• Title/Summary/Keyword: TRANSDUCER

Search Result 2,038, Processing Time 0.023 seconds

Application of Side Scan Sonar to Disposed Material Analysis at the Bottom of Coastal Water and River (해저 및 하저 폐기물의 분석을 위한 양방향음파탐사기의 적용)

  • 안도경;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.147-153
    • /
    • 2002
  • Due to the growth of population and industrial development at the coastal cities, there has been much increase in necessity to effective control of the wastes into the coastal water and river. The amount of disposal at those waters has been increased rapidly and it is necessary for us to track of it in order to keep the water clean. The investigation and research related to the water quality in this region have been conducted continuously but the systematic survey of the disposed wastes at the bottom was neglected and/or minor. In this study we surveyed the status of disposed waste distribution at the bottom coastal water and river from the scanned images. The intensity of sound received by the side scan sonar tow vehicle from the sea floor provides information as to the general distribution and characteristics of the superficial wastes. The port and starboard side scanned images produced from a transducer borne on a tow fish connected by tow cable to a tug boat have the area with width of 22m∼112m, and band of 44m∼224m. All data are displayed in real-time on a high-resolution color display (1280 ${\times}$ 1024 pixels) together with position information by DGPS. From the field measurement and analysis of the recorded images, we could draw the location and distribution of bottom disposals. Furthermore, we made a database system which might be fundamental for planning the waste reception and process control system.

  • PDF

Systematic Identification of Hepatocellular Proteins Interacting with NS5A of the Hepatitis C Virus

  • Ahn, Ji-Won;Chung, Kyung-Sook;Kim, Dong-Uk;Won, Mi-Sun;Kim, Li-La;Kim, Kyung-Shin;Nam, Mi-Young;Choi, Shin-Jung;Kim, Hyoung-Chin;Yoon, Mi-Chung;Chae, Suhn-Kee;Hoe, Kwang-Lae
    • BMB Reports
    • /
    • v.37 no.6
    • /
    • pp.741-748
    • /
    • 2004
  • The hepatitis C virus is associated with the development of liver cirrhosis and hepatocellular carcinomas. Among the 10 polyproteins produced by the virus, no function has been clearly assigned to the non-structural 5A (NS5A) protein. This study was designed to identify the hepatocellular proteins that interact with NS5A of the HCV. Yeast two-hybrid experiments were performed with a human liver cDNA prey-library, using five different NS5A derivatives as baits, the full-length NS5A (NS5A-F, amino acid (aa) 1~447) and its four different derivatives, denoted as NS5A-A (aa 1~150), -B (aa 1~300), -C (aa 300~447) and D (aa 150~447). NS5A-F, NS5A-B and NS5A-C gave two, two and 10 candidate clones, respectively, including an AHNAK-related protein, the secreted frizzled-related protein 4 (SFRP4), the N-myc downstream regulated gene 1 (NDRG1), the cellular retinoic acid binding protein 1 (CRABP-1), ferritin heavy chain (FTH1), translokin, tumor-associated calcium signal transducer 2 (TACSTD2), phosphatidylinositol 4-kinase (PI4K) and $centaurin{\delta}$ 2 ($CENT{\delta}2$). However, NS5A-A produced no candidates and NS5A-D was not suitable as bait due to transcriptional activity. Based on an in vitro binding assay, CRABP-1, PI4K, $CENT{\delta}2$ and two unknown fusion proteins with maltose binding protein (MBP), were confirmed to interact with the glutathione S-transferase (GST)/NS5A fusion protein. Furthermore, the interactions of CRABP-1, PI4K and $CENT{\delta}2$ were not related to the PXXP motif (class II), as judged by a domain analysis. While their biological relevance is under investigation, the results contribute to a better understanding of the possible role of NS5A in hepatocellular signaling pathways.

