• 제목/요약/키워드: THICKNESS

검색결과 26,196건 처리시간 0.044초

넙다리네갈래근의 근수행력과 근두께에 대한 등속성 운동의 효과 (Effects of Isokinetic Exercise on Muscular Performance and Thickness of the Quadriceps Muscle)

  • 한상완;이정우
    • The Journal of Korean Physical Therapy
    • /
    • 제22권4호
    • /
    • pp.49-55
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of isokinetic exercise on muscular performance and thickness of the quadriceps muscle. Methods: Twenty one healthy male students participated in this study. Participants were divided into 2 groups: $60^{\circ}/sec$ of isokinetic exercise (n=7), $180^{\circ}/sec$ (n=7) and $300^{\circ}/sec$ (n=7). Each group did isokinetic exercises 3 times a week for 6 weeks. Each group was measured for peak torque per body weight, average power and total work using a Biodex System 4. Rectus femoris, vastus laterails and vastus medialis were measured for muscle thickness using a SONOACE 6000C. Data were analyzed by repeated measures ANOVA using SPSS 12.0. Results: There was a significant time-related effect in peak torque per body weight, average power and total work. There was a significant time-related effect in the vastus medialis and rectus femoris muscle thickness. However, there was a significant group by time interaction for vastus laterlis muscle thickness. Conclusion: Isokinetic exercise may be an effective method for improving quadriceps muscle performance regardless of angular velocity. However, the thickness of the rectus femoris and vastus medialis muscle may be increased regardless of the angular velocity of the quadriceps muscle the vastus lateralis muscle may only be remarkably improved when doing exercise with low angular velocity.

Multiphase material topology optimization of Mindlin-Reissner plate with nonlinear variable thickness and Winkler foundation

  • Banh, Thanh T.;Nguyen, Xuan Q.;Herrmann, Michael;Filippou, Filip C.;Lee, Dongkyu
    • Steel and Composite Structures
    • /
    • 제35권1호
    • /
    • pp.129-145
    • /
    • 2020
  • In typical, structural topology optimization plays a significant role to both increase stiffness and save mass of structures in the resulting design. This study contributes to a new numerical approach of topologically optimal design of Mindlin-Reissner plates considering Winkler foundation and mathematical formulations of multi-directional variable thickness of the plate by using multi-materials. While achieving optimal multi-material topologies of the plate with multi-directional variable thickness, the weight information of structures in terms of effective utilization of the material at the appropriate thickness location may be provided for engineers and designers of structures. Besides, numerical techniques of the well-established mixed interpolation of tensorial components 4 element (MITC4) is utilized to overcome a well-known shear locking problem occurring to thin plate models. The well-founded mathematical formulation of topology optimization problem with variable thickness Mindlin-Reissner plate structures by using multiple materials is derived in detail as one of main achievements of this article. Numerical examples verify that variable thickness Mindlin-Reissner plates on Winkler foundation have a significant effect on topologically optimal multi-material design results.

압출 블로우 성형에서 성형조건에 따른 성형특성 (Blow Characteristics in Extrusion Blow Molding for Operational Conditions)

  • 전재후;배유리;류민영
    • 소성∙가공
    • /
    • 제14권3호
    • /
    • pp.233-238
    • /
    • 2005
  • Blow molding is divided into three categories, injection stretch blow molding, injection blow molding, and extrusion or direct blow molding. Extrusion blow molding has been studied experimentally to characterize the blowing behavior of parison. Blow conditions such as blowing temperature and cooling time were the experimental variables in this blowing experiment. Wall thickness of the lower part of blow molded sample was thicker than that of the upper part because of the sagging of parison during extrusion process. As temperature increases the wall thickness and the weight of blow molded sample decreased. No thickness variations in the blowing sample were observed according to the cooling time. The lower part of the sample showed high degree of crystallinity compare with the upper part of the sample. Thus the lower part of the sample was strong mechanically and structurally. It was recognized that the uniform wall thickness could not be obtained by only controlling the operational conditions. Parison variator should be introduced to get uniform wall thickness of parison and subsequently produce uniform wall thickness of blow molded product.

링기어의 경계조건이 가공오차를 가지는 유성기어열의 정특성에 미치는 영향 (Influence of Ring Gear Boundary Conditions on the Static Characteristics of Epicyclic Gear Trains with Manufacturing Errors)

  • 천길정
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1949-1957
    • /
    • 2003
  • A hybrid finite element analysis was used to analyze the influence of ring gear rim thickness and spline number on the static properties of a planetary gear system with manufacturing errors. Both of these parameters affected the bearing force and critical stress. The effect of changes in the rim thickness on the load sharing between the gears depended on the type of manufacturing error. Ring flexibility improved the load sharing between planetary gears only in systems with planet tooth thickness or planet tangential errors; for other types of error, ring flexibility worsened the load sharing. To improve load sharing, rim thickness and spline number should be controlled within a specific range. The minimum rim thickness limit should be determined considering not only the critical stress but also the load sharing. The effect of the ring gear boundary condition was more apparent in a system with errors than in a normal system.

