• Title/Summary/Keyword: Table object distance

Search Result 15, Processing Time 0.026 seconds

Method of Horizontal-Moving Stereoscopic Camera Auto Control Out of Center Position (비중심축상 물체 위치에 따른 수평이동방식 입체카메라의 자동제어 방법)

  • Im, Yeong-Tae;Kim, Nam;Gwon, Gi-Cheol;Jeon, Seok-Hui
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.247-248
    • /
    • 2007
  • Control convergence of Horizontal-Moving stereoscopic camera is demonstrated with object distance. To acquire object distance calculated vergence angle is needed. Compare calculated vergence angle with look up table, processing time of auto control is reduce.

  • PDF

A Study on the Object Angle Inference in a Sonar Sensor Array System (초음파센서 배열 시스템에서 물체의 각도 추론에 관한 연구)

  • 나승유;박민상
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.271-274
    • /
    • 1998
  • Ultrasonic sensors are becoming indispensable components in every sector of automation equipments due to many advantages. But the main purposes of the noncontact sensing device are rather narrowly confined within object detection and distance measurement. To widen the realm of the applications to object recognition, ultrasonic sensors need to improve the recognition resolution to a certain amount. To resolve the problem of spatial resolution restriction, an increased number of the sensors in the forms of a linear array or 2-dimensional array of the sensor has been used. Also better resolution has been obtained by shifting the array in several steps using mechanical actuators. For an object recognition using ultrasonic sensors, measurements of distance, shift, oblique angle in certain ranges should be obtained. But a little attention has been paid to the measurement of angles. In this paper we propose a practical method for an object angular value detection in addition to distance measurement in ultrasonic sensor array system with little additional hardware burden. Using the established measurement look-up table for the variations of distance, shift, angle and transmitter voltages for each sensor characteristics, a set of different return echo signals for adjacent receivers are processed to provide enhanced angular value reading for an object.

  • PDF

Study on the Accuracy of Vessel Measurement According to Table Object Distance Changes (혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.435-440
    • /
    • 2019
  • This is to study the accuracy of the actual size according to the TOD(table object distance; TOD) change when measuring blood vessels using angiography equipment, and to help the optimal selection of the device used accordingly. Balls similar to the size of common vessels were calibrated with TOD using 30 mm, 20 mm, 10 mm, 5 mm and acrylic phantoms, catheter calibration from 0 cm to 10 cm, 20 cm and 30 cm, respectively. It was measured whether there was a change in the measured value according to the change. The equipment used was GE Innova 3131 IQ equipment, and the image reconstruction method was GE AW4.7 post processing program. Two radiotechnologists were scanned three times by catheter calibration method and 3DRA(3dimension rotational angiography; 3DRA) volume rendering method. The independent sample T-test showed 0.981 (p> 0.05) to verify the significance between the two observers. As a result, in case of catheter calibration, the error rate at TOD 0 mm and 10 mm is within ± 10%, but when the TOD is changed to 20 mm and 50 mm respectively, the tolerance is ± 10% except for 30 mm ball exceeded. On the other hand, 3DRA was included within the tolerance range of ± 10% overall even when the TOD was changed from 0 mm to 50 mm. In the catheter calibration method, the larger the TOD, the larger the error range, and the 3DRA method was able to measure vascular vessels accurately close to the actual measurement without any consideration of the TOD.

Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D (단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구)

  • Seo, Jeong-Beom;Kim, Dong-Hyeon;Lee, Jeong-Beom
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

Development of 3D Scanner Based on Laser Structured-light Image (레이저 구조광 영상기반 3차원 스캐너 개발)

  • Ko, Young-Jun;Yi, Soo-Yeong;Lee, Jun-O
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.3
    • /
    • pp.186-191
    • /
    • 2016
  • This paper addresses the development of 3D data acquisition system (3D scanner) based laser structured-light image. The 3D scanner consists of a stripe laser generator, a conventional camera, and a rotation table. The stripe laser onto an object has distortion according to 3D shape of an object. By analyzing the distortion of the laser stripe in a camera image, the scanner obtains a group of 3D point data of the object. A simple semiconductor stripe laser diode is adopted instead of an expensive LCD projector for complex structured-light pattern. The camera has an optical filter to remove illumination noise and improve the performance of the distance measurement. Experimental results show the 3D data acquisition performance of the scanner with less than 0.2mm measurement error in 2 minutes. It is possible to reconstruct a 3D shape of an object and to reproduce the object by a commercially available 3D printer.

Changes of Various Balls Velocity under the Different Surface Conditions after Impact (충돌 후 지면 조건에 따른 다양한 볼의 속도변화에 관한 연구)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.91-97
    • /
    • 2007
  • The purpose of this study was to investigate the changes of various balls velocity under the different surface conditions after impact. For this study, four different balls were used which are golf ball, tang-tang ball, table tennis ball, and iron ball. And two different types of ground conditions were used which are artificial grass green and glass green. Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. To transfer the same amount of kinetic energy to the ball, pendulum putting machine was used. Analyzing the process of impact and the ball movement, a putter was digitized the whole movement but the ball was digizited within the 50cm movement. Velocities were calculated by the first central difference method(Hamill & Knutzen, 1995). Putter head velocities were about 112.2cm/s-116.2cm/s at impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Table tennis ball recorded higher ball velocities than the other ball velocities and iron ball recorded the lowest ball velocity in this group. But Table tennis ball was influenced with the frictional force and immediately was decreased at the artificial grass green condition. If an object is received the kinetic energy under the static condition(v=0cm/s), the object recorded the maximum velocity shortly after the impact and then decreased the velocity because of the frictional force. The ball distance from the start position to the peak velocity position is about 6cm-10cm under the 112.2cm/s-116.2cm/s putting velocity with putter. 0.25 seconds later after impact balls were placed 40cm distance from the original position except iron ball. In this study, ball moving distances were too short therefore it was not possible to investigate the reactions after the translational force is disappeared. Rotational force would play a major role at the end of the ball movement. Future study must accept two things. One is long distance movement of ball and the other is balanced ground. Three-piece ball is a good item to investigate the golf ball movement on the different surface conditions.

