• Title/Summary/Keyword: TMS(Transcranial Magnetic Stimulation)

Search Result 58, Processing Time 0.022 seconds

A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects (동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가)

  • Kim, Jae-Chang;Kyeong, Sunghyon;Lee, Jong Doo;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.169-180
    • /
    • 2013
  • Purpose : The purpose of this study was to setup a concuurent transcranial magnetic stimulation (TMS)-functional MRI (fMRI) system for understanding causality of the functional brain network. Materials and Methods: We manufactured a TMS coil holder using nonmagnetic polyether ether ketone (PEEK). We simulated magnetic field distributions in the MR scanner according to TMS coil positions and angles. To minimize image distortions caused by TMS application, we controlled fMRI acquisition and TMS sequences to trigger TMS during inter-volume intervals. Results: Simulation showed that the magnetic field below the center of the coil was dramatically decreased with distance. Through the MR phantom study, we confirmed that TMS application around inter-volume acquisition time = 100 miliseconds reduced imaging distortion. Finally, the applicability of the concurrent TMS-fMRI was tested in preliminary studies with a healthy subject conducting a motor task within TMS-fMRI and passive motor movement induced by TMS in fMRI. Conclusion: In this study, we confirmed that the developed system allows use of TMS inside an fMRI system, which would contribute to the research of brain activation changes and causality in brain connectivity.

Analysis and Design of Whole-Head Magnetic Brain Stimulators: A Simulation Study

  • Lee, Chany;Im, Chang-Hwan;Jung, Hyun-Kyo
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.3
    • /
    • pp.337-342
    • /
    • 2007
  • This paper proposes a helmet-type whole-head brain stimulator system considering a realistic head geometry. For more accurate design and computer simulations, a realistic volume conductor model was adopted and the current evoked on human cerebral cortex was analyzed using the boundary element method (BEM). To obtain a more focalized evoked current around the target points, various coil configurations were tested and an average targeting error of about 10 mm was obtained.

Non-invasive Brain Stimulation and its Legal Regulation - Devices using Techniques of TMS and tDCS - (비침습적 뇌자극기술과 법적 규제 - TMS와 tDCS기술을 이용한 기기를 중심으로 -)

  • Choi, Min-Young
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.209-244
    • /
    • 2020
  • TMS and tDCS are non-invasive devices that treat the diseases of patients or individual users, and manage or improve their health by applying stimulation to a brain through magnetism and electricity. The effect and safety of these devices have proved to be valid in several diseases, but research in this area is still much going on. Despite increasing cases of their application, legislations directly regulating TMS and tDCS are hard to find. Legal regulation regarding TMS and tDCS in the United States, Germany and Japan reveals that while TMS has been approved as a medical device with a moderate risk, tDCS has not yet earned approval as a medical device. However, the recent FDA guidance, European MDR changes, recalls in the US, and relevant legal provisions of Germany and Japan, as well as recommendations from expert groups all show signs of tDCS growing closer to getting approved as a medical device. Of course, safety and efficacy of tDCS can still be regulated as a general product instead of as a medical device. Considering multiple potential impacts on a human brain, however, the need for independent regulation is urgent. South Korea also lacks legal provisions explicitly regulating TMS and tDCS, but they fall into the category of the grade 3 medical devices according to the notifications of the Korean Ministry of Food and Drug Safety. And safety and efficacy of TMS are to be evaluated in compliance with the US FDA guidance. But no specific guidelines exist for tDCS yet. Given that tDCS devices are used in some hospitals in reality, and also at home by individual buyers, such a regulatory gap must quickly be addressed. In a longer term, legal system needs to be in place capable of independently regulating non-invasive brain stimulating devices.

