• Title/Summary/Keyword: TWIST1

Search Result 295, Processing Time 0.026 seconds

Mechanical properties and 3D CAD Images of the Appearance of Cotton/Polyester Composite Yarn Knitted Fabric by Different Yarn Twisting Methods (연사방법에 따른 면/폴리에스테르 복합사 편성물의 역학적 특성 및 3D CAD System에 의한 외관특성)

  • Kim So-Jin;Jeon Dong-Won;Park Young-Hwan
    • Textile Coloration and Finishing
    • /
    • v.18 no.3 s.88
    • /
    • pp.49-58
    • /
    • 2006
  • The purpose of this study was to examine the effect of covering yarn's twist on mechanical properties of knitted fabrics of composite yarns with single covering process. Four yarns that were used in this study: two different composite yarns made from the four kinds of cotton and functional polyester-(Poly-A) with the ratio of 52:48, and the rest two yarns are the original cotton 100% yarn and the poly-A 100% yarn. The two kinds of composite yarns, CP1 and CP2, were processed on the single covering process. CP1 was applied on the single covering process with S-800 tpm, where Poly-A was used as covering yarn and cotton was used as core yarn. CP2 was applied on the same process as CP1 except that Poly-A had been applied on the two-for-one twisting process with S-400 tpm on the previous step. Sixteen mechanical properties of all the four knifed fabrics knitted under the same knitting conditions were measured by KES-FB system with the outer knit condition. And 3D CAD dressmaking simulations, which were driven by some of the mechanical properties, were presented. The results were as follows: CP2 had high RT values with twisting of covering yarn. CP2 also had high B, 2HB values because of higher linear density. SMD was affected rather by twisting of covering yarn than by fine hair of the cotton surface. Twisting of covering yarn made it decreasing T value and increasing W value. Dressmaking 3D CAD simulations showed that there are buckling effects on CP2 because of high bending rigidity and shear rigidity.

Magnetic Sector SIMS의 Sample Holder 위치에 따르는 RSF (Relative Sensitivity Factor) 변화 검증

  • 홍성윤;이종필;홍태은;윤명노;민경열;이순영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.192-192
    • /
    • 1999
  • SIMS(Secondary Ion Mass Spectrometry)는 다른 표면 분석장비와 비교하여^g , pp m,^g , pp b 단위의 미량분석이 가능한 장비로서, 특히 depth Profiling을 위한 dynamic SIMS는 Mass Spectrometer의 종류에 따라 Quadrupole SIMS (Q-SIMS)와, Magnetic Sector SIMS (M-SIMS)로 분류된다. 한편, Q-SIMS와 달리 M-SIMS의 경우, Transmission을 높여 주기 위해 Sample Holder에 수 keV의 bias를 걸어 주는데, 이로 인하여 분석 원소에 대한 Sensitivity가 향상되어 지는 반면, RSF의 변화와 같은 분석상의 Artifact가 발생하게 된다. 일반적으로 Q-SIMS의 경우에는 RSF의 RSD(Relative Standard Deviation)가 1%이내에서 보고되고 있지만 M-SIMS에 있어서는 이러한 Deviation이 M-SIMS보다 크게 나타난다. 이 차이는 주로 Sample Holder와 Immersion Lens 사이에 형성되는 Magnetic Field의 왜곡과 Spectrometer의 문제로부터 발생한다. 본 논문에서는 Sample Holder의 종류 및 holder so window 위치에 따라 RSF의 차이를 측정하고 그 data를 RS/1 통계 Package를 이용하여 계량적으로 검증하였으며, 그 차이의 원인과 대책을 제시하고자 한다. 실험에 사용된 Sample은 Si(100) p-type Wafer에 Boron을 이온 주입하여 제작하였다. 이온 주입 장비는 Varian E-500HP이며, 5.0E13 ions/cm2의 dose양을 80keV의 Energy로 각각 7도와 22도의 Tilt와 Twist Angle로 이온 주입을 하였다. SIMS분석에 사용된 Sample Holder는 각각 3 Hole, 9 Hole Type HOlder이며, 분석은 Cameca IMS-6f를 사용하여 B에 대한 Matrix Peak으로 28Si++를 얻었다. 실험 결과 3 Hole Type Sample Holder의 경우 RSF의 RSD는 5.84%, 9Hle Type Sample Holder의 경우는 14.3%로 나타났으나 분석 Window의 위치에 따르는 Grouping을 실시한 결과, 3 Hole Type Sample Holder의 경우 1.2%, 9Hole Type Sample Holder의 경우 9.8%로 RSF의 변화가 감소하였다. 이러한 Deviation은 Sample Holder를 Mount시킬 때 세 개의 Screw를 이용하여 Immersion Lens와의 평형을 잡아주기 때문에 발생하며, 이 Munting을 정확히 해줌으로써 RSF의 변화를 줄일 수 있으나, 실제로 완벽한 Mounting이 불가능하기 때문에 RSF를 일정하게 하기 위해서는 Sample Holder so Window의 취치를 일정하게 설정한 후 분석을 실시해야 한다고 판단된다.