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Pressure Loss across Tube Bundles in Two-phase Flow (2상 유동 내 관군에서의 압력 손실)

  • Sim, Woo Gun;Banzragch, Dagdan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • An analytical model was developed by Sim to estimate the two-phase damping ratio for upward two-phase flow perpendicular to horizontal tube bundles. The parameters of two-phase flow, such as void fraction and pressure loss evaluated in the model, were calculated based on existing experimental formulations. However, it is necessary to implement a few improvements in the formulations for the case of tube bundles. For the purpose of the improved formulation, we need more information about the two-phase parameters, which can be found through experimental test. An experiment is performed with a typical normal square array of cylinders subjected to the two-phase flow of air-water in the tube bundles, to calculate the two-phase Euler number and the two-phase friction multiplier. The pitch-to-diameter ratio is 1.35 and the diameter of cylinder is 18mm. Pressure loss along the flow direction in the tube bundles is measured with a pressure transducer and data acquisition system to calculate the two-phase Euler number and the two-phase friction multiplier. The void fraction model by Feenstra et al. is used to estimate the void fraction of the two-phase flow in tube bundles. The experimental results of the two phase friction multiplier and two-phase Euler number for homogeneous and non-homogeneous two-phase flows are compared and evaluated against the analytical results given by Sim's model.

Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger (트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.723-729
    • /
    • 2019
  • Turbochargers are an effective device to reduce the fuel consumption. In this study, the mass flow rate of pulsating flow in the twin-scroll turbocharger for the gasoline engine of passenger vehicles was measured. Pulsating flow was achieved using a pulse generator and the mass flow rate of the unsteady pulsating flow was analyzed by comparing it with those of the steady flow. The pulse generator consisted of a rotating upper plate and a fixed lower plate. To measure the mass flow rate of unsteady flow, the orifice flow meter equipped with the difference pressure transducer was used. To analyze the low speed performance of the turbocharger, the measurement was carried out in the speed of turbocharger from 60,000rpm to 100,000rpm. The mass flow parameters of the unsteady pulsating flow showed a large difference compared to those of the steady flow. Those of the unsteady flow showed the hysteresis loop surrounding the mass flow parameters of the steady flow and the maximum variation of the mass flow parameters were 5.0 times those of the steady flow. This phenomenon is the result of the filling and emptying the turbine volute space due to pulsating flow.

The Study on Accuracy Improvement of Estuary Riverbed Monitoring (하구하상 모니터링 정밀도 향상에 관한 연구)

  • Park, Un-Yong;Kim, Yong-Bo;Back, Ki-Suk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.3 s.26
    • /
    • pp.23-34
    • /
    • 2003
  • Currently, the efficiency of GPS has been increased in the various precise survey like as the control survey and the navigation etc. Also, it is widely used in the deformation analysis of the structure, the measurement of the marine tides, the measurement of the river level and the topographic monitoring of seabed or riverbed by combined the measurement equipment for depth. In this study, we intend to increase in efficiency of the topographic monitoring of seabed or riverbed by combined with DGPS, RTK GPS and echo sounder. For this study, we defined the error correction of the echo sounder with the experiment of water tank which is considered the characteristic of estuary riverbed and then we developed the s/w for 3-dimensional monitoring of estuary riverbed and applied the s/w to field test and improved the various problems. On analyzing topography of estuary riverbed by combined GPS with echo sounder, the draught error which is yielded to change of length from the water surface by the movement of survey vessel to the end of the transducer was eliminated by geometrical rearrangement and we defined the correction formula $z=BM+SAH-DBR_{(i)}-DRT-ED$. The sounding error about the echo sounder and characteristic of estuary riverbed was found by understanding the relation of average diameter ind residual error and we defined correction formula, $Y=0.00474{\ast}ln(X)-0.0045$ by the regression analysis. and then we verified applicability of correction formula.

  • PDF

Ultrasonographic Findings in 132 Cases of Renal Disease (신질환(腎疾患) 132례(例)의 초음파진단(超音波診斷))

