• Title/Summary/Keyword: THICKNESS

Search Result 26,125, Processing Time 0.045 seconds

Fabrication and Characterization of Cellulose Electro-Active Paper with Increased Thickness (두께를 증가시킨 셀룰로오스 Electro-Active Paper 의 제조와 특성평가)

  • Kim, Ki-Baek;Jung, Hyejun;Kim, Jaehwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.241-246
    • /
    • 2013
  • This paper reports fabrication and characterization of cellulose Electro-Active Paper (EAPap) with increased thickness. Usual thickness of cellulose EAPap was $15{\mu}m$. This thickness needs to be increased to enhance the mechanical force output of EAPap. To fabricate thick cellulose EAPap, the fabrication process parameters including casting and drying processes should be investigated. In this paper, the casting thickness is increased from $800{\mu}m$ to $1500{\mu}m$, and heating times on a hot plate before and after curing process are introduced at 40 and $60^{\circ}C$ for 30 and 60 minutes, respectively. Thickness measurement, Thermal Gravitational Analysis (TGA), UV-transmittance, Young's modulus, and piezoelectric charge constant are measured. Heated EAPaps with increased thickness have similar TGA result, higher transmittance, higher Young's modulus and lower piezoelectric charge constant.

Effects of Carcass Weight and Back-fat Thickness on Carcass Properties of Korean Native Pigs

  • Kim, Gye-Woong;Kim, Hack-Youn
    • Food Science of Animal Resources
    • /
    • v.37 no.3
    • /
    • pp.385-391
    • /
    • 2017
  • Our study analyzed the carcass properties of 170 Korean native pigs in relation to carcass weight and back-fat thickness to provide general data for the production and distribution of high quality pig meat. The 70-74 kg group showed highest yield (73.41%). The ${\geq}80kg$ group showed the highest thickest back-fat (24.13 mm) (p<0.05). The ${\geq}80kg$ group showed the best quality grade (1.00). Back-fat thickness showed significant differences in the weight among groups (p<0.05). The ${\geq}25mm$ group showed the highest carcass weight (75.93 kg). The thickest back-fat group (${\geq}25mm$) showed the highest yield (73.03%). There were significant differences in back-fat thickness among groups (p<0.05), and the ${\geq}25mm$ group showed the highest thickness back-fat (27.60 mm). We found a strong positive correlation between carcass weight and back-fat thickness (r=0.346) as well as meat quality grade (r=0.739). Backfat thickness had a relatively strong positive correlation with meat quality grade (r=0.444). Therefore, there are required to manage the breeding through selection of excellent native species for increasing their carcass weight and enhance meat quality.

The Study of Asymmetrical of the Serratus Anterior and Lower Trapezius Muscles in Chronic Stroke Patients (만성 뇌졸중 환자의 앞 톱니근과 하부 등세모근의 비대칭성 연구)

  • Jeong, Ju-Ri;Lee, Wan-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.81-90
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the muscle architecture of serratus anterior and lower trapezius using rehabilitative ultrasound imaging (RUSI) in affected and unaffected side of chronic stroke patients. METHODS: The participants were thirty five patients with stroke hemiplegia in this study. RUSI was used to measure the muscle thickness of the serratus anterior and lower trapezius muscles. We compared the muscle thickness according to affected side and sex, determined the reliability of the measurement image. Independent t-test, intra-class correlation coefficient (ICC) and standard error of measurement (SEM) were used for statistical analysis. RESULTS: Significant difference in muscle thickness of serratus anterior was observed between affected and unaffected side (p<.001). Muscle thickness according to gender showed a significant difference in unaffected side of serratus anterior (p<.05). Compare asymmetry ratio of serratus anterior and lower trapezius muscle thickness showed a significant difference (p<.001). ICC for intra-reliability was .944~.962 in serratus anterior and .873~.925 in lower trapezius muscle thickness, respectively. SEM was .001~.004 in serratus anterior and .002~.008 in lower trapezius muscle. CONCLUSION: This study, using RUSI, showed significant difference in muscle thickness of serratus anterior in affected and unaffected side of stroke patients. RUSI is a practical tool for measuring soft-tissue thickness in the scapular region muscle of stroke.

