• 제목/요약/키워드: TMDLs

검색결과 70건 처리시간 0.031초

수질오염총량관리 목표수질 초과지역에 대한 유황별 초과기여도 분석 (Contributions to the Impaired Water Bodies by Hydrologic Conditions for the Management of Total Maximum Daily Loads)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.574-581
    • /
    • 2012
  • It is important to analyze the status of water quality with relation to the stream flow to attain water quality goal more effectively in the unit watersheds for the management of Total Maximum Daily Loads (TMDLs). This study developed a flow duration-water quality distribution graph to figure out water quality appearances on the flow variation and analyzed contributions of water quality observations to the impaired water bodies quantitatively by hydrologic conditions. Factors relating to water quality variation can be analyzed more precisely and assessed on the base of quantified contributions. It is considered that this approach could be utilized to establish a more effective plan for the water quality improvement including the prioritization of pollution reduction options.

하천유지유량을 이용한 일최대 오염허용부하량 산정 방안 (Calculation of Total Maximum Daily Load using Instreamflow Requirement)

  • 정은성;김경태;김상욱;이길성
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.317-327
    • /
    • 2008
  • This study developed the methodology to calculate the total daily maximum load (TMDL) using the instreamflow requirement because the previous TMDLs were too simple to easily achieve. Instreamflow requirement which was the average low flow ($Q_{275}$) in the previous planning cannot consider the seasonal variation of streamflow. Therefore, this study used the instreamflow requirement which is a maximum value among hydrologic drought flow ($Q_{355}$), and environmental flows for ecology and scenery. The environmental flows for ecology were calculated using Physical HABitat SIMulation system (PHABSIM) which can estimate the necessary flow for fish survival by life cycle. Using the proposed method, all monthly TMDLs of streams in the Anyangcheon were calculated for the application.

수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로 (Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin)

  • 박준대;최옥연;오승영
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

미계측 유역에서 저수량 산정 방법 비교 연구 (Comparative Study on Evaluating Low-Flow in Ungauged Watershed)

  • 백경오
    • 한국안전학회지
    • /
    • 제29권1호
    • /
    • pp.31-36
    • /
    • 2014
  • In this study, the methodologies for evaluating the low-flow at the ungauged watershed are reviewed and assessed. The ungauged watershed can be classified into different situations such as the partially recorded watershed and the completely ungauged watershed. The extension method and the percentile method are used to evaluated the low-flow at the partially recorded watershed. The drainage-area ratio method and the regional regression method are used at the completely ungauged watershed. These four methods are applied and validated based on the hydrological and geometric data acquired from unit watersheds in Han River basin for TMDLs. In case of partially recorded watershed, the values of low-flow evaluated by the extension method are in better agreement with measured flow-rate rather than those by the percentile method. In case of completely ungauged watershed, the drainage-area method is broadly used to estimate the low-flow. It must be paid attention to consider the treated sewage discharge produced at watersheds when applying the method.

유량지속곡선을 이용한 수문특성별 한강수계 총량관리 단위유역의 오염기여도 추정 (Estimation of Pollution Contribution TMDL Unit Watershed in Han-River according to hydrological characteristic using Flow Duration Curve)

  • 김동영;윤춘경;이한필;최재호;황하선
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.497-509
    • /
    • 2019
  • After the Total Maximum Daily Loads(TMDLs) was applied, it became beyond the limit of concentration management. However, it does not adequately reflect the characteristics of various watersheds, and causes problems with local governments because of the standard flow set. Thus, in this study, the Han River system is organized into four groups in estimating the Pollution Contribution by applying the Flow Duration Curve(FDC) created by the daily flow of data from the HSPF. And the method of this study is expected to be valuable as basic data for the TMDLs. As a result, Group I contains the main watersheds with no large hydraulic structures and tributary watersheds. There is no specificity in the FDC and the Pollution Contribution is estimated as rainfall runoff. Group II contains watersheds near the city where the FDC is maintained above a certain level during the Low Flow Conditions and the Pollution Contribution is estimated as the discharge flow of large scale point pollution facilities. Group III contains the main watersheds in which the large hydraulic structures are installed and FDC is curved in the Low Flow Conditions. So the Pollution Contribution is estimated as the water quality of the large hydraulic structures. Group IV contains the upstream in mainstream watersheds in which the large hydraulic structures are installed and the FDC is disabled before the Low Flow Conditions. As the flow is concentrated in the High Flow Conditions, the non-point pollution sources are estimated as the Pollution Contribution.

