• Title/Summary/Keyword: Tail-energy

Search Result 147, Processing Time 0.034 seconds

Dynamic Analysis on the Tail Gate System for Vehicle with the Energy Regenerative Brake of Hydraulic Driven Systems (유압 구동계 에너지 재생 브레이크를 적용한 자동차 테일게이트 개폐장치에 대한 동특성 해석)

  • Choi, Soon-Woo;Huh, Jun-Young
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 2010
  • The typical trunk lid system for vehicle is composed of a hinge having 4-bar link and gas lifter. Here, the energy regenerative brake of hydraulic driven systems is applied to the tail gate system for vehicle and removed the gas lifter. The new tail gate system is composed of a hydraulic pump by electric motor, a hydraulic motor, four check valves, an accumulator, a relief valve and a directional control valve. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action. The capacity selection method of accumulator by mathematical model is based upon trial and error approach and computer simulation by AMEsim software is carried out.

  • PDF

Combustion Characteristics of HCNG Burner System with Tail Gas Addition (HCNG용 버너시스템에서 Tail Gas 첨가 시 연소특성)

  • Han, J.O.;Lee, J.S.;Kim, H.T.;Kim, S.M.;Lee, Y.C.;Kim, Y.C.;Hong, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.2
    • /
    • pp.36-39
    • /
    • 2015
  • The combustion characteristics of metal fiber burner fueled natural gas with tail gas produced from reforming process were analyzed on the point of flame stability and excess air conditions. Also, it was analyzed the effect of energy efficiency improvement due to decrease the fuel input in reforming system by using residue gases. As a results, it was confirmed that tail gas including hydrogen, CO and $CO_2$ could be directly injected without any change of air control system in natural gas burner and also energy efficiency was increased up to 30% maintained stable combustion.

Implementation of Wind Power System and Development of a Automatic Tail Safety Controller (풍력발전시스템의 강풍제어기 개발 및 시스템 구성)

  • Choi, Jung-Hoon;Moon, Chae-Joo;Jang, Yung-Hak;Lee, Hyun-Ju
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.424-428
    • /
    • 2004
  • A wind turbine system converts wind energy into electric energy, the system operated under normal environmental conditions. In case of particular turbulent wind flow such as typhoon, hurricane etc, the control of a blade used to a yaw control and a pitch control method. A small wind turbine has not a speed control system to only a manual tail safety brake. This paper shows a automatic tail safety brake controller based on feedback control using wind velocity. The controller composed of wired motor, relay system, steel wired motor him down a perpendicular to wind flow and then the blade speed reduced high to zero. The operation of automatic tail safety controller verified by manual test.

  • PDF

ANALYSIS OF CHARGE COLLECTION EFFICIENCY FOR A PLANAR CdZnTe DETECTOR

  • Kim, Kyung-O;Kim, Jong-Kyung;Ha, Jang-Ho;Kim, Soon-Young
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.723-728
    • /
    • 2009
  • The response property of the CZT detector ($5{\times}5{\times}5\;mm^3$), widely used in photon spectroscopy, was evaluated by considering the charge collection efficiency, which depends on the interaction position of incident radiation, A quantitative analysis of the energy spectra obtained from the CZT detector was also performed to investigate the tail effect at the low energy side of the full energy peak. The collection efficiency of electrons and holes to the two electrodes (i.e., cathode and anode) was calculated from the Hecht equation, and radiation transport analysis was performed by two Monte Carlo codes, Geant4 and MCNPX. The radiation source was assumed to be 59.5 keV gamma rays emitted from a $^{241}Am$ source into the cathode surface of this detector, and the detector was assumed to be biased to 500 V between the two electrodes. Through the comparison of the results between the Geant4 calculation considering the charge collection efficiency and the ideal case from MCNPX, an pronounced difference of 4 keV was found in the full energy peak position. The tail effect at the low energy side of the full energy peak was confirmed to be caused by the collection efficiency of electrons and holes. In more detail, it was shown that the tail height caused by the charge collection efficiency went up to 1000 times the pulse height in the same energy bin at the calculation without considering the charge collection efficiency. It is, therefore, apparent that research considering the charge collection efficiency is necessary in order to properly analyze the characteristics of CZT detectors.

Tail Electron Hydrodynamic Model for Consisten Modeling of Impact Ionization and Injection into Gate Oxide by Hot Electrons (고온전자의 충돌 이온화 및 게이트 산화막 주입 모델링을 위한 Tail 전자 Hydrodynamic 모델)

  • 안재경;박영준;민홍식
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.100-109
    • /
    • 1995
  • A new Hydrodynamic model for the high energy tail electrons(Tail Electron Hydrodynamic Model : TEHD) is developed using the moment method. The Monte Carlo method is applied to a $n^{+}-n^{-}-n^{+}$ device to calibrate the TEHD equations. the discretization method and numerical procedures are explained. New models for the impact ionization and injection into the gate oxide using the tail electron density are proposed. The simulated results of the impact ionization rate for a $n^{+}-n^{-}-n^{+}$ device and MOSFET devices, and the gate injection experiment are shown to give good agreement with the Monte Carlo simulation and the measurements.

  • PDF

Low Latency Encoding Algorithm for Duo-Binary Turbo Codes with Tail Biting Trellises (이중 입력 터보 코드를 위한 저지연 부호화 알고리즘)

  • Park, Sook-Min;Kwak, Jae-Young;Lee, Kwy-Ro
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.47-51
    • /
    • 2009
  • The low latency encoder for high data rate duo-binary turbo codes with tail biting trellises is considered. Encoder hardware architecture is proposed using inherent encoding property of duo-binary turbo codes. And we showed that half of execution time as well as the energy can be reduced with the proposed architecture.

