• Title/Summary/Keyword: TM9

Search Result 638, Processing Time 0.025 seconds

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Tubulogenesis of TM4 Sertoli cells in vitro

  • Park, Seung-Ho;Park, Jin-Kook;Gye, Myung-Chan
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2001.08a
    • /
    • pp.38-38
    • /
    • 2001
  • TM4 Sertoli cell의 체외 관강형성 유도에 미치는 세포외기질 (ECM) 및 hepatocyte growth factor (HGF)의 역할과 세포분화 과정에서 MMP의 발현의 변화를 조사하였다. Matrigel bed(60%, v/v) 상에서 배양한 TM4 cell은 무혈청 조건하에서 chain 분화단계를 거쳐 cord의 구조로 분화하였다. 그러나 이후의 분화는 일어나지 않았다. TM4 cell에서 c-MET (HGF receptor)의 발현을 확인하였으며 HGF를 첨가한 배양액에서 분화가 촉진되었으며, cord에서 tubule로의 분화가 유도되었다. 또한 TM4 cell의 분화는 MMP-2 및 MMP-9의 발현이 증가를 수반하였으며 HGF는 MMPs의 발현을 증가시켰다. GFR-Matrigel과 성장인자인 HGF는 무혈청 배지에서 TM4 cell의 체외에서 관강형성에 필요한 환경을 제공하며, MMP-2 및 -9은 TM4 cell의 체외분화 과정에서 조절역할을 수행하는 것으로 사료된다.

  • PDF

Monitoring of Rice Growth by RADARSAT and Landsat TM data (RADARSAT과 Landsat TM자료를 이용한 벼 생육모니터링)

  • Hong Suk-Young;Rim Sang-Kyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.1
    • /
    • pp.9-15
    • /
    • 2000
  • The objective of this study is to evaluate the use of RADARSAT and Landsat TM data for the monitoring of rice growth. The relationships between backscatter coefficients($\sigma$$^{0}$ ) of RADARSAT data and digital numbers (DN) of Landsat TM and rice growth parameters were investigated. Radar backscatter coefficients were calculated by calibration process and then compared with rice growth parameters; plant height, leaf area index (LAI), and fresh and dry biomass. When radar backscatter coefficient ($\sigma$$^{0}$ ) of rice was expressed as a function of time, it is shown that the increasing trend ranged from -22--20dB to -9--8dB as growth advances. The temporal variation of backscatter coefficient was significant to interpret rice growth. According to the relationship between leaf area index and backscatter coefficient, backscatter coefficient underestimated leaf area index at the beginning of life history and overestimated, at the reproductive stage. The same increasing trend between biomass and backscatter coefficient was shown. From these results, RADARSAT data appear positive to the monitoring of rice growth. Each band of time-series Landsat TM data had a significant trend as a rice crop grows during its life cycle. Spectral indices, NDVI[(TM4-TM3)/(TM4+TM3)] and RVI(TM4/TM2), derived from Landsat TM equivalent bands had the same trend as leaf area index.

  • PDF

The Carboxyl Terminal Amino Acid Residues Glutamine276-Threonine277 Are Important for Actin Affinity of the Unacetylated Smooth ${\alpha}$-Tropomyosin

