• Title/Summary/Keyword: TWA model

Search Result 13, Processing Time 0.023 seconds

A New TWA-Based Efficient Signal Integrity Verification Technique for Complicated Multi-Layer RLC Interconnect Lines (복잡한 다층 RLC 배선구조에서의 TWA를 기반으로 한 효율적인 시그널 인테그러티 검증)

  • Jo Chan-Min;Eo Yung-Seon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.20-28
    • /
    • 2006
  • A new TWA(Traveling-wave-based Waveform Approximation)-based signal integrity verification method for practical interconnect layout structures which are composed of non-uniform RLC lines with various discontinuities is presented. Transforming the non-uniform lines into virtual uniform lines, signal integrity of the practical layout structures can be very efficiently estimated by using the TWA-technique. It is shown that the proposed technique can estimate the signal integrity much more efficiently than generic SPICE circuit model with 5% timing error and 10% crosstalk error.

Instructional Effects of Multiple Analogies on Conceptual Understanding and Learning Motivation (다중 비유를 사용한 수업이 개념 이해 및 학습 동기에 미치는 효과)

  • Kwon, Hyeok Soon;Noh, Tae Hee
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.177-182
    • /
    • 2001
  • An instructional model using multiple analogies according to component process (MACP) was designed on the vasis of schema theory and comornent process theory in analogical reasoning. This model has ? phases: introducting multiple analsgs, extracting multiple analogs, extracting common attributes of analogs, introducing target conanother context. Te instructional effects of this model upon students' conceptual understanding and learning motivation were compared with those of the Teaching-With-Analogy (TWA) and non-analogy instructions. Three classes of 8th grade were randomly assigned to MACP, TWA, and control group, respectively, Subjects were taught about chemical changes and reactions for 10 class hours. The ANCOVA results indicated that the scores of the conceptions test for the MACP group were significantly higher than for the control graup. However, no significant differences were found among the three groups in the test scores of learning motivation.

  • PDF

The Effects of Analyzing Mapping Errors in Concept Learning on the Three States of Matter with Analogy (비유를 사용한 물질의 세 가지 생태 개념 학습에서 대응 오류 분석 활동의 효과)

  • Kim, Kyung-Sun;Byun, Ji-Sun;Shin, Eun-Ju;Noh, Tae-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.9
    • /
    • pp.778-786
    • /
    • 2007
  • This study investigated the effects of analyzing mapping errors on conceptual understanding, mapping understanding and perceptions of the instructions in learning chemistry concept with analogy. Seventh graders (N=121) at two middle schools were assigned to the comparison and the treatment groups, and were taught about 'states of matter and arrangement of molecules.' The students in the comparison group were taught in the Teaching-With-Analogy (TWA) model, while those in the treatment group Were taught in the instructional model that changed 'mapping similarity' and 'indicating difference' of the TWA model into 'analyzing mapping errors.' Analysis of the results revealed that the scores of the conception test and the mapping test for the treatment group were significantly higher than those far the comparison group regardless of field dependence-independence. It was also found that most students in the two groups positively perceived the instructions with analogy, but the students in the treatment group had difficulties in analyzing mapping errors, Educational implications are discussed.

송전선로 주변 거주 초등학생들의 전자장노출량 평가 모델 개발

  • Kim, Yun-Sin;Hyeon, Yeon-Ju;Choe, Seong-Ho;Jo, Yong-Seong;Hong, Seung-Cheol
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.118-120
    • /
    • 2005
  • 본 연구는 송전선 주변 거주 초등학교 학생들을 대상으로 시간 활동 행태에 따른 여러 미세환경, 즉 주거환경, 학교환경, 학원, PC방, 교통에서의 자기장 노출수준을 다양한 매트릭스를 이용하여 비교 ${\cdot}$ 분석함으로써 연구대상자들의 활동한 미세환경 인자를 평가하여 시간별행동양식에 따른 24 시간 개인노출수준을 시간가중 평균모델을 이용하여 예측하고 비교 ${\cdot}$ 평가하였다. 본 연구는 154kV 고압 송전선로가 초등학교 옥상을 통과하는 B 초등학교 125명을 최종 선정하여 2003년 7월부터 2004년 2월 말까지 실시하였으며, 시간가중평균모델을 바탕으로 하여 자기장 노출량 평가 모델을 개발하였다. 전체 연구대상자들의 미세환경 내 평균 자기장값으로 계산한 시간가중 평균모델 (TWA model II)을 이용하여 예측된 자기장 개인노출수준을 보면 실측된 개인노출수준과 약간의 상관성을 보였다(Pearson r = 0.34 ${\sim}$ 0.35). Spot 측정한 값과 24 시간 stationary 측정값을 이용한 TWA Model II-2로 예측한 결과 실측값간의 상관성이 0.65 ${\sim}$ 0.85 로 산출되어 TWA 모델 중 가장 실측값을 잘 설명하였다.

