• Title/Summary/Keyword: THICKNESS

Search Result 26,197, Processing Time 0.053 seconds

Study on Wear of Journal Bearings during Start-up and Coast-down Cycles of a Motoring Engine - II. Analysis Results (모터링 엔진의 시동 사이클 및 시동 정지 사이클에서 저어널베어링의 마모 연구 - II. 해석 결과)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.125-140
    • /
    • 2015
  • In this paper, we present the results of the wear analysis of journal bearings on a stripped-down single-cylinder engine during start-up and coast-down by motoring. We calculate journal bearing wear by using a modified specific wear rate considering the fractional film defect coefficient and load-sharing ratio for the asperity portion of a mixed elastohydrodynamic lubrication (EHL) regime coupled with previously presented graphical data of experimental lifetime linear wear in radial journal bearings. Based on the calculated wear depth, we obtain a new oil film thickness for every crank angle. By examination of the oil film thickness, we determine whether the oil film thickness at the wear scar region is in a mixed lubrication regime by comparing dimensionless oil film thickness, h/σ, to 3.0 at every crank angle. We present the lift-off speed and the crank angles involved with the wear calculation for bearings #1 and #2. The dimensionless oil film thickness, h/σ, illustrates whether the lubrication region between the two surfaces is still within the bounds of the mixed lubrication regime after scarring of the surface by wear. In addition, we present in tables the asperity contact pressure, the real minimum film thickness at the wear scar region, the modified specific wear rate, and the wear angle, α, for bearings #1 & #2. To show the real shape of the oil film at wear scar region, we depict the actual oil film thickness in graphs. We also tabulated the ranges of bearing angles related with wear scar. We present the wear volume for bearings #1 and #2 after one turn-on and turn-off of the engine ignition switch for five kinds of equivalent surface roughness. We show that the accumulated wear volume after a single turn-on and turn-off of an ignition switch normally increases with increasing surface roughness, with a few exceptions.

Preparation of x-cut $LiNbO_3$ Optical Waveguide and the Change in Near-field Properties according to Ti thickness (x-cut $LiNbO_3$ 광도파로 제작 및 Ti 두께에 따른 Near-field 특성 변 화)

  • Kim, Seong-Ku;Yoon, Hyung-Do;Yoon, Dae-Won;Han, Sang-Pill;Kim, Chang-Min;Park, Gye-Chun;Lee, Jin;Yoo, Yong-Taek
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.146-153
    • /
    • 1998
  • The optical near-field patterns, propagation loss and mode sizes of x-cut $Ti:LiNbO_3$ optical waveguide which was fabricated by Ti-diffusion varying with Ti strip thickness in wet oxygen atmosphere were discussed at optical wavelength 1550nm. As Ti thickness increased from $760{\AA}$, the insertion loss of waveguide was decreased. But at Ti thickness $1500{\AA}$, mode sizes are widely broadened. The Ti thickness of below $1100{\AA}$ and above $1500{\AA}$ showed negative effects to propagation loss and fiber coupling. The best Ti thickness for fabricating low propagation loss and good fiber coupling was inferred to be between $1100{\AA}-1500{\AA}$ in our conditions. And for Ti thickness $1150{\AA}$, its propagation loss, horizontal/vertical mode sizes were showed 1.61 dB/cm, $11.9/8.9{\mu}m$ for TM, 0.22 dB/cm, $12.0/9.1{\mu}m$ for TE respectively.

  • PDF

A COMPUTER ANALYSIS ON THE KOREAN CONSONANT SOUND DISTORTION IN RELATION TO THE PALATAL PLATE THICKNESS -Dentoalveolar and hard palatal consonant- (구개상의 두께에 따른 한국어 자음의 발음 변화에 관한 컴퓨터 분석 - 치조음, 경구개음-)

  • Woo, Yi-Hyung;Choi, Dae-Kyun;Choi, Boo-Byung;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.71-94
    • /
    • 1987
  • This study was carried out to investigate the sound distortion following the alternation of the palatal plate thickness. For this study, 2 healthy male subjects (24-year-old) were selected. Born in Seoul, they both spoke Seoul dialect. First, their sounds of /na(나)/, /da(다)/, /1a(라)/, /ja(자)/, /cha(차)/, /ta(타)/, without inserting plates were recorded, and then the sounds with palatal plates of different thickness were recorded, successively. The plate was fabricated in 3 types, each palatal thickness being 1.0mm, 2.5mm, dentoalveolar portion 2.5mm, other residual portion was 1.0mm, successively. Each type plates named B, C, D-type, in succession. Series of analysis were administered through Computer(16 bit) to analyze the sound distortions. These experiments were analyzed by the LPC (without weighting, pre-weighting, post-weighting) of the consonants, vowels portion, formant frequency of the vowels and word duration of the consonants. The findings led to the following conclusions: 1. There was no correlation of the distortion rate on the 2 informants. 2. Generally, vowels were not affected by the palatal plate thickness in the formant analysis, however, more distortion was detected in the LPC analysis, especially C, D-type plates. 3. Consonants distortion was more evident in the C, D-type plate. 4. The second formant was most disturbed and reduced in the all consonants with insertion of the palatal plate, especially C, D-type plate. 5. Word duration was shortened in the plate inserted(except /ja/, /cha/), especially C, D-type. 6. It was found that dentoalveolar, hard palatal sounds were severely distorted in plate inserted, and they were mainly affected by the dentoalveolar portion thickness. 7. There was correlation between palatal thickness and consonants quality.