  • Cho, Young-Joon
    • BMB Reports
    • /
    • v.33 no.6
    • /
    • pp.531-536
    • /
    • 2000
  • Tropomyosin (TM) is an important actin binding protein involved in regulation of muscle contraction. Unacetylated striated tropomyosin failed to bind to actin whereas unacetylated smooth tropomyosin bound well to actin. It has been demonstrated that high actin affinity of unacetylated ${\alpha}-tropomyosin$ was ascribed to the carboxyl terminal amino acid residues. In order to define the role of the carboxyl terminal residues of tropomyosin molecule on actin binding, two mutant tropomyosins were constructed. TM11 is identical to the striated tropomyosin except that the carboxyl terminal last three amino acids was replaced with $^{282}NNM^{284}$ whereas in TM14 $^{276}HA^{277}$ was substituted with smooth specific $^{276}QT^{277}$. TM11 and TM14 were overproduced in Escherichia coli and analyzed for actin affinity. The apparent binding constants (Kapp) of unacetylated tropomyosins were $2.2{\times}10^6M^{-1}$ for sm9, $1.03{\times}10^6M^{-1}$ for TM14, $0.19{\times}10^6M^{-1}$ for TM11, $>0.1{\times}10^6M^{-1}$ for striated, respectively. This result indicated that higher actin affinity of the unacetylated smooth tropomyosin was primarily attributed to the presence of QT residues in the smooth sequence. In case of the Ala-Ser (AS) dipeptide extension of the amino terminus of tropomyosin, Kapp were $21.1{\times}10^6M^{-1}$ for AS-sm9, $8.0{\times}10^6M^{-1}$ for AS-11, $4.7{\times}10^6M^{-1}$ for AS-14, $3.8{\times}10^6M^{-1}$ for AS-striated. AS-TM11 showed considerably higher actin affinity than AS-TM14, implying that interaction of Ala-Ser of the amino terminus with the carboxyl terminal residues. Since Kapp of AS-TM11 was significantly lower than that of AS-sm9, the presence of QT might be required for restoration of high actin affinity of the smooth ${\alpha}-tropomyosin$. These results suggested that the carboxyl terminal amino acid residues Glutamine275-Threonine276 are important for actin affinity of the recombinant smooth ${\alpha}-tropomyosin$, particularly of unacetylated smooth ${\alpha}-tropomyosin$.

  • PDF

TM4SF5-mediated protein-protein networks and tumorigenic roles

  • Lee, Jung Weon
    • BMB Reports
    • /
    • v.47 no.9
    • /
    • pp.483-487
    • /
    • 2014
  • Transmembrane 4 L six family member 5 (TM4SF5), as a membrane glycoprotein with 4 transmembrane domains, is similar to the tetraspanins in terms of membrane topology and plays important roles in tumorigenesis and tumor metastasis. Especially, TM4SF5 appears to form a massive protein-protein complex consisting of diverse membrane proteins and/or receptors in addition to cytosolic signaling molecules to regulate their signaling activities during the pathological processes. TM4SF5 is shown to interact with integrins ${\alpha}2$, ${\alpha}5$, and ${\beta}1$, EGFR, IL6R, CD151, focal adhesion kinase (FAK), and c-Src. This review focuses on the significance of the interactions with regards to TM4SF5-positive tumorigenesis and metastasis.

Evaluation of Rapid Diagnostics for Plasmodium falciparum and P. vivax in Mae Sot Malaria Endemic Area, Thailand

  • Chaijaroenkul, Wanna;Wongchai, Thanee;Ruangweerayut, Ronnatrai;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Prompt and accurate diagnosis of malaria is the key to prevent disease morbidity and mortality. This study was carried out to evaluate diagnostic performance of 3 commercial rapid detection tests (RDTs), i.e., Malaria Antigen Pf/Pan$^{TM}$, Malaria Ag-Pf$^{TM}$, and Malaria Ag-Pv$^{TM}$ tests, in comparison with the microscopic and PCR methods. A total of 460 blood samples microscopically positive for Plasmodium falciparum (211 samples), P. vivax (218), mixed with P. falciparum and P. vivax (30), or P. ovale (1), and 124 samples of healthy subjects or patients with other fever-related infections, were collected. The sensitivities of Malaria Ag-Pf$^{TM}$ and Malaria Antigen Pf/Pan$^{TM}$ compared with the microscopic method for P. falciparum or P. vivax detection were 97.6% and 99.0%, or 98.6% and 99.0%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, and Malaria Antigen Pf/Pan$^{TM}$ were 93.3%,98.8%, and 94.4%, respectively. The sensitivities of Malaria Ag-Pf$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method, when PCR was used as a reference method for P. falciparum or P. vivax detection were 91.8%, 100%, and 96.7%, or 91.9%,92.6%, and 97.3%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method were 66.2%, 92.7%, 73.9%, and 78.2%, respectively. Results indicated that the diagnostic performances of all the commercial RDTs are satisfactory for application to malaria diagnosis.

