• Title/Summary/Keyword: TOF method

Search Result 262, Processing Time 0.024 seconds

Diffusion coefficients of electrons in $SF_6$-Ar Mixtures Gas used by MCS-BEq Algorithm ($SF_6$-Ar 혼합기체(混合氣體)의 MCS-BE_q알고리즘에 의한 확산계수)

  • Kim, Sang-Nam;Ha, Sung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1150-1153
    • /
    • 2004
  • Diffusion coefficients Of electrons in $SF_6$-Ar mixtures gas used by MCS- BEq algorithm has been analysed over the E/N range $30\sim300$(Td) by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight(TOF) method, The results show that the deduced electron drift velocities, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with theoretical for a rang of E/N values The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

  • PDF

Energy Distribution Function for Electrons in $SF_6$+He mixtures gas used by MCS-BEq (MCS-BEq에 의한 $SF_6$-He 혼합기체의 에너지 분포함수)

  • Seong, Nak-Jin;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.41-44
    • /
    • 2004
  • This paper describes the electron transport characteristics in $SF_6$-He gas calculated for range of E/N values from 50${\sim}$700[Td] by the Monte Carlo simulation(MCS) and Boltzmann equation(BEq) method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters are obtained by TOF method. The results gained that the values of the electron swarm parameters such as the electron drift velocity. the electron ionization or attachment coefficients. longitudinal and transverse diffusion coefficients agree with the experimental and theoretical for a range of E/N.

  • PDF

Electron Energy Distribution Function in SF6-He Gas by Simulation (시뮬레이션에 의한 SF6-He 혼합기체에서 전자에너지 분포함수)

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.19-23
    • /
    • 2014
  • This paper describes the electron transport characteristics in $SF_6$-He gas calculated E/N values 0.1~700[Td] by the Monte Carlo simulation and Boltzmann equation method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters obtained by TOF method. This study gained the values of the electron swarm parameters such as the electron drift velocity, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients for $SF_6$-He gas at a range of E/N. A set of electron collision cross section has been assembled and used in Monte Carlo simulation to predict values of swarm parameters. The result of Boltzmann equation and Monte Carlo Simulation has been compared with experimental data by Ohmori, Lucas and Carter. The swarm parameter from the swarm study are expected to sever as a critical test of current theories of low energy scattering by atoms and molecules.

Analysis of electron transport properties in $SF_6$+He mixture gas used by MCS-BE (MCS-BE에 의한 $SF_6$+He 혼합기체의 전자수송특성 해석)

  • 하설철;송병두;유회영;김상남;백승권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.359-364
    • /
    • 2000
  • The paper describes the electron transport characteristics in SP$_{6}$+He gas calculated E/N values 0.1~700[Td] by the Monte Carlos simulation and Boltzmann equation method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters obtained by TOF method. This study gained the values of the electron swarm parameters such as the electron drift velocity the electron ionization or attachment coefficients longitudinal and transverse diffusion coefficients for SF$_{6}$+He gas at a range of E/N.E/N.

  • PDF

Outcome of neonatal palliative procedure for pulmonary atresia with ventricular septal defect or tetralogy of Fallot with severe pulmonary stenosis: experience in a single tertiary center

  • Jo, Tae Kyoung;Suh, Hyo Rim;Choi, Bo Geum;Kwon, Jung Eun;Jung, Hanna;Lee, Young Ok;Cho, Joon Yong;Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.7
    • /
    • pp.210-216
    • /
    • 2018
  • Purpose: The present study aimed to evaluate progression and prognosis according to the palliation method used in neonates and early infants aged 3 months or younger who were diagnosed with pulmonary atresia with ventricular septal defect (PA VSD) or tetralogy of Fallot (TOF) with severe pulmonary stenosis (PS) in a single tertiary hospital over a period of 12 years. Methods: Twenty with PA VSD and 9 with TOF and severe PS needed initial palliation. Reintervention after initial palliation, complete repair, and progress were reviewed retrospectively. Results: Among 29 patients, 14 patients underwent right ventricle to pulmonary artery (RV-PA) connection, 11 palliative BT shunt, 2 central shunt, and 2 ductal stent insertion. Median age at the initial palliation was 13 days (1-98 days). Additional procedure for pulmonary blood flow was required in 5 patients; 4 additional BT shunt operations and 1 RV-PA connection. There were 2 early deaths among patients with RV-PA connection, one from RV failure and the other from severe infection. Finally, 25 patients (86%) had a complete repair. Median age of total correction was 12 months (range, 2-31 months). At last follow-up, 2 patients had required reintervention after total correction; 1 conduit replacement and 1 right ventricular outflow tract (RVOT) patch enlargements. Conclusion: For initial palliation of patients with PA VSD or TOF with severe PS, not only shunt operation but also RV-PA connection approach can provide an acceptable outcome. To select the most proper surgical strategy, we recommend thorough evaluation of cardiac anomalies such as RVOT and PA morphologies and consideration of the patient's condition.

