• 제목/요약/키워드: TLV

검색결과 457건 처리시간 0.026초

축사 내 황화수소와 암모니아의 저감방안 고찰: 한중비교 (Literature review of the Reduction of Hydrogen Sulfide and Ammonia in Livestock Pen: Comparison between Korean and Chinese cases)

  • 딩옌;문찬석
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.442-451
    • /
    • 2019
  • Objectives: The aim of this study was to review the reduction methods for ammonia (NH3) and hydrogen sulfide (H2S) exposure in livestock. Methods: By reviewing domestic and international research reports from Korea and China, reducing ammonia and hydrogen sulfide in livestock pens was analyzed in terms of ventilation, deodorant, and feed additives. In addition, exposure limits in Korea and China were examined through a comparison between 'TLV-TWA and STEL under the Industrial Safety and Health Act in Korea' and 'Management Standards for Air of Livestock Pens in China'. Results and Discussion: In order to effectively control hazardous gases and odors in livestock pens, the enhancement of natural ventilation or the addition of ventilation fans at the pollution source are being examined. Deodorants are used as adsorbents or masking deodorants. Additives to feed were zeolite powder, FeSO4·7H2O, enzymes, and microbial preparations. Use of feed additives was low-cost and had significant effects compared to other methods. Zeolite was the most commonly used in feed additive in Chinese cases and proved to be low-cost and effective for reducing harmful gases. Enzyme preparations were shown to stimulate the growth of livestock, but were expensive. Conclusions: This study reviewed and examined domestic and international research papers in Korea and China for reducing ammonia and hydrogen sulfide concentrations in livestock pens. More diverse research and the development of feed additives are needed.

센서 어레이와 주성분 기법을 이용한 가연성 가스 인식 (Recognization of Inflammable Gases Using Sensor Array and Principal Component Analysis)

  • 이대식;허증수;이덕동
    • 센서학회지
    • /
    • 제10권2호
    • /
    • pp.108-117
    • /
    • 2001
  • 폭발성 및 가연성 가스의 종류 및 그 정량화론 위한 10개의 개별 센서가 하나의 기판 위에 집적시킨 센서 어레이를 개발하였다. 이 센서어레이는 여러 가지 가연성 가스(부탄, 메탄, 프로판, 일산화탄소, LPG)에 대해서 차별화 된 감도 패턴을 가지도록, 나노 사이즈의 grain를 가지는 $SnO_2$를 모 물질로 하는 10개의 서로 다근 감지 물질로 구성하였고, 센서어레이 전반에서 균일한 온도 분포가 되도록 히터를 기판에 내장시켰다. $400^{\circ}C$에서 동작하는 어레이상의 센서들은 저농도에서도 고감도와 재현성의 특성을 보여 주었다. 이들 감도패턴을 이용하여, 주성분 분석 기법을 통해 환경기준치(LEL, TLV) 범위에서 부탄, 프로판, 메탄, LPG의 폭발성 및 가연성 가스의 종류 인식 및 정량화 할 수 있었다. 그리고, 주성분 분석 기법으로 치적 센서 개수 선정에 응용하였다.

  • PDF

확산길이에 따른 수동식 유기용제 시료채취기의 시료채취성능에 관한 연구 (Sampling Efficiency of Organic Vapor Passive Samplers by Diffusive Length)

  • 이병규;장재길;정지연
    • 한국환경보건학회지
    • /
    • 제35권6호
    • /
    • pp.500-509
    • /
    • 2009
  • Passive samplers have been used for many years for the sampling of organic vapors in work environment atmospheres. Currently, all passive samplers used in domestic occupational monitoring are foreign products. This study was performed to evaluate variable parameters for the development of passive organic samplers, which include the geometry of the device and diffusive length for the sampler design. Four prototype diffusive lengths; A-1(4.5 mm), A-2(7.0 mm), A-3(9.5 mm), A-4(12.0 mm) were tested for adsorption performances to a chemical mixture (benzene, toluene, trichloroethylene, and n-hexane) according to the US-OSHA's evaluation protocol. A dynamic vapor exposure chamber developed and verified by related research was used for this study. The results of study are as follows. The results in terms of sampling rate and recommended sampling time test indicate that the most suitable model was A-3 (9.5 mm diffusive lengths on both sides) for passive sampler design in time weighted average (TWA) assessment. Sampling rates of this A-3 model were 45.8, 41.5, 41.4, and 40.3 ml/min for benzene, toluene, trichloroethylene, and n-hexane, respectively. The A-3 models were tested on reverse diffusion and conditions of low humidity air (35% RH) and low concentrations (0.2 times of TLV). These conditions had no affect on the diffusion capacity of samplers. In conclusion, the most suitable design parameters of passive sampler are: 1) Geometry and structure - 25 mm diameter and 490 $mm^2$ cross sectional area of diffusion face with cylindrical form of two-sided opposite diffusion direction; 2) Diffusive length - 9.5 mm in both faces; 3) Amount of adsorbent - 300 mg of coconut shell charcoal; 4) Wind screen - using nylon net filters (11 ${\mu}m$ pore size).