  • PDF

Thalamotomy without Microelectrode Recording

  • Jeon, Sang-Ho;Kim, Moo-Seong;Lee, Sun-Il;Jung, Yong-Tae;Sim, Jae-Hong;Burchiel, Kim J
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Objective: Tremor, either essential tremor or Parkinsonian tremor, has been effectively and safely treated by lesioning the ventral intermediate(Vim) nucleus of the thalamus with or without mircroelectrode recording. The authors evaluate the treatment outcome of sixteen tremor patients who had been treated with thalamotomy without microelectrode. Methods: Between September, 2001, and December, 2003, sixteen tremor patients were treated with thalamotomy without microelectrode recording. Twelve patients suffered from Parkinsonian tremor and four patients were essential tremor patients. The male to female ratio was 1.6 to 1 with median age of 59.6 years (range; 39-74 years). Under local anesthesia, a 3mm hole was made using a hand-held twist drill, and the dura mater was penetrated with a 1.2mm sharp drill beat. Radiofrequency(RF) electrode was placed in the Vim nucleus of thalamus. With intraoperative macrostimulation, RF lesion was made. Postoperative CT scan and/or MR imaging was performed to confirm the localization of the target lesioned. Preoperative and postoperative tremor was evaluated with simple tremor severity scale and the development of complications related with the procedure was closely reviewed at the immediate postoperative period and the last follow-up. Results: It produces immediate relief in up to 98.4% of the patients. There were no development of complications related with procedure, all patients discharged one or two days after surgery. Conclusion: Vim thalamotomy without microelectrode recording is a safe and effective procedure to control the tremor with minimal morbidity. Intraoperative macroelectrode stimulation safely localizes the Vim nucleus target of the thalamus for the treatment of patients with tremor.

THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF THE JAWS AT THE SIMULATED BILATERAL AND UNILATERAL CLENCHINGS (양측성 및 편측성 이악물기시 상하악골 응력변화 및 변위에 관한 3차원 유한요소법적 연구)

  • Heo, Hoon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.71-92
    • /
    • 1999
  • This study is to analyze the stress and displacement on the jaws during the bilateral and unilateral clenching task on three dimensional finite element model of the dentated skull. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 1.9mm intervals. The CAD data were extracted from the tomograms through digitizer(Summa Sketch III, USA) and then reconstructed by means of the spline method in the CAD program. In this project, a commercial software I-DEAS(Master Series ver-sion 3.0, SDRC Inc, USA) was used for three-dimensional stress analysis on the finite element model. which consists of articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The results are as follows. ; 1. During the bilateral clenching, each major muscle forces caused high stresses on various areas of skull: masseter muscle on articular disc and teeth ; temporal muscle on mandible and periodontal ligament ; medial pterygoid muscle on the temporomandibular joint. During the unilateral clenching, masseter muscle induced the maximum stress ; medial pterygoid muscle the minimum stress. 2. During the bilateral clenching, higher compressive stresses on articular disc were generated by the masseter muscle and higher deformation occurred on the most front outer sites. And during the unilateral clenching, temporal muscle and medial pterygoid muscle exerted their forces to twist temporomandibular joint area of the balancing side and induced a higher compressive stresses on the front outer sites of articular disc. 3. During the bilateral clenching, the masseter muscle bended the mandible outwardly, and then caused tensile stresses on the lingual surface of mandibular symphysis. And the medial pterygoid muscle caused tensile stresses on the labial surface of mandibular symphysis. 4. When each muscles were simultaneously applied on jaws, a high stress and displacement took place on mandible rather than on the maxilla. Also, a high stress and displacement took place during the unilateral clenching rather than during the bilateral clenching.