The Effect of Abdominal Muscle Drawing-In Exercise During Bridge Exercise on Abdominal Muscle Thickness, using for Real-time Ultrasound Imaging (초음파 영상을 이용한 교각운동 시 복부 드로잉-인 운동이 복부 근육의 두께에 미치는 영향)

  • Ha, You;Lee, Geon-Cheol;Bae, Won-Sik;Cho, Young-Jae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.231-238
    • /
    • 2013
  • PURPOSE: The purpose of this study is to find out the thickness variation of the superficial and deep abdominal muscles by measuring the thickness of the abdominal muscles. METHODS: 35 young, healthy adults(24 mens and 11 womens) participated in this study. The first, when only bridge exercise we had measured the thickness of their abdominal muscles by the ultrasound. The second, when the abdominal drawing-in during maintaining the bridge exercise we had measured the thickness of their abdominal muscles by the ultrasound. A pared t-test was used to determine a statistical significance for the thickness variation of the superficial and deep abdominal muscles. RESULTS: Results of before and after comparative analysis. The surperficial muscles(rectus abdominis, external obilique) statistically significantly reduced in the thickness and the deep muscle(transeverse abdominis) statistically significantly increased in the thickness. CONCLUSION: We have shown that the abdominal drawing-in exercise during maintaining the bridge exercise was effective to increase in strengthening abdominal deep muscle selectively.

Deformation Characteristics of Miniature Tensile Specimens of a SA 508 C1.3 Reactor Pressure Vessel Steel

  • Byun, Thak-Sang;Chi, Se-Hwan;Hong, Jun-Hwa;Jeong, Ill-Seok;Hong, Sung-Yull
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.182-187
    • /
    • 1996
  • Deformation characteristics of miniature plate tensile specimens have been studied to develop the thickness requirement and a correlation to estimate the mechanical properties of bulk material from miniature specimen data. The material used was a SA 508 C1.3 reactor pressure vessel steel and the thicknesses of miniature tensile specimens varied from ().12 m to 2 mm. The effects of thickness on the tensile deformation properties such as strength, ductility, and necking characteristics were analyzed. The yield and ultimate tensile strengths were independent of specimen thickness when the thickness was larger than about 0.2 mm. The uniform and total elongations decreased as the specimen thickness decreased. It was also observed that the uniform strain component in the width direction decreased with decrease in the specimen thickness, however, that in the thickness direction was rather constant in total thickness range studied. Based on this observation and a relationship between the necking angle and the ratio between strain components, a correlation between the uniform elongations of miniature specimen and standard specimen was derived. The uniform elongations calculated by this new correlation agreed well with the measured values.

  • PDF

Thickness Measurement of a Transparent Thin Film Using Phase Change in White-Light Phase-Shift Interferometry

  • Kim, Jaeho;Kim, Kwangrak;Pahk, Heui Jae
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.505-513
    • /
    • 2017
  • Measuring the thickness of thin films is strongly required in the display industry. In recent years, as the size of a pattern has become smaller, the substrate has become larger. Consequently, measuring the thickness of the thin film over a wide area with low spatial sampling size has become a key technique of manufacturing-yield management. Interferometry is a well-known metrology technique that offers low spatial sampling size and the ability to measure a wide area; however, there are some limitations in measuring the thickness of the thin film. This paper proposes a method to calculate the thickness of the thin film in the following two steps: first, pre-estimation of the thickness with the phase at the peak position of the interferogram at the bottom surface of the thin film, using white-light phase-shift interferometry; second, accurate correction of the measurement by fitting the interferogram with the theoretical pattern through the estimated thickness. Feasibility and accuracy of the method has been verified by comparing measured values of photoresist pattern samples, manufactured with the halftone display process, to those measured by AFM. As a result, an area of $880{\times}640$ pixels could be measured in 3 seconds, with a measurement error of less than 12%.

