• Title/Summary/Keyword: TN System

Search Result 429, Processing Time 0.022 seconds

Change Pattern Analysis of the COD and Nutrient Concentration in Jumunjin Harbour, Gangneung (강릉 주문진항 COD 및 영양염류의 농도변화 양상 분석)

  • Cho Hong-Yean;Kim Chang-Il;Lee Dal-Soo;Han Dong-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.211-224
    • /
    • 2006
  • It was analysed that spatial and temporal change patterns of COD, TN and TP were measured monthly from 2002 to 2005 in Jumunjin Harbour. Cenerally, concentration of upper layer higher than lower layer, concentration difference of COD, TN and TP on upper lower layer at inner zone in Jumunjin Harbour higher than sea area front of breakwater. Seasonal change width of COD concentration different, but seasonal change pattern of COD, $NH_{4}-N$ and TN clearly showed. Water quality improvement effect of seawater exchange facilities and sewage treatment plants is analysed quantitatively using averaged spatial and temporal data set. Change of COD small at 2003, concentration reduced about $34{\sim}47%$ at all zones on 2004 and 2005. TN was influenced largely effect of seawater exchange facilities. Concentration reduction at zone 1, 2, 3 estimated about $60{\sim}70%,\;40{\sim}60%,\;40%$, respectively. As a consequence, concentration reduction of COD and TN that is, effect of water quality improvement influenced seawater exchange facilities appeared not only at inner zone, also sea area front of breakwater and entrance of Jumunjin Harbour.

Estimation of Pollutants Residence Time During the Flood and Dry Season in Gwangyang Bay (광양만의 홍수기 및 갈수기의 오염물질 체류시간 산정)

  • Lee, In-Cheol;Kim, Jin-Hyuk;Kong, Hwa-Hun
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.20-26
    • /
    • 2008
  • In this paper, in order to set up the management system of water quality environment in Gwangyang Bay, the cluster analysis of water quality environment, the estimation of inflowing pollutant loads and residence time of pollutants in this bay was carried out. The Gwangyang Bay was divided into eight sea areas by cluster analysis and spatio-temporal change of water quality. The river discharges in the Bay were calculated about $11,681{\times}103m^3/day$ from the numerical simulation by Tank model. In addition, inflowing pollutant loads of COD, SS, TN, TP, DIN and DIP in Gwangyang Bay were estimated at 398 ton-COD/day, 2,846 ton-SS/day, 195 ton-TN/day, 5 ton-TP/day, 126 ton-DIN/day and 3 ton-DIP/day, respectively. Moreover, residence times of COD, TN and TP in the Bay was estimated at 6 days-COD, 20 days-TN and 195 days-TP, respectively in the dry season, and 3 days-COD, 6 days-TN and 21 days- TP, respectively, in the flood season. The central part of Gwangyang Bay (Region IV) has the longest residence time of overall pollutants.

The Estimation of Craniovertebral Angle using Wearable Sensor for Monitoring of Neck Posture in Real-Time (실시간 목 자세 모니터링을 위한 웨어러블 센서를 이용한 두개척추각 추정)

  • Lee, Jaehyun;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.278-283
    • /
    • 2018
  • Nowdays, many people suffer from the neck pain due to forward head posture(FHP) and text neck(TN). To assess the severity of the FHP and TN the craniovertebral angle(CVA) is used in clinincs. However, it is difficult to monitor the neck posture using the CVA in daily life. We propose a new method using the cervical flexion angle(CFA) obtained from a wearable sensor to monitor neck posture in daily life. 15 participants were requested to pose FHP and TN. The CFA from the wearable sensor was compared with the CVA observed from a 3D motion camera system to analyze their correlation. The determination coefficients between CFA and CVA were 0.80 in TN and 0.57 in FHP, and 0.69 in TN and FHP. From the monitoring the neck posture while using laptop computer for 20 minutes, this wearable sensor can estimate the CVA with the mean squared error of 2.1 degree.