  • Han, Hye-Jin;Kim, Kang-Sueck
    • The Journal of the Korean life insurance medical association
    • /
    • v.3 no.1
    • /
    • pp.187-208
    • /
    • 1986
  • The conclusions which was acquired one renal cell carcinoma and renal disease 132 cases that was tested renal echogram among 4,499 cases for recent 16 months at medical department, Dae Han Kyoyuk Insurance company from August, 1984 to November, 1985 are as follows: 1. On bur ultrasonography, the echo of tumor was demonstrated with echogenicity as compared with renal parenchyme. 2. The case was stage I by Robson's modification method for pathologic histology. 3. There is no fever, typical triad of renal cell carcinoma and the result of serum biochemical test was within normal limit. 4. The frequency with disease was renal cell carcinoma(0.76%), ureteral stone(1.5%), multicystic kidney(2.27%), hydroureter(2.27%), Bilateral poly cystic kidney(4.55%), hydronephrosis(4.55%), renal agenesis(6.06%) renal calculi(18.18%), simple cyst(60.61%). 5. The frequency with age was 55/1200 case(4.58%) in $41{\sim}50$ years, 13/296 cases(4.39%) in $51{\sim}60$ years, 43/2144 cases(2.01%) in $31{\sim}40$ years, 14/791 cases(1.77%) in $21{\sim}30$ years, 7/53 cases(1.32%) more than 61 years and 0/15(0%) under 20 years. 6. The affected site of renal agenesis 8 cases was right side all. 7. In total renal disease 132 cases, the affected site of 126 cases except bilateral polycystic kidney 6 cases was right kidney 72 cases, left kidney the proportion of right to left 1.6:1 8. In total renal disease 132 cases except bilateral polycystic kidneys 6 cases, the patients affected with both side kidneys were 14 cases. 9. The affection rate with sex in total renal disease 132 cases was 98/2860 cases in male, 34/1819 cases in female and the former was about 2 times than the latter. 10. Classifying the stone with part, nephrolithiasis 24 cases were appeared high frequency, on the contray, ureteral stone 2 cases. 11. 2 cases of ureteral stone developed complication, hydronephrosis and hydroureter. 12. The linear array type transducer was not helpful for the diagnosis of lower ureteral calculi but for the lower ureteral calculi, we could see the stone with high echo in accompanying with acoustic shadowing. 13. In 24 cases of renal calculi, both side nephrolithiasis was 3 cases(12.5%). 14. In renal calculi, solitary stone could be seen extremely much and the number of stone was so much variable from 2 to 10. 15. In 26 cases with renal calculi and ureteral stone, the common clinical manifestation was a intermittent and slight pain. 16. In 80 cases of renal cyst, as one's get older, the affection rate of cyst extremely rised. 17. In bilateral polycystic kidney, large cyst had septum on the whole. 18. The patients with complication were 14 cases(10.6%) of total patients.

  • PDF

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Studies on Accurate Diagnosis on Reproductive Failures of Dairy Cows by Ultrasonography (젖소에서 초음파 검사를 이용한 번식장애 정밀진단에 관한 연구)

  • Kim Yong-Jun;Park Hee-Sub;Kim Yong-Su;Cho Sung-Woo;Shin Dong-Su;Lee Hae-Lee;Kim Sue-Hee
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.133-143
    • /
    • 2006
  • Diagnosis on reproductive failures of dairy cows by ultrasonography was performed for 151 dairy cows. To diagnose types of reproductive failures, ultrasonography (SA 600, Medison, 5.0 MHz rectal linear transducer) was carried out in combination with rectal examination. Of 151 dairy cows, pregnant cows were 13 and the cows in normal estrual cycle were 40 cows, thereby the cows with reproductive failures were 98 cows. 1. Of 98 cows with reproductive failures, the cows with ovarian diseases were 34 cows (34.7%) and the cows with uterine diseases were 41 cows (41.8%). 2. The diameter of follicle in proestrus was 1.94 cm and it was longer than that of follicle in diestrus (p<0.05). 3. The mean size of corpus luteum of pregnant cows was bigger than that of corpus luteum in normal diestrus (p<0.05). 4. The length of cystic corpus luteum was 3.26 and the width of that was 1.91 cm. The length of corpus luteum tissue was 1.95 and the width of that was 1.91 cm excluding the size of cavity in corpus luteum. 5. The mean length of follicular cyst was 3.31 and the mean width of that was 2.3 cm. 6. The mean length and width of luteal cyst was 3.45 and 2.25 cm, respectively. The mean length and width of corpus luteum tissue was 1.15 and 0.67 cm, respectively, excluding the size of cyst in the luteal cyst. 7. The width of uterine horn associated with endometritis was significantly reduced as the period after parturition was elapsed (p<0.05). The mean width of uterine horn within 40 days after parturition was 4.55 cm. These results indicated that ultrasonography is of great use for accurate diagnosis both on ovarian diseases and uterine diseases and that it is very effective to diagnose endometritis in dairy cows.