• Title/Summary/Keyword: TRANSDUCER

Search Result 2,040, Processing Time 0.03 seconds

Evaluation of Thickness Reduction in Steel Plate by Using SH-EMATs (수평횡파 송수신용 EMAT를 이용한 스틸 박판의 두께 감육 평가)

  • Lee, Jin-Hyuk;Park, Ik-Keun;Kim, Yong-Kwon;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • An electromagnetic acoustic transducer(EMAT) is a non-contact transducer which can transmit the ultrasonic guided waves into specimens without couplant. And it can easily generate specific guided waves such as SH(shear horizontal) or Lamb waves by altering the design of coil and magnet. In this study, the SH wave, which is generated by EMAT, has been applied to estimate the thickness-reduction in a steel plate. Especially, the interesting feature of the dispersive behavior in selected wave modes is used to detect the thickness-reduction. Experimental results show that the reduction-level can be quantified by the measurement of the group velocity of the wave which passes though the thinning area.

Investigation on lamb wave propagation in silicon wafer using large aperture line-focused transducer (대구경 선집속 탐촉자를 이용한 실리콘 웨이퍼에서의 램파 전파 특성 분석)

  • Chung, Yoonjae;Yang, Seung Soo;Yu, Minjae;Kim, Young H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.174-180
    • /
    • 2018
  • In this study, the propagation characteristics of Lamb waves in anisotropic silicon wafers of (100) and (111) direction were investigated by PVDF (Polyvinylidene Fluoride) line-focused transducer. The modified V(f,z) method was used because the Lamb waves are dispersive. For confirming the anisotropy, a line-focused transducer was used and the silicon wafer was rotated 180 degrees at intervals of 1 degree. As a result, $A_0$ and $S_0$ modes were observed. The speed of $S_0$ mode according to propagation direction showed anisotropy which is associated with the crystal structure, and the speed of $A_0$ mode was isotropic. The result is consistent with the crystal structure of silicon and the mechanism of vibration of each Lamb wave modes.

Transducer analysis and signal processing of PMSF with embedded bluff body

  • Yan, Xiao-Xue;Xu, Ke-Jun;Xu, Wei;Yu, Xin-Long;Wu, Jian-Ping
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.296-307
    • /
    • 2020
  • Permanent magnet sodium flowmeter (PMSF) have been used to measure the sodium flow in fast breeder reactors. Due to the effects of irradiation, thermal cycling, time lapse, etc., the magnetic flux density of the PMSF will decrease after being used in the reactor for a period of time. Therefore, it must be calibrated regularly. But some flowmeters that immersed in sodium cannot be removed for an off-line calibration, so the on-line calibration is required. However, the best online calibration accuracy of PMSF using cross-correlation analysis method was 2.0-level without considering the repeatability. In order to further improve this work, the operational principle of the transducer in PMSF is analyzed and the design principle of the transducer is proposed. The transducers were tested on the sodium flow loop to collect the experimental data. The signal characteristics are analyzed from the time and frequency domains, respectively. The cross-correlation analysis method based on biased estimation is adopted to obtain the flow rate. The verification experimental results showed that the measurement accuracy is 1.0-level when the flow velocity is above 0.5 m/s, and the measurement accuracy is 3.0-level when the flow velocity is in the range of 0.2 m/s to 0.5 m/s.

Vibration characteristic analysis of differential floating mass transducer using electrical model for fully-implantable middle ear hearing devices (전기 모델에 의한 완전 이식형 인공중이용 차동 전자 트랜스듀서의 진동 특성 해석)

  • Kim, Min-Woo;Kim, Min-Kyu;Seong, Ki-Woong;Lim, Hyung-Gyu;Jung, Eui-Sung;Han, Ji-Hun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.165-173
    • /
    • 2007
  • A differential floating mass transducer has been developed in Korea for fully implantable middle ear hearing devices (F-IMEHDs). In particular, the performance of a differential floating mass transducer (DFMT) is very important among the parts of the F-IMEHDs because the mechanical vibration generated by DFMT is delivered to the inner ear directly. In this paper, the electrical model is proposed to analyze the DFMT vibration characteristic using the mechanical model of the DFMT. The electrical model enables the simple analysis of DFMT vibration characteristics using a computer program. The proposed electrical model is simulated through PSpice as changing the values of passive elements in the electrical model. To verify the proposed model, the DFMT has been implemented on the basis of the simulated results and the experiment for vibration measurement has been carried out. Through the comparison, it is verified that the proposed model is useful to analyze the vibration characteristics of the DFMT.

W-Band Turnstile Junction Ortho-Mode Transducer for Millimeter Wave Seeker (턴스타일 구조를 갖는 밀리미터파 탐색기용 W-대역 직교모드 편파기 설계)

  • Han, Jun-Yong;Lee, Taek-Kyung;Lee, Jae-Wook;Oh, Gyung-Hyun;Song, Sung-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.9
    • /
    • pp.872-875
    • /
    • 2016
  • In this paper, the turnstile junction-based Ortho-Mode Transducer(OMT) is designed and manufactured. It is usually well-known that turnstile junctions have symmetry structure of waveguide so the higher order modes, which occurs inside the waveguide, can be cancelled. Because of these symmetrical properties, the turnstile junction-based OMTs have merits like high transmission and low return loss characteristic in broadband and two different modes propagate orthogonally in common port resulting in the fully realization of double polarization. The designed OMT has the application of Radar Seeker and operates in W-band(94 GHz), the millimeter wave frequency. The average of return loss value of manufactured OMT is lower than -20 dB and it has bandwidth characteristic of over 500 MHz.

