• 제목/요약/키워드: TRANSDUCER

검색결과 2,038건 처리시간 0.027초

적출 심근의 칼륨경축에 대한 칼슘이온 효과 (Effect of $Ca^{++}$ on High K-induced Contracture of Isolated Frog Ventricular Muscle)

  • 최윤백;김기환
    • The Korean Journal of Physiology
    • /
    • 제20권1호
    • /
    • pp.31-41
    • /
    • 1986
  • The sufficient myoplasmic $Ca^{++}$ to react with the contractile proteins is necessary to induce contraction of a cardiac muscle. These $Ca^{++}$ for the production of muscle contraction are supplied from the three recognized $Ca^{++}$ sources; internal $Ca^{++}$ release via the sarcoplasmic reticulum(SR), $Ca^{++}$ influx through a gated Ca-channel in the membrane as a Isi, and $Ca^{++}$ transport by the mechanism of Na/ca exchange. However, it is still controversial which $Ca^{++}$ sources act as a main contributor for myoplasmic $Ca^{++}$, Therefore, this study was undertaken in order to examine the $Ca^{++}$ sources for the contraction of frog ventricle. There is evidence that the SR is sparse in frog ventricular fibers, and that T-tubules are absent. Isolated ventricular strips of frog, Rana nigromaculata, were used in this experiment. Isometric tension was recorded by force transducer, and membrane potentials of ventricular muscles were measured through the intracellular glass microelectrodes, which were filled with 3M KCI and had resistance of $30{\pm}50M{\Omega}$. All experiments were performed at room temperature in a tris·buffered Ringer solution which was aerated with 100% $O_2$. Isotonic high K, low Na solution was used to induce K-contracture, K-contracture appeared at the concentration of 20 to 30mM-KCI and was potentiated in parallel with the increase in KCI concentration. The contracture had two components: an initial rapid phasic and a subsequent slow tonic contractile responses. Membrane Potentials measured at normal Ringer solution(2.5mM KCI) was -90 to -100 mV, and decreased linearly as the KCI concentration increased; -55mV at 20mM.KCI, -45mV at 30 mM.KCI, -30 mY at 50 mM.KCI, and -12 mV at 100 mM.KCI. K-contracture was evoked firstly at the membrane potential of -45 mV. The contracture was potentiated by the increase of bathing extracellular $Ca^{++}$ concentration. However, in the absence of $Ca^{++}$ the contracture was almost not induced by 50 mM.KCI solution. Caffeine(20mM) in normal Ringer solution, which is known to release $Ca^{++}$ from SR without substantial effects on the $Ca^{++}$ fluxes across the surface membrane, did not affect membrane potential and also not initiate contracture, but the caffeine in 20 mM-KCI Ringer solution produced a contracture. Above results suggest that the main $Ca^{++}$ source for the K·contracture of frog ventricle is $Ca^{++}$ influx through the voltage-dependent Ca-channel, and that in the K-contracture at the concentration of 100 mM-KCI, the mechanism of Na/ca exchange also partly contributs, in addition to the $Ca^{++}$ influx.

  • PDF

Clostridium difficile Toxin A Inhibits Erythropoietin Receptor-Mediated Colonocyte Focal Adhesion Through Inactivation of Janus Kinase-2

