• Title/Summary/Keyword: TYPE 1

Search Result 49,065, Processing Time 0.057 seconds

Studies on the Development of Easy-checking Thermometer to Detect the Diseased Domestic Animals with fever (가축 질병 이환상태의 확인을 위한 간이 체온계 개발에 관한 연구)

  • 김용준;한경호;이창민;홍유미
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.28-36
    • /
    • 2002
  • These studies were carried out to develop some easy-checking thermometers instead of taking temperature of ectum for the farmers to detect easily a diseased animal with fever. Thermometers such as pincher-type, hood-type, raser-type, stick-type, and wrap-type were devised for the experiments. The experimental animals were cattle, horse, swine, aprine, and canine. Temperature-taking parts of the body were ear, shoulder, axilla, gluteal part, and coccygeal part according o the devised thermometer. Rectal temperature was taken at the same time for the comparison of temperature between rectum nd the certain part. The difference of temperature between rectum and shoulder part using eraser-type thermometer for the domestic animals were $3.37^{\circ}C$ for cattle, $1.94^{\circ}C$ for horses, $2.04^{\circ}C$ for swine, $1.27^{\circ}C$ for caprine, $0.9^{\circ}C$ for canine. The difference of temperature between rectum and gluteal part using eraser-type thermometer for domestic animals were $3.46^{\circ}C$ for cattle, $1.98^{\circ}C$ for horses, $2.22^{\circ}C$ for swine, and $1.1^{\circ}C$ for canine. The difference of intra-individual temperature taken by eraser-type thermometer of shoulder and gluteal part were 0.3 and $0.8^{\circ}C$ for cattle, 0.7 and $1.1^{\circ}C$ for horses, 0.6 and $0.7^{\circ}C$ for swine, 0.9 and $1.1^{\circ}C$ for canine. The difference of temperature between rectum and shoulder part taken by hood-type thermometer for cattle was $3.93^{\circ}C$ and the difference of intra-individual temperature was $0.8^{\circ}C$. The difference of temperature between rectum and gluteal part taken by stick-type thermometer for cattle was $3.7^{\circ}C$ and the difference of intra-individual temperature was $0.8^{\circ}C$. The other types of thermometers than the above three were not proved to be reliable to detect temperature of domestic animals. It was concluded that hood-type, stick-type and eraser-type thermometers are recommendable devices of thermometer to detect easily the status of body temperature and that the eraser-type was proved to be a practical one of the thermometers used in this study.

Characteristics of 'ㄷ' type MSA Antenna for Frequency Shift (주파수 시프트용 'ㄷ'자형 MSA 안테나 특성)

  • Park, Sung-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.235-238
    • /
    • 2013
  • In this paper, ㄷ-type MSA for the QMSA structure is proposed. Transformed ㄷ-type MSA is stacked three dielectrics. ㄷ-type MSA structure was load upper & lower surface of the dielectric radiating patch and the ground turn-up left right capacity between parallel plates and radiating patch. Between the dielectric permittivity of the dielectric insert by 2.55 by varing the frequency was shifted. Designed ㄷ-type MSA sturcture of L1 was varied up to 1mm~22mm and frequency was shifted from 3.65GHz~3.84GHz. Also Designed ㄷ-type MSA was measured 1.95dBi maximum gain and bandwidth of 1.61 to 3.64%.

A Study on Subjective Recognition of One Authorized District for Large Retailers' Home Meal Replacement PB Products (대형유통업체 가정간편식 PB상품에 대한 1인가구의 주관적 인식에 관한 연구)

  • Kim, Dong-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.309-318
    • /
    • 2018
  • In this study, we investigated subjective perceptions of one retailer's PB products for large retailers by applying the Q methodology to examine subjective trends of consumers who purchased and experienced PB products at home. In this study, we examine how HMR-type PB products developed and released by large retailers according to the demographically changing social structure represent the meaning and subjective acceptance of PB products in a single licensee through Q methodological studies. The purpose of this paper is to propose various direction and improvement plan of food product development and release for one license of large distribution company in the future. Based on these research problems, five types of type analysis results were derived. Specifically, the first type (N = 5): Brand image trust type, the second type (N = 5): NB product preference type, the third type(N = 2): Easy cooking preference type, and fourth type (N = 2): Pursuing taste for price type and fifth type (N = 2): Quantitative pursuit for price type.

