• Title/Summary/Keyword: Tadalafil

Search Result 16, Processing Time 0.034 seconds

Isolation and Identification of an Unauthorized Tadalafil Analogue in a Commercial Functional Food (시판 기능성식품으로부터의 타다라필 유도체 부정첨가물질의 분리 및 구조규명)

  • Baek, Du-Jong
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.240-243
    • /
    • 2010
  • High-performance liquid chromatography (HPLC) screening method revealed that a propolis product marketed as a functional food contained an undeclared substance similar to tadalafil, the active ingredient of the prescription drug Cialis$^{(R)}$ approved for the treatment of male erectile dysfunction. In order to identify the illegal additive, the propolis product was extracted with methylene chloride, and the extract was purified further using semipreparative HPLC. The chemical structure of the isolated substance was elucidated based on IR, LC/MS-ESI, and $^1H$- and $^{13}C$-NMR spectroscopy, which showed the characteristics similar to tadalafil. The only difference was the substitution of the methyl group at the piperazinedione ring of tadalafil to the amino group of the identified illegal additive.

A Case of Acute Pulmonary Thromboembolism after Taking Tadalafil

  • Lee, Jinwoo;Kwon, Ji Hyun;Lee, Chang-Hoon;Lee, Sang-Min;Yim, Jae-Joon;Yoo, Chuy-Gyu;Kim, Young Whan;Han, Sung Koo;Park, Young Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.4
    • /
    • pp.231-233
    • /
    • 2012
  • Tadalafil is a phosphodiesterase-5 inhibitor (PDE5I), which is widely used to treat erectile dysfunction. Although PDE5Is have excellent safety profiles, and most of the side effects are mild, rare serious adverse events have been reported in association with PDE5Is. Thrombosis is one of those events, and a few previous reports have suggested the association of PDE5Is with thrombosis. We report the case of a 61-year-old male who developed pulmonary embolism combined with pulmonary infarction directly after taking tadalafil. Both the patient and the physician suspected tadalafil as the culprit drug, as the patient was in an otherwise healthy condition. However, after extensive evaluation, we noticed that factor VIII levels were elevated. Prior reports suggesting the association between thrombosis and PDEIs either lack complete information on coagulation factors, or show inconsistencies in their results. Physicians should operate caution prior to accepting the diagnosis of adverse drug reaction.

Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods (식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구)

  • Jang, Jae-Hee;Park, Kun-Sang;Park, Hye-Kyung;Koo, Yong-Eui;Choi, Youn-Ju;Hwang, In-Kyung;Kim, Dai-Byung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.195-201
    • /
    • 2003
  • An easily available, simultaneous identification/determination procedure for sildenafil, homosildenafil, tadalafil, vardenafil in adulterated health related foods was established by using a combination of three different analytical methods; thin layer chromatography(TLC), liquied chromatography-mass spectrometry (LC/MS) and high-performance liquied chromatography (HPLC)/photo-diode-array detector. The sample solution for TLC was applied to silica gel 60 $F_{254}$ plates with ethylacetate/acetonitrile/25%ammonia (90:10:5) as a developing solvent. Spots were located under UV radiation at 254 nm and dragendolfs reagent. Mass spectra of the compounds by LC/MS were investigated with electrospray ionization (ESI) interface, under positive ion mode. The HPLC analysis was performed on a column of capcell pack $C_{18}$ (UG120, 4.6${\times}$250mm I.D. 5 ${\mu}$m)with 0.1% sodium 1-hexansulfonate (in 0.1% phosphoric acid)/acetnitrile (73:27) as a mobile phase, and effluent was minitored with a photo-diode-applied to commercial foods, Sildenafil content was inthe range of 0.4mg/g~360.9 mg/g from 7 out of 35 samples. Homosildenafil content was in the range of 2.2 mg/g~336.0 mg/g from 7 out of 35 samples. Tadalafil content was 429.3 mg/g, 9.6 mg/500 mg from 2 out of 35 samples. The procedure described here is available for the screening of sildenafil, homosildenafil, tadalafil, vardenafil.