한국형발사체 연료 동시충전을 위한 유량제어 방식에 대한 고찰 (Analysis on Flow Control Method for Simultaneous Fuel Filling of the Korea Space Launch Vehicle-II)

  • 여인석;이재준;안재철;강선일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.5-13
    • /
    • 2017
  • 한국형발사체 발사를 위하여 나로우주센터에 제 2발사대가 구축될 예정이며 연료공급설비 역시 새롭게 설치된다. 한국형발사체 발사대시스템의 연료공급설비는 나로호 발사대의 설계를 기본 바탕으로 하였다. 하지만 한국형발사체는 나로호 또는 시험발사체와는 달리 3단형 발사체이기 때문에 연료 이송펌프 1대로 1, 2, 3단의 발사체 연료 탱크로 연료를 공급해야한다. 유동해석을 통해 충전 시나리오를 선정하는 과정에서 펌프 토출압력의 급격한 상승 문제를 확인하였다. 이는 오리피스타입의 유량제어방식으로 각 단의 충전모드 전환에 따른 유량변화에 대해 리턴유량이 능동적으로 대응할 수 없기 때문에 발생하였다. 이 문제를 해결하기 위해 다양한 경우에 대해 유동해석을 통해 accumulator 설치와 각 단의 충전모드 전환 순서를 적절히 조정함으로써 안정적으로 공급할 수 있음을 확인하였다.

  • PDF

세라믹 섬유 제조 및 가공 공정에서 발생된 공기중 섬유의 농도 및 크기 분포 (Determination of Airborne Fiber Size and Concentration in RCF Manufacturing and Processing Factories)

  • 신용철
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.21-28
    • /
    • 2000
  • Various man-made mineral fibers(MMMF) including refractory ceramic fiber(RCF) have been used widely in industries as insulation materials. The effect of fibrous dust on human health depends on fiber size, concentration (exposure level), and durability in biological system. Therefore, these parameters should be determined to evaluate accurately the potential risk of fibers on human health. The purpose of this study was to characterize the size of airborne fiber and the workers' exposure to airborne fibers in refractory ceramic fiber manufacturing and processing factories. Airborne fibers were collected on 25-mm mixed cellulose ester membrane filters at personal breathing zones, and analyzed by A and B counting rules of the National Institute for Occupational Safety and Health(NIOSH) Method # 7400. The average ratios of the fiber density by B rule to the fiber density by A rule was 0.84. This result indicates that the proportion of respirable fibers (<3 ${\mu}{\textrm}{m}$ diameter) in air samples was high. The average diameter and length of airborne fibers were 1.05${\mu}{\textrm}{m}$ and 35${\mu}{\textrm}{m}$, respectively. The average fiber concentrations (GM) of all personal samples was 0.26f/cc, and the average concentration was highest at blanket cutting and packing processes. The fifty seven percent of personal air samples was exceeded the proposed American Conference of Governmental Industrial Hygienists(ACGIH) Threshold Limit Value(TLV), i.e. 0.2 f/cc. It was concluded that the RCF industrial workers had the higher potential health risk due to small fiber diameter, long fiber length, and high exposure level to the airborne fibers.

