Fabrication and FEM Analysis of Wind-Mill Type Ultrasonic Motors using Piezoelectric Ceramics (압전 세라믹스를 이용한 풍차형 초음파모터의 제작과 유한요소해석)

  • 강형우;이상기;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.373-376
    • /
    • 2000
  • The modified Moonie(Cymbal) transducer has been investigated for an accelerometer application. This paper present a wind-mill type ultrasonic motors using ternary piezoelectric ceramics and aluminum endcaps applied by cymbal transducer. The maximum displacement was increased depend on applied voltage and layer number. The multi-layer was fabricated by tape casting using doctor-blade process. The maximum displacement of multi-layered ultrasonic motor was much higher than that of one-layered.

  • PDF

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

Parametric Array Signal Generating System using Transducer Array (트랜스듀서 배열을 이용한 파라메트릭 배열 신호 생성 시스템)

  • Lee, Jaeil;Lee, Chong Hyun;Bae, Jinho;Paeng, Dong-Guk;Choe, Mi Heung;Kim, Won-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.287-293
    • /
    • 2013
  • We present a parametric array signal generating system using $3{\times}16$ transducer array which is composed of multi-resonant frequency transducers of 20kHz and 32.5kHz. To drive transducer array, sixteen channel amplifier using LM1875 chips is designed and implemented, and the PXI system based on the LabView 8.6 for arbitrary signal generation and analysis is used. Using the proposed system, we measure sound pressure level and beam pattern of difference frequency and verify the nonlinear effect of difference frequency. The theoretical absorption range and the Rayleigh distance are 15.51m and 1.933m, respectively and we verify that sound pressure of difference frequency is accumulated and increased at the near-field shorter than the Rayleigh distance. We verify that the beam pattern of the measured difference frequency and the beam pattern obtained by the superposition of two primary frequencies are similar, and high directional parametric signal was generated.

Design of a wideband cymbal transducer array (광대역 심벌 트랜스듀서 배열 설계)

  • Kim, Donghyun;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.170-178
    • /
    • 2020
  • Cymbal transducers are often used as an array rather than single because they have a high quality factor and low energy conversion efficiency. When used as an array, there occurs a big change in the frequency characteristics of the array due to the interaction between constituent transducers. In this study, we designed the structure of a cymbal transducer array to have ultra-wideband characteristics using this property. First, cymbal transducers with specific center frequencies were designed. Then, a 2×2 planar array was constructed with the designed transducers, where the cymbal transducers were arranged to have same or opposite polarization directions. For this structure, we analyzed the effect of the difference in the center frequency of and the spacing between the constituent transducers on the acoustical characteristics of the array. Based on the analysis, we designed the structure of the cymbal transducer array to have the widest possible bandwidth.

Design of Signal Processing Circuit for Semi-implantable Middle Ear Hearing Device with Bellows Transducer (벨로즈형 진동체를 갖는 반이식형 인공중이용 신호처리회로 설계)

  • Kim, Jong Hoon;Shin, Dong Ho;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.63-71
    • /
    • 2017
  • In this paper, a signal processing circuit for semi-implantable middle ear hearing device is designed using the TCBT which is recently proposed for a new middle ear transducer that can be implanted at round window of cochlea. The designed semi-implantable hearing device transmits digital sound signal from external device located at behind the ear to the internal device implanted under the skin using inductive coupling link methods with high efficiency. The coils and signal processing circuits are designed and implemented considering the total transmission and reception distance including skin thickness of temporal bone for the semi-implantable hearing device. And also, to improve the data transmission efficiency, the output circuits which can supply sufficient signal power is designed. In order to confirm operation of semi-implantable hearing device using inductive coupling link, the circuit analysis was performed using PSpice, and the performance was verified by implementing a signal processing board of an available size.

