• Title/Summary/Keyword: TRANSDUCER

Search Result 2,043, Processing Time 0.024 seconds

Development and Calibration of 3-Component Vibration Transducer (3방향 진동감지기의 제작 및 검증)

  • Kim, Dong-Su;Lee, Jin-Seon;Jo, Seong-Ho
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.121-134
    • /
    • 1997
  • Vibrations induced by traffic loading and construction activities are extremely important due to their potential to cause damage to adjacent structures and toy complaints to the neighbors. Vibration induced damage to the built environment may be caused by the direct transmission of vibrations as well as by the, vibration induced differential settlement. In order to effectively control the vibration related problems, the accurate in-situ vibration monitoring is essential. In this paper, a calibration technique of a geophone which is widely used in practice was described. Once the frequency characteristics of individual geophones were calibrated, the 3fomponent geophone was developed for the in-depth vibration measurement, and the dot ailed calibration and application techniques of the 3fomponent geophone were described. Vibrations caused by blasting, train loading, and pile driving were measured and the applicability of the 3fomponent geophone was assessed.

  • PDF

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

A Study on the Fabrication of Piezoelectric Organic Thin Films by using Physical Vapor Deposition Method and Sensor Characteristics (진공증착법을 이용한 압전 유기 박막의 제조와 센서 특성에 관한 연구)

  • Park, Su-Hong;Lim, Eung-Choon;Park, Jong-Chan;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.35-39
    • /
    • 2001
  • The purpose of this paper is improvement the piezoelectric of Polyvinylidene fluoride(PVDF) organic thin films is fabricated by vapor deposition method. The piezoelectric of PVDF organic thin films attributed to dipole orientation in crystalline region. Also, the piezoelectric characteristic reduced that dipole moments orientation in crystalline region interfered with impurity carriers. Therefore, PVDF organic thin films fabricated with high substrate temperature condition for crystallinity improvement. The crystallinity of PVDF organic thin films fabricated by this condition increase from 47 to 67.8%. The ion density of PVDF organic thin films fabricated by substrate temperature variation from $30^{\circ}C$ to $105^{\circ}C$ decreased from $1.62{\times}10^{16}cm^3$ to $6.75{\times}10^{11}cm^3$ when temperature and frequency were $100^{\circ}C$, 10Hz, respectively. The $d_{33}$ and piezo-voltage coefficient of PVDF organic thin films increased from 20pPC/N to 33pC/N and $162.9{\times}10^{-3}V{\cdot}m/N$ to $283.2{\times}10^{-3}V{\cdot}m/N$, respectively. For the sake of the applications of piezoelectric sensor, we analyzed the output voltage characteristic as a function of the distance between an oscillator of 28kHz and PVDF organic thin film transducer. From this, we found that the output voltage is inversely proportional to the distance. At this time, the period was about $35.798{\mu}s$ and equal the oscillator frequency.

  • PDF

Study on Static Pressure Error Model for Pressure Altitude Correction (기압 고도의 정밀도 향상을 위한 정압 오차 모델에 관한 연구)

  • Jung, Suk-Young;Ahn, Chang-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.47-56
    • /
    • 2005
  • In GPS/INS/barometer navigation system for UAV, vertical channel damping loop was introduced to suppress divergence of the vertical axis error of INS, which could be reduced to the level of accuracy of pressure altitude measured by a pitot-static tube. Because static pressure measured by the pitot-static tube depends on the speed and attitude of the vehicle, static pressure error models, based on aerodynamic data from wind tunnel test, CFD analysis, and flight test, were applied to reduce the error of pressure altitude. Through flight tests and sensitivity analyses, the error model using the ratio of differential pressure and static pressure turned out to be superior to the model using only differential pressure, especially in case of high altitude flight. Both models were proposed to compensate the effect of vehicle speed change and used differential and static pressure which could be obtained directly from the output of pressure transducer.