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

Determining Anti-impotence drug-like compounds in Food (식품 중 발기부전치료제 및 유사물질의 분석)

  • Choi, Dongmi;Im, Mooheg;Lee, Kyungjin;Kwon, Kwangil;Jeong, Jiyoon;Park, Gunsang;Hong, Mooki;Lee, Chulwon
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.520-526
    • /
    • 2004
  • To determine 6 anti-impotence drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil and hongdenafil in food, simultaneously, high performance liquid chromatography was applied. In the case of solid sample, it was extracted in organic solvents after homogenizing with mortar and pestle. Whereas liquid sample was just diluted in water and then extracted in organic solvents. Maximum lengths of UV for targets have been identified on photodiode array spectra. As results, vardenafil, hongdenafil, hydroxyhomosildenafil, sildenafil, homosildenafil, and tadalafil were eluted in order using $C_{18}$ column in acetonitrile containing phosphoric acid as the mobile phase. The maximum wavelength (${\lambda}_{max}$) was 216 nm for vardenafil, 233 and 282 nm for hongdenafil, 222 and 293 nm for hydroxyhomosildenafil, sildenafil and homosildenafil, and 284 nm for tadalafil. The overall recoveries were ranged from 95% to 109% and the limit of detection was about 0.04 mg/kg at signal/noise>3. Levels of targets in the selected food samples were 1.7 (hongdenafil) ~ 63 (tadalafil) mg/one dose.

Monitoring of Fake Anti-impotence Drugs (불법유통 발기부전치료제 유사제품 조사 연구)

  • Kim, Beom-Ho;Jeon, Jong-Sup;Lee, Myung-Jin;Park, Eun-Mi;Cho, Sang-Hun;Kwon, Hye-Jung;Yoon, Mi-Hye;Lee, Jong-Bok
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.92-98
    • /
    • 2014
  • The safety of fake anti-impotence drugs (fake Viagra : 26 samples, fake Cialis : 25 samples) distributed in Gyeonggi province was studied by monitoring the concentrations of anti-impotence pharmaceutical ingredient and their analogues. The concentrations of anti-impotence pharmaceutical ingredient 4 specis and their analogues 17 specis were estimated using by HPLC/PDA, LC-MS/MS. The range of concentration of sildenafil in fake viagra was 40~199 mg/tablet, among them the portion of the concentrations of sildenafil over 150 mg/tablet exceeded 65%. 3 cases in tested samples contained sildenafil and tadalafil. The range of concentration of sildenafil in fake cialis was 102~249 mg/tablet, among them the portion of the concentrations of sildenafil over 150 mg/tablet exceeded 88%. One case in tested samples contained demethylhongdenafil (90 mg/tablet). These results indicate that there were many fake anti-impotence drug contained high level of anti-impotence pharmaceutical ingredients, a sustainable monitoring and the blocked distribution of fake anti-impotence drugs recommended.

Monitoring of Anti-impotence Drugs and Their Analogues in Food (식품 중의 발기부전치료제 및 유사물질 모니터링)

  • Lee, Hyun-Sook;Lee, Joon-Goo;Kim, Jin-Chul;Oh, Jae-Ho;Jang, Young-Mi;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.675-682
    • /
    • 2011
  • This study was conducted to monitor the concentrations of 24 anti-impotence drugs and their analogues in various foods and dietary supplements, with the aim of ensuring the safety of the foods and supplements. The measurements were done in 226 samples using high performance liquid chromatography/photodiode array detector (HPLC/PDA) and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Five male sexual function enhancing products have been detected as follows: acethylvardenafil (21,476 mg/kg; 15 mg/capsule from one sample), sildenafil (52,778 mg/kg, 29 mg/capsule in one sample; 71,535 mg/kg, 48 mg/capsule in one sample), and tadalafil (9,772-55,545 mg/kg, 6-33 mg/capsule in four samples). A sustainable monitoring of anti-impotence drugs and their analogues in various foods and dietary supplement is recommended.