  • PDF

Sex-, growth pattern-, and growth status-related variability in maxillary and mandibular buccal cortical thickness and density

  • Schneider, Sydney;Gandhi, Vaibhav;Upadhyay, Madhur;Allareddy, Veerasathpurush;Tadinada, Aditya;Yadav, Sumit
    • The korean journal of orthodontics
    • /
    • v.50 no.2
    • /
    • pp.108-119
    • /
    • 2020
  • Objective: The primary objective of this study was to quantitatively analyze the bone parameters (thickness and density) at four different interdental areas from the distal region of the canine to the mesial region of the second molar in the maxilla and the mandible. The secondary aim was to compare and contrast the bone parameters at these specific locations in terms of sex, growth status, and facial type. Methods: This retrospective cone-beam computed tomography (CBCT) study reviewed 290 CBCT images of patients seeking orthodontic treatment. Cortical bone thickness in millimeters (mm) and density in pixel intensity value were measured for the regions (1) between the canine and first premolar, (2) between the first and second premolars, (3) between the second premolar and first molar, and (4) between the first and second molars. At each location, the bone thickness and density were measured at distances of 2, 6, and 10 mm from the alveolar crest. Results: The sex comparison (male vs. female) in cortical bone thickness showed no significant difference (p > 0.001). The bone density in growing subjects was significantly (p < 0.001) lower than that in non-growing subjects for most locations. There was no significant difference (p > 0.001) in bone parameters in relation to facial pattern in the maxilla and mandible for most sites. Conclusions: There was no significant sex-related difference in cortical bone thickness. The buccal cortical bone density was higher in females than in males. Bone parameters were similar for subjects with hyperdivergent, hypodivergent, and normodivergent facial patterns.

Analysis for Gate Oxide Dependent Subthreshold Swing of Asymmetric Double Gate MOSFET (비대칭 DGMOSFET의 문턱전압이하 스윙에 대한 게이트 산화막 의존성 분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.885-890
    • /
    • 2014
  • This paper has presented the change of subthreshold swings for gate oxide thickness of asymmetric double gate(DG) MOSFET, and solved Poisson equation to obtain the analytical solution of potential distribution. The Gaussian function as doping distribution is used to approch experimental results. The symmetric DGMOSFET is three terminal device. Meanwhile the asymmetric DGMOSFET is four terminal device and can separately determine the bias voltage and oxide thickness for top and bottom gates. As a result to observe the subthreshold swings for the change of top and bottom gate oxide thickness, we know the subthreshold swings are greatly changed for gate oxide thickness. Especially we know the subthreshold swings are increasing with the increase of top and bottom gate oxide thickness, and top gate oxide thickness greatly influences subthreshold swings.

Thickness dependence of ZnO thin films grown on sapphire by PLD (PLD법에 의해 제조된 ZnO박막의 두께 변화에 따른 특성 연구)

  • Yun, Uk-Hui;Myeong, Jae-Min;Lee, Dong-Hui;Bae, Sang-Hyeok;Yun, Il-Gu;Lee, Sang-Ryeol
    • Korean Journal of Materials Research
    • /
    • v.11 no.4
    • /
    • pp.319-323
    • /
    • 2001
  • In order to investigate the effect of thickness on the properties of ZnO thin films, a series of films having different thickness were deposited on (0001) sapphire by using pulsed laser deposition(PLD). SEM and XRD analyses showed that, as the film thickness increases, the grain size increased and the crystallinity improved. Room-temperature PL spectra also exhibited that the intensities of both ultraviolet and deep level emission Peaks increased as the film thickness increased. Hall measurements at room- temperature revealed that, as the film thickness changes from 400 to 4000 , the carrier concentration of the film showed sharp decrease, which that of thicker film gradually saturated. Therefore, it is concluded that the strain due to the lattice mismatch between substrate and film is fully relaxed around the thickness of 4000 .