  • PDF

Study about Prediction Model to Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Nearby High Voltage Power Line (고압 송전선로 주변에 위치한 초등학교 학생들의 극저주파 자기장 노출량 예측 모델에 관한 연구)

  • Kim, Yoon-Shin;Hyun, Youn-Joo;Choi, Seong-Ho;Roh, Young-Man;Hong, Seung-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.506-514
    • /
    • 2006
  • The objectives of this study were to evaluate personal exposure estimated using a time activity pattern and microenvironmental model. The study was carried out for 44 children attending a primary school nearby the lines (school A) and 125 children attending a school away from 154 kV power lines (school B). For children attending school A, the estimated personal level was a little weak correlated with the measured level($Pearson\;r\;=0.34{\sim}0.35$). For children attending school B, the correlation was very low ($Pearson\;r\;=\;0.09{\sim}0.16$) using the TW A Model II, otherwise, TWA Model II-I which considered the average residential MF level according to the distance from the power line and home explained $39{\sim}53%$ of the correlation in MF personal exposures. The estimated personal exposure level was very well represented by the measured exposure level using TWA Model II-2 which consisted on spot and 24 h stationary measurements at subject's home ($Pearson\;r\;=\;0.65{\sim}0.85$). In conclusion, personal magnetic field expsoure estimated using a TWA Model II-2 should be provided for a reasonable estimate of measured exposure in schoolchildren living near the power line.

Estimation of Total Exposure to Benzene, Toluene and Xylene by Microenvironmental Measurements for Iron Mill Workers (제철소 근로자의 벤젠/톨루엔/크실렌 국소환경 측정을 이용한 총 노출 예측)

  • Kim, Young-Hee;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.359-364
    • /
    • 2007
  • The aim of this study were to assess the personal exposure to volatile organic compounds (VOCs) and to estimate the personal exposure using time-weighted average model. Three target VOCs (benzene, toluene, xylene) were analyzed in personal exposure samples and residential indoor, residential outdoor and workplace indoor microenvironments samples in the iron mill 30 workers during working 5 days. Personal exposure to VOCs significantly correlated with workplace concentration p<0.05), suggesting workplace had strong source and major contribution to personal exposure. Personal exposure could be estimated with time activity pattern and time weighted average (TWA) model of residential indoor and workplace concentrations measured. Time weighted mean microenvironments concentrations were close approximately of personal exposure concentrations. Total exposure for participants can be estimated by TWA with microenvironments measurements and time activity pattern.

Overview of the Korean Marine Industry and VPP Analysis of a 28ft Sailing Yacht (대한민국의 해양 레저 시장 및 28ft급 세일요트의 VPP 성능해석 연구)

  • Yeongmin Park;Hoyun Jang;Minsu Kang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.4
    • /
    • pp.365-372
    • /
    • 2024
  • The South Korean marine industry is emerging as a significant market, driven by the growing popularity of various water leisure activities, including sailing. This trend suggests a rising demand for sailing yachts. Consequently, since 2022, the design and development of a 28ft sailing yacht have been ongoing, supported by the government and the Ministry of Oceans and Fisheries, to promote yachting culture in South Korea. The Velocity Prediction Program (VPP) analysis was conducted using WinDesign during the preliminary design stage to evaluate performance and determine design parameters. The hydrodynamic model used for this vessel is based on regression methods developed from years of experience in naval architecture and yacht research at the Wolfson Unit, providing reliable estimates for most modern yachts. However, owing to the lack of specific hydrodynamic data from towing tank tests or CFD numerical analysis, verification of the hydrodynamic model has faced some challenges. Additionally, an incomplete weight estimate resulted in variable VCG values, potentially affecting stability and overall performance. The optimal boat speed for this vessel was determined at true wind speeds (TWS) of 4, 8, 12, 16, and 20 knots, using both the jib (up to 120° TWA) and the spinnaker (from 80° TWA). The optimized speed of the yacht was found to be comparable to that of international similar-class yachts.