Characteristics and Clinical Course of Fusiform Middle Cerebral Artery Aneurysms According to Location, Size, and Configuration

  • Seo, Dongwook;Lee, Si Un;Oh, Chang Wan;Kwon, O-Ki;Ban, Seung Pil;Kim, Tackeun;Byoun, Hyoung Soo;Kim, Young Deok;Lee, Yongjae;Won, Yu Deok;Bang, Jae Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.649-660
    • /
    • 2019
  • Objective : To analyze the angiographic features and clinical course, including treatment outcomes and the natural course, of fusiform middle cerebral artery aneurysms (FMCAAs) according to their location, size, and configuration. Methods : We reviewed the literature on adult cases of FMCAAs published from 1980 to 2018; from 25 papers, 112 FMCAA cases, for which the location, size, and configuration could be identified, were included in this study. Additionally, 33 FMCAA cases in our hospital were included, from which 16 were assigned to the observation group. Thus, a total of 145 adult FMCAA cases were included. We classified the FMCAAs according to their location (l-type 1, beginning from prebifurcation; l-type 2, beginning from bifurcation; l-type 3, beginning from postbifurcation), size (small, <10 mm; large, ${\geq}10mm$; giant, ${\geq}25mm$), and configuration (c-type 1, classic dissecting aneurysm; c-type 2, segmental ectasia; c-type 3, dolichoectatic dissecting aneurysm). Results : The c-type 3 was more commonly diagnosed with ischemic symptoms (31.8%) than hemorrhage (13.6%), while 40.9% were found accidentally. In contrast, c-type 2 was more commonly diagnosed with hemorrhagic symptoms (14.9%) than ischemic symptoms (10.6%), and 72.3% were accidentally discovered. According to location, ischemic symptoms and hemorrhage were the most frequent symptoms in l-type 1 (28.6%) and l-type 3 (34.6%), respectively. Most of l-type 2 FMCAAs were found incidentally (68.4%). Based on the size of FMCAAs, only 11.1% of small aneurysms were found to be hemorrhagic, while 18.9% and 26.0% of large and giant aneurysms were hemorrhagic, respectively. Although four aneurysms of the 16 FMCAAs in the observation group increased in size and one aneurysm decreased in size during the observation period, no rupture was seen in any case and there were no significant predictors of aneurysm enlargement. Of 104 FMCAAs treated, 14 cases (13.5%) were aggravated than before surgery and all the aggravated cases were l-type 1. Conclusion : While ischemic symptoms occurred more frequently in l-type 1 and c-type 3, hemorrhagic rather than ischemic symptoms occurred more frequently in l-type 3 and c-type 2. In case of l-type 1 FMCAAs, more caution is required in determining the treatment due to the relatively high complication rate.

A Biomechanical Analysis of Four Different Taekwondo Body Punch Types in Horseback-Riding Stance (태권도 주춤 서 몸통지르기 유형별 생체역학적 변인 비교 분석)

  • Kang, Sung-Chul;Kim, Eui-Hwan;Shin, Hyun-Moo;Kim, Sung-Sup;Kim, Tae-Whan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.201-208
    • /
    • 2007
  • The purpose of this study is to compare 4 different body punch types(type 1: a punch using a shoulder, type 2: a punch using a waist, type 3: a punch using lower extremities, and type 4: a punch with elbows by your side at chest level) in horseback-riding stance and establish suitable teaching theory and method, which would be a useful reference to Taekwondo instructors on the spot(in Taekwondo dojangs all around Korea). Five exhibition players from Korean national Taekwondo exhibition team participated in this study. Each participant was asked to perform the four different types of punches and their kinematic and kinetic data were recorded with 7 vicon cameras(125Hz) and two force plates(AMTI, 1200Hz). We analyzed displacement, time, resultant center of body mass trajectory, velocity, trunk angular velocity, and ground reaction force(GRF) from each body segment in body punch and the result. I performed 1-way ANOVA(RM) for average values of each player after standardization and statistical significance was set as p<.05. was as the following ; First, they showed a tendency to take the body punch posture with the biggest motion at a shoulder and on descending order a waist and a knee. Second, a mean time for each body punch on ascending order 0.46sec. for type 2, 0.49sec for type 3, 0.50sec. for type 4, and 0.56sec. for type 1. Third, a mean resultant center of body mass trajectory for each body punch the longest 4.07cm for type 3 and the shortest 2.458cm for type 1. Fourth, a mean of maximal velocity of a fist strike was the fastest 5.99m/s for type 3, 5.93m/s for type 4, 5.67m/s for type 2, and 5.01m/s for type 1 on the descending order. Fifth, a mean of maximal trunk angular velocity of the fastest 495.6deg./sec. for type 4 and 337.7deg./sec. for type 1 on the descending order. Sixth, strongest value was type 3, 2 for anterior-posterior ground reaction force(left -54.89N, right 60.58N), type 4 for medial-lateral GRF(left 83.59N, right -80.12N), and type 3 for vertical GRF(left 341.79N, right 426.11N).