  • PDF

Multidetector CT (MDCT) Arthrography in the Evaluation of Shoulder Pathology: Comparison with MR Arthrography and MR Imaging with Arthroscopic Correlation (Multidetector CT arthrography를 이용한 견관절 병변의 진단 - MRI, MR arthrography와의 비교 -)

  • Kim, Jae-Yoon;Gong, Hyun-Sik;Kim, Woo-Sung;Choi, Jung-Ah;Kim, Byung-Ho;Oh, Joo-Han
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Purpose: The purpose of the present study was to evaluate the diagnostic efficacy of CT arthrography (CTA) in the assessment of various shoulder pathologies, compared with MR arthrography (MRA) and MRI with arthroscopic correlation. Materials and Methods: CTA in 84 patients, MRA in 70 patients, and MRI in 27 patients were obtained. A radiologist interpreted each image for 5 pathologies: Bankart, SLAP, Hill-Sachs lesion, full-thickness, and partial-thickness rotator cuff tear. Detailed arthroscopic reports were compared with CTA, MRA, and MRI. The sensitivity, specificity, predictive values, and accuracy were calculated. The agreement between each diagnostic modality and arthroscopy was calculated. Diagnostic efficacy was assessed by the areas under the receiver operating characteristic (ROC) curves. Results: The diagnostic values of all three imaging groups were comparable to each other for Bankart, SLAP, Hills-Sachs, and full-thickness cuff tear lesions, but those of CTA were lower than MRI and MRA for partial-thickness cuff tears. The areas under the ROC curves for CTA, MRA, and MRI were not significantly different for all pathologies, except for partial-thickness cuff tears. Conclusion: CTA was equally competent to MRA or MRI in demonstrating Bankart, Hill-Sachs lesions, SLAP, and full thickness rotator cuff tears but not as efficient in diagnosing partial thickness rotator cuff tears.

Study on the Determination of Fire Protection Thickness based on Section Factor (강재의 단면형상에 따른 내화피복두께 산정 연구)

  • 정청운;지남용;권인규
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

COMPARATIVE STUDY OF FRACTURE STRENGTH DEFENDING ON THE THICKNESS OF SOME ALL CERAMIC CORES (수종의 전부도재관 코어의 두께에 따른 파절강도의 비교 연구)

  • Kim Doo-Yong;Lee Young-Soo;Park Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.49-57
    • /
    • 2004
  • Statement of problem : The increased awareness of esthetics in dentistry has brought the esthetic consideration in prosthetic restorations . Dental ceramics offer better esthetics for use of prosthetic restorations. Unfortunately, dental ceramic materials are not always the most suitable candidate materials since their inherently brittle nature. In recent years, basic research in ceramic science has led to the recognition or several approaches to strengthen and to enhance esthetics of ceramics. Several all ceramic systems use ceramic core and porcelain build up structures . Ceramic cores influence to strength of all ceramic crowns . So the strength of ceramic cores is important to all ceramic crowns. Purpose : The purpose of this study is to estimate the flexural strength of ceramic cores in some all ceramic systems. Material and method : A biaxial flexure test was conducted on three groups(Cergo, Empress 2, In-Ceram). Each group consisted of 30 discs of nearly identical dimension with a 0.5mm, 1.0mm, 1.5mm thickness and 12mm in diameter. The fracture load was recorded by Instron. Analysis of valiance(ANOVA) and Tukey's tests were performed using SAS statistical software. Results : 1.5mm thickness of specimens were significantly stronger than 0.5mm and 1.0mm thickness of specimens in Cergo and In-Ceram. But each sepecimen group of Empress 2 was no significantly strength by thickness. In order of In-Ceram, Empress 2 and Cergo has significantly stronger strength in the same thickness. Conclusion : In-Ceram is the strongest ceramic material in 3 materials. All the materials can be used according to the required characters.

Thickness Dependence of Microwave Permeability in CoFeHfO Thin Films (CoFeHfO 박막 재료의 두께에 따른 마이크로파 투자율 특성)

  • Lee, Young-Suk;Kim, Cheol-Gi;Kim, Dong-Young
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.228-233
    • /
    • 2010
  • The microwave permeability was measured in order to analyze the thickness dependence of loss properties in CoFeHfO thin films with varying thickness of t = 57~1368 nm. A single resonance peak (P1) at 2.95 GHz was appeared in the samples with thickness less than 405 nm, while second resonance peak (P2) at 547MHz was additionally appeared in the samples with thickness greater than 405 nm. The P2 was originated by the angle distribution of the easy axis, which was confirmed from the measured results of the change of imaginary permeability with applied magnetic field in the sample of 1368 nm thickness and low field torque curves. If the second peaks can be reduced by minimizing the angle distribution of the easy axis, the CoFeHfO thin films with thickness greater than 400 nm can be used for the compact microwave devices operated at up to 2 GHz ranges.