Detection of Irradiated Grains Using the DNA ‘Comet Assay’ (DNA ‘Comet Assay’를 이용한 곡류의 방사선 조사 여부 확인)

  • Kim, Choong-Ki;Yang, Jae-Seung;Lee, Hae-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.906-911
    • /
    • 1999
  • This study was to determine whether DNA 'Comet Assay' can be applied to the detection of grains irradiated with low doses of Co-60 gamma radiation. Sesame, perilla, wheat, barley and rice were exposed to different doses of 0.1, 0.3, 0.5, 0.7 and 1.0 kGy. The cells isolated from the samples were embedded in a agarose gel on a microscope slide, lysed in lysis solution, and subjected to electrophoresis. DNA and its fragments migrated in the gel produced the characteristic pattern of DNA comet, of which the tail length was measured in a microscope. All the samples irradiated at 0.3 kGy and higher were applicable to detect post-irradiation by the tail length of their comets. Irradiated samples showed comets with long tails and their tail length increased with the dose, while unirradiated samples showed no or very short tails. Especially, sesame, perilla and wheat irradiated at 0.1 kGy could be distinguished from unirradiated samples by visual inspection of the slide in a microscope. Thus, DNA 'Comet Assay' might be applied to the detection of irradiated grains as a simple, inexpensive and rapid screening test.

  • PDF

Non-iterative pulse tail extrapolation algorithms for correcting nuclear pulse pile-up

  • Mohammad-Reza Mohammadian-Behbahani
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4350-4356
    • /
    • 2023
  • Radiation detection systems working at high count rates suffer from the overlapping of their output electric pulses, known as pulse pile-up phenomenon, resulting in spectrum distortion and degradation of the energy resolution. Pulse tail extrapolation is a pile-up correction method which tries to restore the shifted baseline of a piled-up pulse by extrapolating the overlapped part of its preceding pulse. This needs a mathematical model which is almost always nonlinear, fitted usually by a nonlinear least squares (NLS) technique. NLS is an iterative, potentially time-consuming method. The main idea of the present study is to replace the NLS technique by an integration-based non-iterative method (NIM) for pulse tail extrapolation by an exponential model. The idea of linear extrapolation, as another non-iterative method, is also investigated. Analysis of experimental data of a NaI(Tl) radiation detector shows that the proposed non-iterative method is able to provide a corrected spectrum quite similar with the NLS method, with a dramatically reduced computation time and complexity of the algorithm. The linear extrapolation approach suffers from a poor energy resolution and throughput rate in comparison with NIM and NLS techniques, but provides the shortest computation time.

The Ejector Design and Test for 5kW MCFC System (5kW 용융탄산염 연료전지(MCFC) 이젝터 설계 및 시험)

  • Kim, Beom-Joo;Kim, Do-Hyeong;Lee, Jung-Hyun;Lee, Sung-Yoon;Kim, Jin-Yoel;Kang, Seung-Won;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • An ejector is a machine utilized for mixing fluid, maintaining a vacuum, and transporting fluid. The Ejector enhances system efficiency, are easily operated, have a mechnically simple structure, and do not require a power supply. Because of these advantages, the ejector has been applied to a variety of industrial fields such as refrigerators, power plants and oil plants. In this work, an ejector was used to safely recycle anode tail gas in a 5 kW Molten Carbonate Fuel Cell system at KEPRI(Korea Electric Power Research Institute). In this system, the ejector is placed at mixing point between the anode tail gas and the cathode tail gas or the fresh air. Commercial ejectors are not designed for the actual operating conditions for our fuel cell system. A new ejector was therefore designed for use beyond conventional operating limits. In this study, the entrainment ratio is measured according to the diametrical ratio of nozzle to throat in the designed ejector. This helps to define important criteria of ejectors for MCFC recycling.

Changes of DNA Fragmentation by Irradiation Doses and Storage in Gamma-Irradiated Fruits (감마선 조사 과일류에서 조사선량과 저장기간에 따른 DNA Fragmentation의 변화)

  • Kim, Sang-Mi;Park, Eun-Ju;Yang, Jae-Seung;Kang, Myung-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.4
    • /
    • pp.594-598
    • /
    • 2002
  • The changes in DNA damage were investigated during storage after irradiation. Kiwi, orange and pear were irradiated at 0.1, 0.3, 0.5, 0.7 and 1.0 kGy and stored for 3 months at 4$^{\circ}C$. The comet assay was applied to the sample seeds alt the beginning of irradiation and at the end of storage. Seeds were isolated and crushed, and the suspended cells were embedded in an agarose layer. After lysis of the cells, they were electrophoresed for 2 min and then stained. DNA fragmentation in seeds caused by irradiation was quantified as tail length and tail moment (tail length $\times$ % DNA in tail) by comet image analyzing system. Immediately after irradiation, the differences in tail length between unirradiated and irradiated fruit seeds were significant (p<0.05) in kiwi, orange and pear seeds. With in-creasing the irradiation doses, statistically significant longer extension of the DNA from the nucleus toward anode was observed. The results represented as tail moment showed similar tendency to those of tail length, but tile latter parameter was more sensitive than the former. Similarly even 3 months after irradiation, all the irradiated fruit seeds significantly showed longer tail length than the unirradiated controls. These results indicate that the comet assay could be one of the simple methods of detecting irradiated fruit seeds. Moreover, the method could detect DNA damage even after 3 months after irradiation.