  • Nam, Seung Taek;Seok, Heon;Kim, Dae Hong;Nam, Hyo Jung;Kang, Jin Ku;Eom, Jang Hyun;Lee, Min Bum;Kim, Sung Kuk;Park, Mi Jung;Chang, Jong Soo;Ha, Eun-Mi;Shong, Ko Eun;Hwang, Jae Sam;Kim, Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권12호
    • /
    • pp.1629-1635
    • /
    • 2012
  • Previously, we demonstrated that the erythropoietin receptor (EpoR) is present on fibroblasts, where it regulates focal contact. Here, we assessed whether this action of EpoR is involved in the reduced cell adhesion observed in colonocytes exposed to Clostridium difficile toxin A. EpoR was present and functionally active in cells of the human colonic epithelial cell line HT29 and epithelial cells of human colon tissues. Toxin A significantly decreased activating phosphorylations of EpoR and its downstream signaling molecules JAK-2 (Janus kinase 2) and STAT5 (signal transducer and activator of transcription 5). In vitro kinase assays confirmed that toxin A inhibited JAK 2 kinase activity. Pharmacological inhibition of JAK2 (with AG490) abrogated activating phosphorylations of EpoR and also decreased focal contacts in association with inactivation of paxillin, an essential focal adhesion molecule. In addition, AG490 treatment significantly decreased expression of occludin (a tight junction molecule) and tight junction levels. Taken together, these data suggest that inhibition of JAK2 by toxin A in colonocytes causes inactivation of EpoR, thereby enhancing the inhibition of focal contact formation and loss of tight junctions known to be associated with the enzymatic activity of toxin A.

필름 스피커 적용을 위한 PZT/polymer 복합체의 후막 제조 및 압전 특성 평가

  • 손용호;어순철;김성진;권성열;권순용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.346-346
    • /
    • 2007
  • 압전세라믹 재료는 현재 압전 변압기, actuator, transducer, sensor, speaker 등에 광범위하게 이용이 되고 있다. 이 중에서 압전세라믹 소결체를 이용한 스피커의 제조는 가공이 까다롭고, 대형의 크기로 제작 시 소자가 깨지는 등의 많은 제약을 받고 있으며, 저음 특성이 떨어져 응용 범위가 한정되어 있다. 따라서 최근에는 이러한 단점을 극복하기 위하여 세라믹/고분자 복합체를 이용한 필름 스피커를 제작하고자 시도하고 있다. 이러한 세라믹/고분자 0-3형 압전 복합체를 이용할 경우, 제품의 경량화를 실현할 수 있고, 크기나 환경의 영향을 거의 받지 않으므로, 고기능성 스피커로의 응용에 적합할 것으로 보인다. 따라서 본 연구에서는 PZT계의 세라믹와 PVDF, PVDF-TrFE, Polyester, acrylic resin 등의 여러 고분자 물질과의 복합체를 제조하여 압전특성을 평가하였다. 본 실험은 먼저 $(Pb_{1-a-b}Ba_aCd_b)(Zr_xTi_{1-x})_{1-c-d}(Ni_{1/3}Nb_{2/3})_c(Zn_{1/3}Nb_{2/3})_dO_3$ (이하 PZT라 표기)의 최적화 조성을 선택하여, $1050^{\circ}C$에서 소결된 분말을 48시간 ball milling방법 로 약 $1{\mu}m$ 크기로 분쇄하였다. 고분자 물질들은 알맞은 용제들을 선택하여 녹였다. 그 다음 소결된 PZT분말과 고분자를 50:50, 60:40, 65:35, 70:30등의 무게 분율로 혼합하고, 분산제, 소포제 등을 첨가하여 3단 roll mill을 이용하여 충분히 분산시켜 페이스트 (Paste)를 제조하였다. 제조된 페이스트를 ITO가 코팅된 PET필름 위에 스크린 프린팅 법을 사용하여 인쇄하여 $120^{\circ}C$에서 5분간 건조하였다. 코팅된 복합체의 두께는 약 $80{\mu}m$ 정도로 측정되었다. Ag 페이스트를 이용한 상부 전극 형성에도 스크린 프린팅 법을 적용하였다. 이를 $120^{\circ}C$에서 4 kV/mm의 DC 전계로 분극 공정을 수행한 후 전기적 특성을 평가하였다. 유전특성을 조사하기 위해서 LCR meter (EDC-1620)를 사용하였고, 시편의 결정구조는 XRD (Rigaku; D/MAX-2500H)을 통해 분석하였으며, 전자현미경(SEM)을 이용하여 미세구조를 분석하였다. 압전 전하상수$(d_{33})$ 값은 APC 8000 모델을 이용하여 측정하였다. PZT의 혼합비가 증가할수록 비유전율 및 압전 전하 상수 등의 전기적 특성이 증가되었다. 또 여러 고분자 물질 중에서 PVDF-TrFE 수지가 가장 우수한 특성을 보였다. 이는 PVDF-TrFE 수지가 압전성을 나타내기 때문인 것으로 판단되었다.