Treatment of Seafood Wastewater Using AO$_2$ System with PU-AC Media (담체가 첨가된 AO$_2$공법을 이용한 수산물 가공폐수의 처리)

  • Lee, Soon;Park, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.666-672
    • /
    • 2008
  • Feasibility of simultaneous removal of organic matter, nitrogen and phosphorus was evaluated by applying AO$_2$ system to treat wastewater from a seafood processing plant. Treatability test was conducted by incorporating activated sludge from municipal sewage treatment plant with PU-AC media. Inflow concentrations of COD, TN, and TP were 198$\sim$1,240 mg/L, 75$\sim$577.4 mg/L, and 2.2$\sim$53.5 mg/L, respectively. Average removal efficiencies and outflow concentration of COD, TN, and TP were 86.5%, 65.7 mg/L; 81.4%, 53.1 mg/L; and 80.6% 4.07 mg/L, respectively. Stable operation was possible by increasing organic matter, nitrogen, and phosphorus loading rate to seafood wastewater treatment system composed of anaerobic and aerobic reactors. Used PU-AC media was proved to be biodegradable in this AO$_2$ system by maintaining high biomass concentration in the PU-AC media.

Removal of Nutrients from Stream Water Polluted with Nonpoint Source Pollution by Cultivation of Phytoplankton. (비점오염원으로부터 오염된 하천수에서 식물플랑크톤 배양을 이용한 영양염류 제거)

  • Cho, Ahn-Na;Jung, Da-Woon;Jung, You-Jung;Choi, Seung-Ik;Ahn, Tae-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A phytoplankton cultivation system was installed and operated for removal of nutrients from stream water polluted by nonpoint source pollution. The system was a continuous-flow culture comprising a phytoplankton tank that received inflow from a storage reservoir. When the system was operated as a batch culture for the purpose of determining hydraulic retention time (HRT), the proper HRT value was three days, and the removal rate of TP and TN averaged 70% and 44%, respectively. When the system was operated with the continuous flow from a stream for 45 days, 53.9% of TP and 53.1% of TN were removed as sludge. Due to active growth of phytoplankton, pH and dissolved oxygen in the phytoplankton tank were extremely high, reaching 10.8 and 16mg $L^{-1}$, respectively. It was concluded that nutrients can be effectively removed from polluted stream waters by cultivating phytoplankton.

Comparison of Nitrogen Removal During Plant Growing Season with Non-Growing One in Free Water Surface Wetlands Purifying Stream Water (하천수를 정화하는 자유수면습지의 식물 성장기와 비성장기의 질소제거 비교)

  • Yang, Hong-Mo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.82-92
    • /
    • 2010
  • Removal rates of NO3-N and TN in a free water surface wetland system during emergent plant growing season and non-growing were investigated. The system was established on floodplain in the down reach of the Gwangju Stream in 2008. Its dimensions were 46 meters in length and 5 meters in width. Typha angustifloria L. growing in pots about two years were planted on the half area of the system and Zizania latifolia Turcz on the other half. Water of the stream was funneled into it by gravity flow and its effluent was discharged back into it. Volumes and water quality of inflow and outflow were analyzed from October 2008 to September 2009. Inflow into the system averaged approximately 715 $m^3$/day and hydraulic residence time was about 1.5 hr. Average influent and effluent $NO_3$-N concentration was 3.37 and 2.74 mg/L, respectively and $NO_3$-N retention amounted to 18.7%. Influent and effluent TN concentration averaged 4.67 and 3.69 mg/L, respectively and TN abatement reached to 20.9%. $NO_3$-N removal rate (%) during plant growing season ($22.67{\pm}3.70$, mean ${\pm}$ standard error) was significantly high (p<0.001) when compared with that during plant non-growing one ($15.02{\pm}3.23$). TN abatement rate (%) during plant growing season ($27.42{\pm}5.98$) was also significantly high (p<0.001) when compared with that during plant non-growing one ($13.66{\pm}3.08$).

The Development of the Analysis Program for the Electric Shock Accidents Occurred in the TN and TT System (TN 및 TT 계통에서의 감전사고 분석 프로그램 개발)

  • Lee, Seok-Won;Ryu, Bo-Hyuk;Kim, Hyung-Seok;Jung, Won-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • According to the statistics from the Ministry of labor, 70~80 people died by work-related electric shock accidents in the workplace and this number is about 10~20 times higher than those of the foreign countries such as Japan and the United Kingdom in frequencies and rates per 100,000. The electrocution deaths had decreased from several hundred in 1990s to 67 in 2002, since then there has been little change over the last 5 years. To reduce this number of the electrocution death, it is necessary to analyze the sources of the accidents and to implement the suitable measures for preventing the similar accidents from occurring. But there is not any consensus standard method or procedures for accident investigation yet. And the results solely depend on the ability of the investigator. Because of the demand of eliminating technical barrier for free trading, the IEC 60364 is adopted as a regulation for low voltage electrical installations in Korea. The facilities designed and constructed by IEC 60364 are increasing. The facilities by IEC 60364 have different features in comparison with the facilities by Korea eletro technical regulation, and these features combined with parameters of electric shock accident can greatly affect the consequences of the electric accidents. The accident analysis program for electric shock injuries in Terra Neutral(TN) and Terra Terra(TT) system was developed in this paper, which was based on KOSHA Electric Shock Analysis Program(ESAP).