  • PDF

Kinematics Analysis of Rumba Cucarachas Motion (룸바 쿠카라차 동작의 운동학적 분석)

  • Choi, In-Ae
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.1
    • /
    • pp.145-160
    • /
    • 2004
  • The purposes of this study to provide quantitative data in necessary to advance techniques kinematic analysis of Cucarachas which is an action of Rumba. Then, this study is performed on 5 female players who have won within the third prize at a national athletic meeting. When whole foot reached to floor, Displacement of right-left hip joint (until $E1{\sim}E3$ average moved 15.15cm)is found at right-left direction since the hip joint is turned to right back. On the other side, large displacement is shown because Rumba Cucaracha Movement is expressed by maximum shift of hip joint to right and left direction. Displacement of right hip joint(E3$57.40{\pm}7.46$) is found in front and in rear direction since hip joint is moved in rear and in front to turn the hip joint. It may be stated that this is ideal displacement expressed by movement of whole body with artistic poise and presentation because role of hip joint is very important in technical and artistic side. Angle of right shoulder joint E2($105.44{\pm}9.64$) is got wider. It may be stated that player shifts up and abduct elbow joint to right since center of gravity of player is exceedingly shifted to right in this motion of Cucarachas. On the other hand, since this motion is abducted right elbow and shrunk external abdominal oblique to him center of body to left front of hip joint, the angle becomes narrow. It is shown that angle of knee in right knee joint E4($75.44{\pm}2.61$) is large since right leg and hip joint is turned by foot using reaction of ground and so center of body is shifted to left. Large angle of ankle E4($134.40{\pm}10.50$) in Cucaracha Movement is shown by the action of twist force using narrow part of foot and compression force against ground with adduction speed of arm. The various kinematic analyses associated with motions of dance sport have not been sufficiently peformed so far, and thus a number of research projects for dance sport should be proposed and performed to be continuous.

Inhibition of p90RSK activation sensitizes triple-negative breast cancer cells to cisplatin by inhibiting proliferation, migration and EMT

  • Jin, Yujin;Huynh, Diem Thi Ngoc;Kang, Keon Wook;Myung, Chang-Seon;Heo, Kyung-Sun
    • BMB Reports
    • /
    • v.52 no.12
    • /
    • pp.706-711
    • /
    • 2019
  • Cisplatin (Cis-DDP) is one of the most widely used anti-cancer drugs. It is applicable to many types of cancer, including lung, bladder, and breast cancer. However, its use is now limited because of drug resistance. p90 ribosomal S6 kinase (p90RSK) is one of the downstream effectors in the extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) pathway and high expression of p90RSK is observed in human breast cancer tissues. Therefore, we investigated the role of p90RSK in the Cis-DDP resistance-related signaling pathway and epithelial-mesenchymal transition (EMT) in breast cancer cells. First, we discovered that MDA-MB-231 cells exhibited more Cis-DDP resistance than other breast cancer cells, including MCF-7 and BT549 cells. Cis-DDP increased p90RSK activation, whereas the inactivation of p90RSK using a small interfering RNA (siRNA) or dominant-negative kinase mutant plasmid overexpression significantly reduced Cis-DDP-induced cell proliferation and migration via the inhibition of matrix metallopeptidase (MMP)2 and MMP9 in MDA-MB-231 cells. In addition, p90RSK activation was involved in EMT via the upregulation of mRNA expression, including that of Snail, Twist, ZEB1, N-cadherin, and vimentin. We also investigated NF-κB, the upstream regulator of EMT markers, and discovered that Cis-DDP treatment led to NF-κB translocation in the nucleus as well as its promoter activity. Our results suggest that targeting p90RSK would be a good strategy to increase Cis-DDP sensitivity in triple-negative breast cancers.

Using an appropriate rotation-based criterion to account for torsional irregularity in reinforced concrete buildings