수질오염총량관리제에서 난분해성 유기물질 관리 필요성 및 개선방안 (Necessity of Refractory Organic Matters Management in Total Maximum Daily Loads (TMDLs))

  • 박재홍;박배경;이재관;류덕희
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.393-399
    • /
    • 2013
  • To control organic matters, it needs to manage not only biodegradable organic matters but also refractory organic matters. Refractory organic matters from municipal wastewater, industrial wastewater, non-point sources and etc., have been continuously discharged to the near watersheds. It is estimated that the refractory organic matter ratios are continuously increased in waterbody. In watersheds of the Total Maximum Daily Loads (TMDLs), it was investigated that COD/BOD ratios increased in many unit watersheds of the 4 major river basins. The portions COD/BOD ratios increased were found to be a 97% of Geum River unit watersheds, a 81% of Yeongsan/Seumjin River unit watersheds, a 78% of Nakdong River unit watersheds, a 70% of Han River unit watersheds, respectively. Therefore, it has become important for establishment of effective management strategies to control refractory organic matter in watersheds of the Total Maximum Daily Loads (TMDLs). In order to properly manage organic matters including refractory organic matters, the present organic indicator (BOD) has to be converted to TOC (or COD). Compared to COD and BOD, TOC, as a organic matter indicator, is evaluated more appropriate.

수질오염총량관리를 위한 대상물질 적용성 분석 (Applicability of Water Quality Indicators as Target Pollutants for Total Maximum Daily Loads)

  • 박준대;오승영;박재홍
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.531-539
    • /
    • 2013
  • In order to apply a water quality indicator as a certain target pollutant, the indicator should have the representability of an index for the management of Total Maximum Daily Loads (TMDLs). Scientific groundwork and treatment technologies also should be provided for the application of the indicator. This study analyzed the applicability of major water quality indicators for target pollutants. The results showed that four water quality indicators of TOC, T-N, SS & T-Coli can be considered as target pollutants besides existing BOD and T-P. These indicators can be applied with the preparations such as essential basic data, pollution load estimation framework as well as legal criteria setting when the need is raised. As the importance of TOC, which is considered as a replacement of BOD, is emphasized, technical and institutional terms are being prepared in order to determine TOC as another target pollutant in the near future. It could be considered to combine TOC with BOD for the time being during the $3^{rd}$ stage of TMDLs in view of the present conditions for the management of TOC. TOC can be the most effective index for the organic matter and help to be managed more systematically in the waterbodies where rivers and lakes are mutually connected.

수질오염총량관리 대상물질 선정을 위한 하천수질 평가 (Evaluation of Stream Water Quality to Select Target Indicators for the Management of Total Maximum Daily Loads)

  • 박준대;박재홍;오승영;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.630-640
    • /
    • 2013
  • It is one of the most critical steps identifying impaired waterbodies exactly in the selection of target water quality indicators for the management of Total Maximum Daily Loads (TMDLs). Excess ratio and excess level were applied and analyzed by the stream zone basis in order to evaluate water impairment for Nakdong, Geum, Youngsan and Seomjin rivers. Each river basin was divided into stream zones in the light of its watershed and waterbody characteristics. Selected water quality parameters discussed in this study were pH, DO, BOD, COD, SS, T-P, T-Coli and F-Coli. The excess ratios of the water quality parameters were used to discriminate water bodies that did not meet water quality standards. The excess levels were used to classify the degradation of water quality. The excess ratios and the excess levels to the water quality criteria of the medium influence areas were used for each stream zone. The results indicate that the excess ratios and the excess levels are varied on the stream zone in each river basin. Three parameters, pH, DO and SS, met water quality standards in all stream zones. The other five parameters indicated very high excess ratios in most waterbodies, and especially T-P and T-Coli revealed to be very high excess levels in some waterbodies. These parameters could be considered as major target indicators for the management of TMDLs.

최적화 모델을 이용한 경제적인 총량관리 할당기법 연구 (The Allocation Methods for Economical Efficiency Using an Optimized Model)

  • 최인욱;신동석;김홍태;박재홍;안기홍;김용석
    • 한국물환경학회지
    • /
    • 제31권3호
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

수질오염총량관리제의 성과평가: 개발/삭감계획의 이행실적 및 단위유역의 수질 현황 (Performance Appraisal of Total Maximum Daily Loads: Performance on Development/Reduction Plan and Water Quality Status of Unit Watershed)

  • 박재홍;박준대;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.481-493
    • /
    • 2009
  • This study was conducted to performance appraisal of Total Maximum Daily Loads (TMDLs), especially in terms of performance on development & reduction plan and water quality status of unit watershed. Because load allocations for pollution sources were predicted redundantly by uncertainty of prediction, TMDLs master plan has been frequently changed to acquire load allocation for local development. Therefore, It need to be developed more resonable prediction techniques of water pollution sources to preventing the frequent change. It is suggested that the reduction amount have to be distributed properly during the planning period. In other words, it has not to be concentrated on the specific year (especially final year of the planning period). The reason why, if the reduction amount concentrate on the final year of the planning period, allotment loading amount could not be achieved in some cases (e.g., insufficiency of budget, extension of construction duration). If the development plan was developed including uncertain developments, it is necessary to be developed reduction plan considered with them. However, some of the plans in the reduction plan could not be accomplished in some case. Because, it is not considered financial abilities of local governments. Consequently, development plan must be accomplished to avoid uncertain developments, and to consider financial assistance to support the implementation of effective plan. Water quality has been improved in many unit watersheds due to the TMDLs, especially in geum river and yeongsang/seomjin river.