  • PDF

발사체용 지상고정장치 구동유압실린더의 운동특성에 관한 해석적 연구 (Analytical Study on Dynamic Characteristics of Hydraulic Cylinder Applied to the Vehicle Holding Device for Launch Vehicle)

  • 이재준;박상민;양성필;김대래
    • 한국추진공학회지
    • /
    • 제21권1호
    • /
    • pp.44-50
    • /
    • 2017
  • 지상고정장치는 발사체 엔진의 추력이 정상상태에 도달할 때까지 발사체를 발사대에 고정시켜주는 역할을 한다. 본 연구에서는 지상고정장치에 적용되는 구동 유압실린더의 형상 및 운동 특성에 대한 해석적 연구를 수행하였다. 유압 실린더의 수축 운동은 분리 동작에 가장 중요한 요소로서, 해석 결과 실린더의 slit 면적이 축소되고 초기 충전 압력이 증가될수록 수축 하중이 증가함을 확인하였다. 이를 통해 최적화된 slit 면적과 초기 충전압력을 결정하였다. Transient 해석을 통해 실린더가 수축 시 발생하는 하중, 변위, 내부 압력분포를 확인하였다. 해석 결과 실린더가 발생시키는 하중은 실린더에 작용하는 외력과 동일한 값을 발생시키는 것을 확인하였다. 또한 실린더가 운동하는 중에 실린더 내부의 압력분포는 일정한 것을 확인할 수 있었다.

한국형발사체 연료 동시충전을 위한 유량제어 방식에 대한 고찰 (Analysis on Flow Control Method for Simultaneous Fuel Filling of the Korea Space Launch Vehicle-II)

  • 여인석;이재준;안재철;강선일
    • 한국추진공학회지
    • /
    • 제22권5호
    • /
    • pp.132-140
    • /
    • 2018
  • 한국형발사체 발사를 위하여 나로우주센터에 제 2발사대가 구축될 예정이며 연료공급설비 역시 새롭게 설치된다. 한국형발사체 발사대시스템의 연료공급설비는 나로호 발사대의 설계를 기본 바탕으로 하였다. 하지만 한국형발사체는 나로호 또는 시험발사체와는 달리 3단형 발사체이기 때문에 연료 이송펌프 1대로 1, 2, 3단의 발사체 연료 탱크로 연료를 공급해야한다. 유동해석을 통해 충전 시나리오를 선정하는 과정에서 펌프 토출압력의 급격한 상승 문제를 확인하였다. 이는 오리피스타입의 유량제어방식으로 각 단의 충전모드 전환에 따른 유량변화에 대해 리턴유량이 능동적으로 대응할 수 없기 때문에 발생하였다. 이 문제를 해결하기 위해 다양한 경우에 대해 유동해석을 통해 accumulator 설치와 각 단의 충전모드 전환 순서를 적절히 조정함으로써 안정적으로 공급할 수 있음을 확인하였다.

멀티 홉 통신을 기반한 화학 사고 대응 실시간 원격 모니터링 시스템 (Real-time Remote Monitoring System of Chemical Accident Response based on Multi-hop Communication)

  • 이승철;김남호
    • 한국정보통신학회논문지
    • /
    • 제26권11호
    • /
    • pp.1706-1712
    • /
    • 2022
  • 최근 석유화학 산업단지에서 발생하는 가스누출, 화재 등의 사고로 화학물질에 관한 안전이 더욱 중요시되고 있다. 특히 우리나라의 울산, 여수지역의 산단들은 석유화학 산업에 크게 이바지하고 있어 유익함이 있는 반면에, 화학 누출 사고 등으로 인하여 재해가 발생할 수 있다. 따라서 본 논문에서는 화학 사고 대응을 위해 실외 설비 기준 20[m] 간격으로 센서 노드를 구성하고, TLVs의 8시간 기준(TWA)과 15분 기준(STEL)의 노출 허용농도를 제시하였다. 제안된 시스템은 멀티 홉 통신에서 0.6~0.75[s] 주기로 수집된 데이터를 Python으로 전처리하여 SQL 문을 통해 MySQL 데이터베이스에 저장하였으며, MySQL과 Grafana를 연동하여 저장된 데이터를 5초에 1회씩 갱신하는 실시간 원격 모니터링 시스템을 구현하였다.