Effects of electromagnetic stimulation on neurogenesis and neuronal proliferation in rat hippocampal slice culture (실험 쥐 해마조직배양에서 전자기 자극이 신경조직발생 및 증식에 미치는 영향)

  • Kim, Deok-Soo;Choi, Eung Sang;Chae, Soo Ahn
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.5
    • /
    • pp.558-564
    • /
    • 2006
  • Purpose : Transcranial electromagnetic stimulation(TMS) is a noninvasive method which stimulates the central nervous system through pulsed magnetic fields without direct effect on the neurons. Although the neurobiologic mechanisms of magnetic stimulation are unknown, the effects on the brain are variable according to the diverse stimulation protocols. This study aims to observe the effect of the magnetic stimulation with two different stimulation methods on the cultured hippocampal slices. Methods : We obtained brains from 8-days-old Spague-Dawley rats and dissected the hippocampal tissue under the microscope. Then we chopped the tissue into 450 µm thickness slices and cultured the hippocampal tissue by Stoppini's method. We divided the inserts, which contained five healthy cultured hippocampal slices respectively, into magnetic stimulation groups and a control group. To compare the different effects according to the frequency of magnetic stimulation, stimulation was done every three days from five days in vitro at 0.67 Hz in the low stimulation group and at 50 Hz in the high stimulation group. After N-methyl-D-aspartate exposure to the hippocampal slices at 14 days in vitro, magnetic stimulation was done every three days in one and was not done in another group. To evaluate the neuronal activity after magnetic stimulation, the $NeuN/{\beta}$-actin ratio was calculated after western blotting in each group. Results : The expression of NeuN in the magnetic stimulation group was stronger than that of the control group, especially in the high frequency stimulation group. After N-methyl-D-aspartate exposure to hippocampal slices, the expression of NeuN in the magnetic stimulation group was similar to that of the control group, whereas the expression in the magnetic non-stimulation group was lower than that of the control group. Conclusion : We suggest that magnetic stimulation increases the neuronal activity in cultured hippocamal slices, in proportion to the stimulating frequency, and has a neuroprotective effect on neuronal damage.

Lower Motor Neuron Hyperexcitability in Amyotrophic Lateral sclerosis: Analysis Using Motor Evoked Potentials (근위축성 측삭 경화증의 하 운동 신경원 과흥분성: 운동유발전위를 이용한 분석)

  • Bae, Jong-Seok;Hong, Suk-Chan;Kim, Min-ky;Kim, Byoung-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2003
  • Background & Objectives: Hyperexcitablity of motor system is a well-established characteristic pathophysiologic finding of amyotrophic lateral sclerosis (ALS). Whereas little is known about the source of excitability according to the progression of the disease. We evaluated the excitability and its source in advanced ALS patients using transcranial magnetic stimulation (TMS). Meterial & Methods: Motor evoked potentials (MEP) by TMS were recorded for abductor pollicis brevis muscles in 20 patients, 11 men and 9 women, with ALS. Mean age was $54.2{\pm}12.1years$, and mean disease duration was $13.9{\pm}13.4years$. Serial magnetic stimulations were applied to get the parameters; excitability threshold (ET), amplitude and latency of MEP. We also had a facilitated MEP (fMEP). Results: The parameters were analyzed according to the clinical settings. ET was higher in ALS(mean $63.5{\pm}18.1$) than normal control (mean $46.0{\pm}8.4$, p<0.01). Amplitudes of MEP were reduced in ALS ($2.6{\pm}3.6mV$; control $6.5{\pm}3.1mV$, p<0.01). Duration of the disease and ET showed significant inverse correlation (Spearson correlation coefficient = -0.57, p<0.01). Duration of the disease and fMEP/MEP ratio showed less but also significant inverse correlation (Spearson correlation coefficient, r = -0.52, p < 0.05). Conclusions: Lower ET in advanced ALS patients, in spite of decreased fMEP/MEP ratio, may indicate the hyperexcitability of lower motor neurons in these patients. This study suggests that lower motor neurons is hyperexcitable due to upper motor neuron dysfunction at advanced stage.

  • PDF

A Study on Transcranial Magnetic Electrode Simulation Using Maxwell 3D (Maxwell 3D를 이용한 경두개 자기 전극 시뮬레이션에 관한 연구)

