    • /
    • pp.20-29
    • /
    • 2003
  • When Arctic offshore development in the 1970's first led to the consideration of ice capable tankers, there was a high level of uncertainty over design requirements for both safety and ship performance. Also here was a lack of reliable methods to evaluate design proposals. Since that time, improved understanding of the ice environment has raised the confidence of design specifications. Parallel developments have resulted in a suite of engineering tools for ship performance evaluation at the design stage Recent development of offshore and near shore oil and gas reserves in several countries together with economic studies of increased transportation through the Russian Arctic has newly introduced the interest in ice capable tanker design. in response, Samsung Heavy Industries (SHI) applied its experience in tanker design and construction to the design of a specialized tanker with ice capability. SHI produced two prototype hull designs for further study. The performance of both hulls and of the propellers was evaluated at the Institute for Marine Dynamics (IMD) in St. John's, Newfoundland This paper discusses the development of the design, describes the model experiments to determine performance and variations, and presents the results.

고지향 수중 통신을 위한 파라메트릭 어레이 트랜스듀서의 설계 및 개발 연구 (Design and Development Research of a Parametric Array Transducer for High Directional Underwater Communication)

  • 황용환;제엽;문원규
    • 한국음향학회지
    • /
    • 제34권2호
    • /
    • pp.117-129
    • /
    • 2015
  • 파라메트릭 어레이(parametric array)는 매질의 비선형성을 이용하여 고지향성 저주파를 발생시키는 현상이다. 발생된 저주파는 직접 발생된 1차 음파에 비해 음압이 상대적으로 매우 작다. 따라서 강력한 1차 음파를 지향성 있게 발생시킬 수 있는 트랜스듀서가 필수적으로 요구된다. 본 논문에서는 파라메트릭 어레이를 위한 음원으로써 다공진 트랜스듀서의 설계, 제작, 시험평가에 대해 연구하였다. 유닛 트랜스듀서 및 배열 트랜스듀서의 설계를 해석 모델에 근거하여 수행하였으며, 이 과정을 반복하여 최적의 트랜스듀서를 제작하였다. 제작된 배열 트랜스듀서는 6.3 m 거리에서 각각 189 dB, 190 dB의 1차 음파를 확인하였으며, 파라메트릭 어레이 현상을 이용하여 136 dB의 차주파수음 발생을 확인하였다. 차주파수음은 $12{\times}18{\times}10m$크기의 수조에서 15 kHz, $8^{\circ}$ half power beamwidth의 고지향성 저주파 특성을 가지고 있음을 확인하였다.

반구 곡면에 배열된 음향센서의 종합설계 학습 적용 연구 (A Study on Application of Integrated Design Learning of Acoustic Sensors Arranged on Hemispherical Surfaces)

  • 이종길
    • 실천공학교육논문지
    • /
    • 제10권1호
    • /
    • pp.41-47
    • /
    • 2018
  • 수중음향센서는 무인수중운동체에 장착되어 수중 정보를 탐지하고 처리하는 역할을 한다. 이러한 음향 센서 설계는 공학을 이해하고 적용하는데 매우 중요한 분야이다. 따라서 본 논문에서는 음향 센서를 단계별로 설계 및 제작하고 그 성능을 평가한 후 이러한 일련의 설계 절차와 단계 등을 종합설계 학습에 적용하기 위한 그 적합성을 연구하였다. 설문조사를 통하여 학습 적용 적합성을 분석하였으며 설문조사 결과 제시된 센서설계의 단계 및 방법 등은 종합 설계 프로젝트 내용으로 적합하며, 기술습득이 용이한 구조이고, 매우 흥미를 유발하는 설계 주제로 나타났고, 학습자의 높은 긍정적 반응을 나타내었다. 향후 본 설계 프로젝트를 종합설계에 적용하였을 때 높은 교육적 성과를 낼 수 있을 것으로 기대된다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.