• Title/Summary/Keyword: TRIGA Mark II

Search Result 46, Processing Time 0.024 seconds

An Analysis of Shielding Design of TRIGA Mark-II Reactor

  • Lee, Chang-Kun
    • Nuclear Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.185-197
    • /
    • 1971
  • Korea's TRIGA Mark-Ⅱ reactor was primarily designed in 1950's and was constructed in 1962 for 100 kw thermal output, but it was upgraded to 250 kw in July 1969. Nevertheless, the shield remains unchanged, although the radiation level has increased. The result of computation On this paper shows that, with the existing shield, it is safe for the fast neutrons even after the power upgrading by 2.5 times. It is, however, somewhat dangerous for the gamma rays which are comprised of primary and secondary. For the analysis of the reactor shielding design, an attempt is made for the computation toward the horizontal direction. From theoretical point of view, it can be concluded that some layer of additional shield must be reinforced to the existing concrete in order to be radiologically safe in the reactor hall.

  • PDF

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.291-309
    • /
    • 1973
  • Exposure rates due to leakage gamma-rays from operating reactors TRIGA Mark II and III were measured in a horizontal plane by means of scintillation spectrometry using a 3"$\times$3" cylindrical Nal(T1) detector associated with a 400 channel pulse height analyzer under varied conditions of reactor operation. In determining exposure rate due to the leakage gamma-rays at each point of measurement, Moriuchi's spectrum-exposure rate conversion theory was applied instead of using conventional responce matrix method which necessitates very complicated procedures to convert a spectrum into exposure rate. The results show that a basic pattern of "typical" spectrum of the reactor leakage gamma-rays is neither affected by thermal output of the reactor, nor influenced by overall attenuation in radiation intensity. It was indicated that he attenuation of the leakage gamma-rays in air in terms of exposure rate as a whole follows an exponential law, and the total exposure rate due to the leakage gamma-rays at a certain point is nearly proportional to thermal output of the reactor. The complexity in spectrum measured for a movable core reactor, TRIGA Mark III, was analyzed through spectrum resolution, and proper judgement of the leakage gamma-rays in a complex spectrum was discussed.ctrum was discussed.

  • PDF

Validation of a New Design of Tellurium Dioxide-Irradiated Target

  • Fllaoui, Aziz;Ghamad, Younes;Zoubir, Brahim;Ayaz, Zinel Abidine;Morabiti, Aissam El;Amayoud, Hafid;Chakir, El Mahjoub
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1273-1279
    • /
    • 2016
  • Production of iodine-131 by neutron activation of tellurium in tellurium dioxide ($TeO_2$) material requires a target that meets the safety requirements. In a radiopharmaceutical production unit, a new lid for a can was designed, which permits tight sealing of the target by using tungsten inert gaswelding. The leakage rate of all prepared targets was assessed using a helium mass spectrometer. The accepted leakage rate is ${\leq}10^{-4}mbr.L/s$, according to the approved safety report related to iodine-131 production in the TRIGA Mark II research reactor (TRIGA: Training, Research, Isotopes, General Atomics). To confirm the resistance of the new design to the irradiation conditions in the TRIGA Mark II research reactor's central thimble, a study of heat effect on the sealed targets for 7 hours in an oven was conducted and the leakage rates were evaluated. The results show that the tightness of the targets is ensured up to $600^{\circ}C$ with the appearance of deformations on lids beyond $450^{\circ}C$. The study of heat transfer through the target was conducted by adopting a one-dimensional approximation, under consideration of the three transfer modes-convection, conduction, and radiation. The quantities of heat generated by gamma and neutron heating were calculated by a validated computational model for the neutronic simulation of the TRIGA Mark II research reactor using the Monte Carlo N-Particle transport code. Using the heat transfer equations according to the three modes of heat transfer, the thermal study of I-131 production by irradiation of the target in the central thimble showed that the temperatures of materials do not exceed the corresponding melting points. To validate this new design, several targets have been irradiated in the central thimble according to a preplanned irradiation program, going from4 hours of irradiation at a power level of 0.5MWup to 35 hours (7 h/d for 5 days a week) at 1.5MW. The results showthat the irradiated targets are tight because no iodine-131 was released in the atmosphere of the reactor building and in the reactor cooling water of the primary circuit.