A Study on Selection of Ultrasonic Transducer and Contact Material for Surface Irregularities of Stone Cultural Heritage (석조문화유산의 표면 요철도에 적합한 초음파 탐촉자 및 접촉매질 선정 연구)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.267-278
    • /
    • 2015
  • In this study, the elastomer cover, a new contact material, was developed to establish the customized ultrasonic measurement considering surface irregularities of stone cultural heritages. The cover exhibits high elastic force and wear resistance because it has tensile strength of 17MPa and elongation of 625%. In addition, as a result of comparative experiments for the seven types according to transducers and contact materials including the elastomer cover, rock surface irregularities significantly affect attenuation of ultrasonic velocity. The phenomenon was more noticeable in the chiseling finish and indirect transmission measurement rather than the dabbed finish and direct transmission measurement. However, the Type F using the exponential transducer and elastomer cover showed stable P-wave velocity and high amplitude regardless of the surface irregularities. This because the elastomer cover sufficiently sticks to surface irregularities and removes pores between a transducer and a rock specimen. Therefore, the Type F should be used for the ultrasonic measurement of stone cultural heritages with surface irregularities.

Analysis of the Effects According to Changes in Impedance and Electrical Equivalent Circuit Modeling of a SONAR Transducer Considering Dual Resonance (이중 공진을 고려한 소나 트랜스듀서의 전기적 등가회로 모델링 및 임피던스 변동에 따른 효과 분석)

  • Mok, Hyung-Soo;Choi, Jae-Hyuk;Han, Soo-Hee;Park, Sang-Zoon;Kim, Sung-Joo;Heo, Jun-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.144-151
    • /
    • 2015
  • The present study proposes a method for modeling a SONAR transducer with dual resonance. The Butterworth van-Dyke (BVD) model, a conventional SONAR transducer modeling method, can model only one resonance point. Hence, to address its disadvantage and to model the dual resonance, a dual resonance BVD model consisting of two serial BVD models is proposed. The two BVD models are connected in a series, and each simulate resonance at low frequency and high frequency, which allows the modeling of two resonance points. Eight elements compose the equivalent circuit by connecting the BVD models in a series, which is twice as great as that of the existing BVD model. The element value of the dual resonance BVD model is extracted by using the particle swarm optimization method. Analysis was also performed to identify the effects of changes in the value of elements that compose the equivalent circuit on the impedance characteristics of the equivalent circuit through simulation in which element values varied.

Design of Dual-band Ortho-mode Transducer for Ka-band VSATs (Ka 대역 VSAT용 이중대역 직교모드변환기 설계)

  • Lee, Hongyeol;Uhm, Manseok;Yun, Sohyeun;Yom, Inbok;Kim, Hyunsoo;Park, Jeongwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.47-51
    • /
    • 2013
  • In this paper, we present design and test results of a Ka-band dual-band ortho-mode transducer (OMT) for use in a feed assembly for the very small aperture terminals (VSATs). The designed ortho-mode transducer have wideband characteristics to separate the signals that have two orthogonal linear polarizations operating at 20GHz of receive frequency band and at 30GHz of transmit frequency band. In addition, in order to reduce the volume of the feed assebly, a Boifot based ortho-mode transducer has been designed with a dual-band. Experimental results for the design verification, the return loss in the receive band and in the transmit band for the horizontal polarization showed over 20dB and 21dB, respectively, and for the vertical polarization showed over 20dB and 24dB, respectively. The port isolation for the horizontal polarization and the vertical polarization showed over 43dB and 52dB, respectively, in the receive band and in the vertical band.

Lumped Model Parameter Estimation of Floating Mass Transducers based on Sequential Quadratic Programming Method for IMEHDs (Sequential Quadratic Programming 방법을 이용한 인공중이용 플로팅 매스 트랜스듀서의 집중 모델 파라미터 추정)

  • Park, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • In this paper, the lumped element model parameter estimation method and its implemented estimation software for fabricated floating mass transducers of IMEHDs have been presented so that the estimated parameter values could be compared with the designed ones and applied to predict the output performance when the transducers were implanted into human ears. The presented method is based on the sequential quadratic programming (SQP) for estimating parameters in the transducer's lumped model and has been implemented by the use of LabVIEW graphical language. Using the implemented estimation software, the accuracy of parameter estimation has been verified and our implemented estimation method has been evaluated by the comparison of the estimated transducer parameter values with the designed ones for a practically fabricated floating mass transducer for IMEHDs.