• Title/Summary/Keyword: TOF MRA

Search Result 37, Processing Time 0.029 seconds

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique- (뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 -)

  • Choi, Sung-Hyun;Goo, Eun-Hoe;Hwang, Sun-Kwang;Lee, Gang-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

Associations between Morphological Characteristics of Intracranial Arteries and Atherosclerosis Risk Factors in Subjects with Less Than 50% Intracranial Arterial Stenosis

  • Byun, Hokyun;Jang, Jinhee;Choi, Hyun Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.150-157
    • /
    • 2018
  • Purpose: To assess associations between morphological characteristics of intracranial arteries in time-of-flight MR angiography (TOF-MRA) and atherosclerotic risk factors. Materials and Methods: From January 2014 to October 2015, a total of 129 patients (65 men and 64 women) without intracranial arterial stenosis > 50% were included in this study. All MRIs were performed using a 3T machine with 3D TOF-MRA sequences. We evaluated irregularity, tortuosity, and dilatation of intracranial arteries in maximal intensity projection (MIP) of TOF-MRA. Subjects' risk factors for atherosclerosis including history of hypertension and diabetes were collected by reviewing their medical records. Associations between morphological characteristics and each known atherosclerosis risk factor were examined using univariate regression analysis. Multivariate regression models were built to determine combined association between those risk factors and morphologic changes of intracranial arteries. Results: In multivariate analysis, hypertension (coefficient [95% CI]: 0.162 [0.036, 0.289], P = 0.012) and absence of diabetes (coefficient [95% CI]: -0.159 [-0.296, -0.023], P = 0.022) were associated with large diameter of intracranial arteries. Males (coefficient [95% CI]: 0.11 [-0.006, 0.23], P = 0.062) and higher age (coefficient [95% CI]: 0.003 [-0.001, 0.008], P = 0.138) had marginal association with increased diameter. Tortuosity was associated with old age (OR: 1.04 [1.02, 1.07], P < 0.001). Irregular contour of intracranial arteries was significantly associated with old age (OR: 1.05 [1.02, 1.09], P = 0.004), presence of diabetes (OR: 2.88 [1.36, 6.15], P = 0.0058), and previous ischemic stroke (OR: 3.91 [1.41, 11.16], P = 0.0092). Conclusion: Morphological characteristics (irregularity, tortuosity, dilatation) of intracranial arteries seen in TOF-MRA might be associated with atherosclerotic risk factors in subjects with no or mild stenosis.

Dilatation of Superior Ophthalmic Vein and Visual Disturbance by Central Venous Stenosis: A Case Mimicking Cavernous Sinus Dural Arteriovenous Fistula (상안정맥 확장 및 시력 저하를 보인 중심정맥협착: 해면경막 동정맥루로 오인된 증례 보고)

  • Young Hun Jeon;Kyung Sik Yi;Chi Hoon Choi;Yook Kim;Yeong Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1619-1627
    • /
    • 2021
  • Central venous stenosis is a relatively common complication in hemodialysis patients; however, jugular venous reflux (JVR) and increased intracranial pressure are rare, and associated progressive visual disturbance was reported in only a few cases. Here, we report a case of JVR with visual disturbance and increased intracranial pressure. Notably, the MRI was accompanied by a dilatation of the superior ophthalmic vein, which was mistaken for a cavernous sinus dural arteriovenous fistula (CSdAVF). The patient had JVR on time-of-flight MR angiography (TOF-MRA) and severe stenosis of the left brachiocephalic vein on conventional angiography. After balloon angioplasty for central venous stenosis, he was discharged after improvement of his visual disturbance. Although JVR due to central venous stenosis and CSdAVF might show similar symptoms, treatment plans are different. Therefore, it is important to distinguish radiologically based on a thorough review of MRI and TOF-MRA and confirm the central venous stenosis on cerebral angiography for the accurate diagnosis.

