• Title/Summary/Keyword: TM5

Search Result 1,575, Processing Time 0.034 seconds

Effect of Oroxylin A on Hydrogen Peroxide Production in Polyinosinic-Polycytidylic acid-induced TM4 Mouse Testis Sertoli Cells (Oroxylin A가 polyinosinic-polycytidylic acid로 유발된 생쥐 서톨리세포 TM4의 hydrogen peroxide 생성증가에 미치는 영향)

  • Park, Wan Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.384-389
    • /
    • 2014
  • The purpose of this study is to investigate the modulatory effect of oroxylin A on hydrogen peroxide production in TM4 mouse testis sertoli cells induced by the synthetic analog of double-stranded RNA [polyinosinic-polycytidylic acid]. Hydrogen peroxide production was measured by dihydrorhodamine 123 (DHR) assay. Oroxylin A significantly inhibited the polyinosinic-polycytidylic acid (PIC)-induced production of hydrogen peroxide for 0.5, 2, 12, 18, and 24 hr incubation at the concentrations of 5, 10, 25, and $50{\mu}M$ in TM4 (P < 0.05) in dose dependent manner. These results suggest that oroxylin A has a protective effect against PIC-induced cellular toxicity with its inhibition of hydrogen peroxide production in PIC-induced sertoli cells.

Temperature Variation by Terrain Using Multitemporal TM Band 6 and DEM(With Seoul City Area) (다시기 TM 밴드 6와 DEM을 이용한 지형별 온도변화(서울시 영역을 대상으로))

  • 박민호
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.203-210
    • /
    • 2004
  • The average temperatures by the land cover class, by the elevation extent, by the slope and by the aspect have been calculated using multitemporal Landsat TM band 6 and DEM. For this, the TM band 6 data from October 21, 1985, June 2, 1992, September 1, 1996, May 7, 2000 and the 28.5m x 28.5m grid elevation data of Seoul have been used. From the varying curve of the average land surface temperature by the elevation extent, the presence of the atmospheric inversion phenomenon and the scope of the inversion layer can be inferred. Especially, the average land surface temperature by the aspect can be effective for deciding a road line. For these reasons, it is expected that temperature estimation using remote sensing data shall be effective for the survey of heat damage, environmental temperature monitoring, and urban and environmental Planning usage.

  • PDF

A STUDY OF SHEAR BOND STRENGTH OF ER:YAG LASER-IRRADIATED PRIMARY DENTIN (Er:YAG 레이저를 조사한 유치 상아질의 전단결합강도에 관한 연구)

  • Lee, Jin-Hwa;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.569-578
    • /
    • 2007
  • This study was performed to compare the shear bond strength of self etching system and two bottle bonding system with or without laser preparation. Group I was prepared with high speed rotary instrument and $Prompt^{TM}$ L-$Pop^{TM}$, group II with Er:YAG laser and $Prompt^{TM}$ L-$Pop^{TM}$, group III with Er:YAG laser, 37% phosphoric acid and Single bond, group IV with Er:YAG laser and Single bond and group V with high speed, etching and Single bond. And also observation of the prepared and etched dentin surface were performed under scanning electro-microscope. The possibility of clinical application of laser preparation which might have an advantage to reduce pain for children with less unfavorable noise were evaluated. The results obtained are as follows; 1. Group V showed significantly higher bond strength than other groups. And group IV showed significantly lower bond strength than other groups. 2. There was no significant difference between group I and group III. 3. Group II showed significantly lower bond strength than group I, III, V, but showed significantly higher bond strength than group IV. 4. Under scanning electro-microscope, laser-preparated dentin surface showed high irregularity and no smear layer. The surface showed less irregularities and more exposed dentinal tubules with etching. Laser preparation has many advantages over conventional tooth preparation. But this method showed lower resin bonding strength. Laser preparated tooth surface differed from the conventionally preparated tooth surface. More researches are needed on suitable methods for laser preparated dentin surface.

