• Title/Summary/Keyword: TRANSDUCER

Search Result 2,040, Processing Time 0.034 seconds

Scanning Tomographic Acoustic Microscope System by Using Transverse waves

  • Daesik Ko
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2E
    • /
    • pp.21-26
    • /
    • 1997
  • We propose to use transverse waves instead of longitudinal waves in a scanning tomographic acoustic microscope (STAM) and new type of multiple-transducer with the functions of muliple-angle and multiple-frequency tomography. Proposed multiple-transducer scheme has three insonification angles and three resonance frequencies in order to operate in the transverse wave mode and multiple-angle and multiple frequency tomography for the STAM. In order to evaluate the performance of proposed transducer scheme we have simulated tomographic reconstruction with back-and-forth propagation(BFP) algorithm. Simulation results showed proposed multiple-transducer scheme is capable of obtaining good resolution with transverse wave mode and multiple-frequency tomography. It is also showed that proposed scheme is an efficient rotation scheme by proportion to the number of projections.

  • PDF

Simulation of a piezoelectric flextentional sonar transducer using a coupled FE-BEM (결합형 유한요소-경계요소 기법을 사용한 압전체 유연형 쏘나 변환기 시뮬레이션)

  • Jarng, Soon-Suck
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.307-312
    • /
    • 1999
  • A piezoelectric flextentional sonar transducer has been simulated using a coupled FE-BEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with external electrical excitation conditions. Different results are available such as steady-state displacement modes, underwater directivity patterns. It is shown that the present barrel-stave sonar transducer of the piezoelectric material produces flextentional displacements which could be related with higher output power, lower quality factor and more omnidirectional beam pattern than other types of sonar transducers.

  • PDF

Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer (광파이버 트랜스듀서에 의한 맥파의 무침습적 검출)

  • 박승환;정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF

Developed of non-differential pulse detection (비미분형 맥동검출변환기 개발)

  • Kim, H.K.;Han, S.H.;Lee, Y.D.;Park, Y.B.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.573-576
    • /
    • 1998
  • In this paper, we devised pulse detection transducer that has non-differential characteristics for pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever. Therefore the pressure pulse signal can obtain by the developed transducer. As the results of experiment, the developed transducer has a good linearity at pressure to voltage conversion and acan detect non-differential pulse signal from chongu artery.

  • PDF

A characteristic study on the transmisson-reception and fabrication of the ultrasonic transducer using composite with 1-3 connectivity (1-3형 복합재료를 이용한 초음파 Transducer의 제작과 송수신 특성연구)

  • Kim, Chan-Young;Lee, Duck-Chool;Kim, Ho-Gi;Kim, Yong-Huck
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.72-74
    • /
    • 1989
  • A composite with 1-3 connectivity was fabricated by filling spurrs epoxy in arried PZT bars. The composite bad lower density(2220 Kg/$m^3$), lower dielectric constant, lower piezoelectric coefficient d33(260*$10^{12}$ C/N), and higher voltage coefficient(110.1*$10^{-3}$ Vm/N) than that of solid PZT. The probe was fabricated by using composite transducer that was made above. The underwater testing of the composite transducer was performed with water backing.

  • PDF

A Characteristic of Linear Ultrasonic Motor using Langevin Type Transducer (Langevin 진동자를 이용한 선형 초음파 모터의 특성)

  • Seo, San-Dong;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.627-630
    • /
    • 2004
  • Transducer for linear ultrasonic motor with symmetric and anil anti-symmetric modes was studied. The transducer was composed of two Langevin-type vibrators that cross at right angles with each other at tip. In order to excite two vibration modes, two Langevin-type vibrators must have 90-degree phase difference with each other. As a result, tip of transducers moves in elliptical motion. Elliptical trajectoric of transducer was analyzed by employing the finite element method. From these results, the ultrasonic motor was fabricated and was measured for characteristics. In this paper compared an ANSYS analysis with an experiment results. The no-road maximum speed was 113.1[cm/s].

  • PDF

Study on the Level Limit Switch Using a Self Made 1-3 type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 레벨Limit스위치에 관한 연구)

  • Park, K.I.;Kim, H.G.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.756-759
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with a 1-3 type composite resonator. Pulse-echo responses of an ultrasonic transducer are investigated in underwater with the designated water-levels. LED output signals of a level limit switch with changing a water level are obtained by using the currently developed self-made 1-3 type composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level.

  • PDF

Design and Acoustic Properties of Piezoelectric Device with the PMN-PT-PZ System (PMN-PT-PZ계를 이용한 압전소자의 설계 및 음향특성)

  • Go, Young-Jun;Seo, Hee-Don;Nam, Hyo-Duk;Chang, Ho-Gyeong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.283-286
    • /
    • 2000
  • In this study, the acoustic transducer of a thin circular disc-type with PZT/Metal was manufactured. The piezoelectric transducer with 200kHz resonance frequency was designed by considering the sharp directivity and the sound pressure. The dielectric and piezoelectric properties of 0.5 weight percent $MnO_2$ and NiO doped $0.1Pb(Mg_{1/3}Nb_{2/3})O_3-0.45PbTiO_3-0.42PbZrO_3$ ceramics were investigated aiming at acoustic transducer applications. Also, the acoustic characteristics of a thin circular disc-type with metal-piezoceramics have been Investigated.

  • PDF

A Study on the Frequency Characteristics of a Class I Flextensional Transducer (Class I Flextensional 변환기의 주파수 특성에 관한 연구)

  • Kang, Kook-Jin;Lee, Young-Jin;Paik, Jong-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.226-227
    • /
    • 2008
  • We constructed a class I Flextensional transducer, and analyzed the variation of the resonance frequency of the transducer in relation to its design variables. We used the FEM for the analysis. Major axis length, minor axis length, thickness and material properties of the shell have large effects on the resonance frequency. In addition, the validation of the FE model was verified by manufacturing and comparison of the impedance analysis.

  • PDF

A Study on Design of Underwater Acoustic Transducers Using the Electro-mechanical Coupling Analysis Code ATILA (전기-기계 연성해석 코드 ATILA를 이용한 수중 음향 트랜스듀서 설계)

  • Lee, Jeong-min;Cho, Yo-han;Kim, Jung-suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1211-1216
    • /
    • 2005
  • Underwater acoustic transducers are widely used for SONAR application, whose important design parameters are shapes. materials, dimensions and supporting structures. Practical design method of transducers consists of manufacturing, experiments and modifications so that it requires much time and expenses. In this study, an analytical method was developed for the Tonpilz type transducers using the commercial finite element analysis code ATILA which can solve the electro-mechanical coupling problems. A finite element model was established including the transducer elements such as ceramic stack, head mass, tail mass, tensile bolt, and molding layers. The proposed model was verified and modified by comparing the in-air and in-water test results of prototypes. The developed analysis method will be effectively used for the sensitivity analysis of design parameters in transducer design process.