  • Akshara S P;M Abdul Akbar;T M Madhavan Pillai;Rakesh Pasunuti;Renil Sabhadiya
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.349-361
    • /
    • 2024
  • Excessive torsional behaviour is one of the major reasons for failure of buildings, as inferred from past earthquakes. Numerous seismic codes across the world specify a displacement-based or drift-based criterion for classifying buildings as torsionally irregular. In recent years, quite a few researchers have pointed out some of the inherent deficiencies associated with the current codal guidelines on torsional irregularity. This short communication paper aims to envisage the need for a revision of the displacement-based guidelines on torsional irregularity, and further highlight the appropriateness of a rotation-based criterion. A set of 6 reinforced concrete building models with asymmetric shear walls are analysed using ETABS v18.0.2, by varying the number of stories from 1 to 9, and the torsional irregularity coefficient of various stories is calculated using the displacement-based formula. Since rotation about the vertical axis is a direct indication of the twist experienced by a building, the calculated torsional irregularity coefficients of all stories are compared with the corresponding floor rotations. The conflicting results obtained for the torsional irregularity coefficients are projected through five categories, namely mismatch with floor rotations, inconsistency in trend, lack of clarity in incorporation of negative values, sensitivity to low values of displacement and error conceived in the mathematical formulation. The findings indicate that the irregularity coefficient does not accurately represent the torsional behaviour of buildings in a realistic sense. The Indian seismic code-based values of 1.2 and 1.4, which are used to characterize buildings as torsionally irregular are observed to be highly sensitive to the numerical values of displacements, rather than the actual degree of rotation. The study thus emphasizes the revision of current guidelines based on a more relevant rotation-based or eccentricity-based approach.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

Towel Experience and Consumer Satisfaction (소비자 체험조사를 통한 타월 만족도 분석 연구)

  • Song, Kyung-Hun;Heo, Mee-Ok
    • Korean Journal of Human Ecology
    • /
    • v.19 no.6
    • /
    • pp.1063-1070
    • /
    • 2010
  • This study examined 12 types of towels with differing fabric material, function, quality, printing, pile length, twist, etc. from a towel company which manufactures and distributes products domestically. After 3 months of use by consumers, a consumer satisfaction survey was administered and results analyzed. Four types of towels were assigned to each group and the towels were used every day for 3 months. Participant feelings after using the towel for the first time and after using it for three months were investigated. The questionnaire consisted of 26 questions on a 5-point Licket-type scale. The first 13 questions measured perceptions of absorption, touch, fine fiber loss, contamination, deformation, drying speed, and design. Other questions compared differences between the two towel types in terms of their material, function, quality, printing, pile length, and degree of twisting. Results showed that, with regards to weight, consumers preferred towels between 130~150g and a thickness of around 1.7~1.8mm. The bamboo towel was considered superior to the cotton towel in terms of sense of touch and did not happen linter after washing. The antibacterial towel was considered better than the cotton towel in terms of absorption but in terms of contamination, participants felt the antibacterial towel became dirty more easily than the cotton towel. We thought that it might be influence of the color of towel. Low-quality towels became stiffer and misshapen more easily than higher-quality towels. But the study showed that the consumers did not perceive significant differences in the towels' quality. Printed towels became thinner and their color changed more with washing. The consumers preferred the design of jacquard towels to printed towels. Towels with short piles was happened more linter than the towel with long pile after washing. Non-twisted towel were better than the highly-twisted towel in terms of sense of touch and absorption but the non-twisted towel happened more linter after washing and became dirty more easily.

The Characteristics of Textiles excavated in Shilla Tombs($5{\sim}6th$ Century) (신라 $5{\sim}6$세기 임당고분군 직물의 특성)

  • Park, Yoon-Mee
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • Six of the Imdang tombs containing remains with imprints of ancient fabrics and textiles were investigated. Within the tombs, a total of 120 pieces of imprinted fabrics and textiles were investigated, all of which belongs to $5{\sim}6C$ Shilla period. All of the hemp textiles examined exhibited similar characteristics found in ancient hemp textiles: they were woven by plain weave technique with s-twist threads. The examined silk could be categorized into plain woven silk, cho, and double woven brocade, all of them made with non-twisted threads and degummed silk. The density of the plain woven silk ranged from 39 threads to 144 threads. Cho was also found, which showed similar characteristics to those of Gaya and Bakjae tombs. One piece of 2/1 twill weave on plain ground and 12 pieces of double woven brocade were found and their average density was $97.4{\times}33.4/cm$ with denser warp than weft. The various thickness of the threads were observed in the examined plain braid. The silk with twining technique showed thicker warp than weft. This is similar to the techniques of fabrics found in the King Muryeoung's Tomb of the Bakjae period. Fabrics with the purple-like color were observed in the some of the double woven brocades and also on the plain woven silk imprinted on the remains. The purple-like color was revealed to be purple with a tint of violet. The two tombs from which the imprinted fabrics with purple-like color were found belonged to top-class social level of the Shilla period, which informs that the purple color was used exclusively for the people of higher social status. The floss silk was found between the double woven brocade and plain woven silk of the belt, which is an important evidence that the floss silk was used for stuffing in the early 6th century.