Ultrasonographic Resistive Index of the Cranial Pancreaticoduodenal Artery in Normal Conscious Dogs (정상견에서 전방 췌장십이장 동맥의 초음파학적 혈관 저항지수)

  • Eom, Ki-Dong;Lee, Hae-oon;Seong, Yun-sang;Lee, Jeong-min;Lee, Jong-won;Oh, Tae-ho
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.274-277
    • /
    • 2003
  • The purpose of this study was to determine the range of resistive index(RI) of the cranial pancreaticoduodenal artery(cPDA) in the normal dog's and to assess the possibility of clinical application of RI for diagnosing a pancreatitis. Five patients with acute pancreatitis and 17 healthy adult beagle dogs were used. Duplex color Doppler ultrasonographic examination was performed by using a real-time scanner with 11-MHz linear-array transducer. The dogs were restrained in dorsal recumbency without the use of chemical agent. The mean RI of the normal pancreas(0.63$\pm$0.04) was significantly(t = 5.79, p = 0.001) different from acute pancreatitis dog(0.75$\pm$0.04). Duplex color Doppler ultrasonography was an useful technique for detecting and measuring RI of the cPDA. The evaluation of RI of the cPDA may be a valuable supportive diagnostic procedure for evaluating the pancreatitis or suspected in dogs.

Development of a Multi-Layer Actuator With Piezoelectric Single Crystals for an Implantable Hearing Aid (압전 단결정 재료를 이용한 이식형 인공중이용 적층 액츄에이터 개발)

  • Lee, Sang-gu;Roh, Yong-rae;Seon, Joo-heon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.127-132
    • /
    • 2005
  • Transducers for implantable hearing aids need to be small and to have good performance in frequency responses and vibration properties. From this viewpoint, we Proposed a multi-layer actuator with the piezoelectric single crystal, PMN-PT. for the implantable hearing aid. and verified its adequacy through finite element analyses and experiments. PMN-PT multi-layer actuator samples were fabricated by stacking fourteen layers of the PMN-PT crystal. Each layer were $0.2{\cal}mm$ thick and the actuator sample was $2.8{\cal}mm$ thick in total. We evaluated the performance of the PMN-PT actuator through impedance analyses and vibration displacement measurements, and compared the result with that of a PZT actuator. Results of all the process confirmed the feasibility of the PMN-PT actuator as a good transducer for an implantable hearing aid.

Effects of Dopamine on the Contractility and Action Potential of the Rabbit Papillary Muscle (Dopamine이 토끼 유두근의 수축력과 활동전압에 미치는 영향)

  • Huh, In-Hoi;Park, Jong-Wan
    • YAKHAK HOEJI
    • /
    • v.32 no.6
    • /
    • pp.402-414
    • /
    • 1988
  • In order to clarify the receptor types and mechanisms underlying the positive inotropic effect of dopamine on the mammalian ventricular myocardium, the action potential, its first derivatives and isometric contraction of the rabbit papillary muscle were recorded using a force transducer and glass capillary microelectrodes filled with 3M KCl. The results were as follows; (1) In normal Tyrode solution, the contractile force was increased and duration of action potential was shortened with increments of dopamine concentration ($10^{-6}-10^{-4}M$). (2) The dose-response curve was markedly shifted to the right by pretreatment with reserpine (5mg/kg i.p., 24hrs prior to the experiment). (3) In 19mM $K^+-Tyrode$ solution, the duration of action potential, maximum rate of rise (V_{max}) of action potential and overshoot were significantly increased with increments of dopamine concentration ($10^{-6}-10^{-4}M$). (4) The inotropic effect of dopamine on the rabbit papillary muscle pretreated with reserpine was antagonized by atenolol ($10^{-6}M$), but not by phentolamine ($3{\times}10^{-6}M$). (5) In rabbit papillary muscle partially depolarized by 19mM $K^+-Tyrode$ solution, slow electrical response (calcium mediated action potential) as well as contraction were restored by dopamine ($10^{-4}M$); this restoration was blocked by calcium antagonists ($3{\times}10^{-5}M$ $LaCl_3{\cdot}6H_2O$, $3{\times}10^{-6}M$ diltiazem) or ${\beta}-adrenoceptor$ antagonist ($3{\times}10^{-6}M$ atenolol), but not affected by ${\alpha}-adrenoceptor$ antagonist ($10^{-5}M$ phentolamine, $3{\times}10^{-6}M$ yohimbine) or vascular dopaminergic receptor antagonist ($10^{-5}M$ haloperidol). The above results may be interpreted as that the positive inotropic effect of dopamine through both direct and indirect action are caused by increase in slow inward current ($Ca^{2+}$ influx into themyocardial cell), and the direct action is mainly due to the stimulation of ${\beta}-adrenoceptors$ in the rabbit papillary muscle.