Fabrication and Characteristics of Thin-film Neutron Thermopile for Reactor Instrumentation (원자로계측을 위한 박막중성자열전대의 시작 및 특성)

  • 김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.5
    • /
    • pp.1-5
    • /
    • 1972
  • In order to improve the response time of nelltron theromopile for reactor control a neutron thermopile made use of a vacuunl evaporated thin film thor mocouple was fablicated and tested. The test results were compared with a wire-type neutron thermopile. Good linearities between the response of the neutron thermopile and the thermal flux has been shown in the ranges from n/$\textrm{cm}^2$/sec. Thermal neutron flux distributions in the core of TRIGA Mark-II reactor were measured using the fabricated neutron thermopile, and the results were conpared with data obtained by the acrivatin foil measurement.

  • PDF

Optimation of Reactor Control System by using Random Noise (랜덤 잡음을 이용한 원자로의 제어계 최적안전운전에 관한 연구 (1))

  • 고병준;신재인
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 1969
  • Reactor power frequency spectrum measurements at various power levela-OW, 1KW, 50KW, 100KW were made with TRIGA-MARK-II. An ion chamber was exposed to reactor flux, and the fluctions in its output current were analyed in a tunable bandpass filter to get the frequency spectrum of these fluctuation. The measured frequency spectrum of pile determined the modules of modules of zero power transfer function and indicated a prompt neutron mean life time of (7.90$\pm$1.62)X10 sec based on effective delayed neutron faction of 0.0075. The absolute value of reactor power obtained by noise analysis agreed within 5% with the power meter indication at the power below 10Kw.

  • PDF

Neutronics analysis of TRIGA Mark II research reactor

  • Rehman, Haseebur;Ahmad, Siraj-ul-Islam
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • This article presents clean core criticality calculations and control rod worth calculations for TRIGA (Training, Research, Isotope production-General Atomics) Mark II research reactor benchmark cores using Winfrith Improved Multi-group Scheme-D/4 (WIMS-D/4) and Program for Reactor In-core Analysis using Diffusion Equation (PRIDE) codes. Cores 133 and 134 were analyzed in 2-D (r, ${\theta}$) and 3-D (r, ${\theta}$, z), using WIMS-D/4 and PRIDE codes. Moreover, the influence of cross-section data was also studied using various libraries based on Evaluated Nuclear Data File (ENDF/B-VI.8 and VII.0), Joint Evaluated Fission and Fusion File (JEFF-3.1), Japanese Evaluated Nuclear Data Library (JENDL-3.2), and Joint Evaluated File (JEF-2.2) nuclear data. The simulation results showed that the multiplication factor calculated for all these data libraries is within 1% of the experimental results. The reactivity worth of the control rods of core 134 was also calculated with different homogenization approaches. A comparison was made with experimental and reported Monte Carlo results, and it was found that, using proper homogenization of absorber regions and surrounding fuel regions, the results obtained with PRIDE code are significantly improved.

Study on Rector Dynamic Response by Cross Correlation Method (상호상관함수법에 의한 원자로 동특성에 관한 연구)

  • 고병준
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.4
    • /
    • pp.60-73
    • /
    • 1973
  • The reactor noise analysis was performed by the cross correlation method using two detectors to determine the dynamic stability and the system parameter of TRIGA Mark-II reactor under critical and subcritical conditions. The a values turned out to be 46.67 and 70.04 respectively at zero power and full power under critical condition, while 79.47 and 97.59 respectively at the safety rod dropping and the regulating rod dropping under subcritical condition. Prompt neutron life time of TRIGA Mark-II reactor measured 107 and 160 $\mu$sec, and shut down margin was -10.03$\times$10-4 at the safety rod dropping and -29-43$\times$10-4 at the regulating rod dropping CDC 3100/MSOS digital computer, HITACHI 505 Analog computer, and preamplifier, bandpass filter, FM modulator or demodulator designed for this specific purpose, were employed for the present investigation.

  • PDF