An Experimental Study on the Pond Sediment and Water Quality Purification using Oxygen Solubilization Device(OSD) System (산소용해수를 이용한 호소 저질 및 수질개선에 관한 실험적 연구)

  • Kim, Young-Taek;Bae, Yoon-Sun;Roh, Eun-Kyung;Park, Chul-Hwi;Lee, Yeon-Ku
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.94-103
    • /
    • 2006
  • The pollution in closing water can be caused by not only artificial factor like sewage but also natural factor like elution from sediment. In this study we analyzed Sediment Oxygen Demand (SOD) for verification of sediment purification effect and sediment elution experiment as well as general items like COD, TN, TP, SS to complement and assess the effect of sediment and water quality. The experiment result showed that the release rate of OSD system were 4 times and 3 times as large as control for P and Fe respectively. SOD for operated OSD system and control were $12.18gO_2{\cdot}m^{-2}{\cdot}d^{-1}$ and $47.95gO_2{\cdot}m^{-2}{\cdot}d^{-1}$. From water qualities analyzed by COD, TN, TP, SS, chlorophyll-a, the removal efficiency increase of TN, TP, chlorophyll-a and COD were about 10~20%, 40~50% and 10% respectively. In conclusion, OSD can contribute to improvement of both the waterbody and the sediment environment effectively.

Anaerobic Treatment of Food Waste Leachate for Biogas Production Using a Novel Digestion System

  • Lim, Bong-Su;Kim, Byung-Chul;Chung, In
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.41-46
    • /
    • 2012
  • In this study, the performance of new digestion system (NDS) for the treatment of food waste leachate was evaluated. The food waste leachate was fed intermittently to an anaerobic reactor at increasing steps of 3.3 L/day (hydraulic retention time [HRT] = 30 day), 5 L/day (HRT = 20 day), and finally 10 L/day (HRT = 10 day). In the anaerobic reactor, the pH and alkalinity were maintained at 7.6 to 8.2 and 8,940-14,400 mg/L, respectively. Maximum methane yield determined to be 0.686L $CH_4$/g volatile solids (VS) containing HRT over 20 day. In the digester, 102,328 mg chemical oxygen demand (COD)/L was removed to produce 350 L/day (70% of the total) of biogas, but in the digested sludge reduction (DSR) unit, only 3,471 mg COD/L was removed with a biogas production of 158 L/day. Without adding any chemicals, 25% of total nitrogen (TN) and 31% of total phosphorus (TP) were removed after the DSR, while only 48% of TN and 32% of TP were removed in the nitrogen, phosphorus, and heavy metals (NPHM) removal unit. Total removal of TN was 73% and total removal of TP was 63%.

Transmit-Nulling SDMA for Coexistence with Fixed Wireless Service

  • Jo, Han-Shin;Mun, Cheol
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.1
    • /
    • pp.34-41
    • /
    • 2011
  • This paper proposes a systematic design for a precoding codebook for a transmit-ing space-division multiple access (TN-SDMA) sharing spectrum with existing fixed wireless service (FWS). Based on an estimated direction angle of a victim FWS system, an interfering transmitter adaptively constructs a codebook, forming a transmit in the direction angle, while satisfying orthogonal beamforming constraints. Sum throughput results indicate that the throughput loss of TN-SDMA relative to a practical SDMA, called per user unitary and rate control ($PU^2RC$), is lower at larger number of transmission antennas, lower signal-to-noise ratio, or a smaller number of users. In particular, a small loss (12% throughput loss) is provided for practical system parameters. Spectrum sharing results confirm that TNSDMA efficiently shares spectrum with FWS systems by reducing protection distance to more than 66 %. Although a TN-SDMA system always has lower throughput compared to $PU^2RC$ in non-coexistence scenarios; it offers an intriguing opportunity to re-use a spectrum already allocated to an FWS.