  • Lee, Geun-Yong;Yoon, Se-Jin;Jeong, Jin-hyoung;Kim, Jun-Tae;Lee, Sang-sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.657-665
    • /
    • 2019
  • In this study, we conducted a study on the transcranial magnetic electrode, a method for the study of dementia and muscle pain, a neurodegenerative disease caused by an aging society, which is becoming a problem worldwide. In particular, transcranial magnetic electrodes have been studied to improve their ability to be deteriorated by dementia symptoms such as speech, cognitive ability, and memory by outputting magnetism deep into the brain using coils on the head epidermis. In this study, simulation was performed using Maxwell 3D program for the design of coil, the core of transcranial magnetic electrode. As a result of the simulation comparison between the coil designed by the previous research and the coil through the research and development, the output was found to be superior to the conventional designed coil. The graphs of the coil outputs of B-Field and H-Field are found to be symmetrical, but the symmetry between each coil is pseudo-symmetrical and not accurate. Based on these results, an experiment was conducted to confirm whether the output of the head epidermis through both coils is possible. In the magnitude field of the reverse-coil 2-coil analysis, the maximum output was 3.3920e + 004 H [A_per_meter], and the vector field showed the strongest magnetic field around 35 to 165 degrees. It was confirmed that the magnetic output canceled due to the magnetic output. In the case of the forward 2-coil, a maximum of 3.2348e + 004H [A_per_meter] similar to the reverse coil was observed, but in the case of the vector field, the magnetic output regarding the forward output and the head skin output was confirmed. However, when the height change in the output coil, the magnetic output was reduced.

Effect of the application of low-frequency rTMS on cognitive function in chronic stroke patients (저빈도 rTMS의 적용이 만성 뇌졸중환자의 인지기능에 미치는 영향)

  • Lee, Dong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7239-7247
    • /
    • 2014
  • This study repeated low-frequency transcranial magnetic stimulation (rTMS) to evaluate the effects on cognitive function in chronic stroke patients. Among the chronic stroke patients, 30 patients selected by MMSE-K and BCRS-K were divided randomly into 3 groups. Group I (n=10) had only sound applied, group II (n=10) were applied 1 Hz rTMS on the damaged side and group III (n=10) were applied to 1 Hz rTMS on the opposite side for total 2 weeks, 20 minutes per a day, five times per a week. To examine the change in cognitive function, CREAD-K scores were measured before, 1 week, 2 weeks, and then 3 months after the intervention. The CREAD-K scores were measured before and 1 week, 2 weeks and 3 months after the interventions. The immediate recall memory showed a significant difference after 2 weeks and 3 months in groups II and III (p<.05), The recognition memory showed a significant difference after 2 weeks and 3 months in group III (p<.05). The delayed recall memory showed significant differences after 3 months in group III than in group I (p<.05). Therefore, the application of low-frequency rTMS has a positive influence on the cognitive rehabilitation of chronic stroke patients.

Evidence of Cortical Reorganization in a Monoparetic Patient with Cerebral Palsy Detected by Combined Functional MRI and TMS

  • Kwon, Yong-Hyun;Jang, Sung-Ho;Lee, Mi-Young;Byun, Woo-Mok;Cho, Yoon-Woo;Ahn, Sang-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.96-103
    • /
    • 2005
  • The motor recovery mechanism of a 21-year-old male monoparetic patient with cerebral palsy, who had complained of a mild weakness on his right hand since infancy, was examined using functional Magnetic Resonance Imaging (fMRI) and Transcranial Magnetic Stimulation (TMS). The patient showed mild motor impairment on the right hand. MRI located the main lesion on the left precentral knob of the brain. fMRI was performed on this patient as well as 8 control subjects using the Blood Oxygen Level Dependent technique at 1.5 T with a standard head coil. The motor activation task consisted of finger flexionextension exercises at 1 Hz cycles. TMS was carried out using a round coil. The anterior portion of the coil was applied tangentially to the scalp at a 1.0 cm separation. Magnetic stimulation was carried out with the maximal output. The Motor Evoked Potentials (MEPs) from both Abductor Pollicis Brevis muscles (APB) were obtained simultaneously. fMRI revealed that the unaffected (right) primary sensori-motor cortex (SM1), which was centered on precentral knob, was activated by the hand movements of the control subjects as well as by the unaffected (left) hand movements of the patient. However, the affected(right) hand movements of the patient activated the medial portion of the injured precentral knob of the left SM1. The optimal scalp site for the affected (right) APB was located at 1 cm medial to that of the unaffected (left) APB. When the optimal scalp site was stimulated, the MEP characteristics from the affected (right) APB showed a delayed latency, lower amplitude, and a distorted figure compared with that of the unaffected (left) APB. Therefore, the motor function of the affected (right) hand was shown to be reorganized in the medial portion of the injured precentral knob.

  • PDF