  • PDF

Distribution of Surface Temperature and Chlorophyll-a in Lake Soyang using Remote Sensing Techniques (원격탐사기법에 의한 소양호의 표층수온과 엽록소 분포)

  • Jeong, Jong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.177-183
    • /
    • 2000
  • The Landsat Thematic Mapper (TM) has suggested that spatial and spectral characteristics would be suited to evaluate water quality of lake. But, TM has not been commonly used for the analysis of in-land water quality, such as surface water temperature, chlorophyll-a, suspended sediments, and Secchi depth in domestic research. This paper summarizes the analysis of Landsat 5 - TM image collected on 22 Feb 1996 for evaluation of chlorophyll-a and surface temperature in the Lake Soyang. And, field measurements collected in the Lake Soyang were used to obtain water optical algorithms for calibration of satellite data. It is concluded that we can assess chlorophyll-a with remote sensing reflectance and surface temperature with thermal band in lake Soyang. However, surface temperature calculated with thermal band of Landsat TM are underestimated. Relationship between remote sensing reflectance and chlorophyll-a using the ratio of TM band 1 and band 3 is as follows; Y = 17.206 - 6.4711 * (Rrs(band1) / Rrs(band3)) $R^2$=0.8762 and, using the ratio of TM band 1 and band 2 as follows; Y = 57.77 - 35.771 * (Rrs(band1) / Rrs(band2)) $R^2$=0.8317.

  • PDF

STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM (우치에 대한 All-in-one 상아질 결합제의 전단결합강도 비교 연구)

  • Park, Hyung-Joo;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.661-672
    • /
    • 2006
  • This study was performed to compare the shear bond strength of AQ Bond $Plus^{TM}$ with AQ $Bond^{TM}$ and Single $Bond^{TM}$. Also by observing the fractured interface under scanning electro-microscope, the fracture pattern and the quality of hybrid layer were analyzed. The possibility of clinical application of all-in-one system which has an advantage to reduce chair time for children with difficult behavior pattern was evaluated, The results obtained are as follows ; 1. There was no significant difference between AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$ in shear bond strength and Single Bond showed the highest bond strength with statistical significant difference (p<0.05). 2. Adhesive fracture pattern was mainly observed in both enamel/dentin in AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$ group while Single Bond group showed equal numbers for cohesive and adhesive pattern. 3. Under scanning electro-microscope, resin tags observed in AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$ were very weak and tangled while strong and thick tags were shown with many lateral branches in Single Bond. Careful case selection and accurate clinical application is recommended when using AQ $Bond^{TM}$ and AQ Bond $Plus^{TM}$considering the result showing its weaker strength than Single $Bond^{TM}$.

  • PDF

Electrical properties and degradation behavior of Tm2O3 doped barium titanate ceramics for MLCCs (Tm2O3가 첨가된 MLCC용 BaTiO3 유전체의 전기적 특성 및 열화거동)

  • Kim, Do-Wan;Kim, Jin-Seong;Hui, K.N.;Lee, Hee-Soo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.6
    • /
    • pp.278-282
    • /
    • 2010
  • The doping effect of thulium on electrical properties and degradation behavior in barium titanate ceramics ($BaTiO_3$) was investigated in terms of generations of core-shell structure and micro-chemical changes through highly accelerated degradation test. The dielectric specimens of pellet type and multi-layered sheets were prepared by using $BaTiO_3$ with undoped and doped with 1 mol% $Tm_2O_3$. The $BaTiO_3$ ceramics doped with 1 mol% $Tm_2O_3$ had 40% higher dielectric constant (${\varepsilon}$ = 2700) than that of the undoped $BaTiO_3$ specimen at curie temperature and met X7R specification. According to the result of highly accelerated degradation test conducted at $150^{\circ}C$, 70 V, and 24 hr, the oxygen diffusion was declined in dielectrics doped with 1 mol% $Tm_2O_3$. The $Tm^{3+}$ ion substituted selectively Ba site and Ti site and contributed to the generation of the core-shell structure. Oxygen vacancies occurred by substitution for Ti site could reduce excess oxygen that reacted to the Ni electrode.