Locally Initiating Line-Based Object Association in Large Scale Multiple Cameras Environment

  • Cho, Shung-Han;Nam, Yun-Young;Hong, Sang-Jin;Cho, We-Duke
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.3
    • /
    • pp.358-379
    • /
    • 2010
  • Multiple object association is an important capability in visual surveillance system with multiple cameras. In this paper, we introduce locally initiating line-based object association with the parallel projection camera model, which can be applicable to the situation without the common (ground) plane. The parallel projection camera model supports the camera movement (i.e. panning, tilting and zooming) by using the simple table based compensation for non-ideal camera parameters. We propose the threshold distance based homographic line generation algorithm. This takes account of uncertain parameters such as transformation error, height uncertainty of objects and synchronization issue between cameras. Thus, the proposed algorithm associates multiple objects on demand in the surveillance system where the camera movement dynamically changes. We verify the proposed method with actual image frames. Finally, we discuss the strategy to improve the association performance by using the temporal and spatial redundancy.

Voxel-Based Thickness Analysis of Intricate Objects

  • Subburaj, K.;Patil, Sandeep;Ravi, B.
    • International Journal of CAD/CAM
    • /
    • v.6 no.1
    • /
    • pp.105-115
    • /
    • 2006
  • Thickness is a commonly used parameter in product design and manufacture. Its intuitive definition as the smallest dimension of a cross-section or the minimum distance between two opposite surfaces is ambiguous for intricate solids, and there is very little reported work in automatic computation of thickness. We present three generic definitions of thickness: interior thickness of points inside an object, exterior thickness for points on the object surface, and radiographic thickness along a view direction. Methods for computing and displaying the respective thickness values are also presented. The internal thickness distribution is obtained by peeling or successive skin removal, eventually revealing the object skeleton (similar to medial axis transformation). Another method involves radiographic scanning along a viewing direction, with minimum, maximum and total thickness options, displayed on the surface of the object. The algorithms have been implemented using an efficient voxel based representation that can handle up to one billion voxels (1000 per axis), coupled with a near-real time display scheme that uses a look-up table based on voxel neighborhood configurations. Three different types of intricate objects: industrial (press cylinder casting), sculpture (Ganesha idol), and medical (pelvic bone) were used for successfully testing the algorithms. The results are found to be useful for early evaluation of manufacturability and other lifecycle considerations.

The Recognition of Occluded 2-D Objects Using the String Matching and Hash Retrieval Algorithm (스트링 매칭과 해시 검색을 이용한 겹쳐진 이차원 물체의 인식)

  • Kim, Kwan-Dong;Lee, Ji-Yong;Lee, Byeong-Gon;Ahn, Jae-Hyeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.7
    • /
    • pp.1923-1932
    • /
    • 1998
  • This paper deals with a 2-D objects recognition algorithm. And in this paper, we present an algorithm which can reduce the computation time in model retrieval by means of hashing technique instead of using the binary~tree method. In this paper, we treat an object boundary as a string of structural units and use an attributed string matching algorithm to compute similarity measure between two strings. We select from the privileged strings a privileged string wIth mmimal eccentricity. This privileged string is treated as the reference string. And thell we wllstructed hash table using the distance between privileged string and the reference string as a key value. Once the database of all model strings is built, the recognition proceeds by segmenting the scene into a polygonal approximation. The distance between privileged string extracted from the scene and the reference string is used for model hypothesis rerieval from the table. As a result of the computer simulation, the proposed method can recognize objects only computing, the distance 2-3tiems, while previous method should compute the distance 8-10 times for model retrieval.

  • PDF

Design of 8 Channel Insertional pTx Array Coil for 3T Body Imaging (8 채널 삽입형 3T Body pTx Array 코일 설계)

  • Kim, Young Beom;Ryu, Yeunchul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.546-550
    • /
    • 2014
  • In this research, we report all the elements are placed in the space above the patient table as a transmit coil to give optimized B1+ field for the body object. Through the simulations, we compared upper-and-lower parts combined 8 channel Tx array to upper only 8 channel Tx array and showed the utilities of B1+ shimming in multi-channel Tx body imaging at 3T. Half-cylinder shaped upper array shows weak B1+ field area around back of patient without B1+ shimming. After B1+ shimming, highly induced SAR places occurred in the arm region due to the close distance to the both end elements which were driven by very high RF current to enhance B1+ in back area. The proposed upper and lower combined array provides an enhanced homogeneous B1+ field in large ROI imaging as a result of shimming over the body size phantom. Through this research we proved the usefulness of the proposed insertional upper and lower parts combined transmit array for 3T body imaging.