  • PDF

압전 세라믹을 이용한 전기 발전 (Electric Power Generation from Piezoelectric Ceramics)

  • 백종후;신범승;임은경;김창일;임종인;이영진;최병현;김동국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.304-304
    • /
    • 2006
  • 기계적 에너지를 전지적 에너지로 변환하는 에너지 변환소자인 압전 세라믹스는 액츄에이터, 변압기, 초음파모터, 초음파 소자 및 각종 센서로 응용되고 있으며, 그 응용분야는 크게 종가하고 있다. 최근 이러한 에너지변환 소자를 앞으로 도래하는 유비쿼터스 무선 모바일 시대의 휴대용 전자제품, 즉 Wearable 컴퓨터, MP3, GSM, Bluetooth 등의 정보통신기기, Robotics, 항공우주, 자동차, 의료, 건축, MEMS 분야 등의 대체 에너지원으로 응용하기 위한 연구가 진행되고 있다. 특히 인간의 동작등과 같은 일상적인 동작(Typing, U. limbbing, Breathing, Walking 등)으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수가 있어서, 기존 이차전지, 연료전지를 대체 또는 보완 할 수 있는 방안도 검토되고 있다. 따라서 본 연구에서는 향후 응용 가능성이 큰 압전 발전 시스템을 제작하기 위해서 압전특성이 우수한 조성시스템 설계, 바이몰프 형태의 압전액츄에이터 제작, 그리고 발전시스템의 회로설계를 수행하였다.

  • PDF

성형외과 영역에서 이물질 주사에 대한 고해상초음파 검사의 유용성 (Usefulness of High-Resolution Ultrasonography after Foreign Body Injection on Aesthetic Plastic Surgery)

  • 고응열;성하민;조건;박영규;탁경석;서인석;양익
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.385-390
    • /
    • 2010
  • Purpose: The purpose of this study is to demonstrate the usefulness of the high resolutional ultrasonographic features in patients with foreign body. Methods: From September 2007 to August 2009, we retrospectively reviewed high resolutional ultrasonogram using 5~12 MHz linear transducer of 13 patients presenting with inflammation after foreign body injection. They were referred for complications after foreign body injection. Injected foreign bodies were 4 silicone, 4 paraffin, 2 artecoll, and 3 unknown. We treated them with foreign body removal (7), foreign body removal and corrective plastic surgery (4), and conservative treatment with antibiotics and steroid injection (2). Results: High resolutional ultrasonography well demonstrated the existence of foreign body and it's overall size, location within the tissue layer, and vascularity. Comparison between preoperative and postoperative ultrasonographic findings was useful not only to evaluate the prognosis but also to plan the treatment. These ultrasonographic findings aided in precise assessment of the contour and location of the foreign body and led to an accurate surgery. We were able to acquire various information in order to set a detailed plan for the operation which in turn, led to a precise, successful surgery. After the treatment, complication did not occur in 12 patients, except 1 patient. But this patient was also treated after reoperation. Postoperative high resolutional ultrasonography shows almost foreign body removed and inflammation disappeared. Conclusion: Considering the usefulness of highresolution ultrasonography in foreign body injection, highresolution ultrasonography would be necessary for both the patient and the doctor. Preoperative and postoperative high resolutional ultrasonography is highly accurate, safe, inexpensive and easy. It can be a useful modality in foreign body after plastic surgery.