확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구 (Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents)

  • 안규동;연유용;이병국
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.127-136
    • /
    • 1994
  • 활성탄관을 이용한 작업환경 공기중 유기용제의 시료채취는 여러 가지 어려운 점이 있으나 확산형 시료포집기는 이러한 점을 보완하는 새로운 포집기이다. 따라서 본 연구는 확산형 시료포집기가 혼합 유기용제를 사용하는 사업장을 대상으로 확산형 포집기와 활성탄관을 이용, 한 근로자에 대하여 동시에 각 1개씩, 총 181개의 시료를 포집하여 활성탄과 어떠한 차이가 있는 가를 확인하며, 고전적인 활성탄관 시료채취법을 대신할 수 있는 가를 확인하기 위하여 시도한 바 몇가지의 결과를 얻어 보고하는 바이다. 1. 활성탄관 시료포집기에 비하여 확산형의 시료포집기는 톨루엔(toluene), 키시렌(xylene) 등의 방향족 화합물은 다소 높은 농도를 나타내나 전반적으로 통계적인 유의성은 없었다. 2. 엠이케이(methyl ethyl ketone)와 시크로헥사논(c-hexanone)에 대하여 확산형 포집기는 적어도 저농도(허용농도의 1/8 및 1/10 이하농도)에서 활성탄관에 비하여 약 2배 정도 높게 측정되었다(p<0.01). 그러나 공기중 엠이케이와 시크로헥사논의 농도가 증가함에 따라서 확산형의 포집효율은 활성탄관 보다 적은 것으로 나타났다. 3. 활성탄관의 측정치(B)를 1.00으로 하였을 때 확산형 포집기(A)의 측정치 비(A/B)는 톨루엔의 경우 1.11, 키시렌은 1.07, 엠이케이는 1.63, 시크로헥사논은 3.65배 였다. 4. 활성탄관과 확산형 포집기에서의 측정치 비가 0.75-1.25 범위(${\pm}25%$)에 드는 것은 톨루엔 57%, 키시렌 74%였으며, 엠이케이 34%, 시크로헥사논은 약 32%에 불과하였다. 5. 활성탄관과 확산형 포집기에서의 측정치 간의 각 유기용제 별 상관은 톨루엔 0.963, 키시렌 0.957, 엠이케이 0.943, 시크로헥사논은 0.562로서 모두 통계적으로 유의하였다.

  • PDF

소규모사업장 보건관리지원사업에 대한 평가연구 (An Evaluative Study of a Subsidiary Program in Small Scale Industries)

  • 이명숙;최병수;김명순
    • 한국보건간호학회지
    • /
    • 제11권2호
    • /
    • pp.12-37
    • /
    • 1997
  • This study was performed to evaluate the subsidiary program on occupational health services in small scale industries. The survey of occupational health services was undertaken in 346 industries from July 1 to August 31. 1994. The major results were as follows ; 1. The subsidiary program on occupational health services The evaluation of working environments were conducted in 305 industries, $42.3\%$ of the industries had the harzardous agents exeeding TLV. Special medical examinations were done in 310 industries. the results were detected $C(33.3\%).\;D_1(0.8\%), D_2(5.4\%)$. Health management were done in 341 industries, the average visits for a industry were 3.8 times. The activities of health management were included to check of the workplace. health education, health counselling, etc. 2. The recognition of the employees and employers on occupational health services $91.5\%$ of employers and $87.0\%$ of workers felt healthy themselves. But $39.7\%$ of employers and $21.2\%$ of workers were under the stress from their jobs or home affairs. The workers perceived more harmful for the hazardous agents than the employers. $32.8\%$ of employers and $42.9\%$ of workers perceived that employer's efforts were the most important things to protect for the hazardous agents. The result of the evaluation of working environments were understood by $57.3\%$ of employers and $24.5\%$ of workers. The notification of medical examinations were recognized $83.9\%$ of employers and $50.3\%$ of workers. Many employers and workers felt the necessities of health management in small scale industries. The priorities of health manegement were different between employers and workers. Employers' priorities were as follows ; follow up care of medical examination$(97.3\%)$, health counselling$(93.7\%)$, planning of health$(93.5\%)$, health education of occupational diseases$(93.2\%)$, health education of chronic diseases$(93.5\%)$, etc. Workers' priorities were as follows ; follow up care$(93.4\%)$, health counselling$(94.3\%)$, health education of occupational diseases$(93.0\%)$. first aids$(92.0\%)$. etc.

  • PDF