The Operative Treatment of Displaced Intra-articular Calcaneal Fracture with Injectable Calcium Sulfate ($MIIG^{TM}$) (주사형 황산 칼슘($MIIG^{TM}$)을 이용한 전위성 종골 관절내 골절의 수술적 치료)

  • Ahn, Seong-Jun;Kim, Bu-Hwan;Song, Moo-Ho;Yoo, Seong-Ho;Seo, Sang-Hyok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.221-225
    • /
    • 2007
  • Purpose: To evaluate the clinical results of operative treatment of the intra-articular calcaneal fracture with injectable calcium sulfate ($MIIG^{TM}$). Materials and Methods: Between March 2004 and October 2006, a total 19 intra-articular calcaneal fracture (16 patients) with a large bony defect that underwent operative treatment with plate fixation and injectable calcium sulfate ($MIIG^{TM}$) with minimum follow-up of one year following. The mean age at time of surgery was 44.7 years (23 to 54). All of the cases were type 2 and 3 on the basis of Sanders classification. The lateral L shaped approach was used in all cases. Full weight bearing on the affected extremity was regained at an average 10 weeks postoperatively. Results: The mean Bohler angle was improved from $2^{\circ}$ ($-18.5{\sim}12.5^{\circ}$) preoperatively to $23.8^{\circ}$ ($12{\sim}37.5^{\circ}$) and the angle at last follow-up was $22.5^{\circ}$ ($11.5{\sim}37.5^{\circ}$), showing about 0.3 degree decline compared to postoperative Bohler angle. Only two case of whitish leakage of graft material but other complication were none. Conclusion: $MIIG^{TM}$ augumentation of displaced intra-articular calcaneal fracture with large bone defect seems to bo useful method for initial stabilized and plate fixation.

  • PDF

Sarcocystosis among Wild Captive and Zoo Animals in Malaysia

  • Latif, Baha;Vellayan, Subramaniam;Omar, Effat;Abdullah, Suliman;Desa, Noryatimah Mat
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Sarcocystis sp. infection was investigated in 20 necropsied captive wild mammals and 20 birds in 2 petting zoos in Malaysia. The gross post-mortem lesions in mammals showed marbling of the liver with uniform congestion of the intestine, and for birds, there was atrophy of the sternal muscles with hemorrhage and edema of the lungs in 2 birds. Naked eye examination was used for detection of macroscopic sarcocysts, and muscle squash for microscopic type. Only microscopically visible cysts were detected in 8 animals and species identification was not possible. Histological examination of the sections of infected skeletal muscles showed more than 5 sarcocysts in each specimen. No leukocytic infiltration was seen in affected organs. The shape of the cysts was elongated or Circular, and the mean size reached $254{\times}24.5{\mu}m$ and the thickness of the wall up to $2.5{\mu}m$. Two stages were recognized in the cysts, the peripheral metrocytes and large numbers of crescent shaped merozoites. Out of 40 animals examined, 3 mammals and 5 birds were positive (20%). The infection rate was 15% and 25% in mammals and birds, respectively. Regarding the organs, the infection rate was 50% in the skeletal muscles followed by tongue and heart (37.5%), diaphragm (25%), and esophagus (12.5%). Further ultrastructural studies are required to identify the species of Sarcocystis that infect captive wild animals and their possible role in zoonosis.

Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom (Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Lim, Chang-Seon;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.137-143
    • /
    • 2009
  • This study was conducted to evaluate the accuracy of CyberKnife $Synchrony^{TM}$ respiratory tracking system which was applied to Stereotactic Radiosurgery (SRS) for moving tumors in chest and abdomen with breathing motion. For accurate evaluation, gold fiducial marks were implanted into a moving phantom. The moving phantom was a cube imbedding an acryl ball as a target. The acryl ball was prescribed to 20 Gy at 70% of isodose curve in a virtual treatment and radiochromic films were inserted into the acryl ball for dose verification and tracking accuracy evaluation. The evaluation of position tracking consists of two parts: fiducial mark tracking in a stationary phantom and $Synchrony^{TM}$ respiratory tracking in a moving phantom. Each measurement was done in three directions and was repeated to 5 times. Range of position error was 0.1957 mm to 0.6520 mm in the stationary phantom and 0.4405 mm to 0.7665 mm in the moving phantom. Average position error was 0.3926 mm and 0.5673 mm in the stationary phantom and the moving phantom respectively. This study evaluates the accuracy of CyberKnife $Synchrony^{TM}$ Respiratory tracking system, and confirms the usefulness when it's used for Stereotactic Radiosurgery of body organs.