Importance of pulmonary valve morphology for pulmonary valve preservation in tetralogy of Fallot surgery: comparison of the echocardiographic parameters

  • Choi, Su Jin;Kwon, Jung Eun;Roh, Da Eun;Hyun, Myung Chul;Jung, Han Na;Lee, Young Ok;Cho, Joon Yong;Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.5
    • /
    • pp.189-194
    • /
    • 2020
  • Background: The decision to use transannular patching (TAP) during tetralogy of Fallot (TOF) repair depends on the pulmonary valve annulus size; the z score of the pulmonary annulus is the most commonly used predictor. However, definitive results are not obtained with z scores as different z score data sets are used for different parameters. Purpose: This study aimed to identify the echocardiographic and other key factors that warranted a change in the surgical method during TOF surgery. Methods: Sixty-two patients were enrolled and divided into a pulmonary valve (PV) preservation group and a TAP group. Their medical records were reviewed. Results: The z score for PV annulus (PVA), ratio of the PVA to aortic annulus size, and ratio of PVA to descending aorta (DAO) size were significantly different between the PV preservation and TAP groups (-1.72±1.52 vs. -3.07±1.94, P=0.004; 0.62±0.12 vs. 0.50±0.14, P=0.002; and 1.32±0.32 vs. 1.07±0.36, P=0.008, respectively). For TAP repair, the PVA z score had a sensitivity of 65.4% and specificity of 73.1%, ratio of PVA to aortic annulus size had a sensitivity of 73.1% and specificity of 65.4%, and ratio of PVA to DAO size had a sensitivity of 69.2% and specificity of 57.7%. The TAP group showed more monocuspid PVs (P=0.011), while the PV preservation group showed more tricuspid PVs (P=0.027). Commissurotomy was more frequently performed in the PV preservation group than in the TAP group (P=0.001). Of patients with commissurotomy, 58% showed a PV z score<-2. Conclusion: Although various echocardiographic parameters may serve as predictors for determining surgical methods for TOF patients, the PV morphology and tissue characteristics should also be considered.

Evaluation of Conotruncal Anomalies by Electron Beam Tomography (Conotruncal 기형 평가에서 전자선 단층 촬영 (EBT)의 정확성)

  • 최병욱;박영환;최병인;최재영;김민정;유석종;이종균;설준희;이승규
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.290-300
    • /
    • 2000
  • Background: To evaluate the diagnostic accuracy of EBT(Electron Beam Tomography) in the diagnosis of conotruncal anomaly and to determine whether it can be used as a substitute for cardiac angiography. Material and Method: 20 patients(11M & 9F) with TOF(n=7, pulmonary atresia 2), DORV(n=7), complete TGV(n=4), & corrected TGV(n=2) were included. The age ranged from 7 days to 26 years(median 60 days). We analyzed the sequential chamber localization, the main surgical concenrn in each disease category (PA size, LVED volume and coronary artery pattern for TOF & pulmonary atresia, the LV mass, LVOT obstruction, coronary artery pattern for complete TGV, and type of VSD and TV-PV distance for DORV, etc) and other associated anomalies(e.g., VSD, arch anomalies, tracheal stenosis, etc). Those were compared with the results of echocardiography(n=19), angiography (n=9), and surgery(n=11). The interval between EBT and echocardiography/angiography was within 20/11 days, respectively except for an angiography in a patient with corrected TGV (48 days). Result: EBT correctly diagnosed the basic components of conotruncal anomalies in all subjects, compared to echocardiography, angiography or surgery. These included the presence, type and size of VSD(n=20), pulmonic/LV outflow tract stenosis(n=15/2), relation of great arteries and the pattern of the proximal epicardial coronary arteries(16 out of 20). EBT proved to be accurate in quantitation of the intrapericardial and hilar pulmonary arterial dimension and showed high correlation and no difference compared with echocardiography, angiography, or surgery(p>0.05) except for left pulmonary arterial & ascending arterial dimension by echocardiography. LVED volume in seven TOF(no difference: p>0.05 & high correlation: r=0.996 with echocardiography), and LV mass in 4 complete TGV were obtained. Additionally, EBT enabled the cdiagnosis of subjlottic tracheal stenosis and tracheal bronchus in 1 respectively. Some peripheral PA stenosis were not detected by echocardiography, while echocardiography appeared to be slightly more accurate than EBT in detecing ASD or PDA. Conclusion: EBT can be a non-invasive and accurate modality of for the evaluation of most anatomical alteration including peripheral PS or interruption in patients with conotruncal anomalies. Combined with echocardiography, EBT study provides sufficient information for the palliative or total repair of anomalies.