안면도에서1998년 봄철에 관측된 황사의 광학적 특징 (Aerosol Optical Thickness of the Yellow Sand from Direct Solar Radiation at Anmyon Island during the Spring of 1998)

  • 신도식;김산;김정식;차주완
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.739-746
    • /
    • 1999
  • The spectral aerosol optical thickness of vertical air columns were measured by a ground-based multi-channel sunphotometer at the BAPMoN station(36$^{\circ}$31'N, 126$^{\circ}$19'E) in Anmyon Island, Korea, from 1 March 1998 to 31 May 1998. We used the data of three yellow sand and two clear sky days in order to analyze the temporal variations in aerosol optical thickness at the station. The basic aerosol optical thickness generally represented smaller than 0.3 in a clear sky and the range 0.5 to 1.1 in yellow sand. Especially the aerosol optical thickness represented larger than 0.9 in a heavy yellow sand. It was found that the aerosol optical thickness of yellow sand was highly increased in comparison with the case of a clear sky andparticles larger than 0.5$mu extrm{m}$ were also increased in the spectral distribution of aerosol volume during yellow sand. Consequently the spectral variations in tropospheric aerosol caused by yellow sand were determined by the number concentration of particles larger than 0.5${\mu}{\textrm}{m}$ and the magnitude of yellow sand.

  • PDF

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • 한국임상보건과학회지
    • /
    • 제6권1호
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.

SH-EMAT를 이용한 알루미늄 박판의 두께감육 평가 (Evaluation of Thickness Reduction in an Aluminum Sheet using SH-EMAT)

  • 김용권;박익근
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.74-78
    • /
    • 2010
  • In this paper, a non-contact method of evaluating the thickness reduction in an aluminum sheet caused by corrosion and friction using SH-EMAT (shear horizontal, electromagnetic acoustic transducer) is described. Since this method is based on the measurement of the time-of-flight and amplitude change of guided waves caused from the thickness reduction, it provides information on the thinning defects. Information was obtained on the changes of the various wave features, such as their time-of-flight and amplitude, and their correlations with the thickness reduction were investigated. The interesting features in the dispersive behavior of selected guided modes were used for the detection of thinning defects. The measurements of these features using SH waves were performed on aluminum specimens with regions thinned by 7.2% to 29.5% of the total thickness. It is shown that the time-of-flight measurement provides an estimation of the thickness reduction and length of the thinning defects.

Effects of Blood Flow Restriction and Different Support Surfaces on the Thickness of Type-I Muscle Fibers in the Trunk

  • Park, Jae-Cheol;Oh, Seung-Keun;Jeong, Jin-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • 제29권2호
    • /
    • pp.69-73
    • /
    • 2017
  • Purpose: This study was conducted to investigate the effects of blood flow restriction and different support surfaces for bridge exercises on the thickness of the transverse abdominis and multifidus, which are trunk-stabilizing muscles. Methods: The study's subjects were 45 adults who were divided into three groups that performed bridge exercises over a six-week period on their respective support surfaces after blood flow restriction. Changes in the thickness of the subjects' transverse abdominis and multifidus muscles were measured using ultrasonography before the experiment, then three and six weeks after the experiment. The changes in each variable over time were analyzed using a repeated-measures analysis of variance (ANOVA). Results: The transverse abdominis showed significant differences in muscle thickness with regard to time and the interaction between time and each group (p<0.05), but no significant differences with regard to changes among groups (p>0.05). The multifidus showed significant differences in muscle thickness with regard to time, the interaction between time and each group, and changes between groups (p<0.05). Conclusion: Blood flow restriction and different support surfaces for bridge exercises led to significant differences in the thickness of the transverse abdominis and multifidus. This study's results may be used as the basis for future studies and for rehabilitation in clinical practice.

CAD/CAM 세라믹의 두께가 색조에 미치는 영향 (Effect of CAD/CAM ceramic thickness on shade)

  • 강월;한만소;김지환
    • 한국치위생학회지
    • /
    • 제16권5호
    • /
    • pp.695-700
    • /
    • 2016
  • Objectives: The purpose of the study was to investigate the effect of CAD/CAM ceramic thickness on shade. Methods: 24 disk-shaped ceramic specimens (E.Max CAD & Empress CAD, $12mm{\times}12mm$) were prepared and divided into 4 groups (n=6). Ceramic specimens in 2 thicknesses (0.8 mm, 1.0 mm) were made low translucency(LT) shade A2. All specimens were measured as L*, a*, b* using spectrophotometer. The color differences(${\Delta}E$ values) between the specimen and a control target block ($12{\times}12{\times}1.2mm$) were calculated. Two-way ANOVA performed between 2 groups(material and thickness). Results: As the thickness increased, the $L^*$ (for all groups) and $b^*$ value (for all groups) increased and the $a^*$ value(for LR group) decreased. The mean color differences caused by thickness was acceptible (${\Delta}E$ > 2) for group LD1. But the mean color differences by thickness were not selected (${\Delta}E$ < 2) for group LD2, LR1, LR2. Conclusions: The different thickness can influence the final color of CAD/CAM ceramic.

Characterizing Yarn Thickness Variation by Correlograms

  • Huh You;Kim Jong S.;Kim Sung H.;Suh M. W.
    • Fibers and Polymers
    • /
    • 제6권1호
    • /
    • pp.66-71
    • /
    • 2005
  • The surface evenness and texture are closely related with the irregularity of yam thickness. Besides, yam thickness variation has an important role to influence the yam performance and the textile process efficiency. Thus, the information not only on the yam thickness, but also on the short- term irregular characteristics that have not been known before is required for enhancing the qualities of textile products. This paper reports the results of a study about the yam thickness and its variation for various types of yam on the basis of a new measurement system applying a laser slit beam as a light source. The new method delivers effective information on the irregularity. The analysis of the measured signal confirms that the visual shade created by the yam doubling and twisting can be measured and the yam thickness characteristics can be represented by corre­lograms. Depending on yam types, correlograms have different shapes and can be approximated to an exponentially decaying function with or without fluctuating magnitude. In addition, the effective information on the yam irregularity can be influ­enced by the sampling length interval of the measuring device used for tests.