구순열 수술 후 인중의 변형과 구륜근 결손 (Oribicularis Oris Muscle Defects in Philtral Deformities in the Repaired Cleft Lip)

  • 김석화;정연우;천정은;박찬영;오명준;김정홍;최태현
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.427-432
    • /
    • 2010
  • Purpose: The purpose of this study is to estimate muscle defect by ultrasonography in the patients with secondary deformities of the lip. We investigated the association between the muscle defect in the repaired cleft lip and the philtral appearance not only at resting state but also maximal puckering. Methods: From December 2006 to November 2007, 52 children were evaluated after primary or secondary cheiloplasty. Digital photographs were taken both from the front and both three quarter views in repose and at maximal pucker. Video clips were also taken in repose and at maximal pucker. A panel of four, scored the philtral ridge and dimple seen on these photographs and videos by using two visual analog scales. Eminence of the philtral ridge was scored by a 5 point grading scale, from "conspicuous groove" to "normal philtral ridge" and the philtral dimple was scored by 3 point grading scale, from "no dimple" to "prominent dimple". Ultrasound images of the upper lip were made using a linear array transducer at the resting position of the lip and evaluated by a single radiologist. Results: The philtral ridge eminence scored $2.79{\pm}0.54$ and $1.40{\pm}0.53$ at resting and maximal pucker, correlating with "flat" and "conspicous groove". The philtral dimpling scored $1.44{\pm}0.53$ and $2.27{\pm}0.66$ at resting and maximal pucker, correlating with "no dimple" and "slight dimple". Ultrasound imaging showed the average muscle dehiscence to be $3.78{\pm}2.14$ mm at resting position. Correlation between the muscle defect in ultrasound imaging and philtral ridge eminence at rest was statistically significant (p<0.050), but was not significant (p=0.756) at maximal pucker using Spearman's rank correlation. Correlation between the muscle defect in ultrasound imaging and philtral dimpling was not statistically significant both at rest (p=0.920) and at maximal pucker (p=0.815) using Spearman's rank correlation. Conclusion: Quantitative assessment of the muscle defect using ultrasonography correlates with the static philtral appearance, but does not correlate with the dynamic appearance. Also, the size of the muscle defect does not show any correlation with the philtral dimpling. Our findings reveal that ultrasound imaging partially reflect static appearance of philtrum but cannot reflect dynamic appearance and suggest the need for further research to evaluate dynamic appearance.

와이어 본딩용 초음파 혼의 진동 특성 (Vibration Characteristics of a Wire-Bonding Ultrasonic Horn)

  • 김영우;임빛;한대웅;이승엽
    • 대한기계학회논문집A
    • /
    • 제38권2호
    • /
    • pp.227-233
    • /
    • 2014
  • 본 논문은 상용화된 와이어 본딩용 초음파 혼 시스템에서 발생하는 와이어 본딩 불량의 원인을 진동해석을 통하여 파악하고자 한다. 먼저 링 형상의 압전 구동기와 초음파 혼 그리고 캐필러리 등 각 부품의 진동 특성과 136kH의 가진 주파수 근처에서 발생하는 전체 초음파 혼 시스템의 주요 진동 모드들을 유한요소해석을 이용하여 구하였다. 136kHz에서 공진되는 전체 트랜스듀서 시스템의 진동 모드가 종진동 모드가 아닌 굽힘 진동 모드임을 조화 가진 해석과 실험으로 확인하였다. 136kHz에서 발생하는 굽힘 진동 모드는 캐필러리 끝단의 움직임이 종방향 뿐만 아니라 좌우 횡방향으로도 큰 변위가 발생하기 때문에 정밀 작업 시 본딩 불량의 원인이 될 수 있다. 가진 주파수 대역 근처인 119kHz에서 발생하는 종진동 모드는 캐필러리의 횡방향 진동이 감소하기 때문에 본딩 성능의 향상을 위해서 이러한 종진동 모드를 이용하도록 설계 변경이 필요함을 제시하였다.