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

The Representative Body Type of Lower Body of Chinese Males in Their 20s (중국(中國) 20대(代) 남성(男性)의 하반신(下半身) 대표체형(代表體型) 연구(硏究))

  • Lee, So-Young;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.11 no.2
    • /
    • pp.58-75
    • /
    • 2007
  • This study held human measurement for 200 male subjects in their twenties in full age living in Ningbo City, Zhejiang Province in China. Their lower body types were classified and grouped according to shapes and sizes. Consequently, representative body type reflecting shapes, sizes, and characteristics were chosen and presented with their measurement values to be used as the basic data for slacks pattern making and fitness evaluation. The following are the results of the analysis: 1. Homogeneity analysis was given to determine the correspondence relationships among index types, indirect types, and size types. Index Type 1 (H-Round), Indirect Type 2 (Adjacent Straight Legs & Slight Slant of Lateral Lower Body), and Size Type 1 (Medium-Thick) were correlated; Index Type 2 (A-Trapezoid), Indirect Type 1 (Bow Legs & Slight Slant of Lateral Lower Body), and Size Type 3 (Small-Slim) were corresponded; Index Type 3 (A-Balance), Indirect Type 3 (Balance Legs & Large Slant of Lateral Lower Body), and Size Type 2 (Tall-Normal) were mutually related. 2. Mahalanobis distance based on each shape factor (index or indirect) and size factor (absolute) was obtained, while an index-absolute representative body type group (47 people, 24.4%) and an indirect-absolute representative body type group (45 people, 23.7%) were chosen, each reflecting shapes, sizes, and characteristics. 3. The representative body type group of lower body shapes of Chinese males in their 20s had average measurement values, such as 169.15cm (stature), 73.32cm (waist circumference), 75.76cm (omphalion waist circumference), 91.08cm (hip circumference), 106.02cm (outside leg length), 53.96cm (thigh circumference), and 74.42cm (crotch length).

A Study on the Optical Bench for LEO Earth Observation Satellite (저궤도 지구관측위성의 광학탑재체 지지구조물 설계 연구)

  • Kim, Kyung-Won;Kim, Jin-Hee;Rhee, Ju-Hun;Jin, Ik-Min;Kim, Jong-Wo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.805-808
    • /
    • 2005
  • This paper is a study on an optical bench satisfying stiffness and thermal pointing error requirements for LEO earth observation satellite. According to shape and stiffness requirements, optical bench type 1 is designed. Because type 1 does not satisfy the thermal pointing error requirement, an optical bench type 2 is suggested. Although the type 2 has better results than type 1, it still does not meet the thermal pointing error requirement. Using the results of optical bench type 1&2, the optical bench type 3 is finally designed, which satisfies both the stiffness and thermal pointing error requirements.

  • PDF

A Study on Higher-Class Houses in Young-Duk Area (영덕군 상류주택에 관한 조사연구)

  • 백영흠;정준현
    • Journal of the Korean housing association
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • This paper is the continuation of the fomer researching "A Study on the Higher-Class houses in Moon-Kyeung Region." and "A Study on the Higher-Class house in Young-Duk area." The study was made to examine the administrative districts in Kyeung Sang Buk Do Province, Korea. This study was aimed to investigate how the houses very according to natural factors including geography and climate. The conclusion is the following: 1) The □-type (A Court House) in the block plan of housing is composed mostly. 2) The □-type (A Winge-House) in the floor plan of housing is more composed than the pure □-type. 3) L-type of the inner space(women's space) is mostly characterized in the floor type and in the type of span-dividision, one and half(1½) spaned house is superior. 4) The majority of the floor plan of the inner space is characterized of the possessing the openning half(½)-spaned room and inner storage room. 5) The cornet-flooring room of outer space(man's space) is charaterized mostly in the floor type.

  • PDF

A Study on New LDD Structure for Improvements of Hot Carrier Reliability (핫 캐리어 신뢰성 개선을 위한 새로운 LDD 구조에 대한 연구)

  • 서용진;김상용;이우선;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • The hot carried degradation in a metal oxide semiconductor device has been one of the most serious concerns for MOS-ULSI. In this paper, three types of LDD(lightly doped drain) structure for suppression of hot carried degradation, such as decreasing of performance due to spacer-induced degradation and increase of series resistance will be investigated. in this study, LDD-nMOSFETs used had three different drain structure, (1) conventional surface type LDD(SL), (2) Buried type LDD(BL), (3) Surface implantation type LDD(SI). As experimental results, the surface implantation the LDD structure showed that improved hot carrier lifetime to comparison with conventional surface and buried type LDD structures.