  • PDF

The Role of Postoperative Magnetic Resonance Imaging of Microvascular Decompression of the Facial Nerve in Patients with Hemifacial Spasm (반측성 안면경련증 환자에서 안면신경의 미세혈관감압술 후에 시행한 자기공명영상의 역할)

  • Han, In Bo;Chang, Jong Hee;Chang, Jin Woo;Park, Yong Gou;Kim, Dong Ik;Chung, Sang Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.44-50
    • /
    • 2001
  • Objectives : The objective of this study was to investigate the role of postoperative three dimensional short-range magnetic resonance angiography(3D-TOF MRA) in predicting the clinical outcomes following microvascular decompression(MVD) for the treatment of a hemifacial spasm(HFS). Material and Method : Postoperative magnetic resonance(MR) imaging was performed on 123 patients with a HFS between March 1999 and May 2000. All patients who had postoperative MR imaging were undertaken preoperative MR imaging. Of the 123 patients, 122 patients were included in this retrospective study. The degree of the detachment of vascular contact, and change of the position of offender were determined by pre- and postoperative 3D-TOF MRA. These findings were compared with the surgical findings and clinical outcomes. Results : Of 122 patients who had successful MVD, clear decompression of offenders of the root entry zone(REZ) of facial nerve was found in 106 patients(86.9%), partial decompression in 10 patients(8.2%) and contact of offenders to the REZ of facial nerve in 6 patients(4.9%) by the postoperative 3D-TOF MRA. Our patients demonstrated that the types of offender did not influence with the degree of decompression of REZ of facial nerve and with surgical outcomes(p>0.05). Also, there was no significant relationship between the degree of decompression of the REZ of facial nerve from offenders and an improvement of symptoms(p>0.05). Futhermore, there was no significant relationship between the degree of decompression of the REZ of facial nerve from offenders and an improvement time (p>0.05). Conclusion : Our data suggests that MVD of facial nerve alone may not be sufficient to resolve the symptoms in all patients with hemifacial spasm. Therefore, another unknown factors besides vascular compression may be involved to cause symptoms in certain patients and it may be necessary to remove these factors with MVD simultaneously to obtain the resolution of symptom.

  • PDF

Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot

  • YaFeng Peng;XinYu Su;LiWei Hu;Qian Wang;RongZhen Ouyang;AiMin Sun;Chen Guo;XiaoFen Yao;Yong Zhang;LiJia Wang;YuMin Zhong
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1525-1536
    • /
    • 2021
  • Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF). Materials and Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index. Acquisition time and image quality were recorded and compared among the three imaging sequences. Results: 3D b-SSFP with denoising vs. 2D b-SSFP had high correlation coefficients for EDV, ESV, SV, and EF of the left (0.959-0.991; p < 0.001) as well as right (0.755-0.965; p < 0.001) ventricular metrics. The image acquisition time ± standard deviation (SD) was 25.1 ± 2.4 seconds for 3D b-SSFP compared with 277.6 ± 0.7 seconds for 2D b-SSFP, indicating a significantly shorter time with the 3D than the 2D sequence (p < 0.001). Image quality score was better with 3D b-SSFP combined with denoising than with 3D b-SSFP (mean ± SD, 3.8 ± 0.6 vs. 3.5 ± 0.6; p = 0.005). Signal-to-noise ratios for blood and myocardium as well as contrast between blood and myocardium were higher for 3D b-SSFP combined with denoising than for 3D b-SSFP (p < 0.05 for all but septal myocardium). Conclusion: The 3D b-SSFP sequence can significantly reduce acquisition time compared to the 2D b-SSFP sequence for cine imaging in the evaluation of ventricular function in children with rTOF, and its quality can be further improved by combining it with an NLM denoising method.

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.