전립선 암세포에서 delphinidin에 의한 HIF-1α와 STAT3 억제를 통한 혈관내피 성장 인자 발현 저해 효과 (Delphinidin Suppresses Angiogenesis via the Inhibition of HIF-1α and STAT3 Expressions in PC3M Cells)

  • 김문현;김미현;박영자;장영채;박윤엽;송현욱
    • 한국식품과학회지
    • /
    • 제48권1호
    • /
    • pp.66-71
    • /
    • 2016
  • 델피니딘은 양전하를 뛰는 diphenylpropane의 polyphenolic ring 구조를 가진 주요한 안토시아닌 색소 중에 하나이다. 최근 연구에서 델피니딘은 항산화, 항염증 뿐만 아니라 항암 효능을 가진다고 보고되었다. 본 연구에서는 전립샘 암에서 종양의 성장과 신생혈관생성에 관련된 중요한 인자인 VEGF 발현에 대한 델피니딘의 억제 효과를 조사하였다. RT-PCR을 통해 델피니딘을 처리한 PC3M 전립샘 암세포 세포에서 EGF로 유도한 VEGF mRNA 발현 수준이 감소됨을 확인하였다. 또한 델피니딘은 VEGF의 전사인자인 HIF-$1{\alpha}$와 STAT3가 세포 핵으로 전위되는 것을 효과적으로 억제하였다. 한편 luciferase assay을 통해 HRE-promoter 활성을 확인해 본 결과, 델피니딘이 HIF-$1{\alpha}$의 전사 활성을 억제시켜 VEGF 발현을 감소시키는 것을 알 수 있었다. 그리고 델피니딘은 EGFR의 발현에는 영향을 미치지 않고, Akt, p70S6K, 4EBP1의 인산화를 특이적으로 억제하는 것으로 나타났다. 결론적으로 델피니딘이 HIF-$1{\alpha}$와 STAT3, VEGF 발현을 억제를 통하여 암세포 증식억제와 신생혈관형성을 억제하는 역할을 새롭게 확인하였다.

퍼스널 컴퓨터를 이용한 칼라 어군탐지기의 개발에 관한 연구 (Development of the PC Based Color Fish Finder)

  • 신현옥
    • 수산해양기술연구
    • /
    • 제31권3호
    • /
    • pp.247-255
    • /
    • 1995
  • 판되고 있는 어군탐지기는 칼라 모니터를 사용하든 기록지를 사용하든 현장에서 관측한 에코 데이터의 저장과 재생하는 기능이 없는 경우가 대부분이고, 어군탐지기의 기능은 제조회사에 의해 정하여져 있어 확장성이 약하다. 본 연구에서는 이 문제를 해결하는 하나의 방안으로 퍼스널 컴퓨터(386DX, 20 MHz), 디지털 I/O 보드, 동시 샘플링형 A/D 보드(12bit, 15 $\mu$sec/ch) 및 초음파 송수신 보드를 사용하여 어군탐지 정보의 저장과 재생이 자유롭고 확장성이 뛰어난 마스터형 칼라 어군탐지기를 개발하였고, 그 성능을 확인하는 실험을 행하였다. 또한, 퍼스널 컴퓨터와 A/D 보드를 이용하여 타 어군탐지기로부터의 신호를 입력하여 칼라 에코그램으로 재생할 수 있는 슬레이브형 칼라 어군탐지기를 개발하여 그 성능을 확인하는 실험도 행하였다. 에코신호의 샘플링 간격은 0.1m, A/D 변환속도는 30$\mu$sec로 하였다. 마스터형에서는 초음파 송수신 보드만 갖추면 사용자의 용도에 알맞은 칼라 어군탐지기를 구성할 수 있음을 공기중 실험 및 수조 실험에서 확인하였으며, 슬레이브형에서는 타 어군탐지기로 부터의 신호를 퍼스널 컴퓨터에 입력하여 재생할 수 있음을 확인할 수 있었다. 이 실험 결과로부터 본 연구에서 개발한 마스터형 칼라 어군탐지기는 사용자의 용도에 적합하게 개량할 수 있어 다양한 분야에 응용할 수 있을 것으로 기대된다. 슬레이브형에서는 에코 시뮬레터를 연결한 기록식 어군탐지기의 기록과 이 어군탐지기의 수신부에서 출력되는 에코 신호 및 트리거 신호를 시험 제작한 어군탐지기에 입력시켜 신호 처리한 칼라 에코그램을 비교한 결과, 해저 수심, 어군 등의 에코 기록이 완전히 일치하면서 해상력이 뛰어났으며, 키보드의 기능키에 할당된 에코그램의 shift 기능, 화면상의 최대 표시 심도 조정 기능, gate 기능 등이 정상적으로 작동함을 획인할 수 있었다. 자원조사용 어군탐지기의 에코 신호를 데이터 로거에 기록한 후 이 데이터를 본 연구에서 개발한 어군탐지기로 재생하는 실험을 행한 결과, 양호하게 재생할 수 있었으며, 무선 송수신기를 이용하여 에코 시뮬레이터의 신호를 원격으로 수신 처리한 결과도 양호하였다. 따라서, 슬레이브형 어군 탐지기는 흑백 기록식 어군탐지기를 이용하여 칼라 에코그램을 나타내는 상업용으로 혹은 어류 자원을 조하고 관리하기 위한 학술 연구용으로 활용될 수 있을 것으로 기대된다.