Flaw Detection in Pipe-Welded Zone by Using Wavelet Transform and SH-EMAT (웨이브렛 변환과 SH-EMAT을 이용한 배관 용접부 결함 검출)

  • Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1511-1519
    • /
    • 2012
  • Pipe structures contain many welded zones, and ultrasonic tests are increasingly being performed by using automated testing devices in order to evaluate the weld integrity. An electromagnetic acoustic transducer (EMAT) is a noncontact transducer that can transmit or receive ultrasonic waves without a couplant. Furthermore, it can easily generate specific guided waves such as SH (shear horizontal) or Lamb waves by altering the design of the coil and magnet. Therefore, an EMAT should be useful for application to an automated ultrasonic inspection system. In this study, SH waves generated using an EMAT were applied to inspect the pipe-weld zone. To analyze the specific SH mode (SH0) from the SH wave signals, wavelet transform was applied. It was found that flaws could be detected precisely because the intensity of the $SH_0$ mode-frequency, which is analyzed by using wavelet transform, is proportional to the length of the flaw.

3-D Underwater Object Recognition Using PZT-Epoxy 3-3 Type Composite Ultrasonic Transducers (PZT-에폭시 3-3형 복합압전체 초음파 트랜스듀서를 사용한 3차원 수중 물체인식)

  • Cho, Hyun-Chul;Heo, Jin;SaGong, Geon
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.286-294
    • /
    • 2001
  • In this study, 3-D underwater object recognition using the self-made 3-3 type composite ultrasonic transducer and modified SOFM(Self Organizing Feature Map) neural network are investigated. Properties of the self-made 3-3 type composite specimens are satisfied considerably with requirements as an underwater ultrasonic transducer's materials. 3-D underwater all object's recognition rates obtained from both the training data and testing data in different objects, such as a rectangular block, regular triangular block, square block and cylinderical block, were 100% and 94.0%, respectively. All object's recognition rates are obtained by utilizing the self-made 3-3 type composite transducer and SOFM neural network. From the object recognition rates, it could be seen that an ultrasonic transducer fabricated with the self-made 3-3 type composite resonator will be able to have application for the underwater object recognition.

  • PDF

Unequal Distance Sampling Technique to Design Velocity-Type Respiratory Air Flow Transducer (속도 계측형 호흡기류센서 설계를 위한 비균등 샘플링 기법)

  • 김경아;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.351-359
    • /
    • 2004
  • Velocity-type repisratory air flow transducer measures dynamic pressure converted from air velocity based on the we1l-known Bernoulli's principle. It requires multiple velocity sampling holes on the flow plane. Measurement error theoretica1ly estimated by computer simulation was demonstrated to significantly reduce by unequally locating the velocity sampling holes. The flow plane was divided into multiple equi-area rings and the sampling holes were located on the circles also equally dividing each ring's area, which decreased measurement error down to 1/5 of the simple equi-radius ring division method. Also, less than 1 % relative error was estimated with 4 or more sampling holes. The present technique was less sensitive by <1/2 to the velocity profile change compared to the euqi-radius sampling. Therefore, the present unequal distance velocity sampling technique should be of great use to design the structure of the velocity-type respiratory air flow transducer.

Forward-Looking Ultrasound Imaging Transducer : I. Analysis and Design (전향 초음파 영상 트랜스듀서 : I. 해석 및 설계)

  • Lee, Chan-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.73-86
    • /
    • 1995
  • The transducer section of the forward-looking ultrasound imaging catheter (FLUIC) consists of a circular piezoelectric element as a vibrator and a conical acoustic mirror as a perfect reflector. A small diameter piezoelectric transducer element is mounted on the side of a catheter's rotating shaft. The unique design of FLUIC provides the capability to form a two-dimensional image of a cross-section of vessel in front of the catheter, which is lacking in the present generation of intravascular ultrasound (IVUS) transducers, as well as a conventional side view image. The mirror configuration for the transducer section of the FLUIC is designed using an approximated ray tracing techniques. The diffraction transfer function approach [1] developed for the field prediction from primary sources is generalized and extended to predict the secondary diffraction characterstics from an acoustic mirror. The extended model is verified by simulation and experiment through a simple plane reflector and employed to analyzed the field characteristics of a FLUIC.

  • PDF

Ultrasonic Transducer Application for Nondestructive Testing of Continuous Cast Billets (연주빌렛의 비파괴 검사를 위한 초음파 센서의 응용)

  • Shin, Byoung-Chul;Kwon, Jeong-Rock
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.25-31
    • /
    • 1996
  • Steel wires are made by elongating hot billets. If the billets have internal or surface defects, the wire can be broken during elongation process. After testing surface defect, we are testing internal defect by ultrasonic transducers. POSCO is producing two kinds of billets, hot rolled billet and cast billet. Hot rolled one is denser than cast billet. Because of the low density and rough surface, ultrasonic testing is difficult for the cast billet. Size of the transducer was related with the size and density of the billet. A transducer having 21mm long, 8.5mm wide and 0.95mm thick piezoelectric ceramic plate was best for $160mm\;{\times}\;160mm$ cast billet. Center frequency of the transducer was 2.25MHz and the focus distance was 70mm.

  • PDF