Thickness Dependence of GZO Gas Sensing Films Deposited on LTCC Substrates (LTCC 기판상에 증착한 GZO 가스 센싱 박막의 두께 의존 특성 연구)

  • Hwang, Hyun Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.215-218
    • /
    • 2011
  • A novel design of gas sensor using Ga-doped ZnO (GZO) thin films which are deposited on low temperature co-fired ceramic (LTCC) substrates is presented. The LTCC substrates with thickness of 400 ${\mu}m$ are fabricated by laminating 12 green tapes which consist of alumina and glass particle in an organic binder. The GZO thin films with different thickness are deposited on LTCC substrates, by RF magnetron sputtering method. The microstructure and sensing properties of GZO gas sensing films are analyzed as a function of the film thickness. The films are well crystallized in the hexagonal (wurzite) structure with increasing thickness. The maximum sensitivity of 3.49 is obtained at 100 nm film thickness and the fastest 90% response time of 27.2 sec is obtained at 50 nm film thickness for the operating temperature of $400^{\circ}C$ to the $NO_2$ gas.

Properties of the Gold and Palladium-Nickel Alloy Plated Layers on Electrical Contact Materials (접점상에 입힌 Au 및 Pd-Ni 합금도금층의 특성)

  • 백철승;장현구;김회정
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.3
    • /
    • pp.107-116
    • /
    • 1992
  • The optimum thickness of Pd-Ni plated layers used as an electrical contact film was investigated by evaluating mechanical, thermal and environmental characteristics. The variations of morphologies and chemical compositions were studied by using SEM, EDS and ESCA. As a result of wear test, the wear resistance behavior of the gold plated layers was not changed with the sliding velocity changes. The palladium-nickel plated layer showed better wear resistance than the gold plated layer at low sliding velocity, but it showed poor wear resistance at high sliding velocity. Under the thermal condition of $400^{\circ}C$ in air, the gold thickness of $2\mu\textrm{m}$ without underplate on phosphorous bronze formed copper oxide on the surface layer by rapid diffusion of copper whereas the gold thickness of $0.8\mu\textrm{m}$ deposited on nickel and palladium-nickel underplate was stable at $400^{\circ}C$. Under the sulfur dioxide environments, the gold thickness of $0.3\mu\textrm{m}$ deposited on the nickel thickness of$ 3\mu\textrm{m}$ and the palladium-nickel thickness of $2\mu\textrm{m}$ underplate was more corrosion-resistant than the gold thickness of $2\mu\textrm{m}$ without underplate on phosphorous bronze. Under the nitric acid vapor environment, corrosion resistance of the gold film was superior to an equivalent thickness of the palladium-nickel film.

  • PDF

Buckling of simply supported thin plate with variable thickness under bi-axial compression using perturbation technique

  • Fan, Haigui;Chen, Zhiping;Wang, Zewu;Liu, Peiqi
    • Structural Engineering and Mechanics
    • /
    • v.70 no.5
    • /
    • pp.525-534
    • /
    • 2019
  • An analytical research on buckling of simply supported thin plate with variable thickness under bi-axial compression is presented in this paper. Combining the perturbation technique, Fourier series expansion and Galerkin methods, the linear governing differential equation of the plate with arbitrary thickness variation under bi-axial compression is solved and the analytical expression of the critical buckling load is obtained. Based on that, numerical analysis is carried out for the plates with different thickness variation forms and aspect ratios under different bi-axial compressions. Four different thickness variation forms including linear, parabolic, stepped and trigonometric have been considered in this paper. The calculated critical buckling loads and buckling modes are presented and compared with the published results in the tables and figures. It shows that the analytical expressions derived by the theoretical method in this paper can be effectively used for buckling analysis of simply supported thin plates with arbitrary thickness variation, especially for the stepped thickness that used in engineering widely.

Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study

  • Palone, Mario;Longo, Mattia;Arveda, Niki;Nacucchi, Michele;De Pascalis, Fabio;Spedicato, Giorgio Alfredo;Siciliani, Giuseppe;Lombardo, Luca
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.135-141
    • /
    • 2021
  • Objective: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness. Methods: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (p < 0.05). Results: Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22. Conclusions: All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.