Analysis of erectile dysfunction drugs and their analogues in counterfeit drugs and herbal medicines by LC-ESI-MS/MS

  • Lee, Ji Hyun;Jeong, Ji Hye;Park, Hyoung-Joon;Do, Jung Ah;Heo, Seok;Cho, Sooyeul;Yoon, Chang-Yong
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.155-161
    • /
    • 2016
  • Distribution of various illegal or counterfeit drugs of seven approved erectile dysfunction drugs and their analogues has been increased, causing health problems such as cardiovascular disorder, tachycardia, headache, or vision disturbance. We used liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) to determine the erectile dysfunction drugs and their analogues in various counterfeit drugs. Eleven erectile dysfunction drugs and their analogues were detected, with sildenafil and its analogues being the most counterfeited compounds (73.8 %), followed by tadalafil and its analogues (25.4 %). The limits of detection (LOD) and the limits of quantitation (LOQ) of liquid-type and solid-type negative samples ranged from 0.1 to 3.3 ng/mL or ng/g and from 0.3 to 10.0 ng/mL or ng/g, respectively. The recoveries ranged from 84.3 to 112.3 % and 83.2 to 110.2 %, respectively. The contents of sildenafil and tadalafil in the various counterfeit drugs ranged from 21.0 to 947.5 mg/g and from 0.2 to 170.2 mg/g, respectively.

Studies on the Analysis of Anti-impotent Drugs

  • Kang, Chan-Sun;Choi, Bo-Kyung;Kim, Hye-Soo;Choi, Myoeng-Sin;Hong, Chong-Hui;Ko, Yong-Seok;Kim, Sang-Hyun;Jang, Seung-Jae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.397.2-397.2
    • /
    • 2002
  • Sildenafil citrate(SC. Viagra(equation omitted)) is the oral treatment for erectile dysfunction. Vardenafil hydrochloride. tadalafil and modified sildenafil have anti-impotent effect and have possibility to be used illegally. The aim of this study was to set up simultaneous determination method of anti-impotent drugs using TLC and HPLC. The anti-impotent drugs were extracted with 50% methanol and then diluted with mobile phase for HPLC and also extracted with developing solvents as sample solutions for TLC. (omitted)

  • PDF

Identification and evaluation of fragmentation pathways of PDE-5 inhibitor analogues using LC-QTOF-MS (LC-QTOF-MS를 이용한 발기부전치료제 유사물질의 fragmentation pathway 분석)

  • Do, Jung-Ah;Noh, Eunyoung;Yoon, Soon-Byung;Park, Hyoung-Joon;Cho, Sooyeul;Park, Sung-Kwan;Yoon, Chang-Yong
    • Analytical Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.278-287
    • /
    • 2015
  • Phosphodiesterase type 5 inhibitors (PDE-5 inhibitors) are used in the treatment of erectile dysfunction. In recent years, a number of reports have been conducted on dietary supplements contaminated with PDE-5 analogues. In this study, 58 analogues of PDE-5 inhibitors were sorted into five groups: tadalafil, sildenafil, hongdenafil, vardenafil, and other analogues. These analogues were then evaluated using a liquid chromatography-quadrupole-time of flight mass spectrometry (LC-QTOF-MS) electrospray ionization mass method. Each compound has a unique fragmentation ion, which can be easily analyzed qualitatively. The fragmentation pathways of the analogues were elucidated based on the QTOF-MS and MS/MS data. Common ions were confirmed for each group by analyzing the structural characteristics and fragmentation pathways. Specifically, common ions were observed at m/z 169.08 and 135.04 (tadalafil analogues), m/z 311.15 and 283.12 (sildenafil analogues and hongdenafil analogues), and m/z 312.16 and 151.09 (vardenafil analogues). The advantage of this method is that the structure of unknown components can be determined by interpreting the product ions. Hence, the developed method can be used for the identification of unknown compounds. Fragmentation pathways may also aid in the detection and identification of PDE-5 inhibitor analogues.