• Title/Summary/Keyword: TRANSDUCER

Search Result 2,040, Processing Time 0.023 seconds

Design and Fabrication of Multi-mode Wideband Tonpilz Transducers (다중모드 광대역 Tonpilz 트랜스듀서의 설계 및 제작)

  • Kim, Jinwook;Kim, Hoeyong;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.191-198
    • /
    • 2013
  • In this paper, we designed a wideband Tonpilz transducer, and verified the validity of the design through experiments. The wide frequency bandwidth was achieved by coupling the fundamental longitudinal mode of the transducer with a flapping mode of the head mass. Structure of the Tonpilz transducer was optimized by means of the finite element method and genetic algorithm to achieve the widest fractional bandwidth under design constraints. The optimized structure showed a far wider -6 dB fractional bandwidth of transmitting responses than that of single mode transducers. For verification of the design result, we manufactured a transducer prototype of the designed structure and characterized its performance, which showed good agreement with the design results.

Design and Implementation of a Vibration Transducer based on PZT Multi-layered Actuator for Implantable Middle Ear Hearing Devices (PZT 적층 압전체 기반의 인공중이용 트랜스듀서 설계 및 구현)

  • Park, I.Y.;Jung, E.S.;Seong, K.W.;Kim, M.W.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recently, implantable middle ear hearing devices (IMEHDs) have been developed to overcome the problems of conventional hearing aids. In this paper, a piezoelectric floating mass transducer (PFMT) based on a PZT multi-layered actuator has been designed and implemented using the approximated mechanical vibration modeling for the PFMT and the analysis of vibration characteristics through the transformation into the equivalent electrical model. The implemented PFMT has been attached to the ossicle of a human cadaver's temporal bone and the in-vitro experiment has been performed. Through the experimental results, it has been verified that the PFMT applied into our developed implantable middle ear hearing device can be used for an IMEHD transducer.

  • PDF

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.

A Study on the Design and Fabrication of Fat Emulsification Adapted Focused Ultrasonic Transducer (지방 조직 유화를 위한 집속형 초음파 변환기 설계 및 제작에 관한 연구)

  • Kim, Ju-Young;Kim, Jae-Young;Jung, Hyun-Du;Noh, Si-Cheol;Mun, Chang-Su;Mun, Chi-Woong;Choi, Heung-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.127-134
    • /
    • 2015
  • Tissue stimulation technique using ultrasound has been continuously studied and developed. Recently, as a increment of interests for obesity treatment and cosmetic care, a various studies on ultrasonic fat emulsification has been conducted. In this study, the fat emulsification adapted ultrasonic transducer was designed. And using designed transducer, the simulation for the shape of focal area and thermal degradation region was conducted. The dimensions were verified by the simulation results. And the effectiveness was confirmed by evaluating measured radiation characteristic and heating characteristic. In addition, we estimated the ultrasonic heating characteristics in composite structure medium. The shape of focal point and heating characteristic of the proposed transducer were determined to be sufficient to emulsify the fat. The results of this study are considered to be used as basic research in more efficient and safe ultrasonic fat removal.

Design of the broadband pattern of a cymbal transducer array (심벌 트랜스듀서 배열의 광대역 패턴 설계)

  • Kim, Donghyun;Oh, Changmin;Shim, Hayeong;Kang, Soonkwan;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.10-17
    • /
    • 2021
  • The cymbal transducer is a miniaturized version of the Class V flextensional transducer. It has low resonant frequency and high output pressure characteristics compared with its size. However, since it has high quality factor and low energy conversion efficiency as well, it is often used as an array rather than single. When used as an array, a big change in the frequency characteristics occurs in comparison with that of the single transducer due to the interaction between constituent transducers. In this study, we designed a pattern of cymbal array with a view to having broadband characteristics. Three transducers having different center frequencies were designed first. The designed cymbal transducers were used to construct all possible patterns of a 3 × 3 planar array. After analyzing frequency characteristics of these patterns, based on the results, we derived the most effective pattern to achieve a higher fractional bandwidth. The derived array pattern showed an improvement of the fractional bandwidth by 24.9 % in comparison with the reference model.

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.

Weighted Finite State Transducer-Based Endpoint Detection Using Probabilistic Decision Logic

  • Chung, Hoon;Lee, Sung Joo;Lee, Yun Keun
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.714-720
    • /
    • 2014
  • In this paper, we propose the use of data-driven probabilistic utterance-level decision logic to improve Weighted Finite State Transducer (WFST)-based endpoint detection. In general, endpoint detection is dealt with using two cascaded decision processes. The first process is frame-level speech/non-speech classification based on statistical hypothesis testing, and the second process is a heuristic-knowledge-based utterance-level speech boundary decision. To handle these two processes within a unified framework, we propose a WFST-based approach. However, a WFST-based approach has the same limitations as conventional approaches in that the utterance-level decision is based on heuristic knowledge and the decision parameters are tuned sequentially. Therefore, to obtain decision knowledge from a speech corpus and optimize the parameters at the same time, we propose the use of data-driven probabilistic utterance-level decision logic. The proposed method reduces the average detection failure rate by about 14% for various noisy-speech corpora collected for an endpoint detection evaluation.

A Study on an Ultrasonic Phased Array Transducer with a Spherical Liquid Lens (구면 액체 렌즈 초음파 위상 배역 변환기에 관한 연구)

  • 윤영중;박한규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.11
    • /
    • pp.9-16
    • /
    • 1995
  • In this paper, an ultrasonic phased array transducer with spherical liquid lens, which utilizes both electronic focusing by linear phased array and variable geometric focusing by spherical lens. is investigated. This system reduces the elevational beamwidth which is disadvantage of the 1-dimensional linear phased array, and adds real-time dynamic focusing capability by controlling the volume of liquid in the lens. A prototype of this transducer is constructed and tested. The experimental results are compared with those of computer simulations. The range of applications are in the hyperthermia applicators or ultrasonic image system with narrow beam and rapid scanning characterisitcs.

  • PDF

Analysis of the Cross Talk Mechanism in Capacitive Micromachined Ultrasonic Transducers

  • Rho, Yongrae;Khuri-Yakub, Butrus T.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3E
    • /
    • pp.31-37
    • /
    • 2001
  • Finite element model of a cMUT is constructed using the commercial code ANSYS to analyze the cross talk mechanism. Calculation results of the complex load impedance seen by single capacitor cells are presented, and then followed by a calculation of the plane wave real load impedance seen by a parallel combination of many cells that are used to make a transducer. Cross talk between 1-D array elements is found to be due to two main sources: coupling through a Stoneley wave propagating at the transducer-water interface and coupling through Lamb waves propagating in the substrate. To reduce the cross talk level, the effect of various structural variations of the substrate are investigated, which include a change of its thickness and etched trenches or polymer walls between array elements.

  • PDF

A Study on the Frequency Characteristics of a Class IV Flextensional Transducer (Class IV Flextensional 트랜스듀서의 주파수 특성 변화에 관한 연구)

  • 강국진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.7
    • /
    • pp.67-73
    • /
    • 1999
  • We constructed a class Ⅳ Flextensional transducer, and analyzed the effects of the variation in its material properties and structure on the resonance frequency of the transducer. We used the FEM for the analysis. Major axis length, minor axis length, thickness and material properties of the shell turned out to have large effects, while volume of the insert material, material properties and thickness of the ceramic bar have little. Thickness of the nodal-plate has no effect on the resonance frequency. Results of the present work can be utilized to design Class W Flextensional transducers of various resonance frequency.

  • PDF