Contrast-Enhanced MR Angiography of Supra-Aortic Arteries: Review of Current Techniques, Diagnostic Accuracy and Common Pitfalls in Steno-Occlusive Diseases

  • Lee, Jeong-Hyun;Kim, Jin-Hyoung;Kim, Hyun-Jeong;Park, Choong-Gon;Lee, Deok-Hee;Lee, Ho-Kyu;Kim, ang-Joon;Suh, Dae-Chul
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.97-97
    • /
    • 2003
  • Contrast-enhanced MR angiography (CE-MRA) gradually occupies its position as a primary evaluation tool forsteno-occlusive disease of supra-aortic cervical arteries. It has several advantages over time-of-flight (TOF) technique such as shorter imaging time, less saturation effect, and less flow- and motion-related artifacts. Diverse methods of k-space sampling, imaging sequences, and strategies for image acquisitiontiming have been introduced since its early clinical application. Especially, methods of k-space sampling and image acquisition timing are very important to achieve maximal arterial enhancement and suppress venous signal while maintaining large scan coverage and high spatial resolution. In addition, regardless of several advantages over TOF technique, it still has a tendency to overestimate the degree of stenosis in patients with carotid or vertebralartery disease. In this exhibit, we will overview the current techniques of CE-MRA with special attention to methods of k-space sampling and image acquisition timing. We will also discuss diagnostic accuracy of CE-MRA in patients with supra-aortic cervical artery stenosis and artifacts frequently misinterpreted as steno-occlusive lesion on CE-MRA.

  • PDF

An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

  • Yoo, Yeong-Jun;Choi, Sung-Hyun;Dong, Kyung-Rae;Ji, Yun-Sang;Choi, Ji-Won;Ryu, Jae-Kwang
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.325-332
    • /
    • 2018
  • Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, "very bad"; 2 points, "bad"; 3 points, "average"; 4 points, "good"; and 5 points, "very good" - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA(92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.

The Role of Postoperative Magnetic Resonance Imaging of Microvascular Decompression of the Facial Nerve in Patients with Hemifacial Spasm (반측성 안면경련증 환자에서 안면신경의 미세혈관감압술 후에 시행한 자기공명영상의 역할)

  • Han, In Bo;Chang, Jong Hee;Chang, Jin Woo;Park, Yong Gou;Kim, Dong Ik;Chung, Sang Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.44-50
    • /
    • 2001
  • Objectives : The objective of this study was to investigate the role of postoperative three dimensional short-range magnetic resonance angiography(3D-TOF MRA) in predicting the clinical outcomes following microvascular decompression(MVD) for the treatment of a hemifacial spasm(HFS). Material and Method : Postoperative magnetic resonance(MR) imaging was performed on 123 patients with a HFS between March 1999 and May 2000. All patients who had postoperative MR imaging were undertaken preoperative MR imaging. Of the 123 patients, 122 patients were included in this retrospective study. The degree of the detachment of vascular contact, and change of the position of offender were determined by pre- and postoperative 3D-TOF MRA. These findings were compared with the surgical findings and clinical outcomes. Results : Of 122 patients who had successful MVD, clear decompression of offenders of the root entry zone(REZ) of facial nerve was found in 106 patients(86.9%), partial decompression in 10 patients(8.2%) and contact of offenders to the REZ of facial nerve in 6 patients(4.9%) by the postoperative 3D-TOF MRA. Our patients demonstrated that the types of offender did not influence with the degree of decompression of REZ of facial nerve and with surgical outcomes(p>0.05). Also, there was no significant relationship between the degree of decompression of the REZ of facial nerve from offenders and an improvement of symptoms(p>0.05). Futhermore, there was no significant relationship between the degree of decompression of the REZ of facial nerve from offenders and an improvement time (p>0.05). Conclusion : Our data suggests that MVD of facial nerve alone may not be sufficient to resolve the symptoms in all patients with hemifacial spasm. Therefore, another unknown factors besides vascular compression may be involved to cause symptoms in certain patients and it may be necessary to remove these factors with MVD simultaneously to obtain the resolution of symptom.

  • PDF