  • PDF

A Study on the Construction of Littman and Littrow Type Tunable Diode Laser Systems (Littman 및 Littrow 타입 파장가변 반도체 레이저의 제작에 관한 연구)

  • Baek, Woon-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.273-277
    • /
    • 2006
  • In this paper, we constructed the Littman type and fixed Littrow type tunable external-cavity diode laser systems. The laser output, which is the 0th-order diffracted beam from the diffraction grating in an external cavity, was the single longitudinal mode. Its FWHM was measured as less than 9MHz. With the diode driving current of 140mA and operating temperature of $25^{\circ}C$, the coarse tuning range of 5.375nm was measured for the Littman type, and of 13.65nm was measured for the fixed Littrow type. A fine tuning experiment in which an external mirror was rotated by a PZT driven by a sawtooth wave was performed, and its tuning range of 0.042nm was measured for both types. The fixed Littrow type tunable external-cavity diode laser system was an improvement on the conventional Littrow type tunable laser system in which the output direction varies due to the grating embedded in the mirror plate.

A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

  • Abbas, Mohammad Nooredeen;Amer, Hend Samy
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1153-1159
    • /
    • 2013
  • A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from $3{\times}10^{-7}$ to $1{\times}10^{-2}$ M and a lower detection limit (LDL) of $1{\times}10^{-7}$ M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.

Effects of Lycii fructus and Astragalus membranaceus Mixed Extracts on Immunomodulators and Prevention of Diabetic Cataract and Retinopathy in Streptozotocin-induced Diabetes Rat Model (Streptozotocin으로 유발한 당뇨병성 쥐에서의 당뇨병성 백내장과 망막병증에 대한 구기자와 황기 혼합 추출물 등의 면역 조절 및 예방 효과)

  • Jeon, Yun-Hui;Moon, Jun-Woong;Kweon, Hyuk-Jung;Jeoung, Young-Jun;An, Chi-Sun;Jin, Hai-Lan;Hur, Sun-Jin;Lim, Beong-Ou
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.1
    • /
    • pp.15-21
    • /
    • 2010
  • This study was conducted to investigate the effects of Lycii fructus and Astragalus membranaceus mixed extracts on immunomodulators and prevention in a streptozotocin-induced diabetes rat model. A total of 28 male rats were divided into four dietary groups and fed a commercial diet (A), commercial diet plus induced diabetes by a streptozotocin (STZ) injection (B), induced diabetes by STZ plus medicinal crop extracts(I&$H^{(R)}$) diet (C), and medicinal crop extracts (I&$H^{(R)}$) diet (D). Immunoblotting analyses revealed cytokine expression, and ELISA analyses revealed immunoglobulin E and nitric oxide production. As a results, the tumor necrosis factor-$\alpha$ (TNF-$\alpha$) and inducible nitric oxide synthase (iNOS) as a inflammatory cytokine were decreased. Interleukin-6 (IL-6) and signal transducer and activation of transcription 3 (STAT3) cytokine related in diabetes expression through JAK/STAT3 pathway were also decreased. Furthermore, immunoglobulin E and nitric oxide production were decreased in the serum and lens, respectively. These results suggest that Lycii fructus and Astragalus membranaceus mixed extracts provide positive effects on immunomodulators and prevention in diabetes and eye disease complications.