Usefulness of the $UBC^{TM}$ (Urinary Bladder Cancer) Test Compared to Urinary Cytology for Transitional Cell Carcinoma of the Bladder in Patients with Hematuria (혈뇨 환자의 방광암 진단에서 $UBC^{TM}$ (Urinary Bladder Cancer) 검사의 유용성)

  • Gil, Myung-Cheol;Kang, Do-Young;Seong, Youl-Koon;Jung, Se-Il;Kwon, Hyon-Young;Jung, Gyung-Woo;Kim, Duk-Kyu;Roh, Mee-Sook;Hwang, Tae-Ho;Yoon, Jin-Han
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.192-197
    • /
    • 2001
  • Purpose: Urinary cytology and cystoscopic exam are effective methods for diagnosis of transitional cell carcinoma(TCC). But the former shows drawbacks such as the need for a well-trained examiner, and wide imprecision related to the variability of microscopic exam; the latter is an invasive method. $UBC^{TM}$ test detects the epitope on specific cytokeratin fragments released from epithelium of bladder cancer by immunoradiometric assay. We compared $UBC^{TM}$ test with urinary cytology for diagnosis of TCC to evaluate the utility of $UBC^{TM}$ test. Materials and Methods: Eighty-four patients with hematuria were included in our study. $UBC^{TM}$ tests (IDL Biotech, Sweden) were assayed in mid-stream urine according to the ordinary assay protocol. Nineteen patients were confirmed as TCC by cystoscopic examination and underwent transurethral resection (Group A). Other patients had various benign urinary tract conditions (Group B). Samples were considered positive as the $UBC^{TM}$ concentration was greater than $12{\mu}g/L$. Results: $UBC^{TM}$ levels were significantly different between group A ($95.9{\pm}166.4\;{\mu}g/L$) and group B ($19.2{\pm}85.6{\mu}g/L$) (P<0.001). Sensitivity for diagnosis of TCC was 89.5% (17/19) in UBC test and 47.4% (9/19) in cytology (p<0.05). Specificity for diagnosis of TCC was 81.5% (53/65) in $UBC^{TM}$ test and 100% (65/65) in cytology. $UBC^{TM}$ test was significantly more sensitive in stage Ta, $T_1$ tumors (84.6 vs 38.5%, p<0.05) and in grade I (83.3% vs 16.7%, p<0.05) than cytology. $UBC^{TM}$ test showed a tendency to be more sensitive as the grade was higher (83.3% in Grade I, 90% in Grade II and 100% in Grade III). Conclusion: $UBC^{TM}$ test could be a useful method in distinguishing TCC from other benign genitourinary diseases. Moreover, $UBC^{TM}$ test could be an especially valuable marker for diagnosis of TCC in patients with early TCC of low grade TCC compared to urinary cytology. Therefore, mbined use of $UBC^{TM}$ test in association with cytology is helpful to overcome the limited sensitivity of cytology.

  • PDF

Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.

Liquid-Based Cytology Using $MonoPrep2^{TM}$ System in Cervicovaginal Cytology: Comparative Study with Conventional Pap Smear and Histology (고식적 직접 도말법과 $MonoPrep2^{TM}$ system 법에 의한 자궁경부질 세포검사 성적의 비교 검토)

  • Jeon, Yoon-Kyung;Kim, Ok-Ran;Park, Ki-Wha;Kang, Soon-Beom;Park, In-Ae
    • The Korean Journal of Cytopathology
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • We compared the diagnostic accuracy of liquid-based cervicovaginal cytology using $MonoPrep2^{TM}$ system (Monogen, Herndon, Virginia, USA), a manual system based on membrane filtration method, with conventional Pap smear. Study population included 92 patients visiting the gynecologic department under the suspicion of uterine cervical disease. In thirty of them, surgical biopsy was performed. $MonoPrep2^{TM}$ system provided well-preserved monolayer specimen with good nuclear morphology. However, about 19% of specimens were inadequate to interpret due to low cellularity. The detection rate of abnormal cells more than ASCUS (atypical squamous cells of unknown significance) was 23.9% and higher than 19.4 % of conventional Pap smear. Diagnostic concordance rate with conventional Pap smear was 81%, and severe discordance rate influencing on the management of patient was 7.6 %. Among these seven cases, $MonoPrep2^{TM}$ system was more diagnostic only in four. In comparison with histology, the sensitivity of diagnosis of $MonoPrep2^{TM}$ system was 78.9% and slightly higher than 73.5% of conventional Pap smear. However, the specificity was 81.1% and lower than 90.9% of Pap smear. In conclusion, $MonoPrep2^{TM}$ system provided diagnostic accuracies similar to the conventional Pap smear. The inexpertness of slide preparation and the low cellularity were considered to endow a limitation in more accurate evaluation.