A Study on Worker Exposure to Trichlorethylene and Emission Factor for Degreasers in Plating Plants (중소기업 도금공정에서의 트리클로로에틸렌 폭로와 발산량에 관한 연구)

  • Lee, Keoung Hee;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.3-13
    • /
    • 1993
  • This study was conducted at seven degreasing processes in plating plants located in Seoul, Incheon, Ansan, and Taejeon areas from July 21 to august 27, 1992. This study was performed to assess the TWA exposures to trichloroethylene (TCE) and evaluate factors affecting TCE concentrations in degreasing process. Two-Point Eddy Diffusional Model suggested by Wadden et al. was employed to calculalte emission factors according to degreaser type. Results are summarized as follows. 1. The TWA exposures of the degreasing operators ranged from 1.4 ppm to 123 ppm, and those of three plants out of seven were exceeding 50 ppm of both the Korean and U.S. OSHA standards. Degreasing assistant of Plant B, was exposed to 59 ppm. 2. The average concentrations at the distance 0, 1.5, 3.0 m from the degreasers were 1.014, 24, and 18 ppm, respectively, and showed a signifficant difference by distance (p<0.01). 3. The emission of TCE was reduced by installing local exhaust systems, condensers, and refrigeration lines at the degreasers (p<0.01). 4. The major factors related to exposure of operators were workload (r=.9621. p<0.01) and dimensions of degreansing room(r=-.8667, p<0.05). 5. If the air in degreasing room is mixed violently by other factors in addition to diffusion, the emission factors can not be evaluated because the important hypothesis of the Two-Point Eddy Diffusional Model can not be accepted. 6. The ultrasonic degreaser without the local exhaust ststem, condenser, and refrigeration lines emitted TCE three times greater than the ultrasonic degreaser with condenser and refrigeration 1ines only.

  • PDF

Scenario Analysis of Personal Nitrogen Dioxide Exposure with Monte Carlo Simulation on Subway Station Workers in Seoul (확률론적 모의실험 기법을 이용한 일부 지하철 근무자들의 이산화질소 개인노출 시나리오 분석)

  • 손부순;장봉기;양원호
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 2001
  • The personal exposures of nitrogen dioxide(NO$_2$), microenvironmental levels and daily time activity patterns on Seoul subway station workers were measured from February 10 to March 12, 1999. Personal NO$_2$exposure for 24 hours were 29.40$\pm$9.75 ppb. NO$_2$level of occupational environment were 27.87$\pm$7.15 ppb in office, 33.60$\pm$8.64 ppb in platform and 50.13$\pm$13.04 ppb in outdoor. Personal exposure time of subway station workers was constituted as survey results with $7.94\pm$3.00 hours in office, $2.82\pm$1.63 hours in platform and 1 hours in outdoor. With above results, personal $NO_2$exposure distributions on subway station workers in Seoul were estimated with Monte Carlo simulation which uses statistical probabilistic theory on various exposure scenario testing. Some of distributions which did not have any formal patterns were assumed as custom distribution type. Estimated personal occupational $NO_2$exposure using time weighted average (TWA) model was 31.$29\pm$5.57 ppb, which were under Annual Ambient Standard (50ppb) of Korea. Though arithmetic means of measured personal $NO_2$exposure was lower than that of occupational $NO_2$exposure estimated by TWA model, considering probability distribution type simulated, probability distribution of measured personal $NO_2$exposures for 24 hours was over ambient standard with 3.23%, which was higher than those of occupational exposure(0.02%). Further research is needed for reducing these 24 hour $NO_2$personal excess exposures besides occupational exposure on subway station workers in Seoul.

  • PDF

The Effect of an Instruction Using Generating Analogy on Students’ Conceptual Understanding in Middle School Science Concept Learning (중학교 과학 개념 학습에서 비유 만들기를 이용한 수업이 학생들의 개념 이해에 미치는 효과)

  • No, Tae-Hui;Kim, Gyeong-Sun;Choe, Eun-Gyu;Cha, Jeong-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.338-345
    • /
    • 2006
  • study investigated the effect of an instruction using generating analogy on scientific conceptual understanding, science learning motivation, attitude toward science instruction, and perception of instruction. Two classes of seventh graders at a middle school in Seoul were randomly assigned to the treatment group and the control group, and they were taught about the motion of molecules for 5 class hours. The instruction for treatment group was developed based on the Glynns Teaching-With-Analogy model. Two-way ANCOVA results revealed that the scores of the treatment group were significantly higher than those of the control group in the conception test. However, there was no significant difference between two groups in the science learning motivation test and the test on the attitude toward science instruction. Survey results on the students perception of instruction showed that generating analogy was hard for the greater part of students, and finding appropriate analog was the most difficult work. Educational implications are discussed.