  • PDF

요추부 협착증 치료를 위한 극돌기 삽입술의 생체역학적 효과 분석 (A Biomechanical Analysis of an Interspinous Distraction Device for Treatment of Lumbar Spinal Stenosis)

  • 이희성;첸웬밍;송동률;권순영;이권용;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.210-217
    • /
    • 2006
  • Many types of interspinous distraction devices (IDDs) have been recently developed as an alternative surgical treatment to laminectomy and fusion with pedicle screws for the treatment of the lumbar spinal stenosis (LSS). They are intended to keep the lumbar spine in a slightly flexed posture to relieve pain caused by narrowing of the spinal canal and vertebral foramen. However, their biomechanical efficacies are not well known. In this study, we evaluated the kinematic behaviors and changes in intradiscal pressure (IDP) of the porcine lumbar spine implanted with IDD. For kinematics analysis, five porcine lumbar spines (L2-L6) were used and the IDD was inserted at L4-L5. Three markers (${\phi}{\le}0.8mm$) were attached on each vertebra to define a rigid body motion for stereophotogrammetric assessment of the spinal motion in 3-D. A moment of 7.5Nm in flexion-extension, lateral bending, and axial rotation were imparted with a compressive force of 700N. Then, IDD was implanted at L3-L4. IDPs were measured using pressure transducer under compression (700N) and additional extension moment (700N+7.5Nm). In kinematic behaviors, insertion of IDD resulted in statistically significant decrease 42.8% at the implanted level in extension. There were considerable changes in ROM at the adjacent levels, but statistically insignificant. In other motions, there were no significant changes in ROM as well regardless of levels. IDPs at the surgical level (L3-L4) under compression and extension moment decreased by 12.9% and 18.8% respectively after surgery (p<0.05). At the superiorly adjacent levels, IDPs increased by 19.4% and 12.9% under compression and extension, respectively (p<0.05). Corresponding changes at the inferiorly adjacent levels were 29.4% and 6.9%, but they were statistically insignificant (p>0.05). The magnitude of pressure changes due to IDD, both at the operated and adjacent levels, were far less than the previously reported values with conventional fusion techniques. Our experimental results demonstrated the IDDs can be very effective in limiting the extension motion that may cause narrowing of the spinal canal and vertebral foramens while maintaining kinematic behaviors and disc pressures at the adjacent levels.