• 제목/요약/키워드: THICKNESS

검색결과 26,125건 처리시간 0.047초

RF 마그네트론 스퍼터링으로 증착한 두께에 따른 PZT 박막의 강유전 특성에 관한 연구 (Thickness dependence of the piezoelectric characteristic for PZT films using by rf magnetron sputtering)

  • 이태용;박영;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.313-316
    • /
    • 2003
  • The lead zirconate titanate, $Pb(Zr_{0:52}Ti_{0:48})O_3$, films of $0.5\;{\mu}m,\;1\;{\mu}m$ and $2\;{\mu}m$ thickness were fabricated on $Pt/Ti/SiO_2/Si$ substrate by the rf magnetron sputtering method. The PZT films were annealed using by a rapid thermal annealing (RTA) method. The thickness dependence of the film structure, dielectric properties, Polarization-electric field hysteresis loops and capacitance-voltage characteristics were investigated over the thickness range of $0.5\;{\mu}m,\;1\;{\mu}m$ and $2\;{\mu}m$. According to the XRD patterns of the films, (110) peak intensity increases with film thickness increased. The increase of PZT films thickness leads to the decrease of the remanent polarization and the dielectric constant.

  • PDF

Effect of coating thickness on contact fatigue and wear behavior of thermal barrier coatings

  • Lee, Dong Heon;Jang, Bin;Kim, Chul;Lee, Kee Sung
    • Journal of Ceramic Processing Research
    • /
    • 제20권5호
    • /
    • pp.499-504
    • /
    • 2019
  • The effect of coating thickness on the contact fatigue and wear of thermal barrier coatings (TBCs) are investigated in this study. The same bondcoat material thickness (250 ㎛) are used for each sample, which allows the effect of the coating thickness of the topcoat to be investigated. TBCs with different coating thicknesses (200, 400, and 600 ㎛) are prepared by changing processing parameters such as the feeding rate of the feedstock, spraying speed, and spraying distance during APS(air plasma spray) coating. The damage size on the surface are strongly affected by the coating thickness effect. Although the damage size from contact fatigue using a spherical indenter diminish at a TBC of 200 ㎛, a high wear resistance such as a low friction coefficient and little mass change are found at a TBC of 600 ㎛. These results indicate that the coating thickness strongly affects the mechanical behavior in TBCs during gas turbine operation.

토목섬유로 보강된 철도노반의 동상 및 지지력 평가 (Estimation of Reinforced Railway Roadbed by Geosynthetics on Frost and Bearing Capacity)

  • 심재범;채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.117-128
    • /
    • 1999
  • Geosynthetics have been studied especially Korean Railway earth works from the outset and have proved successful in both technical and economic terms. Hitherto Geosynthetics have been given consideration chiefly in dimensioning the requisite track subbase thickness, but have not been considered when calculating the thickness of the frost protection layer. this often made it impossible to reduce the thickness of the subbase. The article therefore puts forward a proposal for considering the German Geosynthetics in dimensioning the requisite thickness of the frost protection layer.

  • PDF

유기 증착 공정을 위한 박막 형상 모델링 EL (Geometric Modeling of Thin-film Thickness Profile for the OLED Evaporation Process)

  • 이응기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1444-1447
    • /
    • 2004
  • For the OLED evaporation process, thin film thickness uniformity is of great practical importance. In order to achieve the better thickness uniformity, geometric simulation of film thickness distribution profile is required. In this paper, a geometric modeling algorithm is introduced for process simulation of full-color OLED evaporating system. The physical fact of the evaporation process is modeled mathematically. Based on the developed method, the uniformity of the organic layer thickness can be successfully controlled.

  • PDF

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

콘크리트 강도에 따른 바닥판 수직진동에 대한 적정 두께 제안 (The Adequate Slab Thickness Satisfied with the Vertical Floor Vibration Criteria for Several Concrete Compressive Strength)

  • 남상욱;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.659-662
    • /
    • 2003
  • Recently, the floor thickness in residence may not be satisfied with the floor vibration criteria although the thickness is evaluated by the serviceability requirements in current design provisions. Thus it is necessary to develop the procedure to determine slab thickness satisfied with the floor vibration criteria. In this study, We proposed the methods to determine the slab thickness satisfied with the vertical floor vibration criteria for several concrete compressive strength of flat plate floor systems. For this purpose Monte Carlo simulation procedure was adopted and both randomness inherent in young modulus of concrete and heel drop intensity were accounted.

  • PDF

기계식 인공심장판막의 경량화 설계를 위한 구조해석 (Structural Analysis for Thickness Minimization Design of a Bileaflet Mechanical Heart)

  • 권영주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.643-646
    • /
    • 2001
  • This paper investigates the structural analysis and design of mechanical heart valve through the numerical analysis methodology. In a numerical analysis methodology application to the thickness minimization structural design of mechanical heart valve, structural analysis is performed for the blood flow through a bileaflet mechanical heart valve. The structural static analysis is carried out to confirm the thickness minimization structural condition (minimum thickness shape of leaflet).

  • PDF

스테인리스 409L 버링가공 시 두께변화에 대한 연구 (The study on the thickness change in burring with stainless 409L)

  • 김효준;류호연;김형재;김덕규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.107-108
    • /
    • 2009
  • This study is focused on the thickness change in burring with stainless 409L according to the change of main design variables and forming conditions, to manufacture the automobile exhaust flange. Large plastic deformations by burring process decreases thickness of inner radius and occurs cracks. The optimal design of performs by the finite element analysis achieves adequate improvement of thickness decrease.

  • PDF

직물의 표면 정지 공기층의 두께 측정 (Measurement of Thickness of Still Air Layer above Fabrics)

  • 나영주
    • 한국의류학회지
    • /
    • 제21권7호
    • /
    • pp.1117-1123
    • /
    • 1997
  • This paper describes the measurement of thickness of still air layer above fabrics and its relationship to structural properties of fabrics. Rayon fabrics - of both filament and spun - and wool nylon blended fabrics varied in terms of surface hairiness were used. Temperature and relative humidity above fabrics were measured at the various distances from the fabric surface. Increase in the thickness of fabric, fabric weight, yarn count, and crimp resulted increase in thickness of still air layer above fabric. Surface hairiness of fabrics as well as the structural properties were found to be related with the thickness of still air layer above fabrics.

  • PDF

Study on Thickness of Porous Silicon Layer According to the Various Anodization Times

  • 장승현
    • 통합자연과학논문집
    • /
    • 제3권4호
    • /
    • pp.206-209
    • /
    • 2010
  • As the etching time is varied, the change of thickness of the porous silicon layers was successfully investigated. The thickness of the PSi layer as a function of anodization time for a p-type substrate that is etched at a constant current density of 50 $mA/cm^2$ in a 35% hydrofluoric acid solution shows a linear